• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 14
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 54
  • 54
  • 27
  • 25
  • 19
  • 19
  • 19
  • 17
  • 14
  • 14
  • 14
  • 13
  • 13
  • 13
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

A detecção e a localização de faltas de alta impedância em sistemas de distribuição utilizando transformadas wavelets e redes neurais artificiais / Detection and location of high impedance faults in distribution systems using wavelets transforms and artificial neural networks

Rodrigo Zempulski Fanucchi 01 September 2014 (has links)
A ocorrência de faltas em sistemas elétricos de distribuição de energia é algo indesejável, porém, inerente ao mesmo devido a sua topologia normalmente aérea. Entre essas faltas, destacam-se as de alta impedância devido às características de corrente de baixa magnitude que surgem quando de sua ocorrência. No presente trabalho, um método baseado em três módulos é apresentado para a detecção e localização de faltas de alta impedância (FAI). No Módulo 1, é realizado um monitoramento contínuo dos sinais de corrente de forma a detectar a ocorrência de uma descontinuidade que pode estar vinculada a ocorrência de uma FAI. Caso haja essa detecção, o Módulo 2 é ativado de forma a analisar se o evento é realmente uma FAI. Por último, depois de detectada a FAI, o Módulo 3 é inicializado e a localização da falta, estimada. Para possibilitar a análise do método proposto e validar os resultados obtidos, um sistema de distribuição real, em conjunto com todas as etapas do sistema de aquisição de dados, foi modelado no software ATP/EMTP. Essa modelagem foi validada a partir de dados reais obtidos quando da ocorrência em campo de um curto-circuito bifásico. Vale ressaltar que um estudo de caso referente à importância da detecção e localização de um evento relacionado a uma FAI em uma concessionária de energia foi também analisado no início do trabalho de forma a mostrar o possível impacto da localização de FAIs nos indicadores de qualidade de serviço na mesma. Pelos resultados observados, a abordagem como um todo se mostra promissora e passível de aplicação no sistema real simulado e avaliado. / The occurrence of faults in overhead distribution networks is undesirable but common based on its topology. Among these events, High Impedance Faults (HIF) is one of the most important due to the fact that it has a small magnitude current. In this dissertation, a modular three-phase method is presented to enable HIF´s detection and location in a distribution system. In the Module 1, the phase currents are monitored in order to detect a discontinuity that can be associated with a HIF´s occurrence. If the Module 1 detected a discontinuity, the Module 2 is initiated and it analyses if the event can be classified as a HIF. Finally, if the Module 2 returns the event as a HIF, the Module 3 is initiated and the possible location of the HIF is estimated. To enable analysis of the proposed method and to validate the results, a real-based distribution system and the acquisition system of a digital relay were modeled in ATP/EMTP software. In order to validate the model, a simulated twophase fault were compared with the data obtained in a real event occurred in the analyzed distribution system. In order to present the importance of detecting and locating a HIF to a distribution utility, a case study was developed in the beginning of its work. Its importance is based on the improvement of the service quality indicators. Based on the results, the proposed method seems to be promising and applicable in a real distribution system.
32

Modelo estocástico parametrizável para o estudo de faltas de alta impedância em sistemas de distribuição de energia elétrica / Parameterizable stochastic model for high impedance fault study on electrical distribution systems

Luiz Henrique Pessôa da Costa Trondoli 22 March 2017 (has links)
As Faltas de Alta Impedância (FAI) causadas pelo rompimento de um condutor da rede primária podem trazer risco à segurança pessoal e ao patrimônio. A detecção deste defeito se faz, portanto, necessária. Não há na literatura um método que estabeleça a solução definitiva para este problema. Ainda, os estudos, quando não baseados em sinais reais, utilizam, por vezes, modelos determinísticos ou que não representam por completo as características geradas pelo defeito. Por este motivo, este trabalho propõe um modelo de falta de alta impedância que visa representar, com elevado detalhamento, a natureza do evento. O modelo desenvolvido é parametrizável para que possa representar as características dos sinais de falta e suas variações, inclusive as não determinísticas, as quais se referenciam na literatura, reproduzindo o comportamento típico de uma falta de alta impedância. O programa de simulação computacional empregado para este fim foi o ATPDraw. Para a validação do sinal gerado pelo modelo, além da comparação visual com sinais de falta reais, foi elaborado um algoritmo de detecção de FAI, o qual busca por características do fenômeno já conceituadas na literatura, com o propósito de analisar o sinal da corrente de falta gerado pelo modelo quando inserido em um sistema de distribuição de energia elétrica. Foi observada a progressão temporal do fenômeno, desde o rompimento do condutor até a formação dos arcos voltaicos. Do sinal de falta, em síntese, foram observadas características como: assimetria, variação de assimetria, ocorrência de buildup, presença e variação dos componentes harmônicos e inter-harmônicos. A observação dessa variedade de características é necessária na detecção de FAI e é coerente com o modelo proposto, já que este é o único presente na literatura capaz de reproduzi-las simultaneamente. Dos casos de falta simulados, todos foram detectados pelo algoritmo de detecção, indicando que os sinais de falta de alta impedância produzidos pelo modelo possuem as características que ele foi projetado para gerar. / High Impedance Faults (HIF) caused by primary conductor rupture can pose personal safety risk and danger to property. Detection of this event is, therefore, required. There is no proposed method in the literature that establishes a decisive solution to this problem. Studies, when not based on real signals, sometimes use deterministic models or models that do not entirely represent the event\'s characteristics. For this reason, this research proposes a high impedance fault model that intend to represent, with high level of details, the nature of this event. The developed model is parametrizable so it can represent fault signal characteristic and its variations, reproducing the typical high impedance fault behavior. The software ATPDraw was used for this purpose. For model\'s behavior and signal validation, in addition to visual comparison with real HIF signals, a detection algorithm was developed, which searches for HIF characteristics presented on literature, with the intent of analyzing the fault current signal generated by the model when inserted on an electrical distribution system. The temporal progression of the event was observed from the conductor rupture until electric arc ignition. From the fault current, characteristics such as: asymmetry, asymmetry variation, buildup, presence and variation of harmonic and inter-harmonic frequencies were analyzed. The evaluation of this variety of characteristics is needed for HIF detection and it only makes sense because the proposed model is the only one presented in literature capable of reproducing of all them simultaneously. All detection tests resulted in positive identification, confirming that the proposed HIF model possesses the intended characteristics.
33

Defected Ground Structure And Its Applications To Microwave Devices And Antenna Feed Networks

Kilic, Ozgehan 01 September 2010 (has links) (PDF)
This thesis reports the analysis of the rectangular shaped defected ground structure (RS-DGS) and the application of the structure on some microwave devices. DGS is analyzed in terms of its superior properties, which enables the designers to easily realize many kind of microwave devices which are impossible to achieve with the standard applications. Within the scope of this thesis, the focus is on the rectangular shaped DGS and its characteristic properties. The basic slow wave and high impedance characteristics are utilized in the design of some microwave devices. The design is carried on at the two different frequency bands: X-band and Ka band, centering at 10 GHz and 35 GHz, respectively. Finally, using the high impedance property and the coupling between the defects, a wide band 1 : 4 beam forming network is designed and implemented at 10 GHz.
34

Localização de faltas de alta impedância em sistemas de distribuição de energia : uma abordagem baseada na estimação de parâmetros associados a modelos no domínio do tempo

Iurinic, Leonardo Ulises January 2016 (has links)
A detecção de um tipo particular de falta, denominado de alta impedância, tem sido há muito tempo um desafio para a engenharia de proteção. Por outro lado, se a detecção é realizada com sucesso, ações preventivas e de manutenção devem ser tomadas para evitar prejuízos potenciais. Nesse contexto, os métodos de localização de faltas assumem importante papel, pois contribuem para a rápida restauração do sistema. Entretanto, os métodos clássicos, em particular as formulações a um terminal, não consideram modelos realísticos de faltas de alta impedância na sua formulação. Este tipo de falta se caracteriza pelo contato de um condutor energizado com uma superfície de elevada resistência elétrica, em que o comportamento da tensão em função da corrente apresenta uma característica não linear. Desta forma, esta tese propõe uma nova formulação para a localização de faltas de alta impedância em sistemas de distribuição de energia elétrica, com medições a um terminal, que considere tal efeito. A formulação é proposta para estimar a distância da falta em linhas de distribuição utilizando o método de estimação por mínimos quadrados, desenvolvendo um modelo no domínio do tempo do sistema elétrico e um modelo de falta de alta impedância composto por diodos antiparalelos. Mediante o modelo do sistema elétrico, é possível estimar a distância da falta, juntamente com os parâmetros da falta de alta impedância, usando sinais provenientes de um terminal, como um problema de otimização. Primeiramente, não considerando o efeito capacitivo das linhas, um modelo linear no domínio do tempo é obtido e um estimador de mínimos quadrados linear é proposto. Posteriormente, considerando o efeito capacitivo das linhas, um modelo não linear no domínio do tempo é obtido e um algoritmo de descida é proposto para a estimação dos parâmetros. Os estudos de caso foram realizados no sistema de 13 barras da IEEE modelado no Alternative Transient Program. Em todas as condições simuladas, os resultados obtidos mostraram um desempenho similar da técnica proposta com ou sem a consideração da capacitância das linhas, sendo assim, por simplicidade, optou-se pela desconsideração da capacitância. Os resultados evidenciaram que a técnica de localização de faltas proposta não mostra diferença no seu desempenho com variações do ângulo de incidência da falta e melhora quando o carregamento do sistema diminui. O erro relacionado à estimativa da distância da falta mostra-se, em geral, superior ao erro cometido ao estimar os parâmetros da falta de alta impedância. Por outro lado, os estudos de caso mostram um grande potencial para aplicar a técnica proposta como um detector e classificador de faltas de alta impedância. / High impedance fault location has always been a challenge for protection engineering. On the other hand, if this task is successfully realized maintenance action could be performed in order to avoid potential injuries. For an effective protection scheme the high impedance fault location should be performed, but a lack of research on this area is noted. This thesis proposes a new analytical formulation for high impedance fault location in power systems. The approach is developed in time domain, considering a high impedance fault model composed by two antiparallel diodes. Using this model, the fault distance and fault parameters are estimated as a minimization problem, allowing the location of the fault using one terminal signals. Firstly, the line capacitance is not considered and a linear model in time domain is obtained. In this case, the linear least square estimator is used for parameter estimation. In a second moment, the line capacitance is considered and a non-linear model in time domain is obtained. Hence, a steepest descent based estimator is proposed in order to estimate the parameters. Studies were carried out with the IEEE 13 bus modeled in the Alternative Transient Program. In view of the test results, the non-consideration of line capacitance resulted in similar accuracy in relation to its consideration. The method also is insensitive to the fault inception instant and the reduction of system load reduces the errors related to the estimations. The error related to fault distance estimation is in general greater than the estimation of the high impedance fault parameters. On the other hand, case studies shows the great potential of the technique as a high impedance fault detector method.
35

Localização de faltas de alta impedância em sistemas de distribuição de energia : uma abordagem baseada na estimação de parâmetros associados a modelos no domínio do tempo

Iurinic, Leonardo Ulises January 2016 (has links)
A detecção de um tipo particular de falta, denominado de alta impedância, tem sido há muito tempo um desafio para a engenharia de proteção. Por outro lado, se a detecção é realizada com sucesso, ações preventivas e de manutenção devem ser tomadas para evitar prejuízos potenciais. Nesse contexto, os métodos de localização de faltas assumem importante papel, pois contribuem para a rápida restauração do sistema. Entretanto, os métodos clássicos, em particular as formulações a um terminal, não consideram modelos realísticos de faltas de alta impedância na sua formulação. Este tipo de falta se caracteriza pelo contato de um condutor energizado com uma superfície de elevada resistência elétrica, em que o comportamento da tensão em função da corrente apresenta uma característica não linear. Desta forma, esta tese propõe uma nova formulação para a localização de faltas de alta impedância em sistemas de distribuição de energia elétrica, com medições a um terminal, que considere tal efeito. A formulação é proposta para estimar a distância da falta em linhas de distribuição utilizando o método de estimação por mínimos quadrados, desenvolvendo um modelo no domínio do tempo do sistema elétrico e um modelo de falta de alta impedância composto por diodos antiparalelos. Mediante o modelo do sistema elétrico, é possível estimar a distância da falta, juntamente com os parâmetros da falta de alta impedância, usando sinais provenientes de um terminal, como um problema de otimização. Primeiramente, não considerando o efeito capacitivo das linhas, um modelo linear no domínio do tempo é obtido e um estimador de mínimos quadrados linear é proposto. Posteriormente, considerando o efeito capacitivo das linhas, um modelo não linear no domínio do tempo é obtido e um algoritmo de descida é proposto para a estimação dos parâmetros. Os estudos de caso foram realizados no sistema de 13 barras da IEEE modelado no Alternative Transient Program. Em todas as condições simuladas, os resultados obtidos mostraram um desempenho similar da técnica proposta com ou sem a consideração da capacitância das linhas, sendo assim, por simplicidade, optou-se pela desconsideração da capacitância. Os resultados evidenciaram que a técnica de localização de faltas proposta não mostra diferença no seu desempenho com variações do ângulo de incidência da falta e melhora quando o carregamento do sistema diminui. O erro relacionado à estimativa da distância da falta mostra-se, em geral, superior ao erro cometido ao estimar os parâmetros da falta de alta impedância. Por outro lado, os estudos de caso mostram um grande potencial para aplicar a técnica proposta como um detector e classificador de faltas de alta impedância. / High impedance fault location has always been a challenge for protection engineering. On the other hand, if this task is successfully realized maintenance action could be performed in order to avoid potential injuries. For an effective protection scheme the high impedance fault location should be performed, but a lack of research on this area is noted. This thesis proposes a new analytical formulation for high impedance fault location in power systems. The approach is developed in time domain, considering a high impedance fault model composed by two antiparallel diodes. Using this model, the fault distance and fault parameters are estimated as a minimization problem, allowing the location of the fault using one terminal signals. Firstly, the line capacitance is not considered and a linear model in time domain is obtained. In this case, the linear least square estimator is used for parameter estimation. In a second moment, the line capacitance is considered and a non-linear model in time domain is obtained. Hence, a steepest descent based estimator is proposed in order to estimate the parameters. Studies were carried out with the IEEE 13 bus modeled in the Alternative Transient Program. In view of the test results, the non-consideration of line capacitance resulted in similar accuracy in relation to its consideration. The method also is insensitive to the fault inception instant and the reduction of system load reduces the errors related to the estimations. The error related to fault distance estimation is in general greater than the estimation of the high impedance fault parameters. On the other hand, case studies shows the great potential of the technique as a high impedance fault detector method.
36

Avaliação da técnica de decomposição por componentes ortogonais para identificação de faltas de alta impedância / Evaluation of the orthogonal decomposition technique for high impedance fault detection

Daniel da Costa Picchi 18 May 2018 (has links)
Este trabalho apresenta o estado da arte das técnicas mais aplicadas para localização de faltas e modelagem de faltas de alta impedância e propõe a utilização de uma recente técnica baseada na decomposição dos sinais em componentes ortogonais. Este estudo avalia a aplicabilidade da técnica proposta utilizando dados reais de um sistema de distribuição de energia brasileiro, além de apresentar os conceitos teóricos sobre a decomposição em componentes ortogonais. / This work presents the state of the art of the most used techniques for locating and modelling high impedance faults and proposes the use of a recent technique based on the decomposition of the signals in orthogonal components. The objective of this study is to evaluate the application of the proposed technique using real data from a Brazilian distribution network, and presents the theory on orthogonal decomposition.
37

Electromagnetic modelling of human tissues and its application on the interaction between antenna and human body in the BAN context / Modélisation électromagnétique des tissus humains : application aux interactions entre le corps humain et les antennes dans le contexte des réseaux BAN

Augustine, Robin 08 July 2009 (has links)
In this age of wireless technology, Body Area networks (BAN) is revolutionising the concept of patient care and health monitoring. BAN provides people good assessment of their health status at any time, wherever they are physically. The increased interest in developing effective body (in, on & off) communication systems made phantoms which can mimic the electrical properties of an actual human body necessary. Wearable antennas which are the indispensable part of BAN got to be low pro file and above all influences that human body can make. There should also be a way to reduce the effect of antennas on human body namely specific absorption rate (SAR). In this work effort has been made to develop phantoms suitable for both On body and In body communications. The base materials which are selected for the study are of biological origin (bio ceramics and biopolymers) whose behaviour is closer to that of human tissues. As these phantoms are biocompatible they are essentially non toxic where the conventionally available phantoms are toxic in nature. Different kinds of low profile conformal wearable antennas working at 2.4GHz ISM band were developed and studied in the BAN perspective. Antennas suffer much in terms of matching and efficiency when they are in contact or in the premises of human body. This is a major hurdle in the way to setting up a good body communication network. This work encompasses various techniques adopted to limit the body interferences to an acceptable level. The techniques adopted (Such as Backing Ground Plane, High Impedance Surface & Polymeric Ferrite Sheets) proved to be effective in reducing the sway in antenna characteristics when they are mounted on body. Specific absorption rate is also brought to acceptable levels and thus avoiding the formation of hot spots due to microwave absorption. A safer and cost effective BAN can be set up using this work which will lead to a safer, mobile and healthy future. / Les réseaux BAN (Body Area Network) révolutionnent le concept de la surveillance et de la prise en charge à distance de la santé du patient. Le BAN fournit des informations sur l’état de santé du patient en temps réel quelque soit l’endroit où il se trouve. Dans le « télé monitoring », des capteurs de mouvement, de respiration ou du rythme cardiaque placés à l’intérieur ou sur le corps humain transmettent des données via le réseau sans fil constituant le BAN, une antenne étant associée à chaque nœud du réseau. La communication peut être in/on, on/on ou on/off selon que les antennes sont placées à l’intérieur, sur ou à l’extérieur du corps. Le développement des BAN nécessite la réalisation de modèles (ou fantômes) simulant au mieux les propriétés électromagnétiques du corps humain. Des antennes portables, miniaturisées doivent être réalisées avec des contraintes d’intégration d’une part (aux vêtements, à des objets type montre ou badge), des contraintes de résistance ou de prise en compte de l’influence du corps d’autre part. La réduction de l’impact des antennes sur les tissus en terme de SAR (Specific Absorption Rate) doit également être considérée. Dans ce travail, l’objectif est de développer des fantômes valables pour les communications dans et sur le corps. Les matériaux de base sélectionnés sont d’origine biologique (biocéramiques et biopolymères) avec des propriétés proches de celles des tissus humains. Ces fantômes étant biocompatibles, ils sont essentiellement non toxiques alors que les fantômes usuels le sont en général. D’autre part, différents types d’antennes conformables, fonctionnant dans la bande ISM 2.4 GHz ont été développées et étudiées dans la perspective du BAN. Les antennes voient leur adaptation et leur efficacité chuter au contact ou à proximité du corps, ce qui constitue un écueil majeur pour établir une bonne communication. Différentes méthodes permettant de réduire l’influence du corps (plan de masse à l’arrière, surface haute impédance, feuille de ferrite polymère) sont testés et leurs avantages et inconvénients développés. Des mesures de SAR permettent aussi de démontrer l’efficacité de ces méthodes sur la réduction de la puissance absorbée par les tissus. Au final, ce travail apporte une contribution à l’étude théorique et expérimentale de l’interaction entre corps humain et antenne dans le cadre des réseaux BAN appliqués à la télésurveillance de la santé.
38

Sistema inteligente baseado em decomposição por componentes ortogonais e inferência fuzzy para localização de faltas de alta impedância em sistemas de distribuição de energia elétrica com geração distribuída / Intelligent system based on orthogonal decomposition technique and fuzzy inference for high impedance location fault in distribution systems with distributed generation

Batista, Oureste Elias 28 March 2016 (has links)
Os sistemas elétricos de potência modernos apresentam inúmeros desafios em sua operação. Nos sistemas de distribuição de energia elétrica, devido à grande ramificação, presença de extensos ramais monofásicos, à dinâmica das cargas e demais particularidades inerentes, a localização de faltas representa um dos maiores desafios. Das barreiras encontradas, a influência da impedância de falta é uma das maiores, afetando significativamente a aplicação dos métodos tradicionais na localização, visto que a magnitude das correntes de falta é similar à da corrente de carga. Neste sentido, esta tese objetivou desenvolver um sistema inteligente para localização de faltas de alta impedância, o qual foi embasado na aplicação da técnica de decomposição por componentes ortogonais no pré-processamento das variáveis e inferência fuzzy para interpretar as não-linearidades do Sistemas de Distribuição com presença de Geração Distribuída. Os dados para treinamento do sistema inteligente foram obtidos a partir de simulações computacionais de um alimentador real, considerando uma modelagem não-linear da falta de alta impedância. O sistema fuzzy resultante foi capaz de estimar as distâncias de falta com um erro absoluto médio inferior a 500 m e um erro absoluto máximo da ordem de 1,5 km, em um alimentador com cerca de 18 km de extensão. Tais resultados equivalem a um grau de exatidão, para a maior parte das ocorrências, dentro do intervalo de ±10%. / Modern electric power systems present numerous challenges in its operation. Fault location is a major challenge in Power Distribution Systems due to its large branching, presence of single-phase laterals and the dynamic loads. The influence of the fault impedance is one of the largest, significantly affecting the use of traditional methods for its location, since the magnitude of the fault currents is similar to the load current. In this sense, this thesis aimed to develop an intelligent system for location of high impedance faults, which was based on the application of the decomposition technique of orthogonal components in the pre-processing variables and fuzzy inference to interpret the nonlinearities of Power Distribution Systems with the presence of Distributed Generation. The data for training the intelligent system were obtained from computer simulations of an actual feeder, considering a non-linear modeling of the high impedance fault. The resulting fuzzy system was able to estimate distances to fault with an average absolute error of less than 500 m and a maximum absolute error of 1.5 km order, on a feeder about 18 km long. These results are equivalent to a degree of accuracy for the most occurrences within the ± 10% range.
39

Identificação de faltas de alta impedância em redes aéreas multiaterradas. / Identification of high impedance faults in overhead multi grounded networks.

Arias, Juan Camilo Garcia 12 December 2014 (has links)
As faltas de alta impedância (FAI) ocorrem quando um condutor entra em contato com objetos com uma alta resistência, o que não resulta em incrementos significativos de corrente. Este tipo de falta não pode ser detectada por dispositivos de proteção tradicionais que atuam por sobrecorrente. Neste trabalho uma pesquisa do estado da arte das FAI é apresentada e são implementados alguns algoritmos de detecção presentes na literatura. Nesta pesquisa também são propostas duas metodologias de identificação de FAI as quais são baseadas na identificação de buildup e incrementos de energias na faixa de frequências 1920Hz a 3840Hz. Os algoritmos implementados e as metodologias propostas foram testados com simulações de eventos de FAI e de eventos comuns numa rede simulada de uma concessionária do Estado de São Paulo utilizando o software ATP. Estudos do funcionamento de um medidor de qualidade de energia foram feitos com o propósito de determinar as limitações de uma eventual implementação real das metodologias de identificação propostas neste trabalho. Resultados do desempenho das metodologias propostas utilizando os sinais simulados em ATP apresentaram percentagens de identificação superiores aos 80%. Análise das ocorrências de cabo rompido do circuito em estudo foram feitas com o propósito de identificar possíveis eventos de FAI. O desempenho apresentado pelas metodologias propostas na identificação de FAI em sinais reais pode ser melhorado com a disponibilidade de uma maior quantidade de eventos reais de FAI. / High impedance faults (HIF) occur when a conductor makes contact with high resistance objects, generally not resulting in significant current increases. This type of fault cannot be detected by traditional overcurrent protection devices. In this work, a research of the HIF state-of-art is presented and some detection algorithms in the literature are implemented. This research also proposes two HIF identification methods based on respectively the identification of buildup current and energy increments in the frequency range from 1920Hz to 3840Hz. The implemented algorithms and the proposed methodology have been tested with ATP simulations of FAI events and other common events in a simulated network from an electric utility in the State of Sao Paulo. Studies are carried out in order to assess the operation of a power quality meter to determine the limitations of real implementations of the proposed methodologies. Performance results of the proposed methodologies using simulated ATP signals show identifications rates greater than 80%. Broken conductor occurrences in the studied feeder are analyzed to identify possible HIF events. The performance shown by the proposed methodologies in identifying HIF in real situations can be improved with the availability of a larger number of HIF events.
40

Identificação de faltas de alta impedância em redes aéreas multiaterradas. / Identification of high impedance faults in overhead multi grounded networks.

Juan Camilo Garcia Arias 12 December 2014 (has links)
As faltas de alta impedância (FAI) ocorrem quando um condutor entra em contato com objetos com uma alta resistência, o que não resulta em incrementos significativos de corrente. Este tipo de falta não pode ser detectada por dispositivos de proteção tradicionais que atuam por sobrecorrente. Neste trabalho uma pesquisa do estado da arte das FAI é apresentada e são implementados alguns algoritmos de detecção presentes na literatura. Nesta pesquisa também são propostas duas metodologias de identificação de FAI as quais são baseadas na identificação de buildup e incrementos de energias na faixa de frequências 1920Hz a 3840Hz. Os algoritmos implementados e as metodologias propostas foram testados com simulações de eventos de FAI e de eventos comuns numa rede simulada de uma concessionária do Estado de São Paulo utilizando o software ATP. Estudos do funcionamento de um medidor de qualidade de energia foram feitos com o propósito de determinar as limitações de uma eventual implementação real das metodologias de identificação propostas neste trabalho. Resultados do desempenho das metodologias propostas utilizando os sinais simulados em ATP apresentaram percentagens de identificação superiores aos 80%. Análise das ocorrências de cabo rompido do circuito em estudo foram feitas com o propósito de identificar possíveis eventos de FAI. O desempenho apresentado pelas metodologias propostas na identificação de FAI em sinais reais pode ser melhorado com a disponibilidade de uma maior quantidade de eventos reais de FAI. / High impedance faults (HIF) occur when a conductor makes contact with high resistance objects, generally not resulting in significant current increases. This type of fault cannot be detected by traditional overcurrent protection devices. In this work, a research of the HIF state-of-art is presented and some detection algorithms in the literature are implemented. This research also proposes two HIF identification methods based on respectively the identification of buildup current and energy increments in the frequency range from 1920Hz to 3840Hz. The implemented algorithms and the proposed methodology have been tested with ATP simulations of FAI events and other common events in a simulated network from an electric utility in the State of Sao Paulo. Studies are carried out in order to assess the operation of a power quality meter to determine the limitations of real implementations of the proposed methodologies. Performance results of the proposed methodologies using simulated ATP signals show identifications rates greater than 80%. Broken conductor occurrences in the studied feeder are analyzed to identify possible HIF events. The performance shown by the proposed methodologies in identifying HIF in real situations can be improved with the availability of a larger number of HIF events.

Page generated in 0.112 seconds