Spelling suggestions: "subject:"host water recirculation""
1 |
Avvikelser mellan projekterad och verifierad energiprestanda för nyproducerade lågenergibyggnader : En studie av AB Bostäders svårigheter att leva upp till uppsatta energikrav i deras nybyggda flerbostadshus / Deviations between projected and verified energy performance for newly constructed low-energy buildings : A study of AB Bostäder's difficulties of meeting the energy requirements set in their newly constructed multi-family residentialGustafsson, Sebastian, Jansson, Gösta January 2017 (has links)
EUs direktiv för energiprestanda innebär att alla nya byggnader från och med 2021 ska vara nära-nollenergibyggnader. De stundande kraven innebär att beställare måste skärpa sina energikrav vid upphandling av flerbostadshus. Vidare spelar lågenergibyggnader som koncept en viktig roll för att nå hållbar utveckling och det är av högsta vikt att kommande byggprojekt blir effektiva både i byggprocess och vidare i driftskedet. Nybyggnation av lågenergibyggnader har visat sig problematisk i många aspekter, där den uppmätta energianvändningen i många fall visat sig väsentligt högre än vad som projekterats. I och med den ny byggpraxis med bättre isolation, lufttäthet och ventilation med återvinning blir tappvarmvatten och hushållsel de största energiposterna i en byggnads energibalans. Syftet med arbetet är att konkretisera problemen som finns för nyproducerade flerbostadshus med energikrav för lågenergibyggnader. Utifrån det har fokus lagts på två byggnader som AB Bostäder låtit bygga – båda projekterade för att uppnå lågenergikrav. Likt befarat visar Examensarbetet att det är svårt att härleda problemet till specifika poster. Byggprocessen i sig kan vara en bidragande faktor, där tidsbrist, bristfällig kommunikation och okunskap kring ny byggpraxis är förekommande i en bransch som har svårt att hinna med den efterfrågade volymen av nybyggnation. Vad gäller specifika felkällor till försämrad energiprestanda stödjer vår rapport tidigare publicerade rapporter i ämnet där bristfällig indata vid energiberäkningar, byggprocessens inverkan, oaktsamhet av VVC-förluster och betydelsen av brukare har belysts. / The energy performance of buildings directive means that all new buildings must be nearly zero energy buildings by 31 December 2020. The current requirements mean that constructor companies must tighten their energy requirements when procuring multi-family houses. Lowenergy buildings as concepts play an important role in achieving sustainable development, and it is of the utmost importance that future construction projects become effective both in the construction process and on further operation. New construction of low-energy buildings has proved to be quite problematic in many aspects, where the measured energy performance in many cases proved to be significantly higher than projected. With the new building practice with better insulation, air tightness and ventilation with recycling – hot water supply and household appliances become the largest energy posts in a building's energy balance. The purpose of this master thesis is to concretize the problems that exist for newly produced multi-family houses with energy requirements for low-energy buildings. Based on this, focus has been on two building that AB Bostäder Borås recently has built – both built to achieve low energy requirements. As expected, this master thesis shows the difficulty to deduce the problem to specific aspects. The construction process itself may be the source of error, where time shortages, inadequate communication and lack of knowledge concerning low energy buildings are present in an industry with difficulties catching up with the demanded volume of new construction. Regarding specific sources of vulnerability to energy performance, our report supports previously published reports where the lack of input data for energy calculations, the impact of the construction process, negligence of losses due to recirculation of hot water and the importance of user behaviour have been highlighted.
|
2 |
Skiljer sig energiberäkningarna i projekteringsstadiet från energiberäkningarna i relationshandlingarna?Ingarsson, Ellen, Sköld, Ellen January 2022 (has links)
To reduce the emissions from energy use, high demands are set on new buildings. Studies have shown big differences between predicted and actual energy performance. This gap makes it more difficult to reduce the energy use in buildings. The aim of this study is to discover if deviations occur before the building is put into use, and if it does, discuss the reasons for that. In this study, energy performance for 20 multi-family houses have been compared between the early design stage and the production stage. The result of this study is that there are no major differences in energy use between the different documents. On the other hand, there are big differences in some of the parameters that the energy use is dependent on. The reasons of this are discussed later in this thesis. None of the investigated buildings had the same value of energy performance in the production stage as in the early stage. The parameter that has shown the greatest difference is space heating and hot water recirculation. The biggest correlation was found between the energy required by the fans and the buildings total energy use.
|
Page generated in 0.1019 seconds