• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lasers à faible bruit d’intensité en InP sur circuit Silicium pour l’optique hyperfréquence / Low noise InP on Silicon lasers for microwave photonics applications

Girard, Nils 14 June 2016 (has links)
L’objectif de ce travail de thèse est d’étudier des lasers semi-conducteur issus de la plateforme d’intégration III-V sur Si et présentant un faible bruit d’intensité relatif (RIN) pour le transport de signaux RADAR par voie optique. Nous cherchons à obtenir des lasers de comportement dynamique dit de «Classe A», i.e. avec une réponse dynamique sans oscillations de relaxation. Dans ce cas, il a été précédemment montré qu’un tel comportement dynamique présente un RIN limité au bruit de grenaille sur une large bande de fréquences et est obtenu quand la durée de vie des photons dans la cavité est grande devant la durée de vie des porteurs dans la zone active. La plateforme photonique sur silicium est alors intéressante car elle permet de réaliser des cavités longues grâce aux guides optiques offrant de faibles pertes de propagation, i.e. de l’ordre du dB/cm. En première approche, nous avons étudié des lasers dont la cavité de longueur centimétrique est composée d’une partie active fournissant le gain optique et d’une partie passive composée de guide en silicium à faibles pertes de propagation. Nous avons proposé différentes optimisations des pertes optiques intra-cavité ainsi que différentes solutions de filtrage spectral à grande finesse nécessaire à une oscillation laser monomode. La seconde approcheétudiée repose sur le filtrage du RIN d’un laser hybride de longueur millimétrique en exploitant les effets de saturation du gain optique dans un amplificateur optique à SC (SOA). Nous avons présenté un modèle décrivant les différents mécanismes altérant le bruit du laser amplifié par un SOA. Une étudeexpérimentale a permis de mettre en évidence la réduction du RIN d’un laser hybride III-V sur silicium, allant jusqu’à 15 dB pour des fréquences allant jusqu’à quelques GHz. La dernière approche explorée dans cette thèse repose sur la conception de lasers DFB hybride III-V sur silicium à très haut facteur de qualité. L’utilisation d’un réseau de Bragg à pas variable permet de réduire les pertes radiatives, usuellement importantes dans les lasers DFB, et d’obtenir une cavité de facteur de qualité de l’ordre de quelques millions. Un premier composant réalisé présente un facteur de qualité de 65 000. / The objective of the present thesis is to investigate new laser architectures with low Relative Intensity Noise (RIN) using the Silicon Photonics integration platform. We intend to reach “class-A” dynamics, in which relaxation oscillations are eliminated. In this conditions, lasers with class-A dynamics exhibit shot-noise limited RIN over a wide frequency bandwidth, typically from 100 MHz to 20 GHz. Such behaviour can be obtained with high-Q laser cavities, i.e with long cavities or with ultra-low losses cavities. The silicon photonics platform is a good candidate for the desired dynamical behaviour as it makes possible the implementation of long cavities (ten’s of cm) based on low losses silicon waveguides (dB/cm). Three different approaches have been considered in the present work. In the first approach, we have developed centimetre long lasers, consisting of an active section providing the optical gain coupled to a passive section made with low losses silicon waveguides. We proposed different approaches to optimize the intra-cavity optical losses, and different architectures of high finesse optical filters allowing simultaneously single-mode operation and high side mode suppression. The second approach consists on filtering the laser RIN by taking advantage of the coherent population oscillations effects in a SC Optical Amplifier (SOA). We proposed a model for describing the different mechanisms altering the RIN of the amplified laser. We demonstrated 15 dB RIN reduction for frequencies up to a few GHz, using a hybrid III-V on Si laser and a “classical” SOA. The last approach explored in the present thesis is based on the use of hybrid III-V on silicon DFB lasers with a high quality factor. Using Silicon Bragg grating with a variable pitch can reduce the radiative losses, usually important in DFB lasers. In this case, we can obtain optical cavities with few millions quality factor, leading to few ns photon lifetime. We realize a first design of Si Bragg grating with a Q factor of 65 000.
2

L'élastographie ultrasonore dynamique vasculaire : une nouvelle modalité d'imagerie non-invasive pour la caractérisation mécanique de la thrombose veineuse

Schmitt, Cédric 04 1900 (has links)
L’accident thromboembolique veineux, tel que la thrombose veineuse profonde (TVP) ou thrombophlébite des membres inférieurs, est une pathologie vasculaire caractérisée par la formation d’un caillot sanguin causant une obstruction partielle ou totale de la lumière sanguine. Les embolies pulmonaires sont une complication mortelle des TVP qui surviennent lorsque le caillot se détache, circule dans le sang et produit une obstruction de la ramification artérielle irriguant les poumons. La combinaison d’outils et de techniques d’imagerie cliniques tels que les règles de prédiction cliniques (signes et symptômes) et les tests sanguins (D-dimères) complémentés par un examen ultrasonographique veineux (test de compression, écho-Doppler), permet de diagnostiquer les premiers épisodes de TVP. Cependant, la performance de ces outils diagnostiques reste très faible pour la détection de TVP récurrentes. Afin de diriger le patient vers une thérapie optimale, la problématique n’est plus basée sur la détection de la thrombose mais plutôt sur l’évaluation de la maturité et de l’âge du thrombus, paramètres qui sont directement corrélées à ses propriétés mécaniques (e.g. élasticité, viscosité). L’élastographie dynamique (ED) a récemment été proposée comme une nouvelle modalité d’imagerie non-invasive capable de caractériser quantitativement les propriétés mécaniques de tissus. L’ED est basée sur l’analyse des paramètres acoustiques (i.e. vitesse, atténuation, pattern de distribution) d’ondes de cisaillement basses fréquences (10-7000 Hz) se propageant dans le milieu sondé. Ces ondes de cisaillement générées par vibration externe, ou par source interne à l’aide de la focalisation de faisceaux ultrasonores (force de radiation), sont mesurées par imagerie ultrasonore ultra-rapide ou par résonance magnétique. Une méthode basée sur l’ED adaptée à la caractérisation mécanique de thromboses veineuses permettrait de quantifier la sévérité de cette pathologie à des fins d’amélioration diagnostique. Cette thèse présente un ensemble de travaux reliés au développement et à la validation complète et rigoureuse d’une nouvelle technique d’imagerie non-invasive élastographique pour la mesure quantitative des propriétés mécaniques de thromboses veineuses. L’atteinte de cet objectif principal nécessite une première étape visant à améliorer les connaissances sur le comportement mécanique du caillot sanguin (sang coagulé) soumis à une sollicitation dynamique telle qu’en ED. Les modules de conservation (comportement élastique, G’) et de perte (comportement visqueux, G’’) en cisaillement de caillots sanguins porcins sont mesurés par ED lors de la cascade de coagulation (à 70 Hz), et après coagulation complète (entre 50 Hz et 160 Hz). Ces résultats constituent les toutes premières mesures du comportement dynamique de caillots sanguins dans une gamme fréquentielle aussi étendue. L’étape subséquente consiste à mettre en place un instrument innovant de référence (« gold standard »), appelé RheoSpectris, dédié à la mesure de la viscoélasticité hyper-fréquence (entre 10 Hz et 1000 Hz) des matériaux et biomatériaux. Cet outil est indispensable pour valider et calibrer toute nouvelle technique d’élastographie dynamique. Une étude comparative entre RheoSpectris et la rhéométrie classique est réalisée afin de valider des mesures faites sur différents matériaux (silicone, thermoplastique, biomatériaux, gel). L’excellente concordance entre les deux technologies permet de conclure que RheoSpectris est un instrument fiable pour la mesure mécanique à des fréquences difficilement accessibles par les outils actuels. Les bases théoriques d’une nouvelle modalité d’imagerie élastographique, nommée SWIRE (« shear wave induced resonance dynamic elastography »), sont présentées et validées sur des fantômes vasculaires. Cette approche permet de caractériser les propriétés mécaniques d’une inclusion confinée (e.g. caillot sanguin) à partir de sa résonance (amplification du déplacement) produite par la propagation d’ondes de cisaillement judicieusement orientées. SWIRE a également l’avantage d’amplifier l’amplitude de vibration à l’intérieur de l’hétérogénéité afin de faciliter sa détection et sa segmentation. Finalement, la méthode DVT-SWIRE (« Deep venous thrombosis – SWIRE ») est adaptée à la caractérisation de l’élasticité quantitative de thromboses veineuses pour une utilisation en clinique. Cette méthode exploite la première fréquence de résonance mesurée dans la thrombose lors de la propagation d’ondes de cisaillement planes (vibration d’une plaque externe) ou cylindriques (simulation de la force de radiation par génération supersonique). DVT-SWIRE est appliquée sur des fantômes simulant une TVP et les résultats sont comparés à ceux donnés par l’instrument de référence RheoSpectris. Cette méthode est également utilisée avec succès dans une étude ex vivo pour l’évaluation de l’élasticité de thromboses porcines explantées après avoir été induites in vivo par chirurgie. / The venous thromboembolism such as the lower limb deep venous thrombosis (DVT) is a vascular pathology characterized by a blood clot formation that induces partial or total vessel lumen occlusion. Pulmonary embolism is a fatal complication of DVT where the clot detaches from the wall, circulates in the blood flow, and produces an obstruction of pulmonary arterial branches. The combination of clinical prediction rules (signs or symptoms) and blood tests (D-dimer testing) coupled to venous ultrasonography (i.e. compression ultrasonography, color Doppler) allows an accurate diagnosis of first DVT. Nevertheless, such clinical tools present poor results to detect recurrent thrombotic events. Then, in order to guide patients towards optimal therapy, the problem is no more to detect the presence of thrombus, but to evaluate its maturity and its age, which are correlated to their mechanical properties (e.g. elasticity, viscosity). The dynamic elastography (DE) has been recently proposed as a novel non-invasive imaging modality capable to characterize the quantitative mechanical properties of tissues. The DE is based on the analysis of acoustical parameters (i.e. velocity, attenuation, wave pattern) of low frequency (10-7000 Hz) shear waves propagating within the probed medium. Such shear waves generated by external vibration, or remotely using ultrasound beam focalisation (radiation force), were tracked using ultra-fast ultrasound or magnetic resonance imaging. A method based on DE and adapted to mechanical characterization of venous thrombosis may allow the quantification of diseases severity in order to improve the final diagnosis. This thesis presents the works related to the development and complete validation of a novel non-invasive elastography imaging method for the quantitative and reliable estimation of mechanical properties of venous thrombosis. In order to fulfil the main objective, it is first necessary to improve knowledge about mechanical behaviours of blood clot (coagulated blood) subjected to a dynamic solicitation similar to DE. The shear storage (elastic behaviour, G’) and loss (viscous behavior, G’’) moduli of porcine blood clots are measured by DE during the blood coagulation kinetics (at 70 Hz) and after completely coagulation (between 50 Hz and 160 Hz). These results are the first dynamic behaviour measurements of blood clots in such wide frequency range. The subsequent step consists in introducing an innovative reference instrument (« gold standard »), called RheoSpectris, dedicated to measure the hyper-frequency viscoelasticity (between 10 Hz and 1000 Hz) of materials and biomaterials. This tool is indispensable to validate new dynamic elastography techniques. A comparative study between RheoSpectris and classical rheometry is performed to validate the measurements on different materials (silicon, thermoplastic, biomaterials, gel). The excellent agreement between both technologies allows to conclude that RheoSpectris is a reliable instrument for mechanical measurements at high frequencies, which is not always possible with current tools. The theoretical basis of a novel elastographic imaging modality, labelled SWIRE (« shear wave induced resonance dynamic elastography ») is presented and validated on vascular phantoms. Such approach allows the characterization of mechanical properties of a confined inclusion (e.g. blood clot) from its resonance (displacement amplification) due to the propagation of judiciously oriented shear waves. SWIRE has also the advantage to amplify the vibration amplitude within the heterogeneity to help for its detection and segmentation. Finally, the method DVT-SWIRE ((« Deep venous thrombosis – SWIRE ») is adapted to the quantitative elasticity estimation of venous thrombosis in the context of clinical use. DVT-SWIRE exploits the first resonance frequency measured within the thrombosis during the plane (vibration of rigid plate) or cylindrical (simulating supersonic radiation force generation) shear waves propagation. The technique is applied on DVT phantoms and the results are compared to those given by the RheoSpectris reference instrument. This method is also used successfully in an ex vivo study for the elasticity assessment of explanted porcine thrombosis surgically induced in vivo.
3

L'élastographie ultrasonore dynamique vasculaire : une nouvelle modalité d'imagerie non-invasive pour la caractérisation mécanique de la thrombose veineuse

Schmitt, Cédric 04 1900 (has links)
L’accident thromboembolique veineux, tel que la thrombose veineuse profonde (TVP) ou thrombophlébite des membres inférieurs, est une pathologie vasculaire caractérisée par la formation d’un caillot sanguin causant une obstruction partielle ou totale de la lumière sanguine. Les embolies pulmonaires sont une complication mortelle des TVP qui surviennent lorsque le caillot se détache, circule dans le sang et produit une obstruction de la ramification artérielle irriguant les poumons. La combinaison d’outils et de techniques d’imagerie cliniques tels que les règles de prédiction cliniques (signes et symptômes) et les tests sanguins (D-dimères) complémentés par un examen ultrasonographique veineux (test de compression, écho-Doppler), permet de diagnostiquer les premiers épisodes de TVP. Cependant, la performance de ces outils diagnostiques reste très faible pour la détection de TVP récurrentes. Afin de diriger le patient vers une thérapie optimale, la problématique n’est plus basée sur la détection de la thrombose mais plutôt sur l’évaluation de la maturité et de l’âge du thrombus, paramètres qui sont directement corrélées à ses propriétés mécaniques (e.g. élasticité, viscosité). L’élastographie dynamique (ED) a récemment été proposée comme une nouvelle modalité d’imagerie non-invasive capable de caractériser quantitativement les propriétés mécaniques de tissus. L’ED est basée sur l’analyse des paramètres acoustiques (i.e. vitesse, atténuation, pattern de distribution) d’ondes de cisaillement basses fréquences (10-7000 Hz) se propageant dans le milieu sondé. Ces ondes de cisaillement générées par vibration externe, ou par source interne à l’aide de la focalisation de faisceaux ultrasonores (force de radiation), sont mesurées par imagerie ultrasonore ultra-rapide ou par résonance magnétique. Une méthode basée sur l’ED adaptée à la caractérisation mécanique de thromboses veineuses permettrait de quantifier la sévérité de cette pathologie à des fins d’amélioration diagnostique. Cette thèse présente un ensemble de travaux reliés au développement et à la validation complète et rigoureuse d’une nouvelle technique d’imagerie non-invasive élastographique pour la mesure quantitative des propriétés mécaniques de thromboses veineuses. L’atteinte de cet objectif principal nécessite une première étape visant à améliorer les connaissances sur le comportement mécanique du caillot sanguin (sang coagulé) soumis à une sollicitation dynamique telle qu’en ED. Les modules de conservation (comportement élastique, G’) et de perte (comportement visqueux, G’’) en cisaillement de caillots sanguins porcins sont mesurés par ED lors de la cascade de coagulation (à 70 Hz), et après coagulation complète (entre 50 Hz et 160 Hz). Ces résultats constituent les toutes premières mesures du comportement dynamique de caillots sanguins dans une gamme fréquentielle aussi étendue. L’étape subséquente consiste à mettre en place un instrument innovant de référence (« gold standard »), appelé RheoSpectris, dédié à la mesure de la viscoélasticité hyper-fréquence (entre 10 Hz et 1000 Hz) des matériaux et biomatériaux. Cet outil est indispensable pour valider et calibrer toute nouvelle technique d’élastographie dynamique. Une étude comparative entre RheoSpectris et la rhéométrie classique est réalisée afin de valider des mesures faites sur différents matériaux (silicone, thermoplastique, biomatériaux, gel). L’excellente concordance entre les deux technologies permet de conclure que RheoSpectris est un instrument fiable pour la mesure mécanique à des fréquences difficilement accessibles par les outils actuels. Les bases théoriques d’une nouvelle modalité d’imagerie élastographique, nommée SWIRE (« shear wave induced resonance dynamic elastography »), sont présentées et validées sur des fantômes vasculaires. Cette approche permet de caractériser les propriétés mécaniques d’une inclusion confinée (e.g. caillot sanguin) à partir de sa résonance (amplification du déplacement) produite par la propagation d’ondes de cisaillement judicieusement orientées. SWIRE a également l’avantage d’amplifier l’amplitude de vibration à l’intérieur de l’hétérogénéité afin de faciliter sa détection et sa segmentation. Finalement, la méthode DVT-SWIRE (« Deep venous thrombosis – SWIRE ») est adaptée à la caractérisation de l’élasticité quantitative de thromboses veineuses pour une utilisation en clinique. Cette méthode exploite la première fréquence de résonance mesurée dans la thrombose lors de la propagation d’ondes de cisaillement planes (vibration d’une plaque externe) ou cylindriques (simulation de la force de radiation par génération supersonique). DVT-SWIRE est appliquée sur des fantômes simulant une TVP et les résultats sont comparés à ceux donnés par l’instrument de référence RheoSpectris. Cette méthode est également utilisée avec succès dans une étude ex vivo pour l’évaluation de l’élasticité de thromboses porcines explantées après avoir été induites in vivo par chirurgie. / The venous thromboembolism such as the lower limb deep venous thrombosis (DVT) is a vascular pathology characterized by a blood clot formation that induces partial or total vessel lumen occlusion. Pulmonary embolism is a fatal complication of DVT where the clot detaches from the wall, circulates in the blood flow, and produces an obstruction of pulmonary arterial branches. The combination of clinical prediction rules (signs or symptoms) and blood tests (D-dimer testing) coupled to venous ultrasonography (i.e. compression ultrasonography, color Doppler) allows an accurate diagnosis of first DVT. Nevertheless, such clinical tools present poor results to detect recurrent thrombotic events. Then, in order to guide patients towards optimal therapy, the problem is no more to detect the presence of thrombus, but to evaluate its maturity and its age, which are correlated to their mechanical properties (e.g. elasticity, viscosity). The dynamic elastography (DE) has been recently proposed as a novel non-invasive imaging modality capable to characterize the quantitative mechanical properties of tissues. The DE is based on the analysis of acoustical parameters (i.e. velocity, attenuation, wave pattern) of low frequency (10-7000 Hz) shear waves propagating within the probed medium. Such shear waves generated by external vibration, or remotely using ultrasound beam focalisation (radiation force), were tracked using ultra-fast ultrasound or magnetic resonance imaging. A method based on DE and adapted to mechanical characterization of venous thrombosis may allow the quantification of diseases severity in order to improve the final diagnosis. This thesis presents the works related to the development and complete validation of a novel non-invasive elastography imaging method for the quantitative and reliable estimation of mechanical properties of venous thrombosis. In order to fulfil the main objective, it is first necessary to improve knowledge about mechanical behaviours of blood clot (coagulated blood) subjected to a dynamic solicitation similar to DE. The shear storage (elastic behaviour, G’) and loss (viscous behavior, G’’) moduli of porcine blood clots are measured by DE during the blood coagulation kinetics (at 70 Hz) and after completely coagulation (between 50 Hz and 160 Hz). These results are the first dynamic behaviour measurements of blood clots in such wide frequency range. The subsequent step consists in introducing an innovative reference instrument (« gold standard »), called RheoSpectris, dedicated to measure the hyper-frequency viscoelasticity (between 10 Hz and 1000 Hz) of materials and biomaterials. This tool is indispensable to validate new dynamic elastography techniques. A comparative study between RheoSpectris and classical rheometry is performed to validate the measurements on different materials (silicon, thermoplastic, biomaterials, gel). The excellent agreement between both technologies allows to conclude that RheoSpectris is a reliable instrument for mechanical measurements at high frequencies, which is not always possible with current tools. The theoretical basis of a novel elastographic imaging modality, labelled SWIRE (« shear wave induced resonance dynamic elastography ») is presented and validated on vascular phantoms. Such approach allows the characterization of mechanical properties of a confined inclusion (e.g. blood clot) from its resonance (displacement amplification) due to the propagation of judiciously oriented shear waves. SWIRE has also the advantage to amplify the vibration amplitude within the heterogeneity to help for its detection and segmentation. Finally, the method DVT-SWIRE ((« Deep venous thrombosis – SWIRE ») is adapted to the quantitative elasticity estimation of venous thrombosis in the context of clinical use. DVT-SWIRE exploits the first resonance frequency measured within the thrombosis during the plane (vibration of rigid plate) or cylindrical (simulating supersonic radiation force generation) shear waves propagation. The technique is applied on DVT phantoms and the results are compared to those given by the RheoSpectris reference instrument. This method is also used successfully in an ex vivo study for the elasticity assessment of explanted porcine thrombosis surgically induced in vivo.

Page generated in 0.0621 seconds