• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 33
  • 14
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caracterização química, física e isotópica de Usub(3)Sisub(2) para fins forenses nucleares / Chemical, physical and isotopic characterization of Usub(3)Sisub(2) for nuclear forensics purposes

ROSA, DANIELE S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:09Z (GMT). No. of bitstreams: 0 / No início dos anos 90, os primeiros indícios do tráfico ilícito de materiais nucleares e radioativos foram observados principalmente na região européia. Uma década marcada por inúmeros casos de apreensão desse tipo de material. Como resultado, esses atos passaram a ser alvo de investigações criminais forenses, desenvolvendo-se a partir daí, a ciência forense nuclear. No Brasil não há registros oficiais do tráfico ilícito de material nuclear, entretanto, é amplamente conhecida a extração e o transporte ilegal de materiais geológicos radioativos, assim como a apreensão de fragmentos de materiais utilizados como blindagem de fontes radioativas. Uma das principais ferramentas utilizadas na ciência forense nuclear consiste no estabelecimento de bancos de dados de materiais nucleares. Esses documentos devem conter o maior número possível de informações sobre as características físicas, químicas e nucleares do material apreendido, permitindo a identificação de sua origem, processo de fabricação ou mesmo a idade (age). Assim, se estabelecem padrões de composição característicos de cada material, denominados assinaturas químicas (chemical finger print). Nesse trabalho foi adotado o protocolo forense nuclear seguindo as três etapas de avaliação sugeridas pela Agência Internacional de Energia Atômica (AIEA) na identificação da origem de Siliceto de urânio (U3Si2). Realizaram-se ensaios de caracterização física, química e isotópica dos materiais em estudo e compararam-se os dados com aqueles obtidos para outros compostos de urânio (Tetrafluoreto de urânio, UF4; óxidos de urânio, UO2 e U3O8; tricarbonato de amônio e uranila, TCAU) estabelecendo-se uma assinatura característica para cada um. A partir dos resultados foi possível classificar os compostos por grupos de origem, uma vez que são provenientes de diferentes processos de fabricação e/ ou origem. Demonstrou-se também a importância da criação e manutenção de um banco de dados nuclear na investigação de um evento forense nuclear. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
12

Desenvolvimento do plano preliminar de descomissionamento do reator IPEN/MB-01 / Preliminary decommissioning plan of the reactor IPEN/MB-01

VIVAS, ARY de S. 20 February 2015 (has links)
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-02-20T15:58:48Z No. of bitstreams: 0 / Made available in DSpace on 2015-02-20T15:58:48Z (GMT). No. of bitstreams: 0 / Em todo mundo, muitas instalações nucleares foram construídas e necessitarão serem desligadas em um determinado momento por estarem próximas do seu tempo recomendado de utilização que é de aproximadamente 40 anos. A AIEA (Agência Internacional de Energia Atômica) busca orientar e recomendar uma série de diretrizes para a realização de atividades de descomissionamento de instalações nucleares, com atenção especial aos países que não possuem um quadro regulatório legal que ampare as atividades de descomissionamento. O Brasil, até o momento, não possui uma norma específica que oriente as etapas de descomissionamento de reatores de pesquisa. Entretanto, em março de 2011 foi constituída uma comissão de estudo com a atribuição principal voltada às questões de descomissionamento das instalações nucleares brasileiras, culminando na resolução 133, de 8 de novembro de 2012, um projeto de norma que dispõe sobre o Descomissionamento de Usinas Nucleoelétricas. O Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui dois reatores de pesquisa sendo um deles o reator IPEN/MB-01. O objetivo dessa dissertação de mestrado é elaborar um plano preliminar de descomissionamento desse reator de pesquisa, considerando a documentação técnica da instalação (RAS-Relatório de Análise de Segurança), as normas existentes da CNEN (Comissão Nacional de Energia Nuclear), assim como as recomendações da AIEA. Em termos de procedimentos de descomissionamento para reatores de pesquisa, este trabalho se baseou no que existe de mais moderno em experiências, estratégias e lições aprendidas realizadas e documentadas nas publicações da AIEA que abrangem técnicas e tecnologias de descomissionamento. Considerando estes conhecimentos técnicos e às peculiaridades da instalação, foi selecionada a estratégia de desmantelamento imediato, que corresponde ao inicio das atividades de descomissionamento assim que a instalação for desligada, dividindo-a em setores de trabalho. Como recurso de gerenciamento e acompanhamento do projeto de descomissionamento do reator e manutenção de registros, foi desenvolvido um banco de dados utilizando o programa Microsoft Access 2007, no qual contêm todos os itens e informações referentes ao plano preliminar de descomissionamento. O trabalho aqui descrito busca atender os requisitos, critérios técnicos e institucionais, incorporando o que se tem de mais atual em procedimentos de descomissionamento, podendo servir como guia para as demais instalações brasileiras. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
13

Role komerčního pojištění při řešení důsledků jaderných rizik / Role of commercial insurance in solving consequences of nuclear risks

Zindulka, Martin January 2016 (has links)
This thesis aims on solving consequences of nuclear accidents in nucler power plants through commercial insurance. First part of this work introduces internationl liability framework for nuclear accidents, which contains international nuclear threaties and work of International Atomic Energy Agency, altogether with work of czech Agency for nuclear security. Next chapters describe nuclear insurance pools, with special focus on american pool American Nuclear Insurers and Czech nuclear insurance pool. Final part of this thesis goes through two big nuclear accidents in Three Mile Island power plant and in Fukushima power plant. Both accidents are described in wide perspective, including solving and financing of consequences from nuclear insurance and from other financial sources available at the time of disaster.
14

Aplicação do método k0-INAA no Laboratório de Análise por Ativação com Nêutrons do IPEN utilizando o programa k0-IAEA. Análise de amostras biológicas. / k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program. Biological sample analysis

Daniel Correa Puerta 14 June 2013 (has links)
Este estudo apresenta os resultados obtidos na aplicação do método de padronização k0-INAA no LANIPEN, para a análise de amostras biológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). Os parâmetros de fluxo f e α do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação e na posição de irradiação 24B/prateleira2, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr- 94Zr. Para a verificação da precisão e exatidão do método, foram analisados os materiais biológicos de referência Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a). Os critérios estatísticos Erro Relativo (bias, %), Coeficiente de Variação (CV) e U-score foram aplicados para avaliação dos resultados obtidos (média de seis replicatas). Os erros relativos (bias, %) ficaram, para maioria dos elementos, entre 0 e 30%, em relação aos valores certificados. Os Coeficientes de Variação foram inferiores a 20%, mostrando boa reprodutibilidade nos resultados obtidos experimentalmente. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Na no Peach Leaves e no Tomato Leaves, estão dentro de um intervalo de confiança de 95%. Estes resultados apontam para uma promissora utilização do método k0-INAA no LAN-IPEN para a análise de amostras biológicas. / The results obtained in the application of the k0-standardization method at LAN-IPEN for biological matrices analysis, by using the k0-IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and α of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197Au-96Zr-94Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The Uscore test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k0-INAA method at LAN-IPEN for biological sample analysis.
15

Aplicação do método k0-INAA no Laboratório de Análise por Ativação com Nêutrons do IPEN utilizando o programa k0-IAEA. Análise de amostras biológicas. / k0-INAA application at IPEN Neutron Activation Laboratory by using the k0-IAEA program. Biological sample analysis

Puerta, Daniel Correa 14 June 2013 (has links)
Este estudo apresenta os resultados obtidos na aplicação do método de padronização k0-INAA no LANIPEN, para a análise de amostras biológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). Os parâmetros de fluxo f e α do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação e na posição de irradiação 24B/prateleira2, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr- 94Zr. Para a verificação da precisão e exatidão do método, foram analisados os materiais biológicos de referência Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a). Os critérios estatísticos Erro Relativo (bias, %), Coeficiente de Variação (CV) e U-score foram aplicados para avaliação dos resultados obtidos (média de seis replicatas). Os erros relativos (bias, %) ficaram, para maioria dos elementos, entre 0 e 30%, em relação aos valores certificados. Os Coeficientes de Variação foram inferiores a 20%, mostrando boa reprodutibilidade nos resultados obtidos experimentalmente. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Na no Peach Leaves e no Tomato Leaves, estão dentro de um intervalo de confiança de 95%. Estes resultados apontam para uma promissora utilização do método k0-INAA no LAN-IPEN para a análise de amostras biológicas. / The results obtained in the application of the k0-standardization method at LAN-IPEN for biological matrices analysis, by using the k0-IAEA software, provided by the International Atomic Energy Agency (IAEA), are presented. The flux parameters f and α of the IEA-R1 reactor were determined for the pneumatic irradiation facility and for one selected irradiation position, 24B/shelf2, for short and long irradiations, respectively. In order to obtain these parameters, the bare triple-monitor method with 197Au-96Zr-94Zr was used. In order to evaluate the accuracy and precision of the methodology, the biological reference materials Peach Leaves (NIST SRM 1547), Mixed Polish Herbs (INCT-MPH-2) e Tomato Leaves (NIST SRM 1573a) were analyzed. The statistical criteria Relative Errors (bias, %), Coefficient of Variation (CV) and U-score were applied to the obtained results (mean of six replicates). The relative errors (bias, %) in relation to certified values, were, for most elements, in the range of 0 e 30. The Coefficients of Variation were below 20%, showing a good reproducibility of the results. The Uscore test showed that all results, except Na in Peach Leaves and in Tomato Leaves, were within 95% confidence interval. These results point out to a promising use of the k0-INAA method at LAN-IPEN for biological sample analysis.
16

Implantação do novo protocolo de dosimetria da AIEA no LCI/IPEN/CNEN / Implementation of the new IAEA code of practice at LCI/IPEN/CNEN

Siqueira, Patricia Mára de 22 August 2006 (has links)
A fim de implementar o novo código de prática da Agência Internacional de Energia Atômica (AIEA) no Brasil, o Laboratório de Calibração de Instrumentos (LCI/IPEN) está realizando calibrações em termos de kerma no ar e em termos de dose absorvida na água, em feixes de 60Co. As razões ND,w/NK obtidas são comparadas com valores da literatura, obtendo-se concordância satisfatória. As diferenças entre os valores das razões CK (ND,w/NK) obtidas no presente trabalho e os valores da literatura são devidas a vários fatores. Estes fatores podem ser as variações entre as câmaras, que devem ser objeto de diferenças nas incertezas estimadas pelos PSDLs, e as diferenças nos padrões utilizados por cada Instituto de Metrologia Nacional (NMI) ou Laboratório de Dosimetria. No entanto, se forem conhecidas as razões entre cada NMI e o BIPM, para os padrões de kerma no ar e de dose absorvida na água, é possível a normalização das razões CK medidas para as razões equivalentes ao BIPM. Todos os resultados de razões CK obtidos foram convertidos para as razões equivalentes ao BIPM para facilitar a comparação. Neste trabalho é discutida a utilização da razão CK como parâmetro de controle de qualidade na verificação de resultados das calibrações rotineiras. Para avaliação dos procedimentos de calibração adotados no LCI, foram realizados testes de estabilidade a longo prazo com as câmaras de ionização padrões. Além disso, foi criado um banco de dados para armazenamento dos dados de calibração, com o objetivo de melhorar a qualidade do procedimento de calibração. / In order to implement the new IAEA code of practice in Brazil the national calibration laboratories, the Laboratory of Instrument Calibration (LCI/IPEN) is calibrating clinical dosimeters in terms of both air kerma and absorbed dose to water in a 60Co gamma ray beam. The ND,w/NK ratios thus obtained are then compared with the literature values; a satisfactory agreement has been found. The differences between the CK values obtained in the present work and the literature values may be due to several components. These could be the chamber-to-chamber variations which may be subject to different estimated uncertainties by PSDLs, and the variations in the standards used by each National Metrology Institute (NMI) or Dosimetry Laboratory. However, since the ratio of both air kerma and absorbed dose to water standards for each NMI to those of the BIPM are known, it is possible to reduce the measured ratios to the expected BIPM equivalent ratios. All these CK results have been converted to the BIPM equivalent values to facilitate comparison. The use of the CK value as a and quality control parameter to verify the results of the routine calibrations is discussed in this work. The long term stability of wich standard ionization chamber was checked in order to evaluate the calibration procedures followed at LCI. Moreover, a database was created to store the calibration data aiming the quality improvement of the calibration procedure.
17

Implantação do novo protocolo de dosimetria da AIEA no LCI/IPEN/CNEN / Implementation of the new IAEA code of practice at LCI/IPEN/CNEN

Patricia Mára de Siqueira 22 August 2006 (has links)
A fim de implementar o novo código de prática da Agência Internacional de Energia Atômica (AIEA) no Brasil, o Laboratório de Calibração de Instrumentos (LCI/IPEN) está realizando calibrações em termos de kerma no ar e em termos de dose absorvida na água, em feixes de 60Co. As razões ND,w/NK obtidas são comparadas com valores da literatura, obtendo-se concordância satisfatória. As diferenças entre os valores das razões CK (ND,w/NK) obtidas no presente trabalho e os valores da literatura são devidas a vários fatores. Estes fatores podem ser as variações entre as câmaras, que devem ser objeto de diferenças nas incertezas estimadas pelos PSDLs, e as diferenças nos padrões utilizados por cada Instituto de Metrologia Nacional (NMI) ou Laboratório de Dosimetria. No entanto, se forem conhecidas as razões entre cada NMI e o BIPM, para os padrões de kerma no ar e de dose absorvida na água, é possível a normalização das razões CK medidas para as razões equivalentes ao BIPM. Todos os resultados de razões CK obtidos foram convertidos para as razões equivalentes ao BIPM para facilitar a comparação. Neste trabalho é discutida a utilização da razão CK como parâmetro de controle de qualidade na verificação de resultados das calibrações rotineiras. Para avaliação dos procedimentos de calibração adotados no LCI, foram realizados testes de estabilidade a longo prazo com as câmaras de ionização padrões. Além disso, foi criado um banco de dados para armazenamento dos dados de calibração, com o objetivo de melhorar a qualidade do procedimento de calibração. / In order to implement the new IAEA code of practice in Brazil the national calibration laboratories, the Laboratory of Instrument Calibration (LCI/IPEN) is calibrating clinical dosimeters in terms of both air kerma and absorbed dose to water in a 60Co gamma ray beam. The ND,w/NK ratios thus obtained are then compared with the literature values; a satisfactory agreement has been found. The differences between the CK values obtained in the present work and the literature values may be due to several components. These could be the chamber-to-chamber variations which may be subject to different estimated uncertainties by PSDLs, and the variations in the standards used by each National Metrology Institute (NMI) or Dosimetry Laboratory. However, since the ratio of both air kerma and absorbed dose to water standards for each NMI to those of the BIPM are known, it is possible to reduce the measured ratios to the expected BIPM equivalent ratios. All these CK results have been converted to the BIPM equivalent values to facilitate comparison. The use of the CK value as a and quality control parameter to verify the results of the routine calibrations is discussed in this work. The long term stability of wich standard ionization chamber was checked in order to evaluate the calibration procedures followed at LCI. Moreover, a database was created to store the calibration data aiming the quality improvement of the calibration procedure.
18

Desenvolvimento de metodologias utilizadas nas áreas de salvaguardas e forense nuclear baseadas na técnica LA-HR-ICP-MS / Development of methodologies used in Safeguards and Nuclear Forensics based on LA-HR-ICP-MS technique.

MARIN, RAFAEL C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:15Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
19

Implantação de um programa de controle de qualidade para sistemas de planejamento de tratamento computadorizados de acordo com o TRS 430

CAMARGO, PRISCILLA R.T.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:11Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
20

Desenvolvimento de metodologias utilizadas nas áreas de salvaguardas e forense nuclear baseadas na técnica LA-HR-ICP-MS / Development of methodologies used in Safeguards and Nuclear Forensics based on LA-HR-ICP-MS technique.

MARIN, RAFAEL C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:15Z (GMT). No. of bitstreams: 0 / A amostragem ambiental por esfregaço ou swipe samples é uma metodologia que vem sendo empregada rotineiramente pela Agência Internacional de Energia Atômica (AIEA) para verificar se os Estados signatários do Acordo de Salvaguardas estão realizando atividades nucleares não declaradas. A análise dessas amostras ambientais é complementar aos procedimentos de salvaguardas convencionais para a verificação das informações cedidas pelos Estados. Neste trabalho, foi descrita uma metodologia que visa a fortalecer os processos de salvaguarda nuclear e da ciência forense nuclear no país. A proposta é estudar e avaliar a técnica de ablação à laser acoplada a um espectrômetro de massa de alta resolução com fonte de plasma indutivamente acoplado (LA-HR-ICP-MS Laser Ablation High Resolution Inductively Coupled Plasma Mass Spectrometry), como técnica alternativa para a análise das amostras de esfregaço. Adicionalmente, foram empregadas outras técnicas complementares (atividade radioativa, microscopia eletrônica de varredura e espectroscopia de energia dispersiva) com o intuito de garantir maior segurança ao processo de inspeção de salvaguardas e investigações forenses nucleares. A precisão, medida através do desvio padrão relativo (DPR),dos resultados obtidos para as razões isotópicas 234U/238U, 235U/238U e 236U/238U do padrão analisado (CRM -125A) para a medida do fator de discriminação de massa foram, respectivamente, 1,3 %, 0,2 % e 7,6 %. Já as incertezas percentuais (u %), que também contemplam o DPR das medições, variaram de 3,5 % a 29,8 % para as medições da razão isotópica 235U/238U e de 16,6 % a 42,9 % para a razão isotópica 234U/238U. Esses valores mostraram-se compatíveis com outros estudos que utilizaram a mesma técnica para análise de amostras reais coletadas em uma instalação nuclear. As amostras coletadas apresentaram nível de enriquecimento que variou de (2,3 ± 0,7) % (amostra 3 corredor de acesso à instalação) a (17,3 ± 2,8) % (amostra 18 bancada de recuperação de UF4). A partir da coleta de amostras nesses diversos pontos, desde a entrada da instalação até a bancada em que se manuseia o urânio enriquecido, foi possível detectar diversos níveis de enriquecimento no isótopo 235U. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0542 seconds