• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 3
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Towards Development of Smart Nanosensor System To Detect of Hypoglycemia From Breath

Thakur, Sanskar S. 05 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The link between volatile organic compounds (VOCs) from breath and various diseases and specific conditions has been identified since long by the researchers. Canine studies and breath sample analysis on Gas chromatography/ Mass Spectroscopy has proven that there are VOCs in the breath that can detect and potentially predict hypoglycemia. This project aims at developing a smart nanosensor system to detect hypoglycemia from human breath. The sensor system comprises of 1-Mercapto-(triethylene glycol) methyl ether functionalized goldnanoparticle (EGNPs) sensors coated with polyetherimide (PEI) and poly(vinylidene fluoride -hexafluoropropylene) (PVDF-HFP) and polymer composite sensor made from PVDF-HFP-Carbon Black (PVDF-HFP/CB), an interface circuit that performs signal conditioning and amplification, and a microcontroller with Bluetooth Low Energy (BLE) to control the interface circuit and communicate with an external personal digital assistant. The sensors were fabricated and tested with 5 VOCs in dry air and simulated breath (a mixture of air, small portion of acetone, ethanol at high humidity) to investigate sensitivity and selectivity. The name of the VOCs is not disclosed herein but these VOCs have been identified in-breath and are identified as potential biomarkers for other diseases as well. The sensor hydrophobicity has been studied using contact angle measurement. The GNPs size was verified using Ultra-Violent-Visible (UV-VIS) Spectroscopy. Field Emission Scanning Electron Microscope (FESEM) image is used to show GNPs embedded in the polymer film. The sensors sensitivity increases by more than 400\% in an environment with relative humidity (RH) of 93\% and the sensors show selectivity towards VOCs of interest. The interface circuit was designed on Eagle PCB and was fabricated using a two-layer PCB. The fabricated interface circuit was simulated with variable resistance and was verified with experiments. The system is also tested at different power source voltages and it was found that the system performance is optimum at more than 5 volts. The sensor fabrication, testing methods, and results are presented and discussed along with interface circuit design, fabrication, and characterization. / 2022-05-8
12

A microcontroller-based Electrochemical Impedance Spectroscopy Platform for Health Monitoring Systems

Bhatnagar, Purva 16 October 2015 (has links)
No description available.
13

Micromachined flow sensors for velocity and pressure measurement

Song, Chao 27 August 2014 (has links)
This research focuses on developing sensors for properties of aerodynamic interest (i.e., flow and pressure) based on low-cost polymeric materials and simple fabrication processes. Such sensors can be fabricated in large arrays, covering the surface of airfoils typically used in unmanned vehicles, allowing for the detection of flow separation. This in turn potentially enables, through the use of closed-loop control, an expansion of the flight envelope of these vehicles. A key advance is compensation for the typically inferior performance of these low cost materials through both careful design as well as new readout methods that reduce drift, namely a readout methodology based on aeroelastic flutter. An all-polymer micromachined piezoresistive flow sensor is fabricated, based on a flexible polyimide substrate and an elastomeric piezoresistive composite material. The flow sensor comprises a cantilever that is extended into the embedding flow; flow-induced stress on the cantilever is sensed through the piezoresistive composite material. Increasing the sensitivity of the sensor is achieved by either utilizing a long single-cantilever beam or using a dual-cantilever beam supporting a flap extending into the flow. In the latter case, the sensor demonstrates increased sensitivity with a reduced cantilever length. The increase in sensitivity helps to reduce sensor drift, which in turn is further reduced by a new measurement method, the vibration amplitude measurement method. In this drift reduction measurement method, the flow-induced vibration amplitude of the sensor structure (i.e., the amplitude of the aeroelastic flutter induced by the flow), instead of the absolute value of cantilever deflection, is measured in order to find the flow rate. Measurement of this relative resistance change instead of the absolute resistance in the piezoresistor rejects common-mode drift and greatly reduces overall drift. Experimental results verify the expected drift reduction. Sensor drift is also reduced when the elastomeric piezoresistive material is replaced by a Pt thin film piezoresistor. Development of pressure sensors based on polymers proceeds by encapsulating a reference cavity within a multilayer polymer structure and forming capacitor plates on the polymeric membranes encapsulating the cavity. Measuring the capacitance change induced by changes in the embedding pressure (which cause changes in the positions of the bounding polymeric membranes) enables calculation of the pressure. The use of polymeric membranes requires understanding the leakage rate of gas into the reference cavity, which is a source of pressure drift. Developing a polymer-based pressure sensor that solves the problem of sensor drift as a result of gas permeation entails the fabrication of a silicon pressure reference cavity embedded in the polymer substrate, which results in a more hermetic and lower drift sensor while preserving the flexibility of the embedding polymer. Both wired and wireless versions of pressure and flow sensors of these types were developed and characterized. Further, the sensors were characterized on airfoils and their performance in a wind tunnel was determined.
14

Řízení obvodu účastnického rozhraní / Subscriber Line Interface Circuit Control

Havran, Josef January 2008 (has links)
The aim of this thesis is to design a connection of the development kit for the subscriber line interface circuit Si3220 with the development kit for the digital signal processor DSP56858EVM and implement a test application, which will allow us to use the development kit as a small private branch exchange. The application allows us to operate up to ten telephone machines and it disposes of basic telephone exchange functions -- generating tones to the headphone, detecting the DTMF dialing, generating the ringing and the voice connection of the subscribers.
15

Towards Development of Smart Nanosensor System To Detect Hypoglycemia From Breath

Sanskar S Thakur (8816885) 08 May 2020 (has links)
<div>The link between volatile organic compounds (VOCs) from breath and various diseases and specific conditions has been identified since long by the researchers. Canine studies and breath sample analysis on Gas chromatography/ Mass Spectroscopy has proven that there are VOCs in the breath that can detect and potentially predict hypoglycemia. This project aims at developing a smart nanosensor system to detect hypoglycemia from human breath. The sensor system comprises of 1-Mercapto-(triethylene glycol) methyl ether functionalized goldnanoparticle (EGNPs) sensors coated with polyetherimide (PEI) and poly(vinylidene fluoride -hexafluoropropylene) (PVDF-HFP) and polymer composite sensor made from PVDF-HFP-Carbon Black (PVDF-HFP/CB), an interface circuit that performs signal conditioning and amplification, and a microcontroller with Bluetooth Low Energy (BLE) to control the interface circuit and communicate with an external personal digital assistant. The sensors were fabricated and tested with 5 VOCs in dry air and simulated breath (mixture of air, small portion of acetone, ethanol at high humidity) to investigate sensitivity and selectivity. The name of the VOCs is not disclosed herein but these VOCs have been identified in breath and are identified as potential biomarkers for other diseases as well. </div><div> </div><div> The sensor hydrophobicity has been studied using contact angle measurement. The GNPs size was verified using Ultra-Violent-Visible (UV-VIS) Spectroscopy. Field Emission Scanning Electron Microscope (FESEM) image is used to show GNPs embedded in the polymer film. The sensors sensitivity increases by more than 400% in an environment with relative humidity (RH) of 93% and the sensors show selectivity towards VOCs of interest. The interface circuit was designed on Eagle PCB and was fabricated using a two-layer PCB. The fabricated interface circuit was simulated with variable resistance and was verified with experiments. The system is also tested at different power source voltages and it was found that the system performance is optimum at more than 5 volts. The sensor fabrication, testing methods, and results are presented and discussed along with interface circuit design, fabrication, and characterization.</div>
16

Vers une meilleure exploitation des dispositifs de récupération d’énergie vibratoire bistables : Analyse et utilisation de comportements originaux pour améliorer la bande passante / Towards a better exploitation of bistable vibratory energy harveters : Analysis and use of original behaviors to improve bandwidth

Huguet, Thomas 06 December 2018 (has links)
Cette thèse concerne la récupération d'énergie vibratoire dans le but de proposer une alternative aux batteries conventionnelles pour l’alimentation de systèmes autonomes sans fil. Ceci permettrait d’améliorer leur compacité (moins d’énergie stockée), leur tenue dans des environnements sévères (forte température) et de réduire leur besoin d'entretien. Cette étude se concentre plus particulièrement sur les générateurs oscillants bistables, intéressants pour leur grande plage de fréquences utile comparée à celle offerte par les générateurs linéaires (limitée à la zone de résonance). Cette thèse se divise en quatre grandes parties. La première présente la construction du modèle mathématique permettant de prédire les différents comportements du générateur bistable (ces derniers pouvant coexister sur certaines plages de fréquences) incluant l'étude de la stabilité aux petites perturbations. Ce modèle met en évidence des comportements du générateur encore peu exploités pour la récupération d'énergie : les comportements sous-harmoniques dont la plage de fréquences permet d'agrandir la bande passante globale du générateur. Afin d’améliorer la précision du modèle, celui-ci est ensuite complété dans la deuxième partie par un critère semi-analytique : le critère de robustesse de stabilité qui caractérise la sensibilité du générateur aux perturbations extérieures (plus un comportement est robuste plus il sera facile à maintenir dans le temps). Le modèle ainsi obtenu ainsi que le système expérimentale montrent une grande plage de fréquences sur laquelle coexistent des comportements intéressants pour la récupération d’énergie (les orbites hautes) et des comportements non désirables (les orbites basses). La troisième partie de cette thèse présente donc différentes stratégies permettant de sauter des orbites basses vers les orbites hautes en jouant directement sur les paramètres du générateur. Enfin, la quatrième et dernière partie s’attarde sur l’influence du circuit d'interface AC-DC entre le générateur bistable et la charge en vue de son intégration future. / This thesis concerns vibratory energy harvesting in order to propose an alternative to conventional batteries for the power supply of autonomous wireless systems. This would improve their compactness (less stored energy), their resistance to harsh environments (high temperature) and reduce their need for maintenance. This study focuses in particular on bistable oscillating generators, which are interesting for their large useful frequency range compared to that offered by linear generators (limited to the resonance zone). This thesis is divided into four main parts. The first presents the construction of the mathematical model to predict the different behaviors of the bistable generator (these behaviors can coexist over certain frequency ranges) including the study of stability to small disturbances. This model highlights original behaviors for energy recovery: subharmonic behaviors whose frequency range allows increasing the overall generator bandwidth. In order to improve the accuracy of the model, a semi-analytical criterion is then added: the stability robustness criterion which characterizes the sensitivity of the different behaviors to external disturbances (the more robust a behavior, the easier to maintain over time). The model obtained and the experimental prototype show a wide frequency range on which the interesting behaviors (high orbits) and the undesirable behaviors (low orbits) coexist. The third part of this thesis therefore presents different strategies for jumping from low to high orbits by playing directly on the generator parameters. Finally, the fourth and last part focuses on the influence of the AC-DC interface circuit between the bistable generator and the load for future integration.

Page generated in 0.1012 seconds