• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 1
  • Tagged with
  • 24
  • 20
  • 9
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Návrh optického vláknového senzoru pro detekci vibrací / Design of optical fiber sensor for vibration detection

Janoušek, Adam January 2020 (has links)
The master theses deals with a detailed analysis of optical fiber sensors. Specifically, there are discussed optical fibers, various types of sensors and realization optical fiber senzor and senzor system that has been optimized and processed data in real time. In master theses also describes the LabView programming enviroment and uses components, including the entire sensor systém of a sensors system that sends measured data
22

Vyjadřování nejistoty u přesných délkových měření II / Expressing uncertainty of accurate lenght measurement II

Šrámek, Jan January 2011 (has links)
This diploma thesis is supposed to inform readers interested in the distance measurements uncertainty on practical issues connected with the solving of these troubles when utilising a frequently used calibration method - the Tesa NPL measure instrument. This measuring was implemented by the Czech Metrologic Institute, where the author works; therefore he could take advantage of his rich experience as well as experience of his superiors and colleagues. The author regards the national metrological institute (CMI) as a sufficient guarantee for the hereinafter presented materials, both regarding the professional qualification and from the perspective of formal rightness of this thesis.
23

Vývoj lineárního posuvu pro UHV STM/AFM / Development of a linear stage actuator for UHV STM/AFM

Pavelec, Jiří January 2011 (has links)
The aim of this diploma thesis is to develop a linear positioning stage for Ultra High Vacuum (UHV) environment. Simple prototypes of the linear positioning stage were designed and incorporated as part of a multiaxis sample manipulator for a UHV Scanning Tunneling Microscopy / Atomic Force Microscopy (STM/AFM). Different types of position encoders and linear guideways are discussed. Implementation of the homodyne interferometer as an optimization tool for a slip-stick based linear stage is described. Scalar diffraction theory is used to model the diffraction grating optical position encoder behavior.
24

Koherencí řízený holografický mikroskop / COHERENCE-CONTROLLED HOLOGRAPHIC MICROSCOPE

Kolman, Pavel January 2010 (has links)
ransmitted-light coherence-controlled holographic microscope (CCHM) based on an off-axis achromatic and space-invariant interferometer with a diffractive beamsplitter has been designed, constructed and tested. It is capable to image objects illuminated by light sources of arbitrary degree of temporal and spatial coherence. Off-axis image-plane hologram is recorded and the image complex amplitude (intensity and phase) is reconstructed numerically using fast Fourier transform algorithms. Phase image represents the optical path difference between the object and the reference arms caused by presence of an object. Therefore, it is a quantitative phase contrast image. Intensity image is confocal-like. Optical sectioning effect induced by an extended, spatial incoherent light source is equivalent to a conventional confocal image. CCHM is therefore capable to image objects under a diffusive layer or immersed in a turbid media. Spatial and temporal incoherence of illumination makes the optical sectioning effect stronger compared to a confocal imaging process. Object wave reconstruction from the only one recorded interference pattern ensures high resistance to vibrations and medium or ambience fluctuations. The frame rate is not limited by any component of the optical setup. Only the detector and computer speeds limit the frame rate. CCHM therefore allows observation of rapidly varying phenomena. CCHM makes the ex-post numerical refocusing possible within the coherence volume. Coherence degree of the light source in CCHM can be adapted to the object and to the required image properties. More coherent illumination provides wider range of numerical refocusing. On the other hand, a lower degree of coherence makes the optical sectioning stronger, i.e. the optical sections are thiner, it reduces coherence-noise and it makes it possible to separate the ballistic light. In addition to the ballistic light separation, CCHM enables us to separate the diffused light. Multi-colour-light

Page generated in 0.0958 seconds