• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Untersuchungen zur Beanspruchung der Patella

Blauth, Michael, January 1983 (has links)
Thesis (doctoral)--Kiel, 1983.
2

Primäre Ausrissfestigkeit implantatfreier patellarer Fixationsmethoden beim MPFL-Ersatz am porcinen Modell / Primary fixation strength of patellar fixation methods for medial patellofemoral ligament reconstruction in a porcine model

Grüninger, Daniel January 2022 (has links) (PDF)
Akute Patellaluxationen sind häufige Kniegelenksverletzungen. Sie gehen oft mit einer Verletzung des medialen patellofemoralen Ligaments (MPFL) einher, was zu rezidivierenden Patellaluxationen und patellofemoraler Instabilität führen kann. Ein möglicher Therapieansatz ist die Rekonstruktion des MPFL. Zahlreiche Operationstechniken sind hierzu in der Literatur beschrieben, darunter Fixationen mit Interferenzschrauben, Bohrkanälen, Nahtankern oder Nahtfixationen am Knochen oder Weichgewebe. Sie werden meist mit einem autologen Sehnentransplantats durchgeführt und unterscheiden sich hauptsächlich in der Art dessen patellarer Fixation. Meta-Analysen zeigen nach wie vor hohe Komplikationsraten und teilweise wenig zufriedenstellende Ergebnisse etablierter MPFL-Rekonstruktionen. Ein vielversprechender Ansatz zur Senkung der Komplikationsraten sind patellare Fixationsmethoden, die auf das Einbringen von Fremdmaterial und Bohrungen durch die Patella verzichten. Solche implantat- und/oder bohrkanalfreien Fixationsmethoden sind bereits in der Literatur beschrieben, bis jetzt existieren jedoch nur wenige Studien zu deren biomechanischen Eigenschaften. Ziel dieser Arbeit war der Vergleich biomechanischer Eigenschaften von fünf unterschiedlichen implantatfreien patellaren Fixationsmethoden beim MPFL- Ersatz mit dem nativen MPFL und mit nativen Extensorensehnen. Dazu wurde ein porcines Modell benutzt. Die Hypothese dieser Studie war, dass die patellare Weichteilfixation eines autologen Sehnentransplantats ohne Implantate oder Bohrkanal eine vergleichbare primäre Ausrissfestigkeit wie das native MPFL zeigt. 60 Patellae und Extensorensehnen wurden aus porcinen Hinterläufen extrahiert und randomisiert auf 6 Versuchsgruppen aufgeteilt (n=10). In den Gruppen 1 und 2 wurden patellare Weichteilfixationen getestet. In den Gruppen 3 und 4 wurden Bohrkanalfixationen mit unterschiedlichem Nahtmaterial durchgeführt (Gruppe 3: resorbierbarer Faden der Stärke USP 0, Gruppe 4: nicht-resorbierbarer Faden der Stärke USP 3). In Gruppe 5 erfolgte die patellare Fixation mittels V-förmigen Bohrkanal mit Durchmesser von 4,5 mm. In der sechsten Versuchsgruppe wurde zum Vergleich das native Gewebe getestet. In einer weiteren Versuchsgruppe wurden native porcine Extensorensehnen biomechanisch untersucht. Die biomechanische Testung gliederte sich in mehrere Abschnitte. Zunächst erfolgte eine Präkonditionierung mit 10 Setzzyklen mit einem Kraftintervall von 5 - 20 N. Es folgte eine zyklische Testphase von 1000 Messzyklen mit einem Kraftintervall von 5 - 50 N. Im Anschluss wurde die maximale Kraft bis zum Versagen angewendet. Dabei wurden die Parameter maximale Ausrisskraft, Yield Load, Steifigkeit, Elongation nach 1000 Zyklen sowie die Versagensart untersucht. In der Versuchsgruppe des nativen Gewebes wurde direkt die maximale Kraft bis zum Versagen angewendet. Die höchsten maximalen Ausrisskräfte wurden in Gruppen 1 und 2 gemessen (321,8 ± 53,5 N und 242,0 ± 57,4 N) und waren mit dem nativen Gewebe vergleichbar (252,1 ± 129,3 N, p > 0,05). Ein signifikant niedrigerer Yield Load im Vergleich zum nativen Gewebe zeigte sich in den Gruppen 3 (p < 0,01) und 4 (p = 0,01). Während der zyklischen Belastung war die Elongation der Präparate in Gruppe 3 signifikant höher im Vergleich zu den anderen Gruppen (5,3 ± 1 mm, p < 0,05). Alle Gruppen wiesen ähnliche Steifigkeiten wie das native Gewebe vor (p > 0,05). Die getesteten Fixationsmethoden zeigten signifikante Unterschiede in ihren biomechanischen Eigenschaften (p < 0,05). Insbesondere die Weichteilfixationen in Gruppen 1 und 2 wiesen adäquate biomechanische Eigenschaften im Vergleich zum nativen Gewebe vor. Durch die Kombination aus geringerer Invasivität, Verzicht auf das Einbringen von Fremdkörpern, einfacher Anwendbarkeit und guter Primärstabilität sind patellare Weichteilfixationen vielversprechende Alternativen bei der MPFL-Rekonstruktion. und guter Primärstabilität sind patellare Weichteilfixationen vielversprechende Alternativen bei der MPFL-Rekonstruktion. / Purpose: The purpose of this study was to compare primary fixation strength and biomechanical properties of five different patellar fixation techniques without implants in medial patellofemoral ligament (MPFL)-reconstruction in a porcine model. Our hypothesis was that patellar fixation with soft tissue suture shows similar primary fixation strength to native MPFL. Methods: 60 domestic porcine patellae and extensor tendons were harvested and randomized into 6 groups. In group 1 and 2 soft tissue suture fixation techniques were used. In group 3 and 4 osseous tunnel reconstruction methods were performed with different sutures (absorbable suture USP 0 and non-absorbable suture USP 3). In group 5 fixation was performed with a v-shaped osseous tunnel with 4.5 mm diameter. In group 6 the stability of the native tissue was tested as comparison. The patella-tendon constructs were preconditioned with 5 cycles between 5 and 20 N with an afterwards cyclic stress testing of 1000 cycles in the range of 5 to 50 N. Subsequently, a maximum load until failure was applied. The native tissue group was solely tested for the maximum load to failure. Results: The highest maximum load to failure was found in group 1 and 2 (321.8 ± 53.5 N and 242.0 ± 57.4 N) and showed comparable results to the native tissue group (252.1 ± 129.3 N, p >0.05). A significantly lower Yield Load was found in group 3 (p=0.003) and 4 (p=0.011). During cyclic testing group 3 resulted in significantly higher elongation compared to the other groups (5.28 ± 1 mm, p <0.05). All groups showed similar stiffness to the native tissue (p >0.05). Conclusion: The examined implantfree patellar fixation methods differ significantly in their biomechanical properties (p <0.05). Adequate maximum values of Fmax compared to the native tissue were observed. Implantfree fixation techniques of free tendon grafts for MPFL-reconstruction are reasonable alternatives as patellar fixation methods.
3

Prospektive randomisierte kontrollierte klinische Studie zur Wirksamkeit eines Eigentrainings mit der Digitalen Gesundheitsanwendung „Mawendo“ bei der Behandlung von Krankheiten der Patella (ICD-10-GM M22): Evaluation der DiGA MAWENDO

Mayer, T., Koska, D., Harsch, A.-K., Maiwald, Christian 06 August 2024 (has links)
In der vorliegenden randomisierten kontrollierten Studie wurde die Wirksamkeit der digitalen Gesundheitsanwendung (DiGA) Mawendo bei der Behandlung von Krankheiten der Patella untersucht und mit der Standardtherapie Physiotherapie der gesetzlichen Krankenversicherung (GKV-Physiotherapie) verglichen. In die Studie eingeschlossen wurden 259 Patienten mit einer ärztlich diagnostizierten Erkrankung der Patella gemäß ICD-10 Klassifikation M22. Nach randomisierter Zuteilung auf die Behandlungsarme absolvierten die Patienten über den 12-wöchigen Behandlungszeitraum entweder ein Eigentraining mit der DiGA Mawendo (Interventionsgruppe IG, 136 Patienten) oder wurden in einer physiotherapeutischen Einrichtung behandelt (Kontrollgruppe KG, 123 Patienten). Für den Nachweis des medizinischen Nutzens (mN) wurden zwei primäre Endpunkte untersucht: - Endpunkt 1: Verbesserung des Funktionszustandes (mNFunktion) - Endpunkt 2: Verbesserung der Morbidität durch Schmerzreduktion (mNSchmerz) Beide Endpunkte wurden mittels eines elektronischen Fragebogens erhoben. Der Endpunkt mNFunktion wurde mithilfe der deutschen Version des Patient Reported Outcome (PRO) KOOS (Knee Injury and Osteoarthritis Outcome Score) erfasst. Die Skala „Activities of Daily Living“ (KOOSADL) quantifizierte hier den mNFunktion (Wertebereich 0-100 Punkte (P), 100 P = bestmöglicher Funktionszustand). Der Endpunkt mNSchmerz wurde durch einen gesondert abgefragten Schmerzscore auf Basis einer Visuellen Analogskala (VAS, Wertebereich 0-100 Punkte, 100 P = stärkste vorstellbare Schmerzen) erhoben. Die Erhebungszeitpunkte wurden wie folgt definiert: Pre (t0): Vor Beginn der ersten Trainingseinheit mit der DiGA Mawendo bzw. vor dem ersten Behandlungstermin einer GKV-Physiotherapie. Post (t12): Nach der Behandlungsdauer von 12 Wochen. Als Nachweis des mN wurde die Überlegenheit (statistisch signifikant und klinisch relevant) der DiGA gegenüber der GKV-Physiotherapie in einem der beiden Endpunkte definiert. Mit der vorliegenden Studie konnte in beiden Endpunkten eine statistisch signifikante und klinisch relevante Überlegenheit der DiGA Mawendo gegenüber der Standardtherapie gezeigt werden. Im Endpunkt mNFunktion erzielte die IG eine mittlere Verbesserung von 15,7 P (95 % KI [13,7 P; 17,6 P]) gegenüber einer Verbesserung von 3,4 P (95 % KI [1,3 P; 5,5 P]) in der KG (Unterschied zwischen IG und KG statistisch signifikant mit p < 0,00001). Im zweiten Endpunkt mNSchmerz reduzierte sich der VAS-Schmerzscore in der IG im Mittel um -22,5 P (95 % KI [-25,2 P; -19,9 P]) gegenüber -6,3 Punkten (95 % KI [-8,7 P; -4,0 P]) in der KG (Unterschied zwischen IG und KG statistisch signifikant mit p < 0,00001). Darüber hinaus wurden in beiden Endpunkten die vorher festgelegten minimalen klinisch relevanten Differenzen (KOOSADL = 10 P, VAS = 10 P) deutlich übertroffen und sogar Verbesserungen im Bereich von „substantial clinical benefits“ erreicht. Medizinischer Nutzen und positiver Versorgunseffekt (pVe) der DiGA Mawendo sind somit evident. Neben dem mN zeigte sich bei Anwendung der DiGA Mawendo in dieser Studie ein weiterer positiver Aspekt. Die klinisch relevante Reduktion des Schmerzes in der IG äußerte sich in einem erheblich verringerten Anteil von Patienten, die zum Zeitpunkt der Post-Befragung Schmerzmittel einnahmen (IG: 28,0 % Pre -> 3,0 % Post vs. KG: 31,4 % Pre -> 29,8 % Post). Dadurch kann mit weniger Nebenwirkungen gerechnet und das Risiko für potenzielle Folgeschäden und -kosten verringert werden.

Page generated in 0.0626 seconds