• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 5
  • 4
  • 2
  • 1
  • Tagged with
  • 21
  • 6
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Stochastische Teilchensysteme zur Approximation der Koagulationsgleichung

Eibeck, Andreas. January 2001 (has links) (PDF)
Berlin, Humboldt-Univ., Diss., 2002. / Computerdatei im Fernzugriff.
2

Stochastische Teilchensysteme zur Approximation der Koagulationsgleichung

Eibeck, Andreas. January 2001 (has links) (PDF)
Berlin, Humboldt-Univ., Diss., 2002. / Computerdatei im Fernzugriff.
3

Stochastische Teilchensysteme zur Approximation der Koagulationsgleichung

Eibeck, Andreas. January 2001 (has links) (PDF)
Berlin, Humboldt-Universiẗat, Diss., 2002.
4

Prokoagulante Aktivität des Monozyten : Fcgamma-Rezeptoren als Trigger und Variable

Fröbe, Martin Leonhard January 2008 (has links)
Regensburg, Univ., Diss., 2009.
5

Neue niedermolekulare Inhibitoren der Tubulinpolymerisation : Synthese und In-vitro-Prüfung von 9-Benzyliden-naphtho[2,3-b]thiophen-4(9H)-onen /

Zuse, Anne. January 2005 (has links)
Univ., Diss.--Münster (Westfalen), 2005. / Zusfassung in dt. Sprache.
6

Stabilität und Koagulation natürlicher und künstlicher kolloidaler Suspensionen

Kuck-Meens, Christa. Unknown Date (has links) (PDF)
Techn. Hochsch., Diss., 2001--Aachen.
7

Modellierung und Modellentwicklung der Rußbildung bei hohem Druck in vorgemischten Verbrennungssystemen

Hu, Dehuan. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2002--Stuttgart.
8

Multidiffusive Konvektion mit Koagulation und Breakup numerische Untersuchungen zur Erweiterung der thermo-diffusiv-sedimentären Konvektion auf veränderliche Partikelgrößen /

Pullmann, Michael. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2003--Bonn.
9

Effekt av ändrade centrifugeringsparametrar på rutinkemi- och koagulationsanalyser / The effect of altered centrifugation parameters on routine chemistry and coagulation assays

Turan, Muhammed January 2022 (has links)
To separate plasma/serum from blood cells, blood samples are centrifuged. Currently, there is no standard centrifugation protocol available. However, there are several centrifugation recommendations from the tube manufacturers. The aim of this study is to evaluate centrifugation program with a shorter centrifugation time and higher centrifugal force and how it affects measured analyte concentrations. 120 sample pairs were collected in lithium-heparin tubes and sodium citrate tubes from 120 participants. One sample of each pair was then centrifuged with reference program (2000g, 10min) for routine chemistry samples and (2500g, 15min) for coagulation samples. The other sample of each pair was centrifuged with programs (3000g, 7min). The statistical analysis was performed using the Student’s t-test and the Holm-Bonferroni method. P-value less than 0.05 was considered statistically significant.There was no significant difference between data from BD tubes and Greiner tubes, therefore the corresponding data from both groups were merged. No statistically significant difference was observed for the following parameters; Cobalamin (B12), High-density lipoprotein (HDL), Lactate dehydrogenase (LD), Phosphate, Triglycerides (TG), Thyroid stimulating hormone (TSH), Activated partial thromboplastin time (APTT), Fibrinogen (Fib) and Prothrombin complex PK (INRR). However, the statistical analysis showed a significant difference regarding potassium (K). Centrifugation program (3000g, 7min) can replace the programs (2000g, 10min) and (2500g, 15min) which are recommended by the tube manufacturers BD & Greiner, with the exception of Potassium which requires more research. A trace of increasing hemolysis, still within acceptable limits, was detected in samples centrifuged with programs (3000g, 7min). The centrifugation programs with a shorter time or less acceleration is preferred. / Blodprover centrifugeras för att separera plasma/serum från blodceller. Inget standardprotokoll för centrifugering är tillgänglig dock finns flertal centrifugeringsrekommendationer från rörtillverkarna. Syftet med denna studie är att utvärdera centrifugeringsprogram med en kortare centrifugeringstid och högre g-tal, samt hur det påverkar uppmätta analytkoncentrationer. 120 provpar samlades i litium-heparin-rör respektive natrium-citrat-rör från 120 deltagare. Det ena provet av varje provpar centrifugerades med referensprogram (2000g, 10 min) för rutinkemi respektive (2500g, 15min) för koagulation medan det andra centrifugerades med program (3000g, 7min). Statistiska analysen utfördes med hjälp av Student t-test och Holm-Bonferroni metoden. P-värde mindre än 0,05 ansåg vara statistiskt signifikant. Ingen betydande skillnad fanns mellan data från BD-rör och Greiner-rör, därför har motsvarande data från både gruppen slagits ihop. Ingen statistiskt signifikant skillnad observerades för följande undersökta parametrar; Kobalamin (B12), High-density lipoprotein (HDL), Laktatdehydrogenas (LD), Fosfat, Triglycerider (TG), Tyroideastimulerande hormon (TSH), Aktiverad partiell tromboplastintid (APTT), Fibrinogin (Fib) och Protrombinkomplex PK(INR). Däremot visade den statistiska analysen en signifikant skillnad avseende kalium (K). Centrifugeringsprogram (3000g, 7min) kan ersätta programmen (2000g, 10min) och (2500g, 15min) som rekommenderas av rörtillverkarna BD & Greiner, med undantag av Kalium som kräver mer undersökning. Ett spår av ökande hemolys, dock fortfarande inom acceptabla gränser, upptäcktes i prover centrifugerades med program (3000g, 7min). Därpå är centrifugeringsprogram med kortare tid eller mindre hastighet att föredra.
10

Stochastic modeling of Brownian and turbulent coagulation

Teichmann, Jakob 24 November 2017 (has links) (PDF)
Als Beitrag zu einer verbesserten Filtration von Metallschmelzen werden stochastische Modelle für den essentiellen Mechanismus der Koagulation von Brownschen Partikeln und Partikeln in turbulenten Strömungen entwickelt und untersucht. Formeln für die zeitliche Entwicklung der Partikelkonzentration in diesen Systemen erlauben die Bestimmung von physikalischen Parametern, welche die Koagulation und somit die Filtration begünstigen. Um wichtige Resultate im Zusammenhang mit der traditionellen Herangehensweise für Brownsche Partikel zu berichtigen und zu erweitern, wird ein neuer Ansatz in Form zweier Modelle entwickelt. Für beide werden Formeln für die Partikelkonzentration, auf Basis einer neuartigen Verallgemeinerung der Matérn Hard-Core-Punktprozesse, abgeleitet. Um im Hinblick auf die Koagulationsgleichung der fraktalartigen Gestalt der Agglomerate besser Rechnung zu tragen, wird deren Morphologie anhand zweier neuer Modelle quantifiziert. Die Arbeit wird durch Anwendung der Modelle und numerische Simulationen von Koagulation und Abscheidung in turbulenten Strömungen abgerundet.

Page generated in 0.0621 seconds