• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 6
  • 6
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An investigation into the validation of pedometers to detect foreleg steps in horses (Equus caballus) at walk and trot

Francis, Elizabeth Jane January 2018 (has links)
Background: Current research, surrounding motor laterality at a population level in horses, indicates that in order to stand with the left forelimb in advance of the other, it is achieved by taking a greater amount of steps with the left foreleg than the right foreleg (McGreevy & Thomson 2006; McGreevy et al. 2007); suggesting that pedometers could effectively estimate asymmetry of forelimb locomotion in grazing horses. This novel method of detecting forelimb preference also reduces the likelihood of operator influence and provides an inexpensive objective measure of vertical movement which has the advantage of scoring large sample sizes, avoids single-day anomalies by recording over multiple days and overcomes logistical challenges (Vincent & Sidman 2003; Chan et al. 2005; Silva et al. 2010; Warren-Smith & McGreevy 2010). However in order to determine the reliability and validity of this novel measure the relationship between pedometer data and those derived from direct observation will first need to be assessed (Warren-Smith and McGreevy 2010). Objectives: To determine: (1) if pedometers accurately record equine steps at walk and trot, when compared to video analysis, (2) if alternative positioning of these pedometers affected the accuracy of step detection when compared to video analysis. Method: Five horses each wearing a Yamax Digiwalk SW-200 (spring lever arm pedometer) and a Yamax Power Walker PW-610/611 (piezoelectric pedometer) positioned on the left foreleg (LF), left scapular (LS), chest (C), right scapular (RS) and right foreleg (RF) walked and trotted on a 20m circle 10 times on each rein to yield 100 results for each gait. Video recorded by GoPro Hero 3 Black edition camera positioned on the girth facing the forefeet using the following settings: 180 degree field of view, 720p, 120fps. Both visual and audio data were captured and recorded. Results: Kruskal-Wallis Test on the deviation from actual number of steps per unit for each type of pedometer and the position of the pedometer compared to the actual number of steps taken by both forelegs determined that there is a significant difference (H1= 340.31; P < 0.0001) between readings in walk and also in trot (H1 = 483.49; P < 0.0001). A further Kruskal-Wallis Test on the deviation from actual number of steps per unit for each type of pedometer and the position of the pedometer compared to the actual number of steps taken by individual forelegs determined that there is a significant difference (H = 403.36; p < 0.0001) at walk and also at trot (H = 477.10; p < 0.0001). Conclusion: In summary, the analysis of the pedometer data compared to video analysis indicate that pedometers are not useful for scoring forelimb movements in horses at walk and trot, regardless of positioning.
2

Koncept på ett hydrauliskt mothåll / Concept of a hydraulic counter hold

Sharef, Hajan, Potari, Marek January 2016 (has links)
New technology in the automotive industry is the key to success. Therefore, it is appreciated when people come with new design ways to solve problems. This leads to innovation in the automotive industry that will lead to better and more environmentally friendly cars. This report presents a concept on a pushing counter lever spring which provides the same characteristics of force curve as a diaphragm spring in a pressure plate of a car has. The mechanism is to be used for long-term testing and evaluating clutch pedals. The work describes the development process and the manufacture of a prototype. The program Creo (CAD / 3D) is largely used to construct the components. As are the subprograms Mechanism Design and Simulate to simulate the movement and loads. Excel is a great help at the theoretical calculation of the mechanism and to evaluate the theory behind the concept. The result shows how to simulate a diaphragm spring in the pressure plate in a car for long-term testing of clutch pedals. The goal is to accurately mimic the force curve of a diaphragm spring, in order to design better pedals, and thus reduce the weight on the pedals to in turn reduce fuel consumption to protect the environment is one of the most important factors of all in the automotive industry.
3

Analýza vlivu kalibrace a vyrovnání pásů na geometrickou přesnost bodového mračna pořízeného UAV lidarovým snímáním / Analysis of the influence of the calibration and strip adjustment on the geometric accuracy of UAV LIDAR point clouds

Dvořák, Dennis January 2021 (has links)
This diploma thesis solves the analysis of the influence of calibration and the method of strips alignment on the geometric accuracy of a point cloud acquired by UAV lidar scanning. The aim was to find out the influence of individual used methods, respectively various combinations. The effect of the design of the cross-flights has also been added. The evaluation was performed using standard deviations of the distances corresponding to the areas scanned in different point bands. Furthermore, verification was performed by comparing checkpoints. The results show that there is no dependence between the individual combinations. The only case was a larger displacement of the point cloud at the edge of the scanned strip in the case of cross-flights.
4

Comparison of Retention and Stability of Implant-Retained Overdentures Based Upon Implant Location, Number, and Distribution

Scherer, Michael David 20 June 2012 (has links)
No description available.
5

Improving the surface finish of the rubber weight plate : Master thesis in mechanical engineering

Augustine, Joyal, Simons, Steven January 2021 (has links)
Flash is the unwanted or excessrubber material that presents on the outersurface of themolded rubber product. This will affect the surface finish; it is a cosmetic defect andit can be removed. It forms because of the leak or the excess molded rubber materialbetween the surface of the mold, typically on the parting line, (Jordan Anderson,2014). The presence of flash will reduce customer satisfaction. There are manymethods to remove the flash. The method is selected according to the degree of flashextension and the location where it occurs.The project aims to design a semi/full automated machine, which helps for having asmooth and fine surface finish of the weight plates. These plates are made up of rubberfor the ELEIKO group. The weight plates have different weights from 10 to 20 kg,but the diameter of each plate stays the same, but the thickness will be different foreach plate. The machine should be designed that removes all the excess rubber andshould smoothen the outer surface of the weight. The purpose of this work is to gainknowledge about different product development methods, respective tools, andtechniques that are used. The machine should be user- friendly, should not becomplicated, should not damage the workpiece (marks or trace of the blade), shouldnot put the employer in danger, and economically feasible.This report presents the progress of designing of the product, product development,methods, and literature study. The designed model can construct in the industry fortheir problem they are faced by the flash. The model is very simple and unique so thateveryone can perform the task without any previous experience. Material alternativeswere evaluated as well as manufacturing possibilities. The designed machine was theoffered for free as means for further research and development. Keywords: flashing, additive manufacturing, Ullman method, Pugh matrix, rubberweight plates, lever arm, smoothening tool.
6

Magnetic Actuation of Biological Systems

Lauback, Stephanie Diane 23 October 2017 (has links)
No description available.

Page generated in 0.0663 seconds