• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 66
  • 44
  • 44
  • 17
  • 12
  • 9
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • Tagged with
  • 407
  • 77
  • 42
  • 41
  • 41
  • 40
  • 37
  • 36
  • 36
  • 35
  • 34
  • 32
  • 29
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

The evolution of total lightning and radar reflectivity characteristics of two mesoscale convective systems over Houston, Texas

Hodapp, Charles Lee 15 May 2009 (has links)
Two mesoscale convective systems (MCSs) passed over the Houston Lightning Detection and Ranging (LDAR) network on 31 October 2005 and 21 April 2006. As the MCSs traverse the LDAR network, the systems slowly mature with a weakening convective line and a developing stratiform region and radar bright band. The intensification of stratiform region precipitation, including the bright band, is thought to play an important role in stratiform lightning structure, charge structure, and total lightning production of MCSs. The stratiform areas quadruple in size and the mean reflectivity values increase substantially by ~ 6 dB. As the stratiform region matures, VHF source density plots show a lightning pathway that slopes rearward and downward from the back of the convective line and into the stratiform region. At early times for both MCSs, the pathway extends horizontally rearward 40 to 50 km into the stratiform region at an altitude of 9 to 12 km. Near the end of the analysis time period, the pathway slopes rearward 40 km and downward through the transition zone before extending 40 to 50 km in the stratiform region at an altitude of 4 - 7 km. The sloping pathway likely results from charged ice particles advected from the convective line by storm relative front-to-rear flow while the level pathway extending further into the stratiform region is likely caused by both charge advection and local in-situ charging. As the stratiform region matures, the stratiform flash rates double and lightning heights decrease. The percentage of lightning flashes originating in the stratiform region increases significantly from 10 - 20% to 50 - 60%. Overall, the number of positive cloud-to-ground flashes in the stratiform region also increases. Between both MCSs, 60% of the positive CGs originated in the convective or transition regions. Both in-situ charging mechanisms created by the development of the mesoscale updraft and charge advection by the front-to-rear flow likely contribute to the increased electrification and lightning in the stratiform region.
92

Total lightning observations of severe convection over North Texas

McKinney, Christopher Michael 15 May 2009 (has links)
Five severe convective cells over North Texas from three separate dates were examined to determine what three dimensional, or “total” lightning data can add to the understanding of a convective cell’s intensity, propagation, and severe weather potential. Total lightning data were obtained from Vaisala Inc.’s Dallas/Fort Worth (D/FW) Lightning Detection and Ranging (LDAR) network. Radar data from two Weather Surveillance Radar – 1988 Doppler (WSR-88D) sites were used for position data and information regarding the intensity and kinematic properties of each cell. Total lightning products used by the National Weather Service Forecast Office in Fort Worth, Texas were compared to total lightning flash rate; a quantity that has been shown to be correlated to changes in cell intensity inferred from other sources, such as radar and satellite data. These products, specifically flash extent density (FED) were also compared to CG flash rate and radar derived measures from the WSR-88D sites. The results of this work show that FED and total flash rate are well correlated, with an average Pearson correlation value of 0.73, indicating that previous total flash rate results may also apply to FED. Lightning hooks, holes, and notches in FED displays indicated likely updraft regions, while appendages were observed to develop prior to deviant motion with two supercells. These results, combined with a greater update frequency provided a useful complement to radar data in the warning decision process. FED jumps were observed prior to several severe weather reports, indicating that total lightning activity may be related to updraft strength as found in past studies. However, FED jumps were sometimes observed without any associated severe event. More work is clearly needed to define what FED changes are of most importance in the short-term prediction of storm severity. The usefulness of the total lightning data on these dates was dependant upon LDAR network status and distance of the cell from the network center. The results of this study suggest that combining total flash rate trends with visual displays of FED provides the greatest added benefit to forecasters in maintaining situational awareness during warning operations.
93

An examination of the relationship between cool season tornadoes and cloud-to-ground lightning flashes

Butts, Douglas Allen, Jr. 25 April 2007 (has links)
The southeast United States is prone to severe weather throughout the year. Despite technological advances, some severe weather events occasionally remain unwarned in this part of the country. Past studies examined the relationship between cloud-to-ground (CG) lightning and warm season severe weather episodes. The present study examined the relationship between cool season tornadoes and CG lightning, with a focus over the southeastern United States, where most cool season tornadoes occur. Data from the Storm Prediction Center and National Lightning Detection Network (NLDN) were used to investigate CG lightning properties within 50 km and one hour before tornado touchdown. This was completed over a period of 13 cool seasons from October 1989 through March 2002. Of 3325 tornado events, 2358 contained at least one NLDN-detectable flash. CG lightning attributes of peak current, multiplicity, and flash density compared well with those of prior warm season lightning research. Overall event frequency appeared to be lower than in the warm season. Almost all Central Plains events were accompanied by at least one NLDN-detectable flash. Up to 70% of tornado events near the Gulf of Mexico and Atlantic coasts contained no NLDN-detectable lightning. Although it is not known why this trend was observed, it is speculated that NLDN detection efficiency and/or storm structure differences may play a role in these observations. Warm season studies have correlated tornadoes with predominantly positive (>50% positive CG lightning), or PPCG storms. Gridded maps showed the greatest percentage and highest frequency of cool season PPCG storms across Kansas and Nebraska, with up to 70% of events associated with PPCG lightning. A secondary, albeit lower, frequency maximum extended 1° to 2° inland across Louisiana into North Carolina. This study also subjectively defined a storm with “enhanced” positive cloud-to-ground (EPCG) lightning as one containing >25% positive cloud-to-ground lightning, which corresponds to approximately the 75th percentile of all cool season tornadoes. This has lead to speculation that EPCG criterion may be a better indicator of the possibility of severe weather than the traditional PPCG criterion.
94

Thor's hammer deflected : a history of the protection of power systems from lightning, with special reference to Queensland, 1950 to 1995 /

Mercer, Douglas. January 2001 (has links)
Thesis (Ph. D.)--University of Queensland, 2001. / Includes bibliographical references.
95

DISTORTION AND INSTABILITY OF ELECTRICALLY STRESSED WATER DROPS FALLING AT TERMINAL VELOCITY

Richards, Clyde Nathan, 1938- January 1971 (has links)
No description available.
96

The lightning ground flash : an engineering study.

Eriksson, Andrew John. January 1979 (has links)
The thesis is concerned with a study of the electrical engineering parameters of the lightning ground flash - i.e. the statistical distributions of peak current amplitudes, discharge current waveform characteristics, and flash striking distances - in the event of flashes to practical engineering structures. In view of its predominating frequency of occurrence in practical situations, the discharge of primary concern is the downward progressing and negatively charged ground flash. A central feature of this work is the establishment of a lightning research station (incorporating a 60 m instrumented mast) in the Transvaal highveld region of South Africa. The design of this station and the related measurement techniques are fully described. Preliminary results accumulated over a 6-year period of observation are presented, and include recordings obtained during direct strikes to the mast, as well as data from associated measurements of additional thunderstorm and lightning parameters. The latter studies include the use of closed circuit television video recordings, together with electrostatic field mills and lightning flash counters. Analysis of the resultant data serves to provide a comprehensive characterisation of the thunderstorm and lightning climatology in the region - on the basis of electrical activity. With only few exceptions, it is concluded that the characteristics of lightning observed in the. Transvaal region are generally consistent with the trends of data from other regions of the world. A unique aspect of the project is a study of lightning striking distances. An attempt to estimate these distances using bi-directional photography of flashes to the research mast is described, and several preliminary results are also presented - in conjunction with the associated measurements of discharge current amplitude. These results are compared with previously used relationships between striking distance and peak current. / Thesis (Ph.D.)-University of Natal, Durban, 1979.
97

Development of a Fast and Efficient Macromodel for Nonuniform Electromagnetic Field Excitation of Transmission Lines

Mashayekhi, Sina 14 December 2010 (has links)
In this thesis, the problem of overvoltage calculation on multiconductor transmission lines due to nonuniform external electromagnetic field excitations, such as lightning, is investigated by introducing a field-voltage macromodel. The main purpose of this thesis is to find a fast and efficient algorithm to model the effect of the radiated electromagnetic fields on transmission lines. This is done by replacing distributed voltage and current sources along the transmission line which are as a result of external electromagnetic field radiation, by voltage and current sources at the terminals of the transmission line. For this purpose, the knowledge of electromagnetic field at every point on the transmission line is required. A transfer function based pole-residue tracing technique will be introduced in this thesis. By using the proposed algorithm, a closed form solution for the lumped sources at the terminals of transmission line in the frequency domain is obtainable. This approach will enable us to bridge the software working in frequency domain with those working in the time domain. The effect of different parameters on calculated overvoltage such as finite conductivity of the ground and lightning return stroke channel (RSC) specifications are studied. The theoretical background and extent of validity of the proposed algorithm are reviewed in this thesis.
98

Development of a Fast and Efficient Macromodel for Nonuniform Electromagnetic Field Excitation of Transmission Lines

Mashayekhi, Sina 14 December 2010 (has links)
In this thesis, the problem of overvoltage calculation on multiconductor transmission lines due to nonuniform external electromagnetic field excitations, such as lightning, is investigated by introducing a field-voltage macromodel. The main purpose of this thesis is to find a fast and efficient algorithm to model the effect of the radiated electromagnetic fields on transmission lines. This is done by replacing distributed voltage and current sources along the transmission line which are as a result of external electromagnetic field radiation, by voltage and current sources at the terminals of the transmission line. For this purpose, the knowledge of electromagnetic field at every point on the transmission line is required. A transfer function based pole-residue tracing technique will be introduced in this thesis. By using the proposed algorithm, a closed form solution for the lumped sources at the terminals of transmission line in the frequency domain is obtainable. This approach will enable us to bridge the software working in frequency domain with those working in the time domain. The effect of different parameters on calculated overvoltage such as finite conductivity of the ground and lightning return stroke channel (RSC) specifications are studied. The theoretical background and extent of validity of the proposed algorithm are reviewed in this thesis.
99

Interaction of Lightning Flashes with Wireless Communication Networks : Special Attention to Narrow Bipolar Pulses

Ahmad, Mohd Riduan January 2014 (has links)
In this thesis, the features of electric field signatures of narrow bipolar pulses (NBPs) generated by cloud flashes are investigated and their effects on wireless communication systems are studied. A handful amount of NBPs (14.5%) have been observed to occur as part of cloud-to-ground flashes in South Malaysia. Occurrence of NBPs in Sweden has been reported for the first time in this thesis. The electric field waveform characteristics of NBPs as part of cloud-to-ground flashes were similar to isolated NBPs found in Sweden and South Malaysia and also to those isolated NBPs reported by previous studies from various geographical areas. This is a strong indication that their breakdown mechanisms are similar at any latitudes regardless of geographical areas. A comparative study on the occurrence of NBPs and other forms of lightning flashes across various geographical areas ranging from northern regions to the tropics is presented. As the latitude decreased from Uppsala, Sweden (59.8°N) to South Malaysia (1.5°N), the percentage of NBP emissions relative to the total number of lightning flashes increased significantly from 0.13% to 12%. Occurrences of positive NBPs were more common than negative NBPs at all observed latitudes. However, as latitudes decreased, the negative NBP emissions increased significantly from 20% (Sweden) to 45% (South Malaysia). Factors involving mixed-phase region elevations and vertical extents of thundercloud tops are invoked to explain the observed results. These factors are fundamentally latitude dependent. In this thesis, the interaction between microwave radiations emitted by cloud-to-ground and cloud flashes events and bits transmission in wireless communication networks are also presented. To the best of our knowledge, this is the first time such effects are investigated in the literature. Narrow bipolar pulses were found to be the strongest source of interference that interfered with the bits transmission.
100

The morphology of eyewall cloud to ground lightning in two category five hurricanes

Squires, Kirt A January 2006 (has links)
Thesis (M.S.)--University of Hawaii at Manoa, 2006. / Includes bibliographical references (leaves 71-77). / xii, 77 leaves, bound col. ill. 29 cm

Page generated in 0.0836 seconds