• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energy savings with a new aeration and control system in a mid-size Swedish wastewater treatment plant / Energibesparingar genom ett nytt luftnings- och reglersystem i ett medelstortsvenskt avloppsreningsverk

Larsson, Viktor January 2011 (has links)
Within this study it was investigated how much energy and money that could be saved by implementing new aeration equipment and aeration control in Sternö wastewater treatment plant (WWTP). Sternö WWTP is a full-scale plant built in 1997 and dimensioned for 26 000 population equivalents. The plant has two parallel biological treatment lines with pre-denitrification. During the study, one of the treatment lines was used as a test line, where new aeration equipment and control was implemented. The other line was used as a reference line, where the aeration equipment and control was maintained as before. The new aeration equipment that was implemented to support the test line was an AtlasCopco screw blower, fine bubble Sanitaire low pressure diffusers and measurement equipment. Two control strategies were tested: oxygen control and ammonium control. The results show that 35 percentage points of the test line energy consumption was reduced with the new screw blower. The diffusers saved another 21 percentage points and by fine tuning the controllers, the oxygen concentrations and the air pressure a further 9 percentage points could be saved. The ammonium control gave no energy savings, since the lowest allowed DO set-point (0.7 mg L-1) kept effluent ammonium below the ammonium set-point of 1 mg L-1.  The final energy savings of the test line was 65 ± 2 %. Each aeration equipment upgrade increased the energy savings with: •    Blower 35 %. •    Diffusers 32 %. •    Oxygen control with decreased DO concentrations and air pressure 21 %. The final savings correspond to 13 % of the total energy consumption of Sternö WWTP. These savings are equivalent to annual savings of 178 MWh, which decreases the energy costs by 200 000 SEK per year. The payback period of the implemented aeration equipment and control was 3.7 years. / I denna studie har det undersökts hur mycket energi och pengar som kan sparas genom att installera ny luftningsutrusning och luftningsreglering i Sternö avloppsreningsverk. Reningsverket är beläget i Karlshamn och dimensionerat för 26 000 personekvivalenter. Den biologiska reningen är uppdelad på två parallella reningslinjer, där den ena användes till försök och den andra som referenslinje i denna studie. Den biologiska reningen utgörs av en konventionell aktivslamprocess med fördenitrifikation. Studien innefattade en simulering där två olika reglerstrategier för luftningen jämfördes. Simuleringen gjordes i programmet Benchmark Simulation Model no 1 och modellen anpassades för att efterlikna Sternö reningsverk på bästa sätt. De två reglerstrategierna för luftningen utgjordes av luftstyrning baserad på syrekoncentration i bioreaktorerna och luftstyrning baserad på utgående ammoniumkoncentration från bioreaktorerna. Simuleringen visade att energibesparingen från ammoniumreglering jämfört med en syrereglering är liten. Fördelen med ammoniumreglering är istället att den önskade reningsgraden lättare kan uppfyllas över året, trots varierande temperatur. Vid fullskaleförsök vid försökslinjen installerades ny luftningsutrustning (AtlasCopco blåsmaskin med skruvteknologi, Sanitaire småbubbliga diffusorer, samt mätnings-utrustning) och ny luftstyrning. Två luftstyrningsstrategier testades: syrereglering och ammoniumreglering. Resultaten visade att blåsmaskinen gav en energibesparing på 35 procentenheter, att diffusorerna gav en energibesparing på 21 procentenheter och att fininställd syrereglering tillsammans med sänkta syre- och lufttrycksnivåer gav en sänkning på 9 procentenheter. Ammoniumregleringen gav ingen energibesparing eftersom den lägst tillåtna syrekoncentrationen (0,7 mg L-1) höll ammonium-koncentrationen under sitt börvärde på 1 mg L-1. Den slutliga energibesparingen för testlinjen var 65 ± 2 %. Varje luftningsutrustning bidrog med följande energibesparing: •    Blåsmaskin 35 %. •    Diffusorer 32 %. •    Ny syrereglering med sänkta syre- och lufttrycksnivåer 21 %. Den slutliga energibesparingen i testlinjen motsvarar 13 % av Sternö reningsverks totala energiförbrukning, vilket gör att 178 MWh kan sparas per år. Den minskade energi-förbrukningen sänker energikostnaden för reningsverket med 200 000 SEK per år. Återbetalningstiden på den till försökslinjen installerade utrustningen var 3,7 år.
2

Ammoniumåterkoppling på Himmerfjärdsverket – utvärdering genom försök och simuleringar / Ammonium feedback control at Himmerfjärden wastewater treatment plant – evaluation through full-scale experiments and simulations

Andersson, Sofia January 2012 (has links)
Avloppsreningsverk står inför uppgiften att rena inkommande vatten för att möta lagstiftade gränsvärden till en så låg kostnad som möjligt. Att syresätta biologiska reningsprocesser är kostsamt eftersom luftningsanordningen förbrukar mycket energi. Ungefär en femtedel av Himmerfjärdsverkets totala elenergiförbrukning går till luftning av biologiska processer. För att öka Himmerfjärdsverkets energieffektivitet startades under 2010 experiment med olika strategier för luftflödesstyrning. En av verkets nitrifikationsbassänger byggdes då om för att möjliggöra zonvis reglering av syrehalten. Syftet med denna studie var att utvärdera reglering med ammoniumåterkoppling och syrehaltsprofil för styrning av Himmerfjärdsverkets nitrifikationsprocess. Utvärderingen baserades på reningsresultat och energiförbrukning. Med nuvarande reglerstrategi varieras luftningen genom återkoppling från syrehalten i den andra av sex zoner i varje luftad bassäng. Denna reglering medför att det uppstår ett överskott av syre i slutet av bassängerna. Det finns således potential att spara energi om luftningen kan regleras så att syreöverskott undviks. Modellsimuleringar i Benchmark Simulation Model no. 1 (BSM1) användes för att jämföra snabb och långsam ammoniumåterkoppling samt olika typer av syrehaltsprofiler inför försök i full skala. Modellen byggdes om och kalibrerades för att efterlikna Himmerfjärdsverkets process. Strategierna utvärderades för två scenarier; ett utan några övre begränsningar för luftningen och ett där Himmerfjärdsverkets luftflödesbegränsningar simulerades. Resultatet från simuleringarna visade att långsam ammoniumåterkoppling var den mest energieffektiva reglerstrategin i båda scenarierna. Resultatet visade även att det var möjligt att minska syretoppar genom en stigande syrehaltsprofil längs med bassängens flödesriktning. Genom fullskaleförsök utvärderades syrehaltsprofil och ammoniumåterkoppling. Resultatet visade att ammoniumåterkoppling var den reglerstrategi som förbrukade minst luft per mängd avskiljt ammoniumkväve och jämfört med ursprunglig reglering erhölls en 16 % lägre energiförbrukning. / Wastewater treatment plants (WWTP) have the challenging task to treat incoming water in order to meet the discharge limits at the lowest possible cost. Aeration of biological treatment processes is one of the most energy consuming posts at a WWTP. At Himmerfjärden WWTP approximately one fifth of the total electric energy consumption is used for aeration of biological processes. With the purpose of making Himmerfjärden WWTP more energy efficient full-scale experiments with different aeration control strategies started in 2010. In one of the aerated tanks a new control system was installed in order to allow zonewise control of the dissolved oxygen (DO). The objective of this master thesis was to evaluate ammonium feedback control and DO-profile control at Himmerfjärden WWTP. The evaluation was made with regard to effluent quality and aeration needs. With the original control strategy aeration is varied to maintain a constant concentration of dissolved oxygen in the second of six zones in each aerated tank. With this control strategy oxygen peaks occur in the last zones of the aerated tank. Thus, there is potential to save energy if these oxygen peaks can be avoided. Simulations were carried out in the Benchmark Simulation Model no. 1 (BSM1) where fast and slow ammonium feedback control and different DO-profiles were evaluated. The model was modified and calibrated to resemble the process at Himmerfjärden WWTP. The simulations showed that the slow ammonium feedback control was the most energy-efficient strategy. The results also showed that it was possible to reduce oxygen peaks by increasing the oxygen set-point along the aerated tank, e.g. an increasing DO-profile. The full-scale experiments included ammonium feedback control and DO-profile control. The results show that ammonium feedback control needed less airflow per amount ammonium removed, compared to both the DO-profile and the original control strategy, with a 16 % lower energy consumption compared to the original control strategy.
3

Luftflödesstyrning på Käppalaverket – utvärdering av konstanta styrsignaler / Aeration control at the Käppala wastewater treatment plant - evaluation of constant control signals

Nordenborg, Åsa January 2011 (has links)
På Käppalaverket i Stockholm står luftningen av de biologiska bassängerna för omkring en femtedel av verkets totala elenergiförbrukning. I ett försök att minska energikostnaden utvärderades under hösten 2010 nya metoder för luftflödesreglering på verket. Grundtanken var att styra luftflödet efter medelvärdet på utgående ammoniumkoncentration under en längre tid, istället för som idag efter momentana värden. Ett vanligt sätt att styra luftflöden på reningsverk idag är att använda återkoppling från utgående ammoniumkoncentration, vilket syftar till att alltid hålla den utgående koncentrationen vid ett valt börvärde. Lagstiftade gränsvärden på ammonium avser dock normalt medelvärden över en längre tid, såsom kvartal eller år. Istället för att anpassa luftflödet efter den inkommande belastningen är det därför möjligt att hålla luftflödet relativt konstant medan istället den utgående koncentrationen tillåts variera. I denna studie visades en energibesparing kunna erhållas om luftflödets variation reduceras. Två strategier utvärderades i vilka luftflödet respektive syrehalten hölls så konstant som möjligt. Dessa jämfördes med den idag använda styrstrategin på Käppalaverket, i vilken luftflödet anpassas efter den inkommande belastningen genom återkoppling. Studien inkluderade både simuleringar i modellen Benchmark Simulation Model no. 1 och fullskaleförsök på Käppalaverket. I både simuleringar och fullskaleförsök resulterade de två utvärderade strategierna i en lägre luftförbrukning per reningsgrad än den idag använda återkopplingsstrategin. I fullskaleförsöken erhölls en luftflödesreduktion på 11 % då luftflödet hölls konstant och 15 % då syrehalten hölls konstant. Båda strategierna genererade dock en kraftigt varierande utgående ammoniumkoncentration. Variationerna var störst då luftflödet hölls konstant och korrelerade inte med den dygnsbaserade belastningsprofilen. Sammanfattningsvis visade studien att en reducering av luftflödets variation resulterar i en lägre luftförbrukning men också i en ökad instabilitet. En konstant syrehalt gav en större energivinst och även en stabilare ammoniumreduktion än ett konstant luftflöde, varför denna metod har störst potential till vidare implementering i fullskala. / The aeration of the bioreactors is responsible for one fifth of the energy consumption at the Käppala wastewater treatment plant (WWTP) in Stockholm. In this report, new methods for aeration control were evaluated in order to reduce the energy costs at the plant. The main idea was to control the effluent ammonia concentration in terms of mean values instead of momentary values. A quite common approach for aeration control is to use feedback from the effluent ammonia concentration, thus aiming to keep the effluent concentration consistently at a certain set point. However, discharge limits normally refer to mean values over longer periods of time, such as months or years. Instead of adjusting the airflow to the incoming load it is therefore possible the keep the airflow fairly constant while allowing a fluctuating effluent concentration. In this paper, it was shown that by reducing the variation of the airflow, energy could be saved. Two methods were evaluated in which the airflow and oxygen concentration respectively was held constant. These methods were compared to the control strategy used today at the Käppala WWTP, where feedback control adjusts the airflow to the influent load. The study consisted of simulations with the Benchmark simulation model no. 1 (BSM1) as well as full scale experiments at the Käppala WWTP. Both the simulations and full scale experiments showed a reduced aeration per nutrient removal for the evaluated methods. In full scale, the total airflow reduction was 11 % when the airflow was held constant and 15 % when the oxygen concentration was held constant. However, the methods resulted in large variations of the effluent ammonia concentration, which did not correlate to the daily influent load. The variations were especially large when the airflow was held constant. In summary, this study showed that a reduced airflow variation results in lower aeration costs but also less stability. A constant oxygen concentration required less aeration and provided a more stable degree of ammonia removal than a constant airflow. For this reason, aeration control with a constant oxygen concentration has the best potential for further use at the Käppala WWTP.

Page generated in 0.3454 seconds