1 |
Χρήση λυοφιλιωμένων ακινητοποιημένων κυττάρων Lactobacillus casei σε σταφίδες για την παραγωγή ζυμούμενων προιόντων γάλακτοςΓούναρη, Αθανασία 06 July 2015 (has links)
-- / In the present thesis we do use of lyophilized immobilized Lactobacillus casei cells in raisins in order to produce fermented products of milk.
|
2 |
Estratégias do processo para a conservação da potência da vacina rábica de uso veterinário por liofilização / Strategies of the process for the conservation of the potency of rabies vaccine for veterinary use by lyophilizationCaricati, Aline Tojeira Prestia 11 April 2012 (has links)
Uma vacina liofilizada, em comparação a uma líquida, possui inúmeras vantagens, tais como: a melhora na estabilidade do produto às variações de temperatura aumentando sua vida de prateleira, possibilitando uma melhor logística do produto aos locais onde o acesso à rede refrigerada é difícil. O presente trabalho visou investigar as estratégias do processo para a conservação da potência da vacina rábica de uso veterinário por liofilização. O material testado foi a vacina rábica inativada (VRI). Ao total foram testados 13 excipientes com três concentrações diferentes. O processo de triagem utilizado para a escolha das melhores formulações (VRI + excipiente) foi liofilização em microplacas próprias para cultivo celular adaptadas ao liofilizador, sendo posteriormente verificada a preservação da antigenicidade da vacina por meio do teste de ELISA. A análise estatística foi realizada no programa SPSS® v.17, aplicando análise de regressão para dados categóricos. A arginina 0,5%, o PEG 3350 0,5%, a sacarose 2%, a maltose 1% e a trealose 1% foram os que deram melhores resultados, um alto \"score\" de antigenicidade em comparação à vacina liofilizada sem adição de excipientes. A temperatura de colapso da VRI e de suas diversas formulações foi determinada por meio de um microscópio acoplado a um módulo de liofilização. A análise térmica foi realizada em Calorimetria Exploratória Diferencial (Differential Scanning Calorimetry - DSC). Realizou-se os seguintes testes para avaliação da VRI liofilizada em frasco ampola: microscopia eletrônica de varredura (MEV) para análise da estrutura da pastilha e o antibody-binding test (ABT) - Teste de ligação do anticorpo modificado para determinação da potência da VRI e suas formulações. A umidade residual da VRI com PEG3350 0,5% liofilizada foi determinada em temperatura constante de 100ºC resultou em 1,60%. A pastilha da vacina rábica + PEG 3350 0,5% liofilizada em frasco ampola apresentou a elegância farmacêutica esperada de um produto liofilizado. / A lyophilized vaccine, compared to a liquid form, has many advantages, such as the improvement in product stability to changes in temperature by increasing its shelf life, allowing better logistics for product to locations where access to chill is difficult to achieve. This work has investigated the strategies of the process for the conservation of the potency of rabies vaccine for veterinary use by lyophilization. The material tested is an inactivated rabies vaccine (VRI). Altogether 13 excipients were tested with three different concentrations. The screening process used to choose best formulation (s) (VRI + excipient) was lyophilization in microplates suitable for cell culture adapted to the lyophilizer, and subsequently verified the preservation of the antigenicity of the vaccine through the ELISA test. Statistical analysis was performed using SPSS® v.17, applying regression analysis for categorical data. Arginine 0.5%, PEG 3350 0.5%, Sucrose 2%, Maltose 1% and Trehalose 1% were those that gave better results, a high score of antigenicity compared to the lyophilized vaccine with no added excipients. The temperature of collapse of VRI and its various formulations was determined using a microscope coupled to a module of lyophilization. Thermal analysis was performed in Differential Scanning Calorimetry (DSC). The following tests were used for evaluation of freeze-dried VRI: Scanning electron microscopy (SEM), Antibody-binding test (ABT). The residual moisture of lyophilized samples were determined in the moisture analyzer at constant temperature of 100 °C and resulted in 1.60%. The cake of lyophilized rabies vaccine + 0.5% PEG 3350 in vial showed the pharmaceutical elegance expected of a lyophilized product.
|
3 |
Estratégias do processo para a conservação da potência da vacina rábica de uso veterinário por liofilização / Strategies of the process for the conservation of the potency of rabies vaccine for veterinary use by lyophilizationAline Tojeira Prestia Caricati 11 April 2012 (has links)
Uma vacina liofilizada, em comparação a uma líquida, possui inúmeras vantagens, tais como: a melhora na estabilidade do produto às variações de temperatura aumentando sua vida de prateleira, possibilitando uma melhor logística do produto aos locais onde o acesso à rede refrigerada é difícil. O presente trabalho visou investigar as estratégias do processo para a conservação da potência da vacina rábica de uso veterinário por liofilização. O material testado foi a vacina rábica inativada (VRI). Ao total foram testados 13 excipientes com três concentrações diferentes. O processo de triagem utilizado para a escolha das melhores formulações (VRI + excipiente) foi liofilização em microplacas próprias para cultivo celular adaptadas ao liofilizador, sendo posteriormente verificada a preservação da antigenicidade da vacina por meio do teste de ELISA. A análise estatística foi realizada no programa SPSS® v.17, aplicando análise de regressão para dados categóricos. A arginina 0,5%, o PEG 3350 0,5%, a sacarose 2%, a maltose 1% e a trealose 1% foram os que deram melhores resultados, um alto \"score\" de antigenicidade em comparação à vacina liofilizada sem adição de excipientes. A temperatura de colapso da VRI e de suas diversas formulações foi determinada por meio de um microscópio acoplado a um módulo de liofilização. A análise térmica foi realizada em Calorimetria Exploratória Diferencial (Differential Scanning Calorimetry - DSC). Realizou-se os seguintes testes para avaliação da VRI liofilizada em frasco ampola: microscopia eletrônica de varredura (MEV) para análise da estrutura da pastilha e o antibody-binding test (ABT) - Teste de ligação do anticorpo modificado para determinação da potência da VRI e suas formulações. A umidade residual da VRI com PEG3350 0,5% liofilizada foi determinada em temperatura constante de 100ºC resultou em 1,60%. A pastilha da vacina rábica + PEG 3350 0,5% liofilizada em frasco ampola apresentou a elegância farmacêutica esperada de um produto liofilizado. / A lyophilized vaccine, compared to a liquid form, has many advantages, such as the improvement in product stability to changes in temperature by increasing its shelf life, allowing better logistics for product to locations where access to chill is difficult to achieve. This work has investigated the strategies of the process for the conservation of the potency of rabies vaccine for veterinary use by lyophilization. The material tested is an inactivated rabies vaccine (VRI). Altogether 13 excipients were tested with three different concentrations. The screening process used to choose best formulation (s) (VRI + excipient) was lyophilization in microplates suitable for cell culture adapted to the lyophilizer, and subsequently verified the preservation of the antigenicity of the vaccine through the ELISA test. Statistical analysis was performed using SPSS® v.17, applying regression analysis for categorical data. Arginine 0.5%, PEG 3350 0.5%, Sucrose 2%, Maltose 1% and Trehalose 1% were those that gave better results, a high score of antigenicity compared to the lyophilized vaccine with no added excipients. The temperature of collapse of VRI and its various formulations was determined using a microscope coupled to a module of lyophilization. Thermal analysis was performed in Differential Scanning Calorimetry (DSC). The following tests were used for evaluation of freeze-dried VRI: Scanning electron microscopy (SEM), Antibody-binding test (ABT). The residual moisture of lyophilized samples were determined in the moisture analyzer at constant temperature of 100 °C and resulted in 1.60%. The cake of lyophilized rabies vaccine + 0.5% PEG 3350 in vial showed the pharmaceutical elegance expected of a lyophilized product.
|
4 |
Valoración histológica de la respuesta pulpar y hepática del formocresol y el hueso liofilizado en dientes de rata.Alcaina Lorente, Mª Antonia 25 January 2003 (has links)
Son varios los agentes que se han utilizado para las pulpotomías en dientes primarios, siendo el formocresol el más difundido.
El objetivo de este estudio fue evaluar la respuesta pulpar en dientes de rata cuando el hueso liofilizado es usado como agente de pulpotomía y analizar los cambios histológicos del tejido hepático.
La muestra de este estudio estaba formada por 60 ratas de raza Sprague-Dawley. El tratamiento se realizó en los primeros molares superiores, siendo un total de 120 dientes tratados. Se establecieron seis grupos, según el agente utilizado y el tiempo de evolución de la muestra ( 30 días, 45 días y 60 días).
Con la utilización del hueso liofilizado se obtuvo una mejor respuesta del tejido pulpar con menor grado de inflamación. No se hallaron evidencias histológicas de patología hepática con indicio de necrosis o degeneración en ninguna de las muestras de hígado estudiadas.
|
5 |
Biodegradação de cianeto em efluente siderúrgico utilizando lodo da estação de tratamento biológico e lodo liofilizado, em escala laboratorial e planta piloto / Biodegradation assessment of cyanide in steel plant wastewater using its own sludge from the treatment plant on the laboratory scale and pilot plantSouza, Cláudio Márcio do Amaral 02 September 2014 (has links)
A indústria siderúrgica gera seus efluentes com altas concentrações de cianeto. O cianeto é uma substância altamente tóxica que deve ser degradada para ser eliminada do efluente, obedecendo a legislação vigente,Resolução CONAMA nº 430 de 13 de maio de 2011, que fixa os padrões para descarte de efluentes nos corpos receptores.O processo convencional de tratamento físico-químico usado para esta tipologia de efluente é a conversão de cianeto em complexo metálico. Entretanto, este processo é normalmente dispendioso e requer tratamento posterior dos subprodutos gerados, bem como da lama gerada contendo o complexo metálico de cianeto.Uma alternativa ao tratamento físico-químico é o uso da biodegradação por alguns gêneros de bactérias, incluindo Pseudomonas. A biodegradação de efluente siderúrgico contendo cianeto pelo processo de lodo ativado, utilizando microrganismos do tratamento biológico existente, torna-se uma alternativa para substituição parcial do tratamento físico-químico convencional. Logo, este trabalho teve por objetivo principal, avaliar a biodegradação de cianeto em um efluente siderúrgico, utilizando lodo ativado da estação de tratamento biológico e lodo liofilizado comercial. Foram realizados ensaios em escala laboratorial e em planta piloto. Em escala laboratorial, a redução da concentração de cianeto utilizando lodo da estação de tratamento biológico foi de 66% e com o lodo liofilizado comercial, a redução foi de 71%. Os resultados de degradação de cianeto na planta piloto, utilizando o lodo da estação de tratamento biológico e o lodo liofilizado, foram redução de 33% e 69%, respectivamente. Os resultados obtidos demonstraram que houve biodegradação de cianeto tanto em escala laboratorial quanto em planta piloto. A biodegradação de cianeto no efluente siderúrgico com concentrações reduzidas de amônia e fenol, sugere que os microrganismos utilizaram o cianeto como fonte de carbono e nitrogênio, aumentando dessa forma, a taxa de degradação. / The steel industry generates its effluents with high concentrations of cyanide. Cyanide is a highly toxic substance that must be degraded to be eliminated from the effluent complying with current legislation, CONAMA Resolution No. 430 of 13 May 2011 laying down the standards for discharge of effluents into bodies receptores. The conventional physicochemical treatment process used for this type of effluent is the conversion of cyanide into metal complex. However, this process is costly and usually requires further treatment of the byproducts generated, as well the generated sludge containing the metal complex of Cyanide. An alternative to physico-chemical treatment is the use of biodegradation for a few genres of bacteria including Pseudomonas. The biodegradation of steel plant effluent containing cyanide by the activated sludge process, using microorganisms of the existing biological treatment, becomes an alternative to partial replacement of conventional physico-chemical treatment. Therefore, this study was aimed to evaluate the biodegradation of cyanide in a steel plant wastewater using activated sludge from biological treatment station and sludge lyophilized commercial. Tests on laboratory scale and pilot plant were performed. In laboratory scale, the concentration reducing of cyanide using sludge from biological treatment plant was 66% and the commercial lyophilized sludge the reduction was 71%. The results of degradation of cyanide in the pilot plant using biological treatment of mud and sludge lyophilized station were reduced by 33% and 69%, respectively. The results showed that there was biodegradation of cyanide in laboratory scale and pilot plant. The biodegradation of the steel plant cyanide effluent with reduced concentrations of ammonia and phenol, suggests that the microorganisms used the cyanide as source of carbon and nitrogen, thus increasing the rate of degradation.
|
6 |
Biodegradação de cianeto em efluente siderúrgico utilizando lodo da estação de tratamento biológico e lodo liofilizado, em escala laboratorial e planta piloto / Biodegradation assessment of cyanide in steel plant wastewater using its own sludge from the treatment plant on the laboratory scale and pilot plantCláudio Márcio do Amaral Souza 02 September 2014 (has links)
A indústria siderúrgica gera seus efluentes com altas concentrações de cianeto. O cianeto é uma substância altamente tóxica que deve ser degradada para ser eliminada do efluente, obedecendo a legislação vigente,Resolução CONAMA nº 430 de 13 de maio de 2011, que fixa os padrões para descarte de efluentes nos corpos receptores.O processo convencional de tratamento físico-químico usado para esta tipologia de efluente é a conversão de cianeto em complexo metálico. Entretanto, este processo é normalmente dispendioso e requer tratamento posterior dos subprodutos gerados, bem como da lama gerada contendo o complexo metálico de cianeto.Uma alternativa ao tratamento físico-químico é o uso da biodegradação por alguns gêneros de bactérias, incluindo Pseudomonas. A biodegradação de efluente siderúrgico contendo cianeto pelo processo de lodo ativado, utilizando microrganismos do tratamento biológico existente, torna-se uma alternativa para substituição parcial do tratamento físico-químico convencional. Logo, este trabalho teve por objetivo principal, avaliar a biodegradação de cianeto em um efluente siderúrgico, utilizando lodo ativado da estação de tratamento biológico e lodo liofilizado comercial. Foram realizados ensaios em escala laboratorial e em planta piloto. Em escala laboratorial, a redução da concentração de cianeto utilizando lodo da estação de tratamento biológico foi de 66% e com o lodo liofilizado comercial, a redução foi de 71%. Os resultados de degradação de cianeto na planta piloto, utilizando o lodo da estação de tratamento biológico e o lodo liofilizado, foram redução de 33% e 69%, respectivamente. Os resultados obtidos demonstraram que houve biodegradação de cianeto tanto em escala laboratorial quanto em planta piloto. A biodegradação de cianeto no efluente siderúrgico com concentrações reduzidas de amônia e fenol, sugere que os microrganismos utilizaram o cianeto como fonte de carbono e nitrogênio, aumentando dessa forma, a taxa de degradação. / The steel industry generates its effluents with high concentrations of cyanide. Cyanide is a highly toxic substance that must be degraded to be eliminated from the effluent complying with current legislation, CONAMA Resolution No. 430 of 13 May 2011 laying down the standards for discharge of effluents into bodies receptores. The conventional physicochemical treatment process used for this type of effluent is the conversion of cyanide into metal complex. However, this process is costly and usually requires further treatment of the byproducts generated, as well the generated sludge containing the metal complex of Cyanide. An alternative to physico-chemical treatment is the use of biodegradation for a few genres of bacteria including Pseudomonas. The biodegradation of steel plant effluent containing cyanide by the activated sludge process, using microorganisms of the existing biological treatment, becomes an alternative to partial replacement of conventional physico-chemical treatment. Therefore, this study was aimed to evaluate the biodegradation of cyanide in a steel plant wastewater using activated sludge from biological treatment station and sludge lyophilized commercial. Tests on laboratory scale and pilot plant were performed. In laboratory scale, the concentration reducing of cyanide using sludge from biological treatment plant was 66% and the commercial lyophilized sludge the reduction was 71%. The results of degradation of cyanide in the pilot plant using biological treatment of mud and sludge lyophilized station were reduced by 33% and 69%, respectively. The results showed that there was biodegradation of cyanide in laboratory scale and pilot plant. The biodegradation of the steel plant cyanide effluent with reduced concentrations of ammonia and phenol, suggests that the microorganisms used the cyanide as source of carbon and nitrogen, thus increasing the rate of degradation.
|
7 |
Avaliação da aplicação de um campo magnético permanente sepultado em área de enxerto ósseo alógeno e dento-alveolar : estudo experimental em ratosAzambuja, Henrique Voltolini de January 2007 (has links)
Proposição: O presente trabalho propõe o estudo histológico descritivo da aplicação de um campo magnético sepultado, estático e permanente em área de enxerto ósseo alógeno liofilizado e dento-alveolar associada a defeito cirúrgico em mandíbulas de ratos. Metodologia: estudo experimental in vivo, randomizado. Amostra foi composta por 21 ratos, da espécie Rattus novergicus albinus, linhagem Wistar, machos, divididos em três grupos, correspondendo aos tempos experimentais de sete, 21 e 45 dias. Foram realizadas ostectomias associadas a odontossecções, na face lateral externa do corpo mandibular e no ramo ascendente, atingindo transversalmente a raiz do incisivo inferior e os ápices dos molares. Este defeito cirúrgico permitiu a adaptação de dispositivos metálicos magnetizados (grupo teste) e não magnetizados (grupo controle) associados às regiões apicais dos molares e ao coto distal do incisivo inferior, local este onde realizou-se enxertia óssea alógena liofilizada. A intensidade média do campo magnético sepultado e permanente foi de 250 gauss.Resultados: observou-se no grupo teste e controle, nos diferentes tempos experimentais a gradativa integração do enxerto ósseo alógeno liofilizado, a manutenção da vitalidade pulpar dos molares e coto proximal do incisivo inferior, além da contínua erupção do incisivo inferior do rato. Nos grupos teste, principalmente aos 45 dias, constatou-se uma diferenciada e exuberante neoformação óssea centrípeta em direção aos dispositivos metálicos imantados. Conclusão: o campo magnético sepultado in vivo foi capaz de favorecer o processo de cicatrização óssea no defeito cirúrgico criado. / Purpose: The present study provides a descriptive histological analysis of the use of a buried, static and permanent magnetic field in lyophilized bone allografts in a dentoalveolar area associated with surgical defects in rat mandibles. Method: a randomized in vivo experimental study was carried out with 21 male Wistar rats (Rattus norvegicus albinus), which were split into three groups, corresponding to 7, 21 and 45 experimental days. Ostectomies associated with odontotomies were performed on the outer lateral face of the mandibular body and in the ascending branch, cross-sectionally to the root of the lower incisor and to the molar apices. This surgical defect allowed for the use of magnetized (test group) and non-magnetized (control group) metal devices associated with molar apices and with the distal stump of the lower incisor, where the lyophilized bone allograft was performed. The intensity of the buried and permanent magnetic field amounted to 250 gauss. Results: In the test and control groups, there was gradual integration of the lyophilized bone allograft, maintenance of pulp vitality of the molars and of the proximal stump of the lower incisor, in addition to continuous eruption of the lower incisor. In the test groups, especially at 45 days, there was distinct and pronounced centripetal new bone formation in a direction toward the magnetized metal devices. Conclusion: the in vivo buried magnetic field favored bone healing at the site of the surgical defect.
|
8 |
Comparação de enxerto ósseo cortical autógeno e implante ósseo cortical alógeno liofilizado, congelado a -70ºC ou conservado no mel na substituição de segmento diafisário do fêmur de gatos domésticos.Ferreira, Márcio Poletto January 2008 (has links)
Os felinos domésticos há muito tempo são utilizados como animais de companhia, tornando freqüentes os atendimentos veterinários a esta espécie. As afecções ortopédicas em gatos ocupam papel de destaque na rotina do traumatologista veterinário, que pode deparar-se com fraturas cominutivas de ossos longos, neoplasias ósseas, não-uniões ou uniões-viciosas de fraturas. Uma das opções para o tratamento dessas afecções é a utilização de enxerto ou implante ósseo. O objetivo deste trabalho foi avaliar implantes ósseos corticais alógenos conservados em mel, congelados a -70°C ou liofilizados na substituição de segmento diafisário do fêmur de felinos domésticos. Foi confeccionada uma falha óssea de três centímetros na região diáfisária do fêmur de 24 felinos adultos. Em seis felinos (grupo controle), a falha foi preenchida com o próprio osso removido após a retirada do periósteo, endósteo e medula óssea, e em outros 18 animais, foi preenchida com implantes ósseos corticais alógenos conservados em mel (seis animais), congelado (seis animais) e liofilizado (seis animais). Os animais foram avaliados clínica, radiográfica e histologicamente até completarem 180 dias de pós-operatório. A porcentagem de incorporação foi de 91,6% no grupo controle, com tempo médio necessário para consolidação de 83,1 dias; no grupo mel foi de 75%, com tempo médio de 105 dias; no grupo congelado foi de 83,3% com tempo médio de 78 dias e no grupo liofilizado foi de 25%, com tempo médio de 120 dias. Foi encontrada diferença estatisticamente significativa entre as porcentagens de consolidação do grupo liofilizado em relação aos grupos congelado e controle. Não houve diferença estatística entre os grupos com relação ao tempo de consolidação. Foi identificada a bactéria Brevibacterium spp. em um dos implantes conservados no mel. Foi possível concluir que os implantes ósseos autógenos e os conservados no mel e a -70°C foram eficazes no preenchimento de defeito cortical em fêmur de felinos adultos, enquanto que os implantes liofilizados necessitam de maior avaliação da resistência e imunogenicidade para tornarem-se uma opção viável em felinos. / Cats with orthopedic conditions are a prominent part of the clinical work of veterinary traumatologists. Conditions such as comminuted fractures of the long bones, bone cancers and non-unions or unions that repeatedly fracture are often difficult to repair surgically and may require the use of bone grafts or implants for successful treatment. This study evaluated cortical bone allografts preserved in honey, frozen at -70°C or lyophilized for correcting 3 cm long bone defects created in the diaphysis of the right femur of adult domestic cats (n=24). In the control group (n=6), the defect was repaired using the autologous bone following removal of the periosteum, endosteum and bone marrow. In the remaining animals (n=6/group), the defect was repaired with cortical bone allografts preserved in honey, frozen or lyophilized. Success of implant incorporation and length of time for consolidation were assessed through clinical, radiographic and histological evaluations performed up to 180 days after surgery. In the control, frozen, honey and lyophylized groups, respectively, success of implant incorporation was 91.6%, 83.3%, 75%, and 25%, with corresponding mean length of time for consolidation of 83.1, 78, 105 and 120 days. Consolidation percentage in the lyophilized group was significantly lower than in the frozen and control groups. Length of time for consolidation was not different between the groups. Brevibacterium spp. was isolated from one of the implants preserved in honey. In conclusion, bone grafts preserved in honey or frozen at -70°C were effective for repairing cortical defects in the femurs of adult cats as compared to autologous bone. Lyophilized implants require more evaluation of resistance and immunogenicity before they can be considered a viable option for bone repair in cats.
|
9 |
Avaliação da aplicação de um campo magnético permanente sepultado em área de enxerto ósseo alógeno e dento-alveolar : estudo experimental em ratosAzambuja, Henrique Voltolini de January 2007 (has links)
Proposição: O presente trabalho propõe o estudo histológico descritivo da aplicação de um campo magnético sepultado, estático e permanente em área de enxerto ósseo alógeno liofilizado e dento-alveolar associada a defeito cirúrgico em mandíbulas de ratos. Metodologia: estudo experimental in vivo, randomizado. Amostra foi composta por 21 ratos, da espécie Rattus novergicus albinus, linhagem Wistar, machos, divididos em três grupos, correspondendo aos tempos experimentais de sete, 21 e 45 dias. Foram realizadas ostectomias associadas a odontossecções, na face lateral externa do corpo mandibular e no ramo ascendente, atingindo transversalmente a raiz do incisivo inferior e os ápices dos molares. Este defeito cirúrgico permitiu a adaptação de dispositivos metálicos magnetizados (grupo teste) e não magnetizados (grupo controle) associados às regiões apicais dos molares e ao coto distal do incisivo inferior, local este onde realizou-se enxertia óssea alógena liofilizada. A intensidade média do campo magnético sepultado e permanente foi de 250 gauss.Resultados: observou-se no grupo teste e controle, nos diferentes tempos experimentais a gradativa integração do enxerto ósseo alógeno liofilizado, a manutenção da vitalidade pulpar dos molares e coto proximal do incisivo inferior, além da contínua erupção do incisivo inferior do rato. Nos grupos teste, principalmente aos 45 dias, constatou-se uma diferenciada e exuberante neoformação óssea centrípeta em direção aos dispositivos metálicos imantados. Conclusão: o campo magnético sepultado in vivo foi capaz de favorecer o processo de cicatrização óssea no defeito cirúrgico criado. / Purpose: The present study provides a descriptive histological analysis of the use of a buried, static and permanent magnetic field in lyophilized bone allografts in a dentoalveolar area associated with surgical defects in rat mandibles. Method: a randomized in vivo experimental study was carried out with 21 male Wistar rats (Rattus norvegicus albinus), which were split into three groups, corresponding to 7, 21 and 45 experimental days. Ostectomies associated with odontotomies were performed on the outer lateral face of the mandibular body and in the ascending branch, cross-sectionally to the root of the lower incisor and to the molar apices. This surgical defect allowed for the use of magnetized (test group) and non-magnetized (control group) metal devices associated with molar apices and with the distal stump of the lower incisor, where the lyophilized bone allograft was performed. The intensity of the buried and permanent magnetic field amounted to 250 gauss. Results: In the test and control groups, there was gradual integration of the lyophilized bone allograft, maintenance of pulp vitality of the molars and of the proximal stump of the lower incisor, in addition to continuous eruption of the lower incisor. In the test groups, especially at 45 days, there was distinct and pronounced centripetal new bone formation in a direction toward the magnetized metal devices. Conclusion: the in vivo buried magnetic field favored bone healing at the site of the surgical defect.
|
10 |
Comparação de enxerto ósseo cortical autógeno e implante ósseo cortical alógeno liofilizado, congelado a -70ºC ou conservado no mel na substituição de segmento diafisário do fêmur de gatos domésticos.Ferreira, Márcio Poletto January 2008 (has links)
Os felinos domésticos há muito tempo são utilizados como animais de companhia, tornando freqüentes os atendimentos veterinários a esta espécie. As afecções ortopédicas em gatos ocupam papel de destaque na rotina do traumatologista veterinário, que pode deparar-se com fraturas cominutivas de ossos longos, neoplasias ósseas, não-uniões ou uniões-viciosas de fraturas. Uma das opções para o tratamento dessas afecções é a utilização de enxerto ou implante ósseo. O objetivo deste trabalho foi avaliar implantes ósseos corticais alógenos conservados em mel, congelados a -70°C ou liofilizados na substituição de segmento diafisário do fêmur de felinos domésticos. Foi confeccionada uma falha óssea de três centímetros na região diáfisária do fêmur de 24 felinos adultos. Em seis felinos (grupo controle), a falha foi preenchida com o próprio osso removido após a retirada do periósteo, endósteo e medula óssea, e em outros 18 animais, foi preenchida com implantes ósseos corticais alógenos conservados em mel (seis animais), congelado (seis animais) e liofilizado (seis animais). Os animais foram avaliados clínica, radiográfica e histologicamente até completarem 180 dias de pós-operatório. A porcentagem de incorporação foi de 91,6% no grupo controle, com tempo médio necessário para consolidação de 83,1 dias; no grupo mel foi de 75%, com tempo médio de 105 dias; no grupo congelado foi de 83,3% com tempo médio de 78 dias e no grupo liofilizado foi de 25%, com tempo médio de 120 dias. Foi encontrada diferença estatisticamente significativa entre as porcentagens de consolidação do grupo liofilizado em relação aos grupos congelado e controle. Não houve diferença estatística entre os grupos com relação ao tempo de consolidação. Foi identificada a bactéria Brevibacterium spp. em um dos implantes conservados no mel. Foi possível concluir que os implantes ósseos autógenos e os conservados no mel e a -70°C foram eficazes no preenchimento de defeito cortical em fêmur de felinos adultos, enquanto que os implantes liofilizados necessitam de maior avaliação da resistência e imunogenicidade para tornarem-se uma opção viável em felinos. / Cats with orthopedic conditions are a prominent part of the clinical work of veterinary traumatologists. Conditions such as comminuted fractures of the long bones, bone cancers and non-unions or unions that repeatedly fracture are often difficult to repair surgically and may require the use of bone grafts or implants for successful treatment. This study evaluated cortical bone allografts preserved in honey, frozen at -70°C or lyophilized for correcting 3 cm long bone defects created in the diaphysis of the right femur of adult domestic cats (n=24). In the control group (n=6), the defect was repaired using the autologous bone following removal of the periosteum, endosteum and bone marrow. In the remaining animals (n=6/group), the defect was repaired with cortical bone allografts preserved in honey, frozen or lyophilized. Success of implant incorporation and length of time for consolidation were assessed through clinical, radiographic and histological evaluations performed up to 180 days after surgery. In the control, frozen, honey and lyophylized groups, respectively, success of implant incorporation was 91.6%, 83.3%, 75%, and 25%, with corresponding mean length of time for consolidation of 83.1, 78, 105 and 120 days. Consolidation percentage in the lyophilized group was significantly lower than in the frozen and control groups. Length of time for consolidation was not different between the groups. Brevibacterium spp. was isolated from one of the implants preserved in honey. In conclusion, bone grafts preserved in honey or frozen at -70°C were effective for repairing cortical defects in the femurs of adult cats as compared to autologous bone. Lyophilized implants require more evaluation of resistance and immunogenicity before they can be considered a viable option for bone repair in cats.
|
Page generated in 0.0545 seconds