• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo anatômico da polia A1: localização por referência cutânea na superfície palmar / Anatomical study of the A1 pulley: location by means of cutaneous references on the palmar surface

Fiorini Júnior, Haroldo [UNIFESP] 25 November 2009 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-11-25. Added 1 bitstream(s) on 2015-08-11T03:26:32Z : No. of bitstreams: 1 Publico-549%20-%2011769.pdf: 1027011 bytes, checksum: 549288ebc09400ab5c317f529c1f6f07 (MD5) / Objetivo: Estabelecer parâmetros da superfície palmar para localização precisa do limite proximal da polia flexora A1, nos dedos indicador, médio, anular e mínimo, e avaliar o comprimento dessa polia. Métodos: Foram estudados 280 dedos de 70 mãos de 35 cadáveres frescos, mensurando-se inicialmente a distância entre as pregas digitopalmar e interfalangeana proximal (medida A), seguindo-se com a dissecação dos dedos e mensuração da distância entre o limite proximal da polia A1 e a prega digitopalmar (medida B), bem como o comprimento da polia A1 (medida C), em cada dedo. A análise estatística foi feita com a utilização do teste multivariado “T²” de Hotelling e do teste “t” para amostras pareadas. Resultados: Após a análise estatística, foi constatado que não há diferença significante entre as medidas A e B em cada dedo (p-valor > 0,05). Também não se evidenciou diferença significante (p-valor > 0,05) entre as medidas correspondentes para cada dedo de ambas as mãos (AxA), (BxB) e (CxC). Foi observado que o comprimento médio da polia A1 em milímetros no dedo indicador é de 9,83; no médio, de 10,71; no anular, de 9,66, e, no mínimo, de 8,06. Conclusões: A distância entre as pregas digitopalmar e interfalangeana proximal deve ser usada como referência cutânea da superfície palmar para a localização precisa do limite proximal da polia A1 na palma da mão, dando mais segurança na realização de procedimentos cirúrgicos como a liberação percutânea do “dedo em gatilho”. / Purpose: We conducted this study to establish palmar surface parameters to allow for the exact location of the proximal limit of the flexor tendon A1 pulley in the index, middle, ring and little fingers and to evaluate the length of this pulley. Methods: We studied 280 fingers on 70 hands of 35 fresh human cadavers, initially measuring the distance between the digital-palmar and proximal interphalangeal creases (measure A), followed by dissection of the fingers and measurement of the distance between the proximal limit of the A1 pulley and the digital-palmar crease (measure B) and the length of the A1 pulley (measure C). A statistical analysis was carried out using Hotelling’s multivariate T2 test and the paired samples t-test. Results: No statistically significant difference was found between measures A and B in each finger (p > 0.05). The average length of the A1 pulley, in millimeters, was 9.83 in the index finger, 10.71 in the middle finger, 9.66 in the ring finger, and 8.06 in the little finger. Conclusions: The distance between the digital-palmar and proximal interphalangeal creases should be used as a cutaneous reference of the palmar surface for the exact location of the proximal limit of the A1 pulley in the palm of the hand, ensuring greater safety in surgical procedures such as percutaneous release of trigger finger. / TEDE / BV UNIFESP: Teses e dissertações
2

Avaliação da ressonância magnética da mão dominante na artrite reumatóide precoce: correlação com a radiologia convencional / Hand magnetic resonance evaluation of early rheumatoid arthritis: correlation with conventional radiography

Vitule, Luiz Fernando 16 January 2007 (has links)
A artrite reumatóide (AR) é uma patologia crônica e sistêmica de etiologia desconhecida provavelmente multifatorial na qual há um predomínio de acometimento da sinóvia. Afeta de 0,5 a 1 % da população com predomínio nas mulheres. O diagnóstico precoce e o inicio da terapêutica adequada são fundamentais e podem modificar a evolução da doença reduzindo as graves seqüelas. O custo do exame de ressonância magnética (RM) é a maior limitação neste método de diagnóstico. O objetivo deste estudo foi avaliar a especificidade e a sensibilidade da ressonância magnética (RM) da mão e do punho de pacientes com AR precoce de acordo com os parâmetros do OMERACT (comitê internacional para avaliação de medidas em reumatologia para análise da ressonância magnética) correlacionando com a radiologia convencional. Foram avaliados 19 pacientes com AR (idade: 22-64 anos) e um grupo controle composto por 10 indivíduos sem história de patologias prévias com idade de 26-46 anos. Foram realizados exames de radiografia (RX) e RM da mão e do punho dominante. Treze articulações foram avaliadas pelo RX convencional (radio-ulnar distal, radiocarpal, intercarpal e metacarpofalângicas do primeiro ao quinto dedo e articulação interfalângicas proximais do primeiro ao quinto dedo). As lesões ósseas no RX foram classificadas de acordo com o método de Van Der Heiidje com graduações de 0 a 4 para redução do espaço articular e de 0 a 5 para erosão óssea. Foram realizados exames de RM num equipamento marca GE 1,5 T Signa Horizon LX (General Eletric medical systems) utilizando T1, T2 eco de spin e T1 eco de Spin com saturação de gordura após a infusão do contraste paramagnético gadopentato dimegumina. O protocolo foi realizado de acordo com as padronizações do OMERACT. Como resultados obtivemos que a RM foi mais sensível na pesquisa de erosão óssea (94,7%) que o RX (78,9%). Somente as articulações intercarpais e metacarpo-falângicas do segundo dedo demonstraram correlação estatística entre os 2 métodos (r=0,47 p=0,04 e r=0,63 p=0,004). Para erosão óssea os compartimentos radiocarpal (73,7%) e intercarpal (84,2%) foram os mais sensíveis e com maior acurácia. Além disso, a RM foi muito sensível no estudo da sinovite presente em 100% dos pacientes com AR comparados com 20% do grupo controle. Quando estudados nos sítios anatômicos o carpo foi o local mais sensível para a sinovite (100%). O edema intra-ósseo foi mais detectado no punho com uma alta especificidade (90%), porém com baixa acurácia (50%) um achado importante é que a analise simultânea do punho e da mão não aumentou a detecção de um maior número de pacientes com AR. Concluindo, a RM foi mais sensível que o RX no estudo da AR precoce. Este trabalho demonstrou que o estudo do punho apresentou uma ótima sensibilidade e especificidade no diagnóstico precoce da AR e somente o estudo deste compartimento parece ser adequado com redução do custo do exame para os pacientes, portanto na análise do AR precoce o punho parece apresentar melhor desempenho. / Rheumatoid arthritis (RA) is a chronic and systemic disease of unknown etiology probably multifactorial with a predominant involvement of synovial tissue. The disease prevalence is 0.5-1% and affects more often women. Early diagnosis and therapy are essential to modify the course of the disease and reduce the degree of severe late sequelae. The cost of MRI of this region is a major limitation for the use of this sensitive exam. We therefore decided to evaluate if the wrist magnetic resonance with a simultaneous reading of wrist and hand compartments according to the OMERACT parameters would be sensitive and accurate to diagnose early RA. We have evaluated 19 patients with RA (ages: 22-64 years) and 10 age-matched controls. X-ray and MRI evaluated the dominant wrist all subjects. Thirteen joints were evaluated by conventional radiography: radio-ulnar distal (DRU), radiocarpal joint (RC), intercarpal (IC), metacarpo-phalageal (first to fifth finger) and phalangophalangeal (first to fifth finger). The bone lesion in the radiograph was scored by the method of Van Der Heidje for joint damage and for joint narrowing space. Wrist MRI imaging was performed with 1,5 T GE Signa Horizon LX 8,2 (General Eletric medical systems) with multiplanar T1, T2 (spin echo and fast spin echo) and T1 fat sat after intravenous injection of gadopentetate dimeglumine, according to the definitions of OMERACT. The MRI was more sensitive to detect erosion (94.7%) than the conventional X-ray (78.9%), and only intercarpal and metacarpofalangic joints of the second finger showed statistic correlation in the two methods (r=0.47 p=0.04 e r= 0.63 p=0.004). Of interest, among the anatomic compartments evaluated the radiocarpal (73.7%) and intercarpal joints (84.2%) were the most sensitive and accurate to detect erosion. Moreover, the MRI was also very sensitive to detect synovitis, present in 100% of the AR compared 20% in the control group, p<0,001. With regards to the anatomic site, synovitis was uniformly observed in all carpal joints (100%). Edema was also more frequently detected in the wrist joints with a high specificity (90%) but low accuracy (50%). Importantly, the simultaneous reading of wrist and hands did not identify additional cases. MRI imaging was more sensitive than conventional radiography in detecting early lesion in RA Our data support the notion that wrist MRI has an excellent sensitivity and specificity to diagnose early RA, and therefore only this assessment seems to be adequate, with a reduced cost for the patients. Additionally, we have demonstrated that the reading may be restrict to the wrist compartment, overcoming the technical limitations of the hand anatomical site.
3

Avaliação da ressonância magnética da mão dominante na artrite reumatóide precoce: correlação com a radiologia convencional / Hand magnetic resonance evaluation of early rheumatoid arthritis: correlation with conventional radiography

Luiz Fernando Vitule 16 January 2007 (has links)
A artrite reumatóide (AR) é uma patologia crônica e sistêmica de etiologia desconhecida provavelmente multifatorial na qual há um predomínio de acometimento da sinóvia. Afeta de 0,5 a 1 % da população com predomínio nas mulheres. O diagnóstico precoce e o inicio da terapêutica adequada são fundamentais e podem modificar a evolução da doença reduzindo as graves seqüelas. O custo do exame de ressonância magnética (RM) é a maior limitação neste método de diagnóstico. O objetivo deste estudo foi avaliar a especificidade e a sensibilidade da ressonância magnética (RM) da mão e do punho de pacientes com AR precoce de acordo com os parâmetros do OMERACT (comitê internacional para avaliação de medidas em reumatologia para análise da ressonância magnética) correlacionando com a radiologia convencional. Foram avaliados 19 pacientes com AR (idade: 22-64 anos) e um grupo controle composto por 10 indivíduos sem história de patologias prévias com idade de 26-46 anos. Foram realizados exames de radiografia (RX) e RM da mão e do punho dominante. Treze articulações foram avaliadas pelo RX convencional (radio-ulnar distal, radiocarpal, intercarpal e metacarpofalângicas do primeiro ao quinto dedo e articulação interfalângicas proximais do primeiro ao quinto dedo). As lesões ósseas no RX foram classificadas de acordo com o método de Van Der Heiidje com graduações de 0 a 4 para redução do espaço articular e de 0 a 5 para erosão óssea. Foram realizados exames de RM num equipamento marca GE 1,5 T Signa Horizon LX (General Eletric medical systems) utilizando T1, T2 eco de spin e T1 eco de Spin com saturação de gordura após a infusão do contraste paramagnético gadopentato dimegumina. O protocolo foi realizado de acordo com as padronizações do OMERACT. Como resultados obtivemos que a RM foi mais sensível na pesquisa de erosão óssea (94,7%) que o RX (78,9%). Somente as articulações intercarpais e metacarpo-falângicas do segundo dedo demonstraram correlação estatística entre os 2 métodos (r=0,47 p=0,04 e r=0,63 p=0,004). Para erosão óssea os compartimentos radiocarpal (73,7%) e intercarpal (84,2%) foram os mais sensíveis e com maior acurácia. Além disso, a RM foi muito sensível no estudo da sinovite presente em 100% dos pacientes com AR comparados com 20% do grupo controle. Quando estudados nos sítios anatômicos o carpo foi o local mais sensível para a sinovite (100%). O edema intra-ósseo foi mais detectado no punho com uma alta especificidade (90%), porém com baixa acurácia (50%) um achado importante é que a analise simultânea do punho e da mão não aumentou a detecção de um maior número de pacientes com AR. Concluindo, a RM foi mais sensível que o RX no estudo da AR precoce. Este trabalho demonstrou que o estudo do punho apresentou uma ótima sensibilidade e especificidade no diagnóstico precoce da AR e somente o estudo deste compartimento parece ser adequado com redução do custo do exame para os pacientes, portanto na análise do AR precoce o punho parece apresentar melhor desempenho. / Rheumatoid arthritis (RA) is a chronic and systemic disease of unknown etiology probably multifactorial with a predominant involvement of synovial tissue. The disease prevalence is 0.5-1% and affects more often women. Early diagnosis and therapy are essential to modify the course of the disease and reduce the degree of severe late sequelae. The cost of MRI of this region is a major limitation for the use of this sensitive exam. We therefore decided to evaluate if the wrist magnetic resonance with a simultaneous reading of wrist and hand compartments according to the OMERACT parameters would be sensitive and accurate to diagnose early RA. We have evaluated 19 patients with RA (ages: 22-64 years) and 10 age-matched controls. X-ray and MRI evaluated the dominant wrist all subjects. Thirteen joints were evaluated by conventional radiography: radio-ulnar distal (DRU), radiocarpal joint (RC), intercarpal (IC), metacarpo-phalageal (first to fifth finger) and phalangophalangeal (first to fifth finger). The bone lesion in the radiograph was scored by the method of Van Der Heidje for joint damage and for joint narrowing space. Wrist MRI imaging was performed with 1,5 T GE Signa Horizon LX 8,2 (General Eletric medical systems) with multiplanar T1, T2 (spin echo and fast spin echo) and T1 fat sat after intravenous injection of gadopentetate dimeglumine, according to the definitions of OMERACT. The MRI was more sensitive to detect erosion (94.7%) than the conventional X-ray (78.9%), and only intercarpal and metacarpofalangic joints of the second finger showed statistic correlation in the two methods (r=0.47 p=0.04 e r= 0.63 p=0.004). Of interest, among the anatomic compartments evaluated the radiocarpal (73.7%) and intercarpal joints (84.2%) were the most sensitive and accurate to detect erosion. Moreover, the MRI was also very sensitive to detect synovitis, present in 100% of the AR compared 20% in the control group, p<0,001. With regards to the anatomic site, synovitis was uniformly observed in all carpal joints (100%). Edema was also more frequently detected in the wrist joints with a high specificity (90%) but low accuracy (50%). Importantly, the simultaneous reading of wrist and hands did not identify additional cases. MRI imaging was more sensitive than conventional radiography in detecting early lesion in RA Our data support the notion that wrist MRI has an excellent sensitivity and specificity to diagnose early RA, and therefore only this assessment seems to be adequate, with a reduced cost for the patients. Additionally, we have demonstrated that the reading may be restrict to the wrist compartment, overcoming the technical limitations of the hand anatomical site.

Page generated in 0.0685 seconds