• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 306
  • 122
  • 56
  • 38
  • 31
  • 20
  • 18
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • Tagged with
  • 756
  • 140
  • 98
  • 66
  • 65
  • 59
  • 56
  • 52
  • 44
  • 42
  • 38
  • 36
  • 35
  • 35
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Spellbound : magic in contemporary fiction

Vollick, L. Erin. January 2007 (has links)
No description available.
12

Dosimetria tridimensional por imagens de ressonância magnética com gel MAGIC modificado / Tri-dimentional dosimetry by Magnetic Resonance Imaging using a modified MAGIC gel dosimeter

Pavoni, Juliana Fernandes 15 May 2009 (has links)
Os avanços nas técnicas de tratamento com radiação ionizante estão gerando distribuições de dose muito complexas que precisam ser verificadas antes da aplicação do tratamento no paciente. Diversos dosímetros já foram propostos para esta verificação, mas o que vem apresentando os melhores resultados são os géis poliméricos que permitem a visualização tridimensional da dose. Neste trabalho desenvolvemos um gel dosimétrico do tipo MAGIC com componentes nacionais, para baratear o custo e assim, facilitar a sua aplicação na rotina clínica. Nós adicionamos formaldeído ao gel para aumentar seu ponto de fusão e facilitar seu manuseio em temperatura ambiente. A avaliação das doses foi feita através da relaxometria em imagens de ressonância magnética nuclear (IRMN). Foi encontrada uma resposta linear para dose de até 15Gy e uma dependência energética significativa para feixes de baixa energia (kVp), enquanto que para alta energia (MV) a dependência encontrada foi pequena. A variação da resposta do dosímetro em função da taxa de dose da irradiação foi menor que 5% nas taxas de 100 a 600cGy/min. A adição de formaldeído não eliminou a dependência da resposta do dosímetro para variações na temperatura durante a aquisição das IRMN, já a integridade da distribuição de dose se manteve inalterada por um período de três meses na irradiação de um campo blindado ao meio. Medidas tridimensionais de distribuição de dose foram realizadas para dois planos de radioterapia com intensidade modulada de feixe o primeiro em um acelerador linear e o segundo em um equipamento de tomoterapia, grande semelhança entre a sobreposição das isodoses e dos perfis de dose das imagens medidas com o gel e esperadas pelo sistema de planejamento (TPS) foi encontrada. A avaliação realmente tridimensional foi feita com os histogramas dose-volume (DVH), sendo que uma sobreposição entre os DVHs calculados para o volume planejado e os esperados pelo TPS foi encontrada nos dois planejamentos. Por tudo o que foi estudado, pode-se concluir que a modificação realizada no gel MAGIC resultou em um dosímetro de fácil manuseio que pode ser aplicado para medidas tridimensionais. / Advances in the treatment techniques with ionizing radiation are resulting in complex dose distributions that need to be verified before the application of the treatment in the patient. Several dosimeters have been suggested for this application, but polymeric gel dosimeters are presenting the best results so far, since they allow three dimensional dose visualization, are tissue equivalent, don\'t have dependence with angular distribution of the incident radiation and have a high spatial resolution. In this work a polymeric gel dosimeter with national components, to reduce de costs and facilitate its introduction in the clinical practice was developed. Formaldehyde was added to the gel formulation to increase its melting temperature and facilitate its use in typical room temperatures found in our country. Dose response analysis was done using nuclear magnetic resonance relaxometry. All the dosimetric characterization was done. We found a linear dose-response curve for doses until 15Gy and significant energy dependence for low energy beams (kVp), but for high energy beams (MV) this dependence is smaller. The response variation when varying the dose rate of irradiation was smaller than 5% in the dose rate range of clinical use in teletherapy (100-600cGy/min). The addition of formaldehyde did not eliminate the dosimeter dependence with variation of the scanning temperature; the integrity of dose distribution was unaltered at least for a tree month period of time in a half beam irradiation phantom. Tri-dimensional dose distributions were measured in two radiotherapy systems using intensity modulated beams, the first one in a linear accelerator and the second in a tomotherapy machine. A high similarity was found between the overlapping of isodoses and dose profiles of the dose distribution measured with the gel and expected by the treatment planning. The real tri- dimensional analysis was done with dose-volume histograms (DVH) and the DVHs measured for the planning volume and expected by the treatment planning were in good agreement. Our results show that the modification done in the gel formulation resulted in a dosimeter easy to handle and feasible for tri-dimensional measurements.
13

Construction methods for vertex magic total labelings of graphs

Gray, Ian January 2006 (has links)
Research Doctorate - Doctor of Philosophy (PhD) / In this thesis, a number of new methods for constructing vertex-magic total-labelings of graphs are presented. These represent an advance on existing methods since they are general constructions rather than ad hoc constructions for specific families of graphs. Broadly, five new kinds of construction methods are presented. Firstly, we present a class of methods characterized by adding 2- or 4-factors to a labeled graph, reassigning vertex labels to the edges of these factors and then adding new vertex labels to create a VMTL of the new graph. The major result is a unified method for constructing VMTL of large families of regular graphs, providing strong evidence for MacDougall's conjecture that, apart from a few minor exceptions, all regular graphs possess vertex-magic total-labelings. Secondly, we present methods for obtaining a labeling of a union of two graphs, one of which possesses a strong labeling, and then building on this labeling to create a labeling of an irregular graph. These methods as well as results in the Appendices provide strong evidence against an early conjecture regarding labelings and vertex degrees. Thirdly, constructions are presented for a new kind of magic square, containing some zeroes, which can be used to build labelings of graphs from labeled spanning subgraphs. Next, constructions are presented for a new kind of anti-magic square, containing some zeroes, which is equivalent to a strong labeling of certain kinds of bipartite graphs which can in turn be built upon to produce labelings of graphs with more edges. Finally, we present a method of mutating a graph labeling by reassigning edges in a way that preserves the magic constant to obtain a labeling of a different graph. This method provides a prolific source of new labelings.
14

Construction methods for vertex magic total labelings of graphs

Gray, Ian January 2006 (has links)
Research Doctorate - Doctor of Philosophy (PhD) / In this thesis, a number of new methods for constructing vertex-magic total-labelings of graphs are presented. These represent an advance on existing methods since they are general constructions rather than ad hoc constructions for specific families of graphs. Broadly, five new kinds of construction methods are presented. Firstly, we present a class of methods characterized by adding 2- or 4-factors to a labeled graph, reassigning vertex labels to the edges of these factors and then adding new vertex labels to create a VMTL of the new graph. The major result is a unified method for constructing VMTL of large families of regular graphs, providing strong evidence for MacDougall's conjecture that, apart from a few minor exceptions, all regular graphs possess vertex-magic total-labelings. Secondly, we present methods for obtaining a labeling of a union of two graphs, one of which possesses a strong labeling, and then building on this labeling to create a labeling of an irregular graph. These methods as well as results in the Appendices provide strong evidence against an early conjecture regarding labelings and vertex degrees. Thirdly, constructions are presented for a new kind of magic square, containing some zeroes, which can be used to build labelings of graphs from labeled spanning subgraphs. Next, constructions are presented for a new kind of anti-magic square, containing some zeroes, which is equivalent to a strong labeling of certain kinds of bipartite graphs which can in turn be built upon to produce labelings of graphs with more edges. Finally, we present a method of mutating a graph labeling by reassigning edges in a way that preserves the magic constant to obtain a labeling of a different graph. This method provides a prolific source of new labelings.
15

Dosimetria tridimensional por imagens de ressonância magnética com gel MAGIC modificado / Tri-dimentional dosimetry by Magnetic Resonance Imaging using a modified MAGIC gel dosimeter

Juliana Fernandes Pavoni 15 May 2009 (has links)
Os avanços nas técnicas de tratamento com radiação ionizante estão gerando distribuições de dose muito complexas que precisam ser verificadas antes da aplicação do tratamento no paciente. Diversos dosímetros já foram propostos para esta verificação, mas o que vem apresentando os melhores resultados são os géis poliméricos que permitem a visualização tridimensional da dose. Neste trabalho desenvolvemos um gel dosimétrico do tipo MAGIC com componentes nacionais, para baratear o custo e assim, facilitar a sua aplicação na rotina clínica. Nós adicionamos formaldeído ao gel para aumentar seu ponto de fusão e facilitar seu manuseio em temperatura ambiente. A avaliação das doses foi feita através da relaxometria em imagens de ressonância magnética nuclear (IRMN). Foi encontrada uma resposta linear para dose de até 15Gy e uma dependência energética significativa para feixes de baixa energia (kVp), enquanto que para alta energia (MV) a dependência encontrada foi pequena. A variação da resposta do dosímetro em função da taxa de dose da irradiação foi menor que 5% nas taxas de 100 a 600cGy/min. A adição de formaldeído não eliminou a dependência da resposta do dosímetro para variações na temperatura durante a aquisição das IRMN, já a integridade da distribuição de dose se manteve inalterada por um período de três meses na irradiação de um campo blindado ao meio. Medidas tridimensionais de distribuição de dose foram realizadas para dois planos de radioterapia com intensidade modulada de feixe o primeiro em um acelerador linear e o segundo em um equipamento de tomoterapia, grande semelhança entre a sobreposição das isodoses e dos perfis de dose das imagens medidas com o gel e esperadas pelo sistema de planejamento (TPS) foi encontrada. A avaliação realmente tridimensional foi feita com os histogramas dose-volume (DVH), sendo que uma sobreposição entre os DVHs calculados para o volume planejado e os esperados pelo TPS foi encontrada nos dois planejamentos. Por tudo o que foi estudado, pode-se concluir que a modificação realizada no gel MAGIC resultou em um dosímetro de fácil manuseio que pode ser aplicado para medidas tridimensionais. / Advances in the treatment techniques with ionizing radiation are resulting in complex dose distributions that need to be verified before the application of the treatment in the patient. Several dosimeters have been suggested for this application, but polymeric gel dosimeters are presenting the best results so far, since they allow three dimensional dose visualization, are tissue equivalent, don\'t have dependence with angular distribution of the incident radiation and have a high spatial resolution. In this work a polymeric gel dosimeter with national components, to reduce de costs and facilitate its introduction in the clinical practice was developed. Formaldehyde was added to the gel formulation to increase its melting temperature and facilitate its use in typical room temperatures found in our country. Dose response analysis was done using nuclear magnetic resonance relaxometry. All the dosimetric characterization was done. We found a linear dose-response curve for doses until 15Gy and significant energy dependence for low energy beams (kVp), but for high energy beams (MV) this dependence is smaller. The response variation when varying the dose rate of irradiation was smaller than 5% in the dose rate range of clinical use in teletherapy (100-600cGy/min). The addition of formaldehyde did not eliminate the dosimeter dependence with variation of the scanning temperature; the integrity of dose distribution was unaltered at least for a tree month period of time in a half beam irradiation phantom. Tri-dimensional dose distributions were measured in two radiotherapy systems using intensity modulated beams, the first one in a linear accelerator and the second in a tomotherapy machine. A high similarity was found between the overlapping of isodoses and dose profiles of the dose distribution measured with the gel and expected by the treatment planning. The real tri- dimensional analysis was done with dose-volume histograms (DVH) and the DVHs measured for the planning volume and expected by the treatment planning were in good agreement. Our results show that the modification done in the gel formulation resulted in a dosimeter easy to handle and feasible for tri-dimensional measurements.
16

Carnivalesque adventures in Kiss of the spider woman and Nights at thecircus

Chan, Siu-wai, Sylvia., 陳小惠. January 2004 (has links)
published_or_final_version / abstract / toc / Literary and Cultural Studies / Master / Master of Arts
17

Magic realism and `root-searching' in the works of Mo Yan, Zhaxi Dawa and Han Shaogong

邱偉平, Yau, Wai-ping. January 1996 (has links)
published_or_final_version / Comparative Literature / Master / Master of Philosophy
18

New methodologies in solid state NMR

Crockford, Charles January 2002 (has links)
No description available.
19

Multiple-quantum MAS NMR of half-integer quadrupolar nuclei

Brown, Steven Paul January 1997 (has links)
No description available.
20

Construction of sets of mutually orthogonal Latin squares

Cadek, Glenn Charles January 2010 (has links)
Digitized by Kansas Correctional Industries

Page generated in 0.0448 seconds