• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 4
  • Tagged with
  • 15
  • 15
  • 10
  • 10
  • 9
  • 8
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Resultados funcionales en el manejo conservador kinésico de pacientes mayores de 40 años con primer episodio de luxación anterior traumática de hombro, y su asociación con lesiones de manguito rotador

Boettcher Manterola, Karin, Fingerhuth Crignola, Daniela January 2004 (has links)
La luxación anterior traumática de hombro es una patología de alta prevalencia en personas mayores de 40 años, sin embargo, este grupo etario ha sido poco estudiado. En estos pacientes, el principal problema planteado se relaciona con patologías del Manguito Rotador, cuya consecuencia es una alteración funcional, a diferencia de pacientes de menor edad en las cuales los episodios de luxación se relacionan con inestabilidad. En el presente estudio se evaluó el Estado Funcional en pacientes mayores de 40 años con un primer episodio de luxación anterior traumática de hombro luego de un tratamiento conservador que consistió en inmovilización por una semana con cabestrillo y, posterior a ello, manejo kinésico durante 3 semanas para luego establecer la asociación entre funcionalidad y lesión del Manguito Rotador. El estudio fue realizado en el Instituto Traumatológico de Santiago, entre Marzo y Octubre del año 2004. La muestra fue de de 22 pacientes, 7 hombres y 15 mujeres mayores de 40 años (68,2 + 9,42). Dicha muestra fue tomada por conveniencia. Dentro de la recolección de datos se utilizó una ficha de datos de la Evaluación Funcional y un informe imagenológico de ecografía. Cada paciente fue tratado con un manejo conservador kinésico. A la cuarta semana posterior a la luxación, se le realizó una Evaluación Funcional mediante el test de UCLA modificado. Para el análisis de los resultados se utilizó el programa STATA 7.0. Del total de los sujetos en estudio, 2 no presentaron lesión del Manguito Rotador, 1 presentó lesión parcial y 19 lesión total. Mediante el test de UCLA modificado, se obtuvo que 2 presentaron resultados excelentes, 6 buenos y 14 deficientes. La asociación entre luxación anterior de hombro y lesión de Manguito Rotador no fue estadísticamente significativa (P=0,12) según la prueba exacta de Fisher (P = 0,05). Se concluye en este estudio, que no existe asociación entre Lesión de Manguito Rotador y el Estado Funcional de los pacientes mayores de 40 años con un primer episodio de luxación anterior traumática de hombro, luego de haber sido sometidos a un tratamiento conservador kinésico en el Instituto Traumatológico. Los sujetos en estudio presentaron una alta prevalencia (91%) de lesión del Manguito Rotador, sin asociación entre las variables estudiadas. / Shoulder´s traumatic anterior dislocation is a pathology of high prevalence in patients older than 40 years. However this group of age has not been studied enough. The main problem in this group is the lesion of Rotator Cuff associated to the dislocation, compared to younger patients in which dislocations are related to shoulder instability. In this study, we evaluated de Functionality of the patients older than forty years of age, with a primary traumatic anterior dislocation of the shoulder after a conservative treatment which consisted in inmovilization of the shoulder with a sling for one week and a physiotherapy program during three weeks, to then associate the Functionality with the lesion of the Rotator Cuff. The study was done in the Traumatologic Institute of Santiago, between march and October of the year 2004. 22 patients, 7 males and 15 females older than 40 years of age (68,2 + 9,42), were treated during this period. To recollect the information we used a data file of the UCLA score and a ultrasound ecography. Each patient was treated in a conservatory way after shoulder dislocation. At the fourth week after the dislocation we evaluated the Functionality with the UCLA score. To analize the results we used the program STATA 7.0. From the total of the patients 2 didn´t present lesion of the Rotator Cuff, 1 had parcial lesion and 19 had total lesion. In the UCLA score, 2 patients obtained excellent results, 6 good results and 14 deficient. The association between the Rotator Cuff lesion and Functionality was statistically not significative ( P = 0, 12), according to the Fisher exact test. In this study, we concluded that there is no association between Rotator Cuff lesion and Functionality of the patients older than forty years old with a primary traumatic anterior shoulder dislocation, after a conservative treatment. Also, we concluded that the Rotator Cuff pathology associated to the dislocation in this type of patients was of high prevalence (91%).
2

Estudo comparativo entre artrotomografia computadorizada multislice e artroscopia na avalia????o das les??es do manguito rotador

Vieira, Luis Alfredo G??mez 24 January 2018 (has links)
Submitted by Carla Santos (biblioteca.cp2.carla@bahiana.edu.br) on 2018-09-04T19:11:17Z No. of bitstreams: 1 Luis Alfredo - Disserta????o final.pdf: 2671461 bytes, checksum: d4e61e01eed618b8afa9c20cd4b7976a (MD5) / Approved for entry into archive by JOELMA MAIA (ebmsp-bibliotecacp2@bahiana.edu.br) on 2018-09-04T20:32:52Z (GMT) No. of bitstreams: 1 Luis Alfredo - Disserta????o final.pdf: 2671461 bytes, checksum: d4e61e01eed618b8afa9c20cd4b7976a (MD5) / Made available in DSpace on 2018-09-04T20:32:52Z (GMT). No. of bitstreams: 1 Luis Alfredo - Disserta????o final.pdf: 2671461 bytes, checksum: d4e61e01eed618b8afa9c20cd4b7976a (MD5) Previous issue date: 2018-01-24 / INTRODU????O.As les??es que afetam o manguito rotador est??o entre as mais frequentes causas de dor no ombro. A artrotomografia computadorizada ???multislice??? (artroTCMS) possibilita a obten????o de imagens diagn??sticas, multiplanares e reconstru????es tridimensionais do ombro tendo a grande vantagem de ter um menor custo e r??pida realiza????o com menor desconforto para o paciente se comparado com o exame de resson??ncia magn??tica, no entanto, estudos cient??ficos s??o necess??rios para a confirma????o da efic??cia da aplica????o da artroTCMS na avalia????o da les??o do manguito rotador do ombro.OBJETIVO.Comparar os achados por imagem das altera????es anat??micas da artrotomografia computadorizada ???multislice??? com os achados artrosc??picos na avalia????o das les??es do manguito rotador do ombro.METODOLOGIA. Feito estudo longitudinal, prospectivo, comparativo de acur??cia diagn??stica entre junho de 2016 a junho de 2017, em pacientes de ambos sexos com idade entre 40-70 anos com les??o dos tend??es do manguito rotador do ombro. Ap??s a realiza????o da artroTCMS, todos os pacientes foram submetidos a artroscopia. Com a artroscopia considerada como exame padr??o-ouro, utilizando o programa SPSS (Statistical Package for Social Sciences), vers??o 21, para a obten????o dos resultados foram determinados os seguintes par??metros: sensibilidade, especificidade, acur??cia, valor preditivo positivo, valor preditivo negativo e kappa contrapondo o m??todo de imagem (artroTCMS) com a artroscopia. RESULTADOS. As vari??veis cl??nicas observadas nos pacientes inclu??ram claustrofobia, doen??as cardiovasculares, presen??a de implantes met??licos e comorbidades diversas. A anormalidade mais comum visualizada na artroscopia foi a les??o do tend??o do m??sculo supraespinalevidente, tamb??m, em todos os casos deste estudo na artroTCMS. Em 27 pacientes, a artroscopia detectou les??es do maguito rotador. J?? a artroTCMS demonstrou no estudo a identifica????o da les??o em 20 pacientes.CONCLUS??O.A artroTCMS mostrou-se eficaz na avalia????o das les??es do manguito rotador com resultados semelhantes aos da artroscopia podendo ser utilizada como um exame imagenol??gico alternativo de elei????o no diagn??stico dasles??es do manguito rotador do ombro.
3

Validade e confiabilidade da ressonância magnética para o diagnóstico da rotura do tendão do subescapular / Validity and reliability of magnetic resonance imaging for the diagnosis of subscapularis tendon tear

Ramadan, Lucas Busnardo 19 September 2018 (has links)
INTRODUCÃO: A acurácia da ressonância magnetica (RM) para a detecção de rotura do subescapular apresenta ampla variação na literatura. Existem poucos estudos prospectivos e grande variação metodológica. Acredita-se que estas roturas sejam mais dificilmente diagnosticadas do que as posterossuperiores. O tendão do subescapular apresenta importância na biomecânica no ombro e sua rotura leva a prejuízo funcional. Uma ferramenta diagnóstica de boa acurácia é fundamental na prática clínica, influenciando o prognóstico e o planejamento cirúrgico. O objetivo deste estudo foi avaliar a validade da RM pre-operatória na identificação das roturas do subescapular, comparando os achados de imagem com os dados intra-operatórios de cirurgia artroscó pica. Como objetivo secundário, avaliamos a confiabilidade do método, por meio da concordância interobservador e intraobservador. MÈTODOS: Realizamos um estudo de acurácia diagnóstica comparando os achados da RM (teste índice) com os da artroscopia (teste de referência), em uma coorte prospectiva. Foram incluídos pacientes submetidos a artroscopia para tratamento de roturas do manguito rotador que houvessem realizado RM de alto campo magnético, sem uso de contraste. Foram excluídos casos de manipulacão cirúrgica pregressa no ombro, exames com artefatos de movimentação, indicação cirurgia por via aberta e intervalo entre a RM e procedimento cirúrgico superior a um ano. As imagens foram avaliadas por um cirurgião de ombro e dois radiologistas musculoesqueleticos, de maneira independente e cegos em relacão aos resultados da artroscopia, sendo reavaliadas apos 3 meses pelo cirurgião. Calculamos a validade (sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia) e confiabilidade (concordancia inter e intraobservador) da RM em detectar roturas do subescapular. RESULTADOS: Avaliamos 200 ombros. A incidencia de roturas do subescapular foi de 69,5% (41,5% parciais e 28,0% transfixantes). O cirurgião de ombro apresentou sensibilidade de 51,1 a 59,0% e especificidade de 91,7% a 94,4%. Os radiologistas, 83,5 a 87,1% de sensibilidade e 41 a 45,9% de especificidade. A acura?cia variou de 60,5 a 73,0%. Os valores médios de sensibilidade, especificidade e acurácia foram 70,2%, 61,9% e 67,6%, respectivamente. A concordância interobservador foi moderada para a deteccao de roturas do subescapular (coeficiente kappa 0,463, IC 95% 0,383- 0,534, p < 0,001), assim como a intraobservador (coeficiente kappa 0,546, IC 95% 0,430-0,662, p < 0,001). Os pacientes com rotura do subescapular apresentaram maior incidencia de rotura e instabilidade do bíceps, maior degeneração gordurosa do subescapular e média de idade superior. As demais variáveis nao apresentaram diferenças estatisticamente significantes. CONCLUSAO: A RM de alto campo magneético sem contraste apresentou valores médios de sensibilidade, especificidade e acurácia de 70,2%, 61,9% e 67,6%, respectivamente. A sensibilidade foi superior nos radiologistas enquanto a especificidade no cirurgião de ombro. A concordância interobservador e intraobservador foi moderada / INTRODUCTION: The accuracy of magnetic resonance imaging (MRI) for the detection of subscapularis tear presents wide variation in the literature. There are few prospective studies and great methodological variation. It is believed that these tears are more difficult to diagnose than the posterosuperiores rotator cuff injuries. The subscapularis tendon has importance in the biomechanics in the shoulder and its rupture leads to functional impairment. A diagnostic tool of good accuracy is fundamental in clinical practice, influencing prognosis and surgical planning. The aim of this study was to evaluate the validity of preoperative MRI in the identification of the subscapularis tears, comparing the imaging findings with the intraoperative data of arthroscopic surgery. As a secondary objective, we evaluated the reliability of the method through interobserver and intraobserver agreement. METHODS: We performed a diagnostic accuracy study comparing MRI findings (index test) with those of arthroscopy (reference test), in a prospective cohort. We included patients submitted to arthroscopy for the treatment of rotator cuff tears that had undergone high magnetic field MRI without using contrast. Cases of previous surgical manipulation in the shoulder, exams with moving artifacts, indication for open surgery and interval between MRI and surgical procedure of more than one year were excluded. The images were evaluated by a shoulder surgeon and two musculoskeletal radiologists, independently and blinded to the results of arthroscopy, being reassessed after 3 months by the surgeon. We calculated the validity (sensitivity, specificity, positive predictive value, negative predictive value and accuracy) and reliability (inter- and intraobserver agreement) of MR in detecting subscapularis tears. RESULTS: We evaluated 200 shoulders. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% transfixing). The shoulder surgeon showed sensitivity from 51.1 to 59.0% and specificity from 91.7% to 94.4%. The radiologists, 83.5 to 87.1% of sensitivity and 41 to 45.9% of specificity. Accuracy ranged from 60.5 to 73.0%. The mean values of sensitivity, specificity and accuracy were 70.2%, 61.9% and 67.6%, respectively. Interobserver agreement was moderate for the detection of subscapular tears (kappa coefficient 0.463, 95% CI 0.383-0.534, p < 0.001), as well as intraobserver agreement (kappa coefficient 0.546, 95% CI 0.430-0.662, p < 0.001). Patients with subscapular rupture had a higher incidence of biceps rupture and instability, greater fat subscapular degeneration, and higher mean age. The other variables did not present statistically significant differences. CONCLUSION: MRI of high magnetic field without contrast showed mean values of sensitivity, specificity and accuracy of 70.2%, 61.9% and 67.6%, respectively. Sensitivity was higher in radiologists while specificity in the shoulder surgeon. Interobserver and intraobserver agreement was moderate
4

Validade e confiabilidade da ressonância magnética para o diagnóstico da rotura do tendão do subescapular / Validity and reliability of magnetic resonance imaging for the diagnosis of subscapularis tendon tear

Lucas Busnardo Ramadan 19 September 2018 (has links)
INTRODUCÃO: A acurácia da ressonância magnetica (RM) para a detecção de rotura do subescapular apresenta ampla variação na literatura. Existem poucos estudos prospectivos e grande variação metodológica. Acredita-se que estas roturas sejam mais dificilmente diagnosticadas do que as posterossuperiores. O tendão do subescapular apresenta importância na biomecânica no ombro e sua rotura leva a prejuízo funcional. Uma ferramenta diagnóstica de boa acurácia é fundamental na prática clínica, influenciando o prognóstico e o planejamento cirúrgico. O objetivo deste estudo foi avaliar a validade da RM pre-operatória na identificação das roturas do subescapular, comparando os achados de imagem com os dados intra-operatórios de cirurgia artroscó pica. Como objetivo secundário, avaliamos a confiabilidade do método, por meio da concordância interobservador e intraobservador. MÈTODOS: Realizamos um estudo de acurácia diagnóstica comparando os achados da RM (teste índice) com os da artroscopia (teste de referência), em uma coorte prospectiva. Foram incluídos pacientes submetidos a artroscopia para tratamento de roturas do manguito rotador que houvessem realizado RM de alto campo magnético, sem uso de contraste. Foram excluídos casos de manipulacão cirúrgica pregressa no ombro, exames com artefatos de movimentação, indicação cirurgia por via aberta e intervalo entre a RM e procedimento cirúrgico superior a um ano. As imagens foram avaliadas por um cirurgião de ombro e dois radiologistas musculoesqueleticos, de maneira independente e cegos em relacão aos resultados da artroscopia, sendo reavaliadas apos 3 meses pelo cirurgião. Calculamos a validade (sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia) e confiabilidade (concordancia inter e intraobservador) da RM em detectar roturas do subescapular. RESULTADOS: Avaliamos 200 ombros. A incidencia de roturas do subescapular foi de 69,5% (41,5% parciais e 28,0% transfixantes). O cirurgião de ombro apresentou sensibilidade de 51,1 a 59,0% e especificidade de 91,7% a 94,4%. Os radiologistas, 83,5 a 87,1% de sensibilidade e 41 a 45,9% de especificidade. A acura?cia variou de 60,5 a 73,0%. Os valores médios de sensibilidade, especificidade e acurácia foram 70,2%, 61,9% e 67,6%, respectivamente. A concordância interobservador foi moderada para a deteccao de roturas do subescapular (coeficiente kappa 0,463, IC 95% 0,383- 0,534, p < 0,001), assim como a intraobservador (coeficiente kappa 0,546, IC 95% 0,430-0,662, p < 0,001). Os pacientes com rotura do subescapular apresentaram maior incidencia de rotura e instabilidade do bíceps, maior degeneração gordurosa do subescapular e média de idade superior. As demais variáveis nao apresentaram diferenças estatisticamente significantes. CONCLUSAO: A RM de alto campo magneético sem contraste apresentou valores médios de sensibilidade, especificidade e acurácia de 70,2%, 61,9% e 67,6%, respectivamente. A sensibilidade foi superior nos radiologistas enquanto a especificidade no cirurgião de ombro. A concordância interobservador e intraobservador foi moderada / INTRODUCTION: The accuracy of magnetic resonance imaging (MRI) for the detection of subscapularis tear presents wide variation in the literature. There are few prospective studies and great methodological variation. It is believed that these tears are more difficult to diagnose than the posterosuperiores rotator cuff injuries. The subscapularis tendon has importance in the biomechanics in the shoulder and its rupture leads to functional impairment. A diagnostic tool of good accuracy is fundamental in clinical practice, influencing prognosis and surgical planning. The aim of this study was to evaluate the validity of preoperative MRI in the identification of the subscapularis tears, comparing the imaging findings with the intraoperative data of arthroscopic surgery. As a secondary objective, we evaluated the reliability of the method through interobserver and intraobserver agreement. METHODS: We performed a diagnostic accuracy study comparing MRI findings (index test) with those of arthroscopy (reference test), in a prospective cohort. We included patients submitted to arthroscopy for the treatment of rotator cuff tears that had undergone high magnetic field MRI without using contrast. Cases of previous surgical manipulation in the shoulder, exams with moving artifacts, indication for open surgery and interval between MRI and surgical procedure of more than one year were excluded. The images were evaluated by a shoulder surgeon and two musculoskeletal radiologists, independently and blinded to the results of arthroscopy, being reassessed after 3 months by the surgeon. We calculated the validity (sensitivity, specificity, positive predictive value, negative predictive value and accuracy) and reliability (inter- and intraobserver agreement) of MR in detecting subscapularis tears. RESULTS: We evaluated 200 shoulders. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% transfixing). The shoulder surgeon showed sensitivity from 51.1 to 59.0% and specificity from 91.7% to 94.4%. The radiologists, 83.5 to 87.1% of sensitivity and 41 to 45.9% of specificity. Accuracy ranged from 60.5 to 73.0%. The mean values of sensitivity, specificity and accuracy were 70.2%, 61.9% and 67.6%, respectively. Interobserver agreement was moderate for the detection of subscapular tears (kappa coefficient 0.463, 95% CI 0.383-0.534, p < 0.001), as well as intraobserver agreement (kappa coefficient 0.546, 95% CI 0.430-0.662, p < 0.001). Patients with subscapular rupture had a higher incidence of biceps rupture and instability, greater fat subscapular degeneration, and higher mean age. The other variables did not present statistically significant differences. CONCLUSION: MRI of high magnetic field without contrast showed mean values of sensitivity, specificity and accuracy of 70.2%, 61.9% and 67.6%, respectively. Sensitivity was higher in radiologists while specificity in the shoulder surgeon. Interobserver and intraobserver agreement was moderate
5

Evaluación de rupturas de manguito rotador y su relación con el índice acromial por Resonancia Magnética, Clínica Providencia de San Miguel, año 2014

Ricci Jara, Sheyla Rosa January 2016 (has links)
Determina el índice acromial en rupturas de manguito rotador evaluado por imágenes en resonancia magnética en la Clínica Providencia de San Miguel en enero - diciembre de 2014. Realiza un estudio observacional, descriptivo transversal retrospectivo utilizando las imágenes de las historias clínicas de 69 pacientes que contaban con un estudio de imágenes en resonancia magnética en la Clínica Providencia de San Miguel, Lima. Determina que el índice acromial promedio en rupturas de manguito rotador para los hombres entre las edades de 20 a 49 años es de [0.67; 0.71], entre las edades de 50 a 55 años el índice acromial promedio es [0.69; 0.73] y entre las edades de 56 a 60 años el índice promedio es de [0.67; 0.71]. El índice acromial promedio en rupturas de manguito rotador para las mujeres entre las edades de 20 a 49 años es de [0.66; 0.7], entre las edades de 50 a 55 años el índice acromial promedio es de [0.69; 0.73] y entre las edades de 51 a 60 años el grosor promedio es de [0.68; 0.70]. Concluye que el índice acromial con rupturas de manguito rotador para varones y mujeres entre las edades de 20 a 60 años es [0.69; 0.72] respectivamente.
6

Associação entre o polimorfismo genético das metaloproteinases da matriz 1 e 3 e a rotura completa do manguito rotador / Association between genetic polymorphism of matrix metalloproteinases 1 and 3 and the full-thickness rotator cuff tear

Assunção, Jorge Henrique 02 April 2019 (has links)
INTRODUÇÃO: Na patogênese da rotura do manguito rotador, diminuição da síntese e aumento da degradação das fibras colágenas são encontradas, associadas ao aumento da atividade das metaloproteinases da matriz 1 e 3 (MMP-1 e MMP-3). Há evidências que fatores genéticos estão envolvidos na produção das metaloproteinases e na etiologia da rotura do manguito rotador. O objetivo deste estudo foi avaliar a associação entre o polimorfismo genético das MMP-1 e MMP-3 com a rotura de espessura completa do manguito rotador. Como objetivos secundários, tivemos avaliar a correlação dos haplótipos da MMP-1 e MMP-3 com a rotura de espessura completa do manguito rotador e comparar se indíviduos com rotura transfixante do manguito rotador têm maior proporção de familiares com a mesma doença, em relação aos indíviduos controles. MÉTODOS: Avaliamos 64 pacientes com rotura transfixante do manguito rotador e 64 controles assintomáticos. Foram incluídos apenas pacientes com idade inferior a 65 anos e rotura de espessura completa não traumática. A rotura ou integridade do manguito rotador foi avaliada por ressonância magnética ou ultrassonografia em todos indivíduos. Os pacientes e os controles foram pareados por idade. O ácido desoxirribonucleico (DNA) dos voluntários foi obtido a partir de células epiteliais da mucosa bucal. Os genótipos das MMP-1 e MMP-3 foram determinados utilizando as técnicas de Reação em Cadeia de Polimerase (PCR) e Polimorfismo no Comprimento de Fragmentos de Restrição (RFLP). RESULTADOS: Observamos uma presença de 77% do alelo 1G e 64% do genótipo 1G/1G no grupo controle. Os pacientes com rotura transfixante do manguito rotador apresentaram uma taxa de 48% do alelo 2G e 73% de genótipos 1G/2G ou 2G/2G (p < 0,001). Indivíduos com genótipo 1G/2G e 2G/2G tiveram maior chance de ter uma rotura do manguito rotador: razão de chances (RC) igual a 4,8 (Intervalo de confiança de 95% [IC 95%] 2,1 a 11,0) e 5,2 (IC 95% 1,8 a 14,9), respectivamente. Também observamos uma distribuição significativamente diferente nos alelos e genótipos da MMP-3 (p = 0,045, p = 0,021, respectivamente) entre os casos e controles. Indivíduos com genótipo 5A/5A tiveram maior chance de apresentarem uma rotura do manguito rotador (RC 5,5; IC 95% 1,4 a 20,9). Indíviduos com haplótipo 2G/5A tiveram maior possibilidade de ter uma rotura do manguito rotador, este haplótipo foi encontrado em 42 de 64 pacientes (66%) e em 17 de 64 controles (27%), com razão de chances de 5,3 (IC 95% 2,5 a 11,3). Pacientes com rotura do manguito rotador relataram, em maior número (19 de 64 pacientes, 30%), a existência de familiares que realizaram tratamento para rotura do manguito rotador em relação aos pacientes controles (quatro de 64 pacientes, 6%; p = 0,001). CONCLUSÃO: O polimorfismo genético das MMP-1 e MMP-3 foi associado à rotura do manguito rotador / INTRODUCTION: In the pathogenesis of rotator cuff tear, decreased synthesis and increased degradation of collagen fibers are found, associated with an increase in activity of matrix metalloproteinases 1 and 3 (MMP-1 and MMP-3). There is evidence that genetic factors may be involved in metalloproteinase production and the etiology of rotator cuff tear. The aim of this study was to evaluate the association between the genetic polymorphism of MMP-1 and MMP-3 and full-thickness rotator cuff tear. As secondary aims, we measured the correlation of MMP-1 and MMP-3 haplotypes with full-thickness rotator cuff tears and compared if individuals with full-thickness rotator cuff tears have a higher proportion of relatives with the same disease than the control subjects. METHODS: We evaluated 64 patients with full-thickness rotator cuff tear and 64 asymptomatic controls. Patients aged below 65 years, with non-traumatic full thickness tears, were included. The rotator cuff tear or integrity was evaluated by magnetic resonance or ultrasound in all individuals. The patients and controls were paired by age. The deoxyribonucleic acid (DNA) of the volunteers was obtained from oral mucosa epithelial cells. MMP-1 and MMP-3 genotypes were determined using the Polimerase Chain Reaction (PCR) and Restriction Fragment Length Polymorphism (RFLP) assays. RESULTS: We observed a 77% presence of allele 1G and 64% of genotypes 1G/1G in the control group. The patients with full-thickness rotator cuff tear presented 48% of allele 2G and 73% of genotypes 1G/2G or 2G/2G (p < 0.001). Individuals with genotypes 1G/2G and 2G/2G were more likely to have a rotator cuff tear: odds ratio equal to 4.8 (95% confidence interval [95% CI] 2.1 to 11.0) and 5.2 (95% CI 1.8 to 14.9), respectively. We also observed a significantly different distribution in the alleles and genotypes of MMP-3 (p = 0.045, p = 0.021, respectively) among the cases and controls. Individuals with the 5A/5A genotype were more likely to have a rotator cuff tear (OR 5.5; 95% CI 1.4 to 20.9). Individuals with the haplotype 2G/5A were more likely to have rotator cuff tears develop, this haplotype was found in 42 of 64 patients (66%) and in 17 of 64 controls (27%) with odds ratio 5.3 (95% CI 2.5 to 11.3). Patients with rotator cuff tears reported, in higher number (19 of 64 patients, 30%), the existence of relatives who previously had treatment for rotator cuff tears compared to control patients (four of 64 patients, 6%; p = 0,001). CONCLUSION: The genetic polymorphism of MMP-1 and MMP-3 was associated with rotator cuff tear
7

Projeto e desenvolvimento de um aparelho para avaliar a força muscular isométrica dos rotatores do ombro. / Project and development of a machine to evaluate the isometric muscular strenght of the rotator muscles of the shoulder.

Souza, Patrícia de Moura 26 June 2003 (has links)
Os músculos do manguito rotador são os responsáveis pelo movimento de rotação do ombro e representam sítio freqüente de processos patológicos.O desequilíbrio de forças do manguito rotador pode desencadear patologias distintas do ombro ou ser resultado destas. A quantificação da força muscular do manguito rotador com dados precisos, somente é possível com aparelhos de alto custo, longe do alcance da maioria dos profissionais envolvidos com o problema em nosso país. No presente estudo, um aparelho relativamente simples e de baixo custo, capaz de mensurar com precisão a força muscular isométrica de rotação interna e rotação externa do ombro, foi projetado e construído com materiais de fácil obtenção e preço acessível. Ele consiste basicamente de uma plataforma de medição do torque de rotação do ombro acoplada a uma cadeira e adaptável para avaliação bilateral. O aparelho foi projetado para que o indivíduo permaneça sentado durante o teste, com cotovelo fletido a 90 graus e o antebraço apoiado sobre uma superfície plana. Um torquímetro, devidamente calibrado, foi fixado na porção inferior da plataforma, no ponto correspondente ao centro de rotação do ombro. A mudança no comprimento do braço de alavanca foi permitida pela variação na posição de um manípulo para apoio da mão durante os esforços de rotação interna e de rotação externa do ombro. Variações no comprimento do braço de alavanca e na altura da plataforma foram projetadas para adaptarem-se aos braços e antebraços dos indivíduos. O aparelho foi testado em 20 indivíduos saudáveis e demonstrou ser completamente versátil para uso em diversas condições e confiável na produção de informações sobre o torque dos músculos rotadores do ombro. / The rotator cuff muscles are responsible for the rotation movements of the shoulder and frequent site of pathological processes. Rotator cuff muscle power imbalance may unchain or result from distinct shoulder diseases. To date precise quantification of rotator cuff muscle power is only possible with the use of expensive machines, far from the reach of most of the professionals involved with the problem in our country. In the present investigation, a relatively simple and low cost device, able to precisely measuring isometric internal and external rotator muscle power, was developed and built with easily obtainable and low cost materials. It consists basically of a platform for measuring the rotational torque of the shoulder adaptable to both sides of a chair for bilateral evaluation. It was designed for the individual to remain seated while in test, the elbow flexed at 90o and the forearm rested on a flat surface. A properly calibrated torquimeter was adapted to the bottom side of the platform in a point corresponding to the shoulder’s center of rotation. The moving lever was provided with a handle to be grasped by the individual while doing internal or external efforts with the shoulder. Both platform height and moving lever were made adaptable to individual arm and forearm lengths. The device was tested with 20 healthy individuals and demonstrated to be quite versatile for use in many different conditions and reliable in providing information on the torque of the rotator muscle of the shoulder.
8

Avaliação do controle postural antecipatório em adultos com queixa de dor no ombro / Evaluation of Anticipatory Postural Control in Adults with Complaints of Shoulder Pain

Gasparin, Juliana Thomé 18 September 2018 (has links)
Os mecanismos antecipatórios durante as tarefas de alcance são de extrema importância para o equilíbrio corporal e para facilitação da execução do movimento. Há evidências na literatura que a dor crônica é capaz de influenciar na organização funcional do córtex e alterar os ajustes posturais antecipatórios, mas, até o presente conhecimento, não existe nenhum estudo que investigou estes mecanismos posturais em indivíduos com dor crônica no ombro. Por este motivo, o objetivo principal do presente estudo foi analisar os ajustes posturais antecipatórios em uma tarefa de alcance funcional em indivíduos com dor no ombro comparados a indivíduos sem dor. Participaram do estudo 20 sujeitos, sendo 9 no grupo com dor e 11 no grupo sem dor. Dados de eletromiografia dos músculos de tronco e membro inferior direito e dados de plataforma de força foram coletados durante uma tarefa de alcance funcional realizada em diferentes velocidades (rápida e normal) e alturas (menor que 90°, igual a 90° e maior que 90°). O grupo com dor apresentou menor amplitude e velocidade de deslocamento do centro de pressão, atraso no recrutamento antecipatório do músculo tibial anterior, alteração da sinergia muscular de membro inferior e tronco, atraso no tempo de resposta, maior tempo de execução do movimento e menor variabilidade do movimento. Não houve correlação entre a intensidade da dor e as alterações de comportamento motor. Os resultados mostram que indivíduos com dor no ombro apresentam falha no ajuste postural antecipatório durante uma tarefa de alcance funcional quando comparados com indivíduos sem dor / Anticipatory mechanisms during reaching tasks are extremely important for body balance and for facilitating movement execution. There is evidence in the literature that chronic pain can influence the functional organization of the cortex and alterate the anticipatory postural adjustments, but to the present knowledge, there is no study investigating of these postural mechanisms in individuals with chronic shoulder pain. For this reason, the main objective of this study is to analyze the anticipatory postural adjustments in a task of functional reach in individuals with shoulder pain compared to individuals without pain. Twenty people participated in the study, 9 in the pain group and 11 in the painless group. Electromyography data of the right trunk and lower limb muscles and force platform data were collected during a functional range task performed at different velocities (fast and normal) and heights (less than 90°, equal to 90° and greater than 90°). The pain group showed lower amplitude and pressure center displacement velocity, delayed anticipatory recruitment of the anterior tibial muscle, altered lower limb and trunk muscle synergism, delayed response time, longer execution time and less movement variability. There was no correlation between pain intensity and changes in motor behavior. The results show that individuals with shoulder pain present failure in anticipatory postural adjustment during a task of functional range when compared to individuals without pain
9

Comparación entre dos tipos de tratamiento kinésico en el síndrome de pinzamiento de manguito rotador: Instituto Traumatológico de Santiago.

Pino Tapia, Gonzalo, Selman Muñoz, Níkolas January 2006 (has links)
En un estudio descriptivo prospectivo, 22 pacientes con Síndrome de Pinzamiento de Manguito Rotador, ya sea con pinzamiento o con tendinitis de manguito rotador, divididos aleatoriamente en 2 grupos de igual número de integrantes fueron sometidos a un protocolo de tratamiento kinésico ambulatorio y a un tratamiento kinésico pauta de ejercicios, respectivamente. El estudio se llevó a cabo en un período promedio de 5 semanas, con un intervalo de duración de 4 a 6 semanas, con una evaluación al inicio y otra al final de los tratamientos respectivos, hecha por un evaluador independiente. Los resultados funcionales se objetivaron mediante el uso del Score de Constant y para el análisis estadístico se usó el test de Wilcoxon. Dentro de los principales resultados ambos grupos mejoraron sus estados basales patológicos de manera estadísticamente significativa. Además existió una notoria mejoría del grupo que recibió el protocolo de tratamiento kinésico ambulatorio por sobre el otro grupo con respecto a sus estados funcionales. Se cree que el protocolo propuesto resultó efectivo debido a la presencia constante del kinesiólogo como también a la calidad del tratamiento, sin embargo se recomiendan estudios a largo plazo que corroboren dichos resultados.
10

Projeto e desenvolvimento de um aparelho para avaliar a força muscular isométrica dos rotatores do ombro. / Project and development of a machine to evaluate the isometric muscular strenght of the rotator muscles of the shoulder.

Patrícia de Moura Souza 26 June 2003 (has links)
Os músculos do manguito rotador são os responsáveis pelo movimento de rotação do ombro e representam sítio freqüente de processos patológicos.O desequilíbrio de forças do manguito rotador pode desencadear patologias distintas do ombro ou ser resultado destas. A quantificação da força muscular do manguito rotador com dados precisos, somente é possível com aparelhos de alto custo, longe do alcance da maioria dos profissionais envolvidos com o problema em nosso país. No presente estudo, um aparelho relativamente simples e de baixo custo, capaz de mensurar com precisão a força muscular isométrica de rotação interna e rotação externa do ombro, foi projetado e construído com materiais de fácil obtenção e preço acessível. Ele consiste basicamente de uma plataforma de medição do torque de rotação do ombro acoplada a uma cadeira e adaptável para avaliação bilateral. O aparelho foi projetado para que o indivíduo permaneça sentado durante o teste, com cotovelo fletido a 90 graus e o antebraço apoiado sobre uma superfície plana. Um torquímetro, devidamente calibrado, foi fixado na porção inferior da plataforma, no ponto correspondente ao centro de rotação do ombro. A mudança no comprimento do braço de alavanca foi permitida pela variação na posição de um manípulo para apoio da mão durante os esforços de rotação interna e de rotação externa do ombro. Variações no comprimento do braço de alavanca e na altura da plataforma foram projetadas para adaptarem-se aos braços e antebraços dos indivíduos. O aparelho foi testado em 20 indivíduos saudáveis e demonstrou ser completamente versátil para uso em diversas condições e confiável na produção de informações sobre o torque dos músculos rotadores do ombro. / The rotator cuff muscles are responsible for the rotation movements of the shoulder and frequent site of pathological processes. Rotator cuff muscle power imbalance may unchain or result from distinct shoulder diseases. To date precise quantification of rotator cuff muscle power is only possible with the use of expensive machines, far from the reach of most of the professionals involved with the problem in our country. In the present investigation, a relatively simple and low cost device, able to precisely measuring isometric internal and external rotator muscle power, was developed and built with easily obtainable and low cost materials. It consists basically of a platform for measuring the rotational torque of the shoulder adaptable to both sides of a chair for bilateral evaluation. It was designed for the individual to remain seated while in test, the elbow flexed at 90o and the forearm rested on a flat surface. A properly calibrated torquimeter was adapted to the bottom side of the platform in a point corresponding to the shoulder’s center of rotation. The moving lever was provided with a handle to be grasped by the individual while doing internal or external efforts with the shoulder. Both platform height and moving lever were made adaptable to individual arm and forearm lengths. The device was tested with 20 healthy individuals and demonstrated to be quite versatile for use in many different conditions and reliable in providing information on the torque of the rotator muscle of the shoulder.

Page generated in 0.0737 seconds