Spelling suggestions: "subject:"mechanical resonanter"" "subject:"mechanical resonant""
1 |
Direct Measurement of the Spectral Distribution of Thermal NoiseSlagmolen, Bram Johannes Jozef, BRAM.SLAGMOLEN@ANU.EDU.AU January 2005 (has links)
This thesis investigates the direct measurement of the thermal noise spectral distribution.
Long base line gravitational wave detectors, being commissioned around
the world, are limited in sensitivity in the intermediate frequencies by the thermal
noise. These detectors are utilising suspended test mirrors for the detection of gravitational
waves by measuring their relative displacement. One of the fundamental
noise sources in these detectors is the thermally induced displacement of the suspension
onto and within the mirrors. This thermally induced motion of the test mirrors
limits the displacement sensitivity of the gravitational wave detectors. Knowledge
of the spectral behavior of thermal noise over a wide frequency range will improve
predictions and understanding of the behavior of the suspension and test mirrors.¶
In this thesis the direct measurement of the thermal noise spectral distribution
of a mechanical flexure resonator is described. The mechanical flexure resonator is
an unidirectional ’wobbly table’ made from copper-beryllium, which hinges around
four thin flexures 15 mm wide, 1 mm high and ~116 µm thick. The mechanical
flexure resonator has a resonant frequency of 192 Hz, with a quality factor of ~3000.¶
The thermal noise induced displacement of the mechanical flexure resonator was
measured using an optical cavity. The end mirror of a two mirror optical cavity was
mounted on the mechanical flexure resonator. A laser was made resonant with the
test cavity by use of a locking control system. Thermal noise induced displacement
moved the test cavity away from resonance. By measuring the error-signal in the
control system, the equivalent thermal noise displacement was obtained.¶
The thermal noise induced displacement of the mechanical flexure resonator was
predicted to be in the order of 10^(−12) to 10^(−17) m/sqrtHz over a frequency range of
10 Hz to 10 kHz. All other external noise sources needed to be suppressed to below
this level. A major noise source was the laser frequency fluctuations. When the
test cavity was locked to the laser, the laser frequency fluctuations dominated the
read out signal. To suppress the frequency fluctuations, the laser was locked to a
rigid long optical reference cavity. This allowed the frequency fluctuations to be
suppressed to below the equivalent thermal noise displacement of the test cavity
over the frequency range of interest.¶
Acoustic noise was suppressed by placing the whole experiment inside a vacuum
chamber, and evacuating the air inside the chamber down to a pressure level of
10^(−4) mbar. A seismic vibration isolation system was used to suppress the seismic
noise in the laboratory to below 10^(−14) m/sqrtHz at frequencies above 4 Hz.¶
With the experimental set up, the thermal noise displacement of the mechanical
flexure resonator has been measured. Due to the degradation of the isolator performance,
measurement of the thermal noise behavior over a wide frequency range of
the mechanical flexure resonator was unsuccessful. By using an analytical curve fitting
routine around the fundamental and first order resonant modes of the resonator,
a loss factor of (3.5 ± 1.5 − 3.7 ± 1.5) × 10^(−4) for the copper-beryllium mechanical
flexure resonator was obtained and structural damping was inferred.
|
Page generated in 0.0807 seconds