• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 14
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 163
  • 51
  • 42
  • 40
  • 39
  • 39
  • 26
  • 25
  • 23
  • 20
  • 19
  • 19
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo e implementação de um carregador de baterias com uma técnica de avaliação de sua vida útil

Lazzarin, Telles Brunelli January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2013-07-16T03:11:43Z (GMT). No. of bitstreams: 1 232187.pdf: 3430336 bytes, checksum: 63ba30cc83187b6e9204631a13b78011 (MD5) / O trabalho proposto nesta dissertação tem como finalidade estudar e implementar um carregador diferenciado para baterias de chumbo-ácido e um sistema de avaliação on-line do estado da vida útil das baterias. A estrutura de controle do carregador é projetada para realizar uma curva de carga que garanta a equalização das cargas de todas as baterias. Também é analisada a compensação nas referências de tensão devido a variações na temperatura. O objetivo da proposta de controle é otimizar a vida útil, evitar problemas de carga insuficiente, de sobrecarga e de sulfatação nas baterias. O trabalho também estuda o aumento da corrente de carga com a ligação de carregadores em paralelo. O sistema proposto para a avaliação da vida útil das baterias utiliza o método de medição da impedância alternada, no qual relaciona o aumento da impedância com o fim da vida útil da bateria. A implementação do sistema inclui uma fonte de corrente, uma placa de aquisição e uma interface com o usuário. A avaliação das condições do banco de baterias tem o objetivo de aumentar a confiabilidade dos sistemas de UPS (Uninterrupted Power Supply). The present work aims at studying and implementing a differentiated lead-acid battery charger and an online evaluation system for the state (conditions) of useful life of batteries. The charger control structure is designed to produce a charge curve that guarantees the charge equalization of all batteries. An analysis of the compensation in the voltage references due to temperature variations is also carried out. The goal of the control proposal is to optimize the useful life of batteries and avoid problems derived from insufficient charge, overcharge and sulfation. This work also investigates the increase in load current with the coupling of chargers in parallel. The proposed battery evaluation system uses the alternate impedance measurement method, which associates the increase in impedance to the useful life of the battery. The system implementation includes a current source, a data acquisition card, and a user interface. The evaluation of the battery bank conditions aims at increasing the UPS (Uninterrupted Power Supply) system reliability.
12

Desenvolvimento de uma bancada gravimétrica automática para calibração de medidores de vazão com diferentes fluidos

Parra Sejas, Miriam Zareth January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Automação e Sistemas, Florianópolis, 2016. / Made available in DSpace on 2017-06-27T04:07:12Z (GMT). No. of bitstreams: 1 346009.pdf: 9344378 bytes, checksum: 3270eb4a53087a9a2c7c72a9e4f53a57 (MD5) Previous issue date: 2016 / Atualmente nos processos de produção tornou-se muito delicado o tema dos erros na medição de vazão, já que esses erros representam geralmente perdas econômicas para as empresas. Com a finalidade de minimizar esses erros deve-se ter o cuidado de que os dados de medição dos instrumentos se encontrem dentro das especificações de incerteza de medição e para isso é importante realizar calibrações periódicas. Uma forma de realizar a calibração nos medidores de vazão é através das comparações mássicas (método gravimétrico), já que a massa é uma propriedade fundamental da matéria e seu valor não é alterado sob diferentes condições de temperatura e pressão, o que faz com que o processo de calibração de vazões mássicas ocorra de forma mais fácil. Em vista disso, o presente trabalho apresenta a descrição de dois sistemas de calibração implementados, ambos para baixas vazões de líquidos, de até 6 kg/h, e baseados no método gravimétrico. Um primeiro protótipo de baixo custo foi construído para identificar os pontos mais críticos e permitir a construção mais acertada de um segundo protótipo, a versão melhorada do primeiro. Para ambos os protótipos, foi usado um medidor de vazão tipo Coriolis como transdutor em avaliação, que serviu como padrão para avaliação das bancadas. O primeiro protótipo apresentou desvios da ordem de 2% quando seus resultados foram comparados com as indicações do medidor Coriolis. No segundo protótipo, foram corrigidos os pontos fracos do primeiro protótipo, e com isso foi possível diminuir 42 vezes o erro do primeiro protótipo em relação ao transdutor empregado como padrão, atingindo valores da ordem de 0,03%. A construção do segundo protótipo foi realizada de forma a permitir sua operação com diferentes fluidos de trabalho, sendo assegurada através de projeto a compatibilidade com água, diferentes tipos de óleo mineral e gasolina. Uma avaliação da incerteza de medição dos ensaios realizados com o segundo protótipo indicou uma incerteza expandida de ±0,002 kg/min, sendo esse valor inferior à incerteza encontrada para o medidor Coriolis, o tipo com melhores especificações metrológicas do mercado.<br> / Abstract : Currently in production processes, flow measurement errors have become a serious issue, these errors generally represent economic losses. In order to minimize them, one must it ensure that the measurement data of the instruments are within the specifications of measurement uncertainty and, for this purpose, it is important to perform periodic calibrations. One way to perform flow meter calibrations is through mass comparisons (gravimetric method), since the mass is a fundamental property of matter and its value is not changed under different conditions of temperature and pressure, which allows the mass flow calibration process to occur more easily. In view of this, the present work presents the description of two calibration systems implemented for operating with low flow rates of liquids, up to 6 kg/h, and based on the gravimetric method. A first prototype of low cost was built to identify the most critical points and, thus, support the development of a second prototype, an improved version of the first. For both prototypes, a Coriolis flowmeter was used in the position of the transducer to be evaluated, but it, in fact, served as a standard for evaluating the responses of both systems. The first prototype presented errors around 2% when its measurements are compared with the indications of the Coriolis meter. The second prototype corrected the main weaknesses of the first prototype, achieving errors 42 times lower than the ones presented by the first prototype (absolute errors are of approximately 0.03%). The second prototype was designed to allow its operation with different working fluids, being ensured through project compatibility with water, different types of mineral oil, and gasoline. An evaluation of the measurement uncertainty of the second prototype indicated an expanded measurement uncertainty of ±0.002 kg/min, which is lower than the uncertainty value found for the Coriolis meter, the flowmeter principle with better metrological specifications in the market.
13

Desenvolvimento e Implementação de um Sistema de Monitoramento em Tempo Real da Tensão da Rede com Acesso Remoto

COLNAGO, G. P. 05 October 2009 (has links)
Made available in DSpace on 2016-08-29T15:32:34Z (GMT). No. of bitstreams: 1 tese_2867_DissertacaoMestradoGuilhermePiazentiniColnago.pdf: 5714672 bytes, checksum: 546066abb4da930c23054caf4381781d (MD5) Previous issue date: 2009-10-05 / No Brasil, até pouco tempo atrás, a qualidade da energia elétrica estava relacionada, basicamente, com interrupções do fornecimento de energia e a certas cargas &#147;especiais&#148; da indústria. Porém, nos últimos anos, sob a direção da agência reguladora do setor, a ANEEL (Agência Nacional de Energia Elétrica), juntamente com especialistas, a área de qualidade da energia elétrica passou a receber uma atenção significativa, sendo legislada e adquirindo suas regulamentações iniciais. A área de Qualidade da Energia Elétrica passou, então, a formalmente existir e abranger um conjunto maior de fenômenos e eventos da rede elétrica. Em função dessa recente regulamentação, este trabalho apresenta o projeto de um medidor da qualidade da energia elétrica. Um dos focos do medidor é ser de baixo custo, tornando-o viável para o uso em grande escala. Este medidor é um sistema eletrônico que processa digitalmente os sinais de tensão da rede elétrica, extraindo os dados relacionados à qualidade da energia elétrica; tais dados são armazenados localmente e, posteriormente, acessados remotamente e enviados para um banco de dados, de forma que possam ser analisados.
14

Análise Experimental e Avaliação das Incertezas em Medição de Líquidos Com Referência Tipo Ball-prover

LAVEZZO, L. F. Q. 09 April 2010 (has links)
Made available in DSpace on 2016-08-29T15:32:50Z (GMT). No. of bitstreams: 1 tese_3824_LAVEZZO, Luis. DISSERTAÇÃO DE MESTRADO.2010.pdf: 2565990 bytes, checksum: 8f8dc2296308d294e6a3388373c7da8d (MD5) Previous issue date: 2010-04-09 / Este estudo se dedica à medição referencial de vazão de líquidos com o propósito de se lidar com as características específicas do funcionamento de um medidor, que tem suma importância nos interesses envolvendo transações comerciais na indústria de petróleo. O processo de medição de vazão envolve diversas variáveis que contribuem para a incerteza do real valor que se propõe medir. Estas variáveis vão desde características construtivas do medidor, propriedades do fluido a ser medido, das condições ambientais e perícia do operador. A proposta deste estudo é apresentar um projeto de protótipo laboratorial de medidor de referência tipo ball prover, avaliar experimentalmente seu desempenho e buscar se alinhar com os requisitos estabelecidos pelas normas. As incertezas inerentes à medição e sua contribuição em diferentes trechos será avaliada através de comparações com um medidor do tipo turbina, calibrado pelo fabricante. Palavras-chave: Medidores de fluxo, calibração, incerteza, provador em linha.
15

Modelamento físico e matemático do fluxo no Interior de um molde de lingotamento contínuo de Beam Blank alimentado com duas válvulas submersas tubulares.

Peixoto, Johne Jesus Mol January 2016 (has links)
Programa de Pós-Graduação em Engenharia de Materiais. Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-04-28T19:51:39Z No. of bitstreams: 1 DISSERTAÇÃO_ModelamentoFísicoMatemático.pdf: 2408669 bytes, checksum: 319497cc9692b0eef0085742a8e9f0ec (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-04-29T13:52:26Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_ModelamentoFísicoMatemático.pdf: 2408669 bytes, checksum: 319497cc9692b0eef0085742a8e9f0ec (MD5) / Made available in DSpace on 2016-04-29T13:52:26Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_ModelamentoFísicoMatemático.pdf: 2408669 bytes, checksum: 319497cc9692b0eef0085742a8e9f0ec (MD5) Previous issue date: 2016 / O controle do fluxo de aço é de extrema importância para o processo de lingotamento contínuo de beam blank, pois influencia a taxa de flotação de inclusões não-metálicas; os mecanismos de formação e crescimento da casca solidificada e a eficiência de lubrificação das paredes do molde. Um fluxo inadequado de aço no interior do molde pode gerar defeitos que resultam no sucateamento do lingote ou redução do ritmo de produção. Para elucidar os parâmetros que interferem no fluxo de aço, foram realizados modelamentos físico e matemático do fluxo de fluido no interior de um molde de lingotamento contínuo de beam blank alimentado com duas válvulas tubulares, avaliando a influência da velocidade de lingotamento, da profundidade de imersão e do diâmetro das válvulas submersas. Para o modelamento matemático utilizou-se o software CFX 15.0. A técnica PIV foi utilizada para obter informações quantitativas e qualitativas do fluxo. Os resultados das simulações matemáticas mostraram boa concordância com os resultados do modelamento físico, portanto, o modelo matemático foi capaz de descrever as características do fluxo no interior do molde de lingotamento contínuo de beam blank. A análise do perfil de velocidades do líquido, no interior do molde de beam blank, revelou a existência de seis vórtices, dois na região da alma e dois em cada flange do molde, sendo que este padrão de fluxo (quantidade e posição dos vórtices) não sofreu modificações quanto às variáveis analisadas. O jato de líquido proveniente da SEN se espalha mais rapidamente para a ponta dos flanges e lentamente pela alma, o que pode acarretar na solidificação irregular da pele ao longo da seção transversal. O aumento da vazão de fluido implica em aumento da profundidade de penetração do jato de líquido, sendo que este excede o comprimento real do molde (0,8m) para a vazão de 150l/min (equivalente à velocidade de lingotamento de 1,2m/min). Para uma SEN com diâmetro interno de 34,6mm, observou-se que o menisco é estável, isto é, possui baixa intensidade de flutuação (aprox. 0,22mm) e esta não é afetada significativamente pela variação da velocidade de lingotamento e da profundidade de imersão da SEN. A partir destes resultados, sugere-se profundidade de imersão igual a 75mm e velocidade de lingotamento máxima de 1m/min. ______________________________________________________________________________________ / ABSTRACT : The steel flow control is very important to the continuous casting of beam blank, since it influences the inclusions removal, the development of solidified shell and its lubrication. Inadequate flow can generate defects that result in the scrapping of the ingot or reduced production rhythm. In this work techniques of physical and mathematical modeling have been applied in order to elucidate the influence of parameters such as casting speed, the immersion depth and SEN inner diameter on the fluid flow inside a beam blank continuous casting mold fed with two straight through tubular type nozzles. The CFX 15.0 software was used for the mathematical modeling and the PIV technique was used to obtain quantitative and qualitative flow information. Results from mathematical and physical simulations were in good agreement; therefore the mathematical model was able to describe the flow characteristics inside the mold. The velocity profile analysis revealed the existence of six vortices in the mold, two at the web region and two at each flange, and this overall flow pattern (number and location of the vortices) does not change with process variables. The outcoming SEN fluid jet quickly spreads itself to the flange edge and slowly to the web. This can lead to irregular shell solidification over the cross section. Increasing the fluid flow rate results in an increasing jet penetration depth. For flow rate of 150L/min (equivalent to the casting speed of 1.2m/min) the latter can exceed the actual length of the mold (0.8m). For a SEN with inner diameter of 34.6mm, it was observed that the meniscus is stable, that is, it shows a low intensity of fluctuation (approx. 0.22mm); this intensity of oscillation is not significantly affected by either casting speed or SEN immersion depth. From these results, it is suggested an immersion depth equal to 75mm and a maximum casting speed of 1 m/min.
16

Estudo do escoamento multifásico em medidores de vazão do tipo pressão diferencial

Paladino, Emilio Ernesto January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica / Made available in DSpace on 2013-07-15T23:48:33Z (GMT). No. of bitstreams: 1 226893.pdf: 15452742 bytes, checksum: 0c52163c3c601362dc6d8638eb698cd0 (MD5) / Medidores de vazão baseados em pressão diferencial são comumente utilizados em sistemas de transporte de petróleo e gás natural. A precisão destes sistemas é de fundamental importância em aplicações como gerenciamento de reservatórios, sistemas de detecção de vazamentos, controle de processos de produção e medição fiscal. E aplicações para escoamentos monofásicos, tanto a estrutura do escoamento quanto as relações entre pressão e vazão, nas constrições utilizadas para medição, são conhecidas. Entretanto, em escoamentos multifásicos, estas relações são mais complexas devido à aparição de novos parâmetros de escoamento tais como velocidades relativas, fração de fase, etc.. Este trabalho propõe um estudo teórico e experimental de escoamentos multifásicos dispersos em medidores de vazão baseados em pressão diferencial. Para o estudo teórico, propõe-se a utilização do modelo de dois fluídos cuja formulação é baseada numa abordagem Euleriana da mistura bifásica. Algumas modificações nos modelos comumente encontrados na literatura são propostas, principalmente para os termos de transferência interfacial cuja correta modelagem é de fundamental relevância na
17

Frequência e duração de violações de limites de tensão em sistemas de distribuição de energia elétrica

Costa, Ederson Silveira January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós -Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-19T06:35:44Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T23:12:45Z : No. of bitstreams: 1 182197.pdf: 4014834 bytes, checksum: ff1d47f7d606230c9e11d74a03c3f303 (MD5) / Este trabalho aborda o problema da qualidade de serviço nos sistemas de distribuição de energia elétrica. Objetiva o cálculo da freqüência e duração das violações de tensão, além da aplicação de uma penalidade às empresas distribuidoras de energia elétrica, quando do não cumprimento dos índices de tensão exigidos pelo órgão regulador. Para tanto utiliza-se um método de conversão consumo - demanda que permite a obtenção das curvas diárias de carga dos transformadores pertencentes ao alimentador sob análise. A partir destas curvas pode-se executar um programa de fluxo de potência para cada hora do dia, obtendo-se assim o perfil da tensão em cada ponto de carga (transformador) do alimentador nas vinte e quatro horas de estudo. De posse destes dados, pode-se verificar a intensidade, freqüência e duração das violações de tensão ao longo do dia. Caso sejam verificadas estas violações, aplica-se então uma penalidade baseada no tempo e na intensidade das mesmas. A proposta apresentada mostra-se eficiente, pois apresenta de forma clara às empresas as vantagens de se investir em melhorias em suas redes de distribuição, quando comparado com os recursos despendidos no pagamento das multas referentes às penalizações. Propõe-se que o valor da multa a ser pago pela empresa seja ressarcido aos clientes diretamente afetados pela falta de qualidade, demostrando-se ser uma proposta socialmente correta.
18

Gerenciador de consumo e demanda de energia elétrica em baixa tensão /

Cardoso, Ademir Donisete. January 2006 (has links)
Resumo: Este trabalho apresenta o desenvolvimento de um sistema gerenciador de energia elétrica, do ponto de vista de sua concepção e do desenvolvimento de um protótipo que deve ser adaptado a medidores eletromecânicos de indução tipo Ferraris para leitura automática do consumo de energia para fins de faturamento. Incialmente se apresenta na fundamentação teórica os assuntos importantes para o desenvolvimento do trabalho. Na sequência o trabalho apresenta a concepção do sistema desenvolvido ilustrando as alternativas e opções técnicas adotadas. Em seguida se apresenta como o sistema desenvolvido pode ser utilizado pelas concessionárias de energia para implementar um esquema de tarifa diferenciada para seus consumidores. Uma análise de diferentes cenários de implantação é feita. O objetivo principal para a adaptação de medidores eletromecânicos é permitir um certo nível da automatização, a baixo custo, da leitura de unidades consumidoras do grupo B. O medidor adaptado envia um sinal para um concentrador através da própria rede de distribuição. A partir desse concentrador, os dados podem ser coletados ou retransmitidos por diferentes tecnologias exixtentes, no protótipo implementado os dados são enviados usando a rede de telefonica móvel GSM/GPRS. / Abstract: This work presents the development of an electric energy managemnt system, with the point of view of its conception and of the development of a prototype that must be adapted to Ferraris induction electromechanical measures for automatic reading of the consumption of energy for incoicing ends. Initially we present the important subjects for the development of the work. Then we present the conception of developed system illustrating the alternatives and the techniques adopted. After that, it is presented as the developed system can be used by the energy concessionaires to implement a project of differentiated tariff for its consumers. Analyses of different implantation sceneries are made. The main objective for the adaptation of electromechanical measures is to allow a certain level of the automatization, at low cost, of the reading of units consumers of group B. The measurer sends a signal for a concentrator through the proper net of distribution. From this concentrator, the data can be collected or be relyed by different exiting technologies. In the implemented prototype the data are sent using the GSM/GPRS technology. / Orientador: José Celso Freire Junior / Coorientador: Agnelo Marotta Cassula / Banca: Luis Guilherme Barbosa Rolim / Banca: Edson da Costa Bortoni / Mestre
19

Estudo do reflexo inibitorio retoanal em multiparas, na zona de alta pressão com cateter radial

Leal, Vilmar Moura 29 January 2003 (has links)
Orientador: Claudio Saddy Rodrigues Coy / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T16:26:48Z (GMT). No. of bitstreams: 1 Leal_VilmarMoura_M.pdf: 1606636 bytes, checksum: 7b12d0641f97608e38b55b8cc93da306 (MD5) Previous issue date: 2003 / Resumo: A fisiologia da evacuação e a fisiopatologia dos distúrbios evacuatórios ainda hoje não são bem compreendidas. A ocorrência destes distúrbios vem aumentando progressivamente, implica em limitações, compromete a qualidade de vida e tem custos significativos. A incontinência fecal acomete cerca de 2% da população, com predomínio em mulheres e que tenham tido partos normais. Com relação à constipação, em 30 a 50% dos casos, a causa é funcional. Os testes para o estudo da fisiologia anorretal têm sido bastante utilizados, especialmente a manometria. No entanto, algumas variáveis deste exame ainda apresentam dúvidas quanto sua interpretação. Dentre estas, destaca-se o Reflexo Inibitório Retoanal (RIRA), freqüentemente descrito como presente, ausente ou inconclusivo. Apenas recentemente vem sendo realizada uma abordagem mais pormenorizada deste. Sendo a pesquisa deste reflexo comumente realizada com cateter axial e considerando a assimetria anatômica do canal anal, seu estudo na zona de mais alta pressão (ZAP) com cateter radial poderia adicionar informações não disponíveis. Objetivo: estudar os parâmetros do reflexo inibitório retoanal em multíparas, com cateter radial. No período entre 2001 e 2002, foram estudadas 36 pacientes, com quatro a seis partos vaginais, com média de idade de 40,7 (30 a 50) anos, Grupo 1 e 10 pacientes, com um a três partos vaginais, com média de idade de 38,5 (31 a 50) anos, Grupo 2. Com relação à função evacuatória do Grupo 1, 63,9% das pacientes encontravam-se assintomáticas, 33,3% apresentavam como queixa constipação e 2,8% incontinência fecal. Dentre as pacientes do Grupo 2, 50% eram assintomáticas e as demais referiam constipação. Todas as pacientes são oriundas do Hospital Getúlio Vargas ¿ Teresina - PI - Universidade Federal do Piauí (UFPI). Foram analisados na ZAP a pressão anal média de repouso (PAM) e os seguintes valores por quadrante: pressão média de repouso pré-relaxamento (PREP), porcentagem de relaxamento (%RELAX), pressão no ponto de máximo relaxamento (PRELAX), tempo de relaxamento (TRELAX) e o tempo de recuperação (TREC). Não houve diferença significante entre as médias de idades dos pacientes dos Grupos 1 e 2 (p = 0,43), assim como entre as médias da pressão anal média de repouso (p = 0,053). Os valores das médias da PREP nos quadrantes apresentaram diferença com significância estatística, no Grupo 2. A comparação dos valores desta variável entre os Grupos 1 e 2 foi estatisticamente diferente nos quadrantes com exceção do anterior. Os valores das médias de PRELAX foram mais baixos e com significância estatística no Grupo 1, a comparação entre os grupos evidenciou diferença estatisticamente significante nos quadrantes 1 e 4. Não foram evidenciadas diferenças significativas entre os valores das médias de %RELAX no Grupo 1 ou Grupo 2, assim como entre os grupos. Também não ocorreu diferença significativa com relação aos valores dos tempos de relaxamento e de recuperação nos dois grupos, assim como a comparação destas variáveis entre os grupos nos diferentes quadrantes. Os dados obtidos nesta casuística permitem concluir que: 1- a PREP nos quadrantes, tende a uma simetria nas pacientes multíparas, provavelmente decorrente de comprometimento global da função esfincteriana; 2- o Reflexo Inibitório Retoanal(RIRA), contrariamente a PREP, pode ter os parâmetros que o compõe manifestados de maneira irregular nos diferentes quadrantes na ZAP, da mesma forma, em decorrência das alterações estruturais mais prováveis nas pacientes do Grupo 1; 3- a utilização do cateter radial no estudo do Reflexo Inibitório Retoanal (RIRA) pode fornecer dados não obtidos com o cateter axial / Abstract: Physiology of evacuation and physiopathology of evacuatories disturbs still today aren¿t well understood. The occurrence of this disturbs has been rising progressively, it implies in limitation, affects the quality of life and has significant costs. Fecal incontinence occurs at about 2% of population, more in women, especially in those who had vaginal delivery history. In relation to constipation, 30 ¿ 50% of the cases, the cause is functional. Physiologies tests have been used more and more frequently, among these tests the pioneer manometry has gain more attention. Therefore same variables of this test have still doubt about its interpretation. Among this doubts there is the inhibitory recto anal reflex (RIRA), frequently described as present, absent or inconclusive. Only recently a more detailed approach of this complex phenomena has been realized. Once the research of this reflex is commonly made with axial catheter, and considering that anatomy of the anal canal is not symmetric, the study of the RIRA in the high pressure zone (HPZ), with radial catheter could add more information that were not available. Aim: to study parameters of inhibitory recto anal reflex in multiparous, with radial catheter. In the period of 2001 to 2002, 36 patients with 4 to 6 vaginal delivery were studied, with average age 40,7 (30 ¿ 50) years old, belong to Group 1 and 10 patients with 0 to 3 vaginal delivery, with average age 38,5 (31 ¿ 50) years old, belong to Group 2. In relation to evacuation function in Group 1, 63,9% of the patients were asymptomatic, 33,3% had constipation and 2,8% had fecal incontinence. Among the patients of Group 2, 50% were asymptomatic and 50% were constipated. All patients were from Hospital Getúlio Vargas ¿ Teresina ¿ PI ¿ Federal University of Piauí ¿ UFPI. This study was approved by Ethical Committee of this university. In HPZ, anal resting pressure (ARP) and the follow values for quadrant: average of resting anal pressure before relaxation (PREP), percentage of relaxation (%RELAX), pressure at the point of maximum relaxation (PRELAX), relaxation time (TRELAX) and recovery time (TREC) were analyzed. There weren't significant difference between average age of the patients in the two groups (p = 0,43) as far as average of resting anal pressure (p = 0,053). The average values of PREP among quadrants had statistics significant differences in Group 2. The comparison of the values of this variable in two groups was statistically different in the quadrants except in the anterior. The values of PRELAX average were smaller and with statistics difference in Group 1, the comparison between groups shows statistics significant differences in quadrants 1 and 4. No significant differences were observed in the values of %RELAX in Group 1 or Group 2, as far as between the groups there were. Also no differences with relaxation and recovery time among quadrants in the groups as far as between groups. The data obtained in this study permit the following conclusion: 1- PREP among quadrants tend to a lack of symmetry in multiparous patient, probably because of global involvement of sphincter function; 2- RIRA in opposition of PREP, can have its parameters manifested of irregular way among quadrants of HPZ, the same way because of structural alterations more probably in patients of Group 1; 3- Use of radial catheter in study of RIRA can produce data that can not be obtained with axial catheter / Mestrado / Medicina Interna / Mestre em Ciências Médicas
20

Desempeño del parque de medidores de agua potable de diámetro nominal 15 en la jurisdicción de Arequipa metropolitana y su relación con la gestión comercial de la Empresa de servicios de agua potable y alcantarillado de Arequipa para el año 2014.

Monje Vera, Carlos Alberto 10 June 2016 (has links)
Este trabajo de investigación denominado “Desempeño del parque de medidores de agua potable de diámetro nominal 15 en la jurisdicción de Arequipa metropolitana y su relación con la gestión comercial de la empresa de servicios de agua potable y alcantarillado de Arequipa para el año 2014” tiene como objetivo medir la influencia del desempeño del parque de medidores de agua potable de diámetro nominal 15 en la jurisdicción de Arequipa metropolitana, en la gestión comercial de la empresa de servicios de agua potable y alcantarillado. Para tal fin se ha estructurado la metodología de investigación basada en el estudio de tipo no experimental, de alcance descriptivo, desarrollando una investigación de tipo descriptivo correlacional, con diseño no experimental transeccional o transversal y el método teórico deductivo. Cómo técnica e instrumentos de recolección de datos, se utilizó una base de datos documental donde se precisa la información requerida para la realización del presente estudio. / Tesis

Page generated in 0.0438 seconds