Spelling suggestions: "subject:"membrana""
41 |
Molekulardynamische Simulationen von Sorptions- und Diffusionsvorgängen in PervaporationsmembranenSchepers, Claudia. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2001--Berlin.
|
42 |
Neuartige poröse a-Al203-Werkstoffe und- MembranenBuse, Frank. Unknown Date (has links)
Universiẗat, Diss., 2002--Münster (Westfalen). / Dateiformat: PDF.
|
43 |
Thermodynamik amphiphiler Membranen unter Verwendung molekularer ModelleHoffmann, Martin. Unknown Date (has links)
Universiẗat, Diss., 2002--Jena.
|
44 |
Analyse der Faltenbildung in Membranen aus unterschiedlichen MaterialienHornig, Jörg. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2004--Berlin.
|
45 |
Effective curvature elastic constants for membrane polymer systemsAuth, Thorsten. Unknown Date (has links) (PDF)
University, Diss., 2004--Köln.
|
46 |
Einfluss von Tenting Screws auf die bukkale Volumenstabilität nach Augmentation mit zwei verschiedenen Kollagenmembranen - ein in vitro Versuch im Schweinekiefer / Graft stability comparing two collagen membranes with and without Tenting Screws after wound closure - an in vitro study in pig jawsLux, Sophia Ellen January 2021 (has links) (PDF)
Zahnverlust geht bekannter Weise mit einem Verlust von Hart- und Weichgewebe einher. Mit der relativ neuen Tent-Pole Technik könnte der Volumenverlust durch den Wundverschluss bei Knochenaugmentation nach der GBR-Methode geringer ausfallen. In 10 Schweineunterkiefern wurden mit beiden Methoden augmentiert und mithilfe von Cerec- und DVT-Scans das Volumen vor und nach dem Wundverschluss verglichen. Dabei konnte festgestellt werden, dass bei Verwendung einer Tenting Screw signifikant weniger Volumenverlust als bei Augmentation mit der GBR-Technik resultierte. Ein zusätzlicher Vergleich von zwei Kollagenmembranen, OssixPlus und BioGide, im Hinblick auf den Widerstand gegen den Nahtverschluss zeigte im Signifikanztest keinen Vorteil der ribosekreuzvernetzten und steiferen OssixPlus Membran. Zahlreiche klinische Untersuchungen berichten im Zusammenhang mit der Tent Pole-Technik von komplikationslosem Einheilen, suffizientem Knochenaufbau und erfolgreicher Implantation. So könnte sich die Tenting Screw nach weiteren Untersuchungen im in vivo Modell zu einer eventuell ebenbürtigen Alternative zum bisherigen Goldstandard, dem Knochenblock entwickeln. Dieser stellt sich im Vergleich als technikintensivere und, gerade bei autologem Material, als für den Patienten weniger komfortable Maßnahme dar. / Tooth loss is known to be associated with a loss of hard and soft tissue. With the relatively new tent-pole technique, the loss of volume due to wound closure during bone augmentation using the GBR method could be lower. Both methods were used to augment 10 lower jaws of pigs and the volume before and after wound closure was compared using Cerec and DVT scans. It was found that the use of a tenting screw resulted in significantly less volume loss than augmentation with the GBR technique. An additional comparison of two collagen membranes, OssixPlus and BioGide, with regard to the resistance to suture closure showed no advantage of the ribose cross-linked and stiffer OssixPlus membrane in the significance test. Numerous clinical studies report in connection with the tent pole technique of uncomplicated healing, sufficient bone formation and successful implantation. After further investigations in the in vivo model, the tenting screw could develop into a possibly equal alternative to the previous gold standard, the bone block. In comparison, this is a more technology-intensive and, especially with autologous material, less comfortable for patients.
|
47 |
Utvärdering av nano- och ultrafilter för avskiljning av cyanotoxiner i dricksvatten : Effekter av membrantyp och råvattenkvalitetTakman, Maria January 2015 (has links)
The drinking water production in Sweden is facing challenges because of climatic changes, eutrophication and brownification, which contributes to an increase of algal blooms. This can lead to a production of different types of toxins, and the most common group of algal toxins is the hepatotoxic microcystins (MC). Other algal toxins that occur in Sweden are anatoxin-A (ATX-A) and the paralytic shellfish toxins (PST), which are neurotoxic. Flocculation and filtration has been shown to reduce intracellular MC, but to reduce extracellular MC it seems like other techniques are needed, such as membrane filtration, active carbon or ozone. It has also been shown that dissolved organic carbon (DOC) might affect the reduction of MC, either through occupying adsorption spots on the membrane, or through bindings between MC and DOC. In this project, the reduction of four types of added MC (microcystin-LR, microcystin-RR, microcystin-LY and (D-Asp3)microcystin-LR) with two nanofilters (NF) (with molecular weight cutoff (MWCO) 300-500 Da and 1000 Da) and one ultrafilter (UF) (MWCO 10000 Da) was studied. Further, the sorption between toxins and membrane or between toxins and DOC was studied. Water samples from three Swedish lakes were used to achieve a varying DOC-character. The reduction was also studied in synthetic water (MilliQ-water with adjusted pH and conductivity). This was done in order to study if the reduction was affected of the presence of DOC. The reduction of ATX-A and PST was studied in one experiment, with an NF-membrane (MWCO 1000 Da). The studied PST’s were saxitoxin (STX), N-sulfocarbamoyl-gonyautoxin-2 (C1) and Gonyuatoxin‑2 (GTX2). MC was reduced to under the limit of detection for all NF-experiments, while a low or no reduction was observed with UF. MC-RR was the toxin that, to the biggest extent, bound to the membrane or to DOC. MC seemed to bind to the membrane or to DOC to a higher extent when the DOC was hydrophilic and low molecular autochthonous, as compared to when the DOC was allochthonous. The reduction of ATX-A and PST was 20 – 40 %, with a reduction that declined during the experiment. C1, the PST with highest molecular weight and lowest net charge, was reduced to the lowest extent, while STX, the PST with the lowest molecular weight and the greatest net charge, was reduced to the highest extent. This implies that size exclusion was not a contributing reduction mechanism for ATX-A or PST, while electrostatic mechanisms probably were more important.
|
48 |
Charakterisierung der Mikrostruktur und der Permeationseigenschaften von Polysiloxan-Netzwerken / Permeation Properties of Polysiloxane NetworksBergner, Annina January 2005 (has links) (PDF)
Ziel dieser Arbeit war es, die Permeationseigenschaften von Polysiloxan-Membranen im Hinblick auf ihre definierte Mikrostruktur näher zu analysieren. Es konnte gezeigt werden, dass die Mikrostruktur der Membranen einen statistisch signifikanten Einfluss auf die Permeationsgeschwindigkeit der untersuchten Substanzen hat. Zum besseren Verständnis der Permeation wurden auch die Diffusionsvorgänge innerhalb der Membran untersucht. Durch den Einsatz der Konfokalen Raman-Spektroskopie ist es gelungen, den Aufbau eines Konzentrationsgradienten innerhalb der Membran zu zeigen. Weiterhin konnte der Einfluss der Mikrostruktur der Membranen auf die Geschwindigkeit des Aufbaus dieses Gradienten nachgewiesen werden. / It was the aim of this project to find out how the permeability of a given molecule through a polysiloxane membrane with defined microstructure is determined by its physico-chemical properties. It turned out that the network chain length takes a statistically significant influence on the permeability of the tested compounds. Confocal Raman-spectroscopy was taken as a pioneering method to investigate the kinetics of diffusion within a membrane before the steady state has been reached. It was able to show the formation of the concentration gradient of ß-carotene in polysiloxane membranes. Additionally the influence of the microstructure before reaching steady state conditions could be observed.
|
49 |
Influence de l'organisation latérale de la membrane sur l'activation lymphocytaire T / Influence of the lateral membrane organization on T cell activationSalles, Audrey 16 December 2010 (has links)
Les rafts lipidiques sont des nanodomaines membranaires enrichis en cholestérol et en sphingolipides impliqués dans la régulation de la signalisation médiée par le TCR. Néanmoins l'existence et la fonction de ces domaines sont sujettes à controverse compte tenu des difficultés expérimentales pour les étudier in vivo. En utilisant des traitements non invasifs ciblant spécifiquement la voie de biosynthèse de ces lipides, nous avons étudié l'influence de l'organisation latérale de la membrane sur l'activation lymphocytaire T. Par des approches biophysiques, nous avons démontré au sein de lymphocytes T primaires CD4+, que les molécules TCR, CD4 et Lck sont constitutivement partitionnées dans les rafts lipidiques dont est exclue CD45. De plus, cette préorganisation moléculaire modifie les paramètres d'adhésion entre le TCR. Pour étudier le rôle de ces structures au sein de cellules individuelles, nous avons développé une nouvelle méthodologie permettant de détecter et d'analyser à haut débit et de manière automatique la réponse calcique des cellules T. Nous avons confirmé l'influence des rafts membranaires dans la signalisation TCR par les rafts lipidiques joue un rôle majeur dans l'initiation de la reconnaissance antigénique des cellules T. / Lipid rafts are membrane nanodomains enriched in chrolesterol and sphingolipids, which ahave previously been implanted in TCR signaling mechanisms. This contention, however, has beacome highly controversial due to experimental difficulties to study these membrane organizations in vivo. Using non invasive treatments that target specific lipid biosynthesis, we have studied the influence of lateral membrane organization in T lymphocyte activation. By using biophysical approaches, we have demonstrated that in murine CD4+Tcelles, TCR, CD4 and Lck are constitutively and dynamically trapped in lipid rafts, whereas CD45 is excluded. Moreover, this pre-organization impacts binding of TCR to the MHC II-peptide complex and controls the initiation of early TCR signaling. To investigate the role of these structures within individual live cells, we have developed a new high throughput methodology to monitor the calcium mobilization in T cells. We have confirmed the influence of membrane rafts in TCR signaling. Our results have thus demonstrated that pre-organization of TCR signaling protagonists by lipid rafts play a major role in the initiation of T cell antigen recognition
|
50 |
Clinical evaluation of novel methods to determine dialysis parameters using conductivity cells / Klinische Untersuchung neuer Methoden zur Ermittlung von Dialyseparametern mit Hilfe von Leitfähigkeits-MesszellenGoldau, Rainer January 2002 (has links) (PDF)
During the last two decades an ongoing discussion about the necessary dose of dialysis brought the result that the urea based Kt/V value is significantly correlated to morbidity of the end stage renal disease (ESRD) patients. Even if it is not completely accepted, it seems to be more and more agreement of the nephrological community that for good dialysis practice Kt/V should be kept above 1.2 to 1.3 in the usual 3X4 hours per week dialysis schedule for patients without own residual clearance to assure long term quality of life, low morbidity and mortality. K is the clearance of urea the dialysis system can apply, t is the treatment time and V is the urea distribution volume of the patient, which is nearly equal to total body water. Kt/V has the unit of a drug dose (ml of drug per ml of patient volume) and therefore sometimes is called dialysis 'dose', even if this is subject of discussion because it implies that the dose can be described with only one urea related number. This work does not participate in this discussion. The premise of this work is more technical: Whatever the final result of the above discussion will be, a patient-friendly, precise cost-neutral and handy technical solution should be given to the hand of the interested nephrologist to continuously supervise the urea based Kt/V that is applied to the patient. Of course this is combined with the hope that the long term mortality can be decreased if a covering online dialysis success control is facilitated. The technical solution that has been chosen is based on the equivalence of the diffusion coefficients of sodium chloride and urea. It is central subject of the investigation if the diffusive behaviour of sodium is equal to that of urea crossing the dialysis filter membrane. The advantage that makes the principle so handy is that sodium can be measured very precise by standard conductivity cells as they are implemented in dialysis machines in large numbers. The only necessary hardware modification is a second conductivity cell downstream the dialyser to be able to measure the mass balance over the filter. This is more complicated with urea that can only be measured undergoing an enzymatic conversion to ammonium ions. The ammonium ions induce a membrane potential, which is measured with very sensitive amplifiers. A cooling chain for the enzyme must be maintained. To find and approve the conductivity based technical solution two in-vivo studies have been conducted. In the first study a conductivity step profile, varying the conductivity in static levels in a baseline - 7 min high - 7min low- baseline shape, was applied that can be utilised to measure the urea clearance very accurate. This principle has been described in 1982 in a patent application. In a sequence of 206 computer recorded dialysis sessions with 22 patients it was found that urea clearance could be electrolytically measured with a mean error+/-standard deviation of -1.46+/-4.75% , n=494. The measurement of Kt/V according to a single pool model was of similar accuracy: 2.88+/-4.15% . Although in accordance with other studies these findings at an average confirmed the high correlation of ionic and urea based clearance measurements, an effect was found that was not consistent with the theory that was existent so far. It was found in the first study that the accuracy of the step profile measurements were dependent of the size of the patient, in particular of the urea distribution volume. Moreover it was of relevance which part of the step profile was used: the high-low states, the baseline- low or the baseline-high states. This was a theoretical lack. Careful analysis led to the result that sodium transfer from and into the patient was the reason for the dependence. This led to the enhancement of the theory that seems to correctly describe the nature of the effect. A new demand now was to minimise the sodium transfer. This was limited using static step profiles because in the time it needs to become stable sodium is shifted. In consequence non-stable, dynamic short conductivity boli were developed that allowed to minimise the amount of sodium to be shifted to the limits of the technical resolution of the measurement systems. Also the associated mathematical tools to evaluate the boli had to be suited to the problem. After termination of this process a second study was conducted to approve the new method found. In this study with 10 patients and 93 sessions, 264 step profile measurements and 173 bolus ionic dialysance measurements it was found that the bolus measurements matched their related blood side urea clearance references with the outstanding accuracy of (error+/-SD) 0.06+/-4.76%. The result was not significantly different (p=0.87) from the reference by student's t-test for paired data. The Kt/V reference according to the single pool variable volume urea kinetic model (sPVVUKM) was found to be matched by the bolus principle with 5.32+/-3.9% accuracy and a correlation of 0.98. The remaining difference of 5.32% can be attributed to the neglect of the urea generation rate. Also the step profile was found to be very precise here. The error versus sPVVUKM was 0.05%+/-5%, r=0.96. However it did not image the neglect of urea generation correctly. Also a two pool modelling that comprises an internal compartimentation of the fluid pools of the patient was applied to the continuously recorded data. This two pool urea kinetic model (2PUKM) is regarded to be a more precise theoretical approach and now includes the urea generation. It found the bolus principle to deviate -3.04 +/- 14.3%, n.s., p=0.13. The high standard deviation is due to the complexity of the model. Further from the developed theory a simplified method to roughly measure the sodium distribution volume could be derived. This method was tested in-vitro versus a container with dialysate of known volume and in-vivo versus the urea distribution volume. The in-vitro results were -19.9+/-34%, r=0.92, n.s, p=0.916. In-vivo they were found to be -7.4+/-23.2%, r=0.71, n.s., p=0.39. Due to dilution theory the sodium and urea distribution volumes virtually appear to be very similar using this method, although they absolutely differ significantly. Facing the strong simplifications that were made before applying this theory these results seem to be very encouraging that it could be possible to develop a principle to measure not only K but also V electrolytically. This would allow a true Kt/V measurement. The empirical urea distribution volume measurement using anthropometrical formulas has been compared to analytical methods. It has been found that the use Watson's formula with a -13% correction gives good results. The correction should be applied with great care because it increases Kt/V just on a arithmetical base to the disadvantage of the patient. Also electrolytical plasma sodium measurement was evaluated and can be measured using a mixed analytic-empirical formula with an accuracy of 4.3+/-1.2%. In summary, conductivity based methods seem to be a convenient method to measure several dialysis parameters of some clinical interest without effort. The results of this work meanwhile are implemented with substantial numbers into commonly available dialysis machines and the experience of the first time shows that the principle is well accepted by the clinicians. / Eine die letzten beiden Jahrzehnte anhaltende Diskussion über die erforderliche Dosis Dialyse, die ein Patient benötigt, ergab, daß der Harnstoff-basierte Kt/V-Wert signifikant mit der Morbidität von ‚end stage renal deasease' (ESRD)- Patienten korreliert. Wenn auch nicht vollständig akzeptiert, so scheint es doch zunehmende Übereinkunft zwischen Nephrologen, daß eine angemessene Dialysebehandlung von Patienten ohne Restdiurese im Rahmen eines 3x4 Stunden pro Woche- Schemas mindestens einen Kt/V-Wert von 1.2 bis 1.3 ergeben sollte, um auf lange Sicht die Lebensqualität zu sichern und die Morbidität und Mortalität niedrig zu halten. K ist die vom Dialysesystem erbrachte Clearance, t die Behandlungszeit und V das Harnstoff-Verteilungsvolumen, welches dem Gesamt-Körperwasser nahezu gleicht. Kt/V wird in der Dosiseinheit (ml Medikament pro ml Körperwasser) ausgedrückt und daher auch häufig als Dialyse-‚Dosis' bezeichnet, auch wenn darüber wegen der Zusammenfassung in nur einer Harnstoff-korrelierten Zahl konträr diskutiert wird. Diese Arbeit besitzt eine eher technische Prämisse und möchte sich nicht an dieser Diskussion beteiligen. Sie möchte dem interessierten Nephrologen lediglich eine patientenfreundliche, präzise, kostenneutrale und leicht zu handhabende technische Lösung an die Hand geben, um kontinuierlich die in Kt/V ausgedrückte Dialysedosis zu überwachen. Natürlich ist damit auch die Hoffnung verbunden, daß die Langzeit-Sterblichkeit verringert werden kann, wenn eine flächendeckende, zeitnahe Erfolgskontrolle der Dialyse ermöglicht wird. Die gewählte technische Lösung basiert auf der Äquivalenz der Diffusionskoeffizienten von gelöstem Harnstoff und Natriumchlorid. Es ist das zentrale Anliegen dieser Studie, festzustellen, ob das Diffusionsverhalten von NaCl und Harnstoff beim Durchtritt durch die Membran des Dialysefilters gleich ist. Der entscheidende Vorteil, der das Verfahren so leicht handhabbar macht, besteht darin, daß NaCl-Konzentrationen sehr genau durch die ohnehin in großer Zahl in Dialysegeräten verwendeten Leitfähigkeitsmeßzellen bestimmt werden können. Um die NaCl-Massenbilanz über den Dialysefilter zu bestimmen, benötigt man lediglich eine weitere Meßzelle, die stromab des Filters zu installieren ist. Die Messung von Harnstoff, die indirekt über die enzymatische Zerlegung in Ammonium-Ionen und das anschließende Erzeugen eines hoch zu verstärkenden elektrischen Potentials an einer Membran geschieht, ist komplizierter. Zudem ist eine geschlossene Kühlkette für das Enzym sicher zu stellen. Um eine leitfähigkeitsbasierte technische Lösung abzusichern, wurden zwei klinische Studien durchgeführt. In der ersten Studie wurde die Leitfähigkeit in Form von konstanten Stufenprofilen variiert. Sie wurde ausgehend von der Grundlinie für 7 min erhöht und anschließend für 7 min erniedrigt. Das Prinzip einer solchen Messung wurde erstmals 1982 in einer Patentschrift beschrieben. In einer Sequenz von 494 solchen Messungen in 206 automatisch aufgezeichneten Dialysesitzungen an 22 Patienten wurde gefunden, daß sich die Harnstoff- Clearance elektrolytisch mit einer Genauigkeit von -1.46+/-4.75% (Fehler+/-Standardabweichung) messen ließ. Die Messung von Kt/V gemäß dem Ein-Kompartment-Modell ergab eine ähnliche Genauigkeit von 2.88+/-4.15%. Obgleich diese Ergebnisse in Übereinstimmung mit anderen Studien stehen, wurde ein Effekt bemerkt, der nicht in Einklang mit der zunächst bestehenden Theorie zu bringen war. Dieser Effekt besteht darin, daß die Genauigkeit der elektrolytischen Clearancemessung vom beim Patienten vorhandenen Harnstoff-Verteilungsvolumen abhängig war. Weiter war es nicht bedeutungslos, welchen Teil des dreiteiligen Stufenprofils man zur Auswertung heranzog: Den Grundlinie-Hoch- Übergang, den von der Grundlinie zum Niedrig-Nieveau oder den Hoch-Niedrig- Übergang. Dies deutete auf einen Mangel an theoretischem Verständnis hin. Eine genaue weitere Untersuchung führte zu dem Ergebnis, daß unerwünschter NaCl-Transfer vom und zum Patienten die Ursache für die Abhängigkeit vom Verteilungsvolumen war. Es wurde daraufhin die Theorie dahingehend erweitert, daß dieser Effekt korrekt und plausibel beschrieben werden konnte. Aus dieser Erweiterung ergab sich die neue Forderung, den NaCl-Transfer bei der Messung weitestgehend zu minimieren. Die Benutzung von Stufenprofilen stellte hier jedoch an sich eine Limitierung dar, da in der zum Einnehmen eines stabilen Zustandes erforderlichen Zeit zuviel NaCl über die Membran transferiert wurde. Die Konsequenz war, von den Stufenprofilen auf kurze, dynamische Leitfähigkeitsboli überzugehen, die erlaubten, die NaCl-Gabe auf das Maß zu verringern, welches aufgrund der technischen Auflösung erforderlich war. Hierzu mußten jedoch die notwendigen mathematischen Algorithmen neu zugeschnitten werden. Nach diesem Schritt wurde eine weitere klinische Studie gestartet, die den Zweck verfolgte, das neue Verfahren am Patienten zu verifizieren. In dieser Studie mit 10 Patienten und 93 Dialysesitzungen, 264 Stufenprofil- und 173 Bolus-Dialysancemesssungen wurde gefunden, daß die Bolus-Messungen ihre zugehörigen blutseitigen Referenzmessungen mit außergewöhnlicher Genauigkeit von 0.06+/-4.76% trafen. Student's t-Test für gepaarte Daten ergab, daß sich die Datensätze nicht signifikant unterschieden (p=0.87). Die blutseitige Kt/V-Referenz auf der Basis des equilibrierten Einkompartment-Modells mit variablem Volumen wurde mit 5.32+/-3.9% getroffen, wobei eine Korrelation von 0.98 erzielt wurde. Die verbleibende Differenz von 5.32% wird der Vernachlässigung der Harnstoff-Erzeugung während der Messung zugeschrieben. Auch das Stufenprofil zeigte trotz seiner Abhängigkeit vom Verteilungsvolumen gegenüber dem gleichen Modell einen mittleren Fehler von 0.05+/-5% bei einer Korrelation von 0.96. Jedoch konnte es die Vernachlässigung der Harnstoff-Erzeugung nicht korrekt abbilden. Die kontinuierlich aufgenommenen Daten wurden auch nach dem 2-pool Modell untersucht, welches auch die Harnstoff-Erzeugung enthält sowie eine innere Kompartimentierung des Patienten annimmt und damit die tatsächlichen Verhältnisse besser beschreibt. Danach weicht das Bolus-Meßprinzip -3.04+/-14.3% von der Referenz ab (n.s.,p=0.13). Die relativ hohe Standardabweichung wird mit der Komplexität des Modells erklärt. Weiter ist aus der Theorie zum Na-Transfer eine vereinfachende Methode zur Messung des Na-Verteilungsvolumens abgeleitet worden. Diese Methode wurde in-vitro gegen ein Behältnis mit einer bekannten Menge an Dialysat geprüft. Es wurde ein mittlerer Fehler von -19.9+/-34% gefunden. Die Korrelation war 0.92 (n.s., p=0.916). Die gleiche Prüfung fand in-vivo gegen das Harnstoff-Verteilungsvolumen statt und ergab einen mittleren Fehler von -7.4+/-23.2% (r=0.71, n.s., p=0.39). Es hat den Anschein, als würden sich gemäß der Theorie der Dilution die Verteilungsvolumina für Natrium und für Harnstoff scheinbar nur wenig unterscheiden, obwohl sie sich absolut natürlich deutlich unterscheiden. In Anbetracht der erheblichen Vereinfachungen, die bei der Ableitung dieses Ansatzes gemacht wurden, scheint es ausgesprochen ermutigend, auf diesem Weg möglicherweise ein Verfahren entwickeln zu können, welches auf rein elektrolytischem Wege nun nicht mehr nur K, sondern auch V und damit alle zur Quantifizierung gesuchten Größen analytisch ermitteln kann. Weiter wurde im Rahmen dieser Arbeit anhand der analytisch ermittelten Volumina verglichen, ob man mit Hilfe anthropometrischer Formeln zur Ermittlung des Harnstoff-Verteilungsvolumens zu einer guten Abschätzung kommen kann. Es wurde gefunden, daß man das Ergebnis der Watson-Formel um ca. 13% vermindern kann und dann zu einem recht guten Wert für das tatsächliche Harnstoff-Verteilungsvolumen gelangt. Dies ist jedoch mit Vorsicht und Erfahrung zu tun, da sich damit Kt/V rechnerisch zum Nachteil des Patienten verändert. Auch ein elektrolytisches Verfahren mit empirischen Komponenten zur Ermittlung des Plasma-Natriums des Patienten wurde erprobt und konnte mit einer Genauigkeit von 4.3+/-1.2% den Laborwert vorhersagen. Zusammenfassend kann gesagt werden, daß sich im Rahmen dieser Arbeit die leitfähigkeitsbasierten Methoden zur Messung von einigen wichtigen Dialyseparametern als sehr nützlich für die klinische Praxis erwiesen haben und zudem mit keinem Zusatzaufwand für die Beteiligten verbunden sind. Das Ergebnis dieser Arbeit ist mittlerweile in größeren Stückzahlen in frei erhältliche Dialysegeräte implementiert worden. Die Erfahrung der ersten Zeit zeigt, daß das verwendete Prinzip von den Klinikern gut angenommen wird.
|
Page generated in 0.0555 seconds