• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e validação de método analítico para análise de parabenos em tecido de peixes / Development and validation of the analytical method for analysis of parabens in fish tissue

Ribeiro, Gabriela Lemos de Oliveira 11 December 2014 (has links)
O presente estudo teve como objetivo desenvolver e validar um método analítico para a investigação de parabenos em tecido de peixe. Para o preparo de amostra empregou-se como método a microextração líquido-líquido (LLME) seguido de análise cromatográfica líquida de alta eficiência acoplada a um detector de arranjo de diodos. Empregou-se coluna Nucleodur C8 (4,6 x 250 mm, 5 µm), com injeção de 20µL, fluxo de 1mL min-1, temperatura de 25 °C, comprimento de onda 258nm e fase móvel composta por água acidificada com 1% de ácido acético e metanol em modo gradiente na proporção de 60% de metanol até 8 minutos e de 65% até 20 minutos. A recuperação do método para o metilparabeno nas concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 foi de 94; 95; 89; 83; 100 e 74% respectivamente e o desvio padrão relativo foi de 7,0; 0,5; 3,2; 10,0; 5,2 e 2,9 %para as seis concentrações. A recuperação do etilparabeno foi de 107; 103; 80; 89; 89 e 88% para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 7,4; 4,1; 12,2; 3,2; 7,7 e 3,6 % respectivamente. A recuperação do propilparabeno foi de 106; 96; 94; 97; 100 e 76 % para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 14,2; 8,6; 14,9; 4,0; 7,9 e 2,6 % respectivamente. A recuperação do butilparabeno foi de 102; 74; 96; 79; 112 e 78% para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 7,7; 4,0; 9,1; 5,5; 2,0 e 4,2 % respectivamente. Os limites de detecção variaram de 0,0007 a 0,0221 µgL-1 e os de quantificação de 0,0021 a 0,0738 µgL-1. Os coeficientes de correlação ficaram entre 0,9837 a 0,9906 dentro do limite estabelecido pela Agência Nacional de Vigilância Sanitária para matrizes biológicas. O método foi aplicado em três amostra de peixes adquiridos no comércio de São Carlos - SP. Em 50% das amostras analisadas encontrou-se picos cromatográficos nos mesmos tempos de retenção dos padrões dos parabenos. A concentração do etilparabeno foi de 0,0438 µgg-1, para o propilparabeno a concentração foi de 0,0365 a 0,0564 µgg-1 e para o butilparabeno a concentração foi de 0,0322 a 0,0678 µgg-1. O metilparabeno foi o único que não foi encontrado nas amostras de tecido dos peixes analisadas. / his research aimed to develop and validate a new chromatographic method combined with liquid-liquid microextraction (LLME) for the determination and quantification of parabens in fish tissue. A high performance liquid chromatography coupled with diode array detection was employed with a Nucleodur C8 ec column (250 x 4.6 mm, 5 µm), injection volume of 20?L, wavelength of 258nm, flow rate of 1 mL min-1, temperature of 25 ° C and gradient mode, using 1% of acetic acid diluted in water and methanol, in the proportion of 60% of methanol until 8 minutes and 65% within 20 minutes. The liquid-liquid microextraction (LLME) provided adequate recoveries of 94; 95; 89; 83; 100 and 74% for the methylparaben at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively, with accuracy of 7,0; 0,5; 3,2; 10,0; 5,2 and 2,9 %. The recoveries for the ethylparaben was 107; 103; 80; 89; 89 and 88% at concentration of 0,05; 0,1; 0,25; 0,5; 0,8 and 1,0 µgg-1 respectively,with accuracy of 7,4; 4,1; 12,2; 3,2; 7,7 and 3,6 % The recoveries for the propylparaben was 106; 96; 94; 97; 100 and 76 % at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively, with accuracy of 14,2; 8,6; 14,9; 4,0; 7,9 and 2,6 % . The recoveries for the butylparaben was 102; 74; 96; 79; 112 and 78%at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively,with accuracy of 7,7; 4,0; 9,1; 5,5; 2,0 and 4,2 %. The method detection limits (MDLs) ranged from 0,0007 a 0,0221 µgL-1 and the method quatification limists (MQLs) ranged from 0,0021 a 0,0738 µgL-1. The correlation coefficients ranged from 0.9837 to 0.9906 not further than the limits established by the Agência Nacional de Vigilância Sanitária for complex samples. The method LLME/HPLC-DAD was applied to the analysis of three samples from the market of São Carlos-SP. In 50% of the samples analysed, chromatographic peaks were found at the same retention times of parabens. The ethylparaben concentrations founded was 0,0438 µgg-1, for propylparaben concentration ranged from 0,0365 to 0,0564 µgg-1 and for butylparaben concentration ranged from 0,0322 to 0,0678 µgg-1. The methylparaben was not found in the fish tissue sample analyzed.
2

Desenvolvimento e validação de método analítico para análise de parabenos em tecido de peixes / Development and validation of the analytical method for analysis of parabens in fish tissue

Gabriela Lemos de Oliveira Ribeiro 11 December 2014 (has links)
O presente estudo teve como objetivo desenvolver e validar um método analítico para a investigação de parabenos em tecido de peixe. Para o preparo de amostra empregou-se como método a microextração líquido-líquido (LLME) seguido de análise cromatográfica líquida de alta eficiência acoplada a um detector de arranjo de diodos. Empregou-se coluna Nucleodur C8 (4,6 x 250 mm, 5 µm), com injeção de 20µL, fluxo de 1mL min-1, temperatura de 25 °C, comprimento de onda 258nm e fase móvel composta por água acidificada com 1% de ácido acético e metanol em modo gradiente na proporção de 60% de metanol até 8 minutos e de 65% até 20 minutos. A recuperação do método para o metilparabeno nas concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 foi de 94; 95; 89; 83; 100 e 74% respectivamente e o desvio padrão relativo foi de 7,0; 0,5; 3,2; 10,0; 5,2 e 2,9 %para as seis concentrações. A recuperação do etilparabeno foi de 107; 103; 80; 89; 89 e 88% para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 7,4; 4,1; 12,2; 3,2; 7,7 e 3,6 % respectivamente. A recuperação do propilparabeno foi de 106; 96; 94; 97; 100 e 76 % para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 14,2; 8,6; 14,9; 4,0; 7,9 e 2,6 % respectivamente. A recuperação do butilparabeno foi de 102; 74; 96; 79; 112 e 78% para as seguintes concentrações 0,05; 0,1; 0,25; 0,5; 0,8 e 1,0 µgg-1 e o desvio padrão foi de 7,7; 4,0; 9,1; 5,5; 2,0 e 4,2 % respectivamente. Os limites de detecção variaram de 0,0007 a 0,0221 µgL-1 e os de quantificação de 0,0021 a 0,0738 µgL-1. Os coeficientes de correlação ficaram entre 0,9837 a 0,9906 dentro do limite estabelecido pela Agência Nacional de Vigilância Sanitária para matrizes biológicas. O método foi aplicado em três amostra de peixes adquiridos no comércio de São Carlos - SP. Em 50% das amostras analisadas encontrou-se picos cromatográficos nos mesmos tempos de retenção dos padrões dos parabenos. A concentração do etilparabeno foi de 0,0438 µgg-1, para o propilparabeno a concentração foi de 0,0365 a 0,0564 µgg-1 e para o butilparabeno a concentração foi de 0,0322 a 0,0678 µgg-1. O metilparabeno foi o único que não foi encontrado nas amostras de tecido dos peixes analisadas. / his research aimed to develop and validate a new chromatographic method combined with liquid-liquid microextraction (LLME) for the determination and quantification of parabens in fish tissue. A high performance liquid chromatography coupled with diode array detection was employed with a Nucleodur C8 ec column (250 x 4.6 mm, 5 µm), injection volume of 20?L, wavelength of 258nm, flow rate of 1 mL min-1, temperature of 25 ° C and gradient mode, using 1% of acetic acid diluted in water and methanol, in the proportion of 60% of methanol until 8 minutes and 65% within 20 minutes. The liquid-liquid microextraction (LLME) provided adequate recoveries of 94; 95; 89; 83; 100 and 74% for the methylparaben at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively, with accuracy of 7,0; 0,5; 3,2; 10,0; 5,2 and 2,9 %. The recoveries for the ethylparaben was 107; 103; 80; 89; 89 and 88% at concentration of 0,05; 0,1; 0,25; 0,5; 0,8 and 1,0 µgg-1 respectively,with accuracy of 7,4; 4,1; 12,2; 3,2; 7,7 and 3,6 % The recoveries for the propylparaben was 106; 96; 94; 97; 100 and 76 % at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively, with accuracy of 14,2; 8,6; 14,9; 4,0; 7,9 and 2,6 % . The recoveries for the butylparaben was 102; 74; 96; 79; 112 and 78%at concentration of 0,05; 0,1; 0,25; 0,5; 0,8; 1,0 µgg-1 respectively,with accuracy of 7,7; 4,0; 9,1; 5,5; 2,0 and 4,2 %. The method detection limits (MDLs) ranged from 0,0007 a 0,0221 µgL-1 and the method quatification limists (MQLs) ranged from 0,0021 a 0,0738 µgL-1. The correlation coefficients ranged from 0.9837 to 0.9906 not further than the limits established by the Agência Nacional de Vigilância Sanitária for complex samples. The method LLME/HPLC-DAD was applied to the analysis of three samples from the market of São Carlos-SP. In 50% of the samples analysed, chromatographic peaks were found at the same retention times of parabens. The ethylparaben concentrations founded was 0,0438 µgg-1, for propylparaben concentration ranged from 0,0365 to 0,0564 µgg-1 and for butylparaben concentration ranged from 0,0322 to 0,0678 µgg-1. The methylparaben was not found in the fish tissue sample analyzed.
3

Análise enantiosseletiva da mefloquina em plasma: avaliação da técnica de microextração em fase líquida / Enantioselective analysis of mefloquine in plasma: evaluation on the liquid-phase microextration technique

Magalhães, Igor Rafael dos Santos 28 July 2006 (has links)
A mefloquina (MQ), fármaco utilizado na profilaxia e tratamento da malária ocasionada por Plasmodium falciparum resistente à cloroquina, é comercializada na forma racêmica. Apresenta disposição cinética estereosseletiva e ação farmacológica diferencial entre os enantiômeros. A maioria dos métodos analíticos desenvolvidos para análise do fármaco em plasma utiliza como técnicas de preparação das amostras, a extração líquido-líquido ou a extração em fase sólida. Por outro lado, a microextração em fase líquida (LPME), técnica recentemente desenvolvida, pode oferecer resultados bastante satisfatórios para amostras complexas, como fluidos biológicos. Portanto, o presente trabalho teve por finalidade o desenvolvimento e validação de um método analítico empregando a cromatografia líquida de alta eficiência com fases estacionárias quirais juntamente com a LPME para a análise enantiosseletiva da MQ em plasma. Empregando-se a coluna Chiralpak AD com fase móvel constituída por hexano/etanol/DEA (97:3:0,05, v/v/v), obteve-se a separação dos enantiômeros da MQ, com tempos de retenção reduzidos e resolução apropriada. Utilizando-se uma membrana capilar de polipropileno, juntamente com éter diexílico (fase orgânica) e ácido perclórico 10 mmol L-1 (fase aceptora) como componentes do sistema de três fases, obteve-se excelente isolamento dos interferentes endógenos aliado a um enriquecimento satisfatório dos analitos, sendo então possível a validação do método desenvolvido. A metodologia otimizada apresentou linearidade satisfatória no intervalo de 50 ? 1500 ng mL-1 com coeficientes de determinação > 0,998 para ambos enantiômeros. Os valores de recuperação absoluta de (-)-(SR)-MQ e (+)-(RS)-MQ foram 33,2% e 35,0%, respectivamente. Precisão e exatidão, avaliadas por estudos intra-ensaio e interensaio, foram < 15% para ambos enantiômeros. Além disso, não foram observadas racemização ou degradação do fármaco durante a preparação das amostras e análise cromatográfica. Posteriormente, o método desenvolvido e validado foi aplicado em um estudo-piloto de disposição cinética em ratos. Verificou-se que a disposição cinética da MQ em ratos foi estereosseletiva, já que maiores concentrações de (+)-(RS)-MQ foram obtidas em todos os tempos de análise avaliados. / Mefloquine (MQ), a drug used for prophylaxis and treatment of malaria caused by chloroquine-resistant strains of Plasmodium falciparum, is commercialized as a racemic mixture. MQ enantiomers demonstrate differential stereoselective dispositions and pharmacodynamic actions. The majority of methods developed for the determination of mefloquine in plasma includes liquid-liquid or solid-phase extraction as sample preparation. On the other hand, liquid-phase microextraction (LPME), a recently developed technique, may offer satisfactory results for complex matrices, such as biological fluids. Therefore, the aim of this work was to develop and validate an analytical method using chiral high-performance liquid chromatography combined with LPME for the enantioselective analysis of MQ in plasma. Employing a Chiralpak AD column with hexane/ethanol/DEA (97:3:0.05, v/v/v) as mobile phase, separation of MQ enantiomers was achieved with short retention times and appropriate resolution. Using a polypropylene-based capillary membrane together with di-n-hexyl ether (organic phase) and 10 mmol L-1 perchloric acid (acceptor phase) as components of a three-phase system, an excelent clean-up of endogenous interferents, allied with a satisfactory enrichment of analytes, was obtained, which allowed method validation. The optimized methodology exhibited good linearity over a 50 - 1500 ng mL-1 range with correlation coefficients of > 0.998 for both enantiomers. The mean recoveries of (-)-(SR)-MQ and (+)-(RS)-MQ were 33.2 and 35.0%, respectively. Precision and accuracy, demonstrated by within-day and between-day assays, were lower than 15% for both enantiomers. Furthermore, no racemization or degradation were seen during sample preparation and chromatographic analysis. Finally, the developed and validated method was applied to a pilot pharmacokinetic assay in rats. An enantiosselective kinetic disposition of MQ enantiomers was observed in rat plasma, as concentrations of (+)-(RS)-MQ were greater than its antipode at all measured times.
4

Análise enantiosseletiva da mefloquina em plasma: avaliação da técnica de microextração em fase líquida / Enantioselective analysis of mefloquine in plasma: evaluation on the liquid-phase microextration technique

Igor Rafael dos Santos Magalhães 28 July 2006 (has links)
A mefloquina (MQ), fármaco utilizado na profilaxia e tratamento da malária ocasionada por Plasmodium falciparum resistente à cloroquina, é comercializada na forma racêmica. Apresenta disposição cinética estereosseletiva e ação farmacológica diferencial entre os enantiômeros. A maioria dos métodos analíticos desenvolvidos para análise do fármaco em plasma utiliza como técnicas de preparação das amostras, a extração líquido-líquido ou a extração em fase sólida. Por outro lado, a microextração em fase líquida (LPME), técnica recentemente desenvolvida, pode oferecer resultados bastante satisfatórios para amostras complexas, como fluidos biológicos. Portanto, o presente trabalho teve por finalidade o desenvolvimento e validação de um método analítico empregando a cromatografia líquida de alta eficiência com fases estacionárias quirais juntamente com a LPME para a análise enantiosseletiva da MQ em plasma. Empregando-se a coluna Chiralpak AD com fase móvel constituída por hexano/etanol/DEA (97:3:0,05, v/v/v), obteve-se a separação dos enantiômeros da MQ, com tempos de retenção reduzidos e resolução apropriada. Utilizando-se uma membrana capilar de polipropileno, juntamente com éter diexílico (fase orgânica) e ácido perclórico 10 mmol L-1 (fase aceptora) como componentes do sistema de três fases, obteve-se excelente isolamento dos interferentes endógenos aliado a um enriquecimento satisfatório dos analitos, sendo então possível a validação do método desenvolvido. A metodologia otimizada apresentou linearidade satisfatória no intervalo de 50 ? 1500 ng mL-1 com coeficientes de determinação > 0,998 para ambos enantiômeros. Os valores de recuperação absoluta de (-)-(SR)-MQ e (+)-(RS)-MQ foram 33,2% e 35,0%, respectivamente. Precisão e exatidão, avaliadas por estudos intra-ensaio e interensaio, foram < 15% para ambos enantiômeros. Além disso, não foram observadas racemização ou degradação do fármaco durante a preparação das amostras e análise cromatográfica. Posteriormente, o método desenvolvido e validado foi aplicado em um estudo-piloto de disposição cinética em ratos. Verificou-se que a disposição cinética da MQ em ratos foi estereosseletiva, já que maiores concentrações de (+)-(RS)-MQ foram obtidas em todos os tempos de análise avaliados. / Mefloquine (MQ), a drug used for prophylaxis and treatment of malaria caused by chloroquine-resistant strains of Plasmodium falciparum, is commercialized as a racemic mixture. MQ enantiomers demonstrate differential stereoselective dispositions and pharmacodynamic actions. The majority of methods developed for the determination of mefloquine in plasma includes liquid-liquid or solid-phase extraction as sample preparation. On the other hand, liquid-phase microextraction (LPME), a recently developed technique, may offer satisfactory results for complex matrices, such as biological fluids. Therefore, the aim of this work was to develop and validate an analytical method using chiral high-performance liquid chromatography combined with LPME for the enantioselective analysis of MQ in plasma. Employing a Chiralpak AD column with hexane/ethanol/DEA (97:3:0.05, v/v/v) as mobile phase, separation of MQ enantiomers was achieved with short retention times and appropriate resolution. Using a polypropylene-based capillary membrane together with di-n-hexyl ether (organic phase) and 10 mmol L-1 perchloric acid (acceptor phase) as components of a three-phase system, an excelent clean-up of endogenous interferents, allied with a satisfactory enrichment of analytes, was obtained, which allowed method validation. The optimized methodology exhibited good linearity over a 50 - 1500 ng mL-1 range with correlation coefficients of > 0.998 for both enantiomers. The mean recoveries of (-)-(SR)-MQ and (+)-(RS)-MQ were 33.2 and 35.0%, respectively. Precision and accuracy, demonstrated by within-day and between-day assays, were lower than 15% for both enantiomers. Furthermore, no racemization or degradation were seen during sample preparation and chromatographic analysis. Finally, the developed and validated method was applied to a pilot pharmacokinetic assay in rats. An enantiosselective kinetic disposition of MQ enantiomers was observed in rat plasma, as concentrations of (+)-(RS)-MQ were greater than its antipode at all measured times.

Page generated in 0.0904 seconds