• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 51
  • 51
  • 41
  • 41
  • 13
  • 11
  • 9
  • 9
  • 9
  • 9
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da instrumentação rotatória e reciprocante na desobturação de condutos radiculares curvos: análise por meio de microtomografia computadorizada / Evaluation of the rotary and reciprocating instrumentation for removing filling material in curved canals: a microcomputed tomographic analysis

Sávio Brandelero Junior 13 April 2016 (has links)
O presente estudo teve por objetivo avaliar ex vivo a eficiência de sistemas reciprocantes e rotatórios (Wave One e ProTaper Universal Retratamento), na desobturação de molares inferiores, por meio de microtomografia computadorizada. Foram utilizados canais mesiais com curvatura entre 20 e 40 graus, de 50 molares inferiores, preparados com ProTaper Universal, obturados com cone do próprio sistema e cimento AH Plus, pela técnica de condensação lateral. Para a desobturação, os dentes foram divididos em 5 grupos (I: Instrumentos manuais associados ao uso de brocas Gates Glidden e solvente; II: Sistema ProTaper Universal Retratamento; III: Sistema ProTaper Universal Retratamento e solvente; IV: Sistema Wave One; V: Sistema Wave One e solvente. Durante a desobturação, a quantidade de detritos extruídos, bem como o tempo de desobturação foram mensurados. A captura de imagem foi realizada por meio de microtomografia computadorizada onde foi avaliado o volume de material obturador remanescente nos canais. Os dados obtidos foram tabulados e submetidos a análise estatística por meio do teste de Kruskal-Wallis para determinar a ocorrência de diferença estatística entre os grupos experimentais (p<0,05). Nenhum dos métodos avaliados removeu por completo o material obturador. O método que utilizou o sistema ProTaper Retratamento com solvente apresentou menor volume percentual médio de material obturador remanescente no terço apical, entretanto, não houve diferença estatística significante entre os grupos testados em nenhum dos terços analisados. O sistema WaveOne com solvente teve o maior volume de extrusão de material após a desobturação. Os grupos que utilizaram o sistema ProTaper Retratamento, com e sem o auxílio da solução solvente, foram os que apresentaram menor tempo para remoção de material obturador. Concluiu-se que o uso de Sistema ProTaper Retratamento favorece uma desobturação mais rápida e com menor extrusão de material obturador. / This study aimed to evaluate ex vivo the efficiency of reciprocating and rotary systems (Wave One and ProTaper Universal Retreatment), in the disobturation of mandibular molars, using micro-computed tomography. Mesial canals were used with curvature between 20o and 40o, from 50 mandibular molars prepared with ProTaper Universal, obturated with ProTaper single cones and AH Plus sealer using the lateral condensation technique. For the disobturation, the teeth were divided into 5 groups (I: manual instruments associated with the use of Gates Glidden drills and solvent; II: Protaper Universal Retreatment system; III: Protaper Universal Retreatment system and solvent; IV: Wave One system; V: Wave One system and solvent. During the disobturation the amount of extruded debris, as well as the time of the retreatment procedure, were measured. The capture of images was performed using microcomputed tomography which assessed the volume of the filling material remaining in the canals. Data were tabulated and submitted to statistical analysis using theKruskal-Wallis test to determine the occurrence of statistical differences among the experimental groups (p<0.05). None of the methods evaluated completely removed the filling material. The method that used the ProTaper Retreatment system with solvent showed lower average percent volume of remaining filling material in the apical third. However, there was no statistically significant difference between the groups tested in any of the analyzed thirds. The Wave One system with solvent had the largest volume of extrusion material after the disobturation. Groups using the ProTaper Retreatment system, with and without the use of solvent solution, were those that demanded less time for the removal of the filling material. The study concluded that the use of ProTaper Retreatment system favors a faster disobturation and with less extrusion of filling material.
12

Efeito da Interação Entre o Flúor e a Irradiação com Lazer Nd: YAG na Prevenção de Desmineralização IN VITRO

Gomes, Angelinne Ribeiro Angelo 14 August 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-05-19T15:10:35Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE ANGELINNE UFPE final.pdf: 3581361 bytes, checksum: 1339333592e5d5e1f75e70ed7c727620 (MD5) / Made available in DSpace on 2016-05-19T15:10:35Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE ANGELINNE UFPE final.pdf: 3581361 bytes, checksum: 1339333592e5d5e1f75e70ed7c727620 (MD5) Previous issue date: 2015-08-14 / Introdução. Esforços têm sido direcionados para a redução do risco à cárie dentária através da adoção de medidas preventivas e motivacionais. Evidências recentes apontam que a irradiação com laser é eficaz no aumento da resistência dentária à desmineralização promovida durante o processo cariogênico. No entanto, ainda não há um consenso quanto a melhor forma de uso clínico do laser. Objetivos. Este estudo visou avaliar, num modelo in vitro, o efeito da interação entre e a irradiação do laser Nd:YAG com um verniz de flúor na prevenção da desmineralização do esmalte dentário. Materiais e Métodos. Cento e dez espécimes de esmalte foram distribuídos em 5 grupos, a saber: Grupo 1 – Controle, Grupo 2 – Flúor, Grupo 3 – Laser, Grupo 4 – Flúor/Laser e Grupo 5 – Laser/Flúor. Os grupos 3,4 e 5 foram subdivididos em 3 subgrupos cada de acordo com as potências utilizadas (0,5, 075 e 1W), totalizando 11 grupos com 10 espécimes cada. Os tratamentos superficiais consistiram no uso do laser Nd:YAG e verniz fluoretado isolados e em associação, seguido de um processo de desmineralização in vitro por 48 horas. Em sequência, as amostras foram escaneadas em um microtomógrafo de raios–X (XTEK XT-H 225 ST microfocos) e as imagens obtidas foram reconstruídas e processadas para quantificar a perda mineral e a diferença de densidade mineral entre as áreas exposta e não-exposta do esmalte dentário. Resultados. O grupo 1 apresentou maior perda mineral (89,8 ± 24,6μm) (p<0,001). Amostras tratadas com flúor apresentaram perda mineral semelhante aos grupos tratados com laser e associações de laser flúor (p>0,05). A diferença de densidade mineral do esmalte apresentou-se maior no grupo 1 (1.756 ± 746HU) (p<0,001). O uso isolado do flúor e os tratamentos laser/flúor demonstraram as menores médias na variação da densidade. Conclusões. O uso exclusivo do laser e suas associações com o verniz fluoretado mostraram-se semelhantes ao uso exclusivo do flúor. A associação do verniz fluoretado com o laser apresenta melhor performance quando o laser Nd:YAG é utilizado previamente ao verniz. / Introduction. Efforts have been directed to reducing the risk of caries adopting preventive and motivational measures. New found evidence suggests that the laser irradiation is effective in increasing the resistance to tooth demineralization promoted during the cariogenic process. However, there is still no consensus on the best way of laser clinical use. Objectives. This study aimed to evaluate an in vitro model, the effect of interaction between the radiation and the Nd:YAG laser with a fluoride varnish on the prevention of demineralization of dental enamel. Materials and methods. One hundred and ten enamel specimens were distributed into 5 groups as follows: Group 1 - Control, Group 2 - Fluoride, Group 3 - Laser, Group- 4 - Fluoride/Laser, Group 5 - Laser /Fluoride. Groups 3,4 and 5 were each subdivided into 3 subgroups according to the power (0.5, 075, and 1W), a total of 11 groups of 10 specimens each. The surface treatment consisted in the use of Nd: YAG laser and fluoride varnish isolated and in combination, followed by a process of demineralization in vitro for 48 hours. In the following, the specimens were scanned at a X-ray microtomography (XT-H Xtek microfocus ST 225) and images were reconstructed and processed to quantify the mineral loss and the mineral density difference between the exposed and non-exposed areas enamel. Results. Group 1 showed higher mineral loss (89.8 ± 24,6μm) (p <0.001). Samples treated with fluoride mineral loss showed similar to the groups treated with laser and Fluorine laser associations. The difference mineral density was higher in Group 1 (1.756 ± 746HU) (p <0.001). The isolated use of fluoride and treatments laser/fluoride promoted smaller mean of density. Conclusions. The exclusive use of laser and their association with fluoride varnish were similar to the exclusive use of fluoride. The association of fluoride varnish with laser shows better performance when the Nd: YAG laser is first used to varnish.
13

Avaliação do efeito do ácido zoledrônico na periodontite induzida em ratos: análise histológica e microtomográfica / Avaliação do efeito do ácido zoledrônico na progressão da doença periodontal em ratos: análise morfológica e microtomográfica

MARCELOS, Priscylla Gonçalves Correia Leite de 15 February 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-08T20:41:30Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Priscylla Gonçalves Correia Leite de Marcelos.pdf: 1912691 bytes, checksum: 75b6cc38aa3a5515bf5ed8df03dbc52c (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-16T22:53:15Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Priscylla Gonçalves Correia Leite de Marcelos.pdf: 1912691 bytes, checksum: 75b6cc38aa3a5515bf5ed8df03dbc52c (MD5) / Made available in DSpace on 2018-08-16T22:53:15Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Priscylla Gonçalves Correia Leite de Marcelos.pdf: 1912691 bytes, checksum: 75b6cc38aa3a5515bf5ed8df03dbc52c (MD5) Previous issue date: 2017-02-15 / CAPES / O objetivo neste trabalho foi avaliar a ação do ácido zoledrônico (zometa) na progressão da periodontite induzida em primeiros molares inferiores de ratos. Foram utilizados 48 ratos Wistar distribuídos aleatoriamente em 6 grupos experimentais (n=8 cada grupo), sendo 3 grupos expostos ao fármaco zometa (0,15mg/kg) e 3 grupos controles tratados com soro a 0,9%: Zom/Lig30 – animais expostos ao fármaco por 4 semanas com posterior indução da periodontite com de fio de sutura no último dia de droga e eutanásia 30 dias após a indução; Zom/Lig15 – grupo tratado por 4 semanas com posterior indução da periodontite no último dia de droga e eutanásia 15 dias após a indução; Lig/Zom – grupo no qual foi induzida a periodontite e 15 dias após, o zometa foi administrado por 8 semanas. A eutanásia ocorreu 1 semana após a última dosagem. Os grupos Con/Lig30, Com/Lig15 e Lig/Con, representam, respectivamente, os controles dos grupos citados acima. Após o sacrifício, as hemi-mandíbulas esquerdas foram removidas e avaliadas por meio de microtomografia computadorizada (μCT) e histometria. A perda óssea foi mensurada nas regiões de furca e raiz distal na microtomografia e na histometria. A presença da osteonecrose foi avaliada histologicamente. Os dados foram avaliados utilizando o teste t Student, para análise da microtomografia e Mann-Whitney para a histometria, ambos com nível de significância de 5%. Na histologia, foi possível evidenciar osteonecrose nos grupos Zom/Lig30, Zom/Lig15 e Con/Lig30. Na μCT, a raiz distal no grupo Lig/Con apresentou maior reabsorção comparado com o Lig/Zom (p<0,05). Na histometria, o osso alveolar da raiz distal apresentou maior reabsorção nos grupos Zom/Lig30 (p=0,005), Con/Lig15 (p<0,001) e Lig/com (p=0,001). Enquanto que a furca teve maior reabsorção nos grupos Zom/Lig30 (p=0,046) e no grupo Lig/Con (p<0,001). Conclui-se que o ácido zoledrônico diminui a reabsorção óssea alveolar em periodontite induzida em ratos tratados com a droga a longo prazo, além de apresentar o risco de desenvolver osteonecrose dos maxilares associados a bisfosfonatos na presença de trauma tecidual e infecção. / The aim of this study was to evaluate the action of zoledronic acid (zometa) on the progression of periodontitis induced in the lower first molars of rats. A total of 48 Wistar rats randomly distributed in 6 experimental groups (n = 8 each) were used. Three groups were exposed to drug zometa (0.15mg/kg) and three control groups treated with 0.9% serum: Zom/Lig30 - Animals exposed to the drug for 4 weeks with subsequent induction of periodontitis with suture wire on the last day of drug and euthanasia 30 days after induction; Zom/Lig15 - group treated for 4 weeks with subsequent induction of periodontitis on the last day of drug and euthanasia 15 days after induction; Lig/Zom - group in which periodontitis was induced and 15 days later, zometa was given for 8 weeks. Euthanasia occurred 1 week after the last dosing. The groups Con/Lig30, Con/Lig15 and Lig/Con, respectively, represent the controls of the groups mentioned above. After sacrifice, the left hemi-jaws were removed and evaluated by means of Computerized Microtomography (μCT) and histometry. Bone loss was measured in the furcation and distal root regions in microtomography and histometry. The presence of osteonecrosis was evaluated histologically. The data were evaluated using Student's t test for microtomography and Mann-Whitney for histometry, both with significance level of 5%. In histology, it was possible to show osteonecrosis in the Zom/Lig30, Zom/Lig15 and Con/Lig30 groups. In the μCT, the distal root in the Lig/Con group presented greater resorption compared to the Lig/Zom (p <0.05). In histometry, alveolar bone of the distal root presented greater resorption in the Zom/Lig30 (p = 0.005), Con/Lig15 (p <0.001) and Lig/Con (p = 0.001) groups. While the furca had greater resorption in the Zom/Lig30 groups (p = 0.046) and in the Lig/Con group (p <0.001). It is concluded that zoledronic acid decreases alveolar bone resorption in periodontitis induced in rats treated with the drug in the long term, and presents the risk of developing osteonecrosis of the maxilla associated with bisphosphonates in the presence of tissue trauma and infection.
14

Efeito do LED infravermelho sobre a movimentação dentária induzida em ratos / Infrared LED phototherapy effects on induced tooth movement in rats

Simone Peixe Friedrichsdorf 14 August 2015 (has links)
O LED infravermelho tem sido considerado uma alternativa efetiva para o laser na bioestimulação. Entretanto, o efeito na remodelação óssea durante o movimento ortodôntico ainda deve ser esclarecido. Oitenta ratos machos com 10 semanas de idade, foram divididos em dois grupos de 40 animais cada: grupo LED (GLED) e grupo controle (GCON), e tiveram seu 1ºmolar superior esquerdo submetido a força de 10 g com uma mola helicoidal fixada entre o 1ºmolar superior esquerdo e incisivo superior esquerdo. Durante os primeiros cinco dias de movimentação dentária foi aplicada a luz infravermelha LED (850nm, 30mW) durante 5 minutos no GLED. O GCON não foi irradiado. Em 0, 7, 14 e 21 dias, 5 animais de cada grupo foram submetidos a microtomografia computadorizada. Para a avaliação histológica, todos os ratos foram subdivididos em subgrupos de 20 animais cada de acordo com a o dia da eutanásia 4, 7, 14 e 21 dias e as maxilas foram dissecadas e processadas para a microscopia de luz (HE e TRAP). A quantidade de movimento, segundo as microtomografias computadorizadas, foi maior no grupo LED em T1 (intervalo entre os dias 0 e 7) e em T3 (intervalo entre os dias 14 e 21). No dia 4 foi observada hialinização na área de pressão em ambos os grupos; nos períodos posteriores, 7, 14, a área hialina foi vista apenas no grupo controle. A reabsorção radicular ocorreu em ambos os grupos após o dia 7. A fototerapia LED melhora a movimentação dentária e minimiza a hialinização durante o movimento ortodôntico. Entretanto, não reduz o risco de reabsorção da superfície radicular. / Infrared LED has been considered an effective alternative to infrared LASER for biostimulation purposes. However, its effect on bone remodeling during orthodontic tooth movement (OTM) is unknown. Eighty 10 week-old male Wistar rats were divided into two groups of forty animals each: LED group (GLED) and control group (GCON) and had a coiled spring bonded to the first upper molar and upper incisor exerting 10g force to mesially move the molar. During the first five days of OTM the maxillae were daily irradiated with infrared LED (850nm, 30mW) during 5 minutes (LED group). The controls were not irradiated (GCON). At 0, 7, 14 and 21 days, 5 LED group and 5 CON group rats were submitted to ?CT. For the histological study, all rats were subvided into subgroups of 20 animal each according to the euthanasia day 4, 7, 14 e 21 days. The rats were euthanized after 4, 7, 14 and 21 days and the maxillae were processed to light microscopy and TRAP histochemistry. The amount of tooth movement was greater in the GLED on days 7 and 14. At 4 day, hyalinization was seen at the pressure areas in both groups; on the subsequent days it was seen only in the GCON. Root resorption occurred in both groups after 7 days. LED phototherapy enhances early tooth movement and minimizes periodontal hyalinization during OTM. However, it does not reduce the risk of tooth resorption.
15

Avaliação da microarquitetura e resistência óssea em ratos submetidos à dieta diária de café e refrigerantes à base de cola e guaraná : Evaluation of microarchitecture and bone resistance in mice with daily diet of coffe and soft drinks based in coke and guarana / Evaluation of microarchitecture and bone resistance in mice with daily diet of coffe and soft drinks based in coke and guarana

Silva, Amaro Ilídio Vespasiano, 1985- 24 August 2018 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T19:04:20Z (GMT). No. of bitstreams: 1 Silva_AmaroIlidioVespasiano_D.pdf: 825243 bytes, checksum: 348fd72cdb122213d969293a350a2f66 (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi investigar e comparar os efeitos da dieta de café e refrigerantes à base de cola e guaraná sobre a microarquitetura e resistência óssea em ratos. Foram utilizados 80 ratos (Rattus norvegicus, Albinus Wistar), sendo 40 machos e 40 fêmeas, distribuídos em 8 grupos experimentais que receberam água (grupos controles), refrigerantes à base de cola, guaraná e café ad libitum. Ao término dos 48 dias de administração das substâncias, todos os animais foram sacrificados e o fêmur direito coletado para análise por microtomografia computadorizada e ensaio de resistência à flexão de três pontos. Após tabulação dos dados e análise estatística (ANOVA), foi observado alteração na microarquitetura óssea nos seguintes parâmetros analisados pela microtomografia computadorizada: volume de tecido (TV), volume ósseo (BV), superfície de tecido (TS), superfície óssea (BS), número de trabéculas ósseas (Tb.N), espessura das trabéculas ósseas (Tb.Th), volume de poros fechados (Po.V(cl)) e Volume de poros abertos (Po.V(op)) além de alterações na resistência óssea nas fêmeas. Concluiu-se que A ingestão das substâncias avaliadas causou alteração na microarquitetura óssea, levando a um aumento dos parâmetros de volume, tanto ósseo quanto de tecido. Porém, o consumo de refrigerante à base de guaraná e de café reduziram a microarquitetura trabecular; além disso, a ingestão de café e de refrigerante à base de cola aumentou o risco à fratura óssea nas fêmeas / Abstract: The aim of this study was to investigate and compare the effects of daily diet of coffee and soft drinks based in coke and guarana over the microarchitecture and bone strength in rats. 80 rats ( Rattus norvegicus, Albinus Wistar ) were used, 40 males and 40 females, divided into 8 experimental groups that received water (control groups), coke and guarana and coffe ad libitum. At the end of the 30 days of administration of substances, all animals were sacrificed and the right femur collected for analysis by computerized microtomography and testing flexion module of three points. After tabulating the data and statistical analysis (ANOVA), was observed changes in the bone microarchitecture in the following parameters assessed by computed microtomography: tissue volume (TV), bone volume (BV), tissue surface (TS), bone surface (BS), trabecular number (Tb.N), trabecular thickness (Tb.Th), volume of closed pores (Po.V(cl)) and volume of open pores (Po.V(op)), also changes in bone strength in females . It was concluded that ingestion of substances evaluated caused change in bone microarchitecture, leading to an increase in volume parameters, both bone as tissue. However, the consumption of coolant based on guarana and coffee reduced trabecular microarchitecture; Furthermore, ingestion of coffee and cola soft drink to increased risk of bone fracture in females / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
16

Caracterização físico, mecânica e de usinagem para compósitos MDF a base de fibras lignocelulosicas /

Bueno, Marcus Antonio Pereira. January 2019 (has links)
Orientador: Ivaldo De Domenico Valarelli / Coorientador: Eduardo Carlos Bianchi / Banca: Carlos Alberto Soufen / Banca: Maximiliano dos Anjos Azambuja / Banca: Elen Aparecida Martines Morales / Banca: Priscila Roel de Jesus / Resumo: O painel de fibras lignocelulósicas, constituído por fibras de madeiras como eucalipto e pinus, hoje em dia já é bastante utilizado na indústria moveleira, substituindo painéis de madeira serrada. Este trabalho foi desenvolvido com o objetivo de avaliar as potêncialidades da fibra de coco aos painéis de MDF (Médium Density Fiberboard) de eucalipto, afim de viabilizar sua utilização na indústria moveleira e construção civil. Para tanto, foram estudadas as propriedades físicas e mecânicas desse novo painel, segundo recomendação da NBR 15.316-2 (2015), e realizados ensaios de caracterização das fibras, ensaio de densitometria por raios-x para avaliar e caracterizar o perfil e densidade dos painéis; ensaio de micro tomografia para avaliar a estrutura e arranjo do painel a fim de verificar a densidade e entrelaçamento entre as duas fibras, espalhamento da resina e possíveis defeitos ocultos nos painéis, ensaio de usinagem para medir a potência consumida na operação de fresamento tangencial e medição da rugosidade média (Ra) e da rugosidade total (Rt). A densidade alvo ficou dentro da margem de 700 kg/m³, o que o define como painel de média densidade. Foram produzidos painéis contendo 5 traços diferentes, sendo o primeiro com 100% fibras de eucalipto (T1), o segundo 80% fibras de eucalipto e 20% fibras de coco (T2), o terceiro 60% fibras de eucalipto e 40% fibras de coco (T3), o quarto 40% fibras de eucalipto e 60% fibras de coco (T4) e o quinto traço (T5) denominado comercial foi ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Lignocellulosic fiberboard, made up of wood fibers such as eucalyptus and pine, is now widely used in the furniture industry, replacing lumber panels. This work was developed with the objective of evaluating the potential of coconut fiber to eucalyptus MDF (Medium Density Fiberboard) panels, in order to enable its use in the furniture industry and civil construction. For this purpose, the physical and mechanical properties of this new panel were studied, according to the recommendation of NBR 15.316-2 (2015), and carrie out fiber characterization tests, X-ray densitometry test to evaluate and characterize the profile and density of the panels; micro tomography test to evaluate the structure and arrangement of the panel in order to verify the density and interlacing between the two fibers, resin scattering and possible hidden defects in the panels, machining test to measure the power consumed in the operation of tangential milling and measurement of mean roughness (Ra) and total roughness (Rt). The target density was within the range of 700 kg/m³, which defines it as a medium density panel. Panels were produced with 5 different traits, the first with 100% eucalyptus fibers (T1), the second 80% eucalyptus fibers and 20% coconut fibers (T2), the third 60% eucalyptus fibers and 40% coconut fibers (T3), the fourth 40% eucalyptus fibers and 60% coconut fibers (T4) and the fifth trace (T5) called commercial was acquired in Bauru's trade. The amount of adhesive used based on urea formaldehyde was 10% of the total mass of the dry material. All the results obtained were evaluated and the results of the acquisitions were statistically treated to define which traits and adhesions of the coconut and eucalyptus fibers fall within the standardization and current norms for MDF. For the physical tests, the addition of coconut fibers worsened the quality of the panel, and in general the trace T4 was the one that obtained t / Doutor
17

Avaliação e qualificação do uso de tomografia de raios-x no acompanhamento do processamento de compósitos híbridos CRFC/SiC /

Souza, Maria Aparecida Miranda de. January 2019 (has links)
Orientador: Michelli Leali Costa / Corientador: Edson Cocchieri Botelho / Banca: Ronaldo Spezia Nunes / Banca: Luis Rogério de Oliveira Hein / Banca: Antonio Carlos Ancelotti Junior / Banca: Evandro Luis Nohara / Resumo: Compósitos de carbono reforçados com fibra de carbono (CRFC) e compósitos híbridos de carbono e carbeto de silício reforçados com fibra de carbono (CRFC/SiC) são materiais de grande interesse na indústria aeroespacial devido principalmente às suas excelentes propriedades termomecânicas a altas temperaturas. O controle do processo de obtenção desses compósitos realizados por técnicas não destrutivas, tais como a tomografia de raios-X podem apresentar não somente informações relativas à massa específica e porosidade, mas também visão 3D com identificação de poros abertos e fechados e a localização precisa destes e outros defeitos na amostra. Neste estudo, um compósito de matriz híbrida CRFC/SiC, obtido por uma rota alternativa de preparação, baseada em reação de carbono-silício por impregnação direta de silício em pó disperso em resina fenólica, seguido de tratamentos térmicos consecutivos a 1000°C e 1600°C sob atmosfera inerte, teve seu processo reacional monitorado passo a passo, em seus estágios de preparação utilizando difração de raios-X. O desenvolvimento do estudo morfológico do compósito resultante foi realizado utilizando-se duas técnicas de tomografia computadorizada comparativamente à microscopia óptica, sendo esta última técnica já consolidada em trabalhos anteriores, com foco em detecção e quantificação de defeitos. Os três métodos apresentados demonstraram informações satisfatórias para a análise estrutural das etapas de obtenção do compósito CRFC/SiC. A utilizaçã... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Carbon fiber reinforced carbon composites (CFRC) and carbon fiber reinforced carbon and silicon carbide hybrid composites (CFRC/SiC) are materials of great interest in the aerospace industry due mainly to their excellent thermomechanical properties at high temperatures. Controlling the process of obtaining these composites performed by non-destructive techniques such as X-ray tomography can present not only information regarding density and porosity, but also 3D vision with identification of open and closed pores and their precise location and other defects in the sample. In this study, a CFRC/SiC hybrid matrix composite, obtained by an alternative preparation route, based on carbon-silicon reaction by direct impregnation of silicon powder dispersed in phenolic resin, followed by consecutive heat treatments at 1000°C and 1600°C under an inert atmosphere, the reaction process was monitored step by step in its preparation stages using X-ray diffraction. The development of the morphological study of the resulting composite was performed using two computed tomography techniques compared to optical microscopy, the latter technique already consolidated in previous works, focusing on detection and quantification of defects. The three methods presented demonstrated satisfactory information for the structural analysis of the steps of obtaining the CRFC/SiC composite. The use of X-ray microtomography with 7.4 µm voxel allowed, besides the detection and quantification of pore-related de... (Complete abstract click electronic access below) / Doutor
18

Avaliação da plataforma tri-channel por meio de microtomografia computadorizada e suas propriedades mecânicas após torque de inserção, fadiga e fratura / Tri-channel platform evaluation by computerized microtomography and its mechanical properties after insertion torque, fatigue and fracture

Morais, Renata Costa de 26 October 2018 (has links)
Para avaliação das propriedades físico-mecânicas de implantes tri-channel Dérig, quanto ao efeito de acréscimo de 0,25mm no corpo do implante 3.5 NP (em relação ao controle 3.5 NP) e à influência da plataforma switching (em diâmetros iguais de 4,3 mm e plataformas distintas - NP e RP), o presente estudo relacionou resistência ao torque de inserção (avaliação do microgap entre implante/pilar protético - mensurações bi e tridimensionais), em microtomografia computadorizada (CT); resistência à fratura e resistência à fadiga. Para a resistência ao torque de inserção, os implantes foram divididos, aleatoriamente, em quatro subgrupos (n=10), segundo torque: GT45: 45 N.cm; GT80: 80 N.cm; GT120: 120 N.cm; GT150: 150 N.cm. Os conjuntos implante/pilar/parafuso foram levados às análises de deformação bi e tridimensional em CT. Para o teste de resistência à fratura, os conjuntos implantes/munhões foram levados à máquina de ensaios universais, até a falha e, posteriormente, às microscopias óptica e eletrônica de varredura. Para a resistência à fadiga, os conjuntos (n=12) foram submetidos a ensaio cíclico (5 Hz, 5° - 55° C, cargas em 80, 120, 160, 200, 240, 280 e 320 N, máximo de 2x104 ciclos) e carregados até a falha (ou máximo de 14x104 ciclos) (análise de sobrevivência Life Table Survival Analysis). Para o envelhecimento mecânico, os conjuntos (n=12) foram submetidos a 106 ciclos (2 Hz, 120 N, 5º - 55º C) e, novamente, levados às análises microscópicas. Após a análise estatística (2-way ANOVA, Bonferroni, p<0,05), para a análise da porcentagem de deformação bi e tridimensional dos torques de inserção em CT, há diferenças significantes (p<0,05) em todas as comparações, à exceção de 4.3 NP x 4.3 RP (45N). As microtomografias evidenciaram microgaps em conjuntos novos e aumento, qualitativo, dos mesmos, em diâmetros e plataformas menores. A comparação linear com conjuntos novos demonstrou diferenças significantes (p<0,05) em 3.5 NP e 3.75 NP (todos os torques) e 4.3 NP (120 e 150 N.cm). Para o ensaio de resistência à fratura (1-way ANOVA, Tukey B, p<0,05), 4.3 NP apresentou força máxima de deformação maior (p<0,05) que 3.75 NP e 3.5 NP (p=0,004), mas não houve diferença significante entre 4.3 RP, 3.5 NP e 3.75 NP (p>0,05). Quanto aos ensaios de resistência à fadiga, o envelhecimento mecânico levou ao afrouxamento dos parafusos de todos os grupos analisados, sendo que, à exceção de 3.75 NP, houve diferenças significativas (p<0,05) entre perdas de torques inicial e final; para a fadiga acelerada, ambos os grupos de 4,3 mm (NP e RP) sobreviveram ao final do ensaio, sendo que houve fratura de todas as amostras de 3.5 NP. Finalmente, quanto à probabilidade de sobrevivência, houve diferença significante (p<0,05) entre 3.5 NP e 3.75 NP, com taxa de 92% para este último. Conclui-se que o diâmetro 4,3 mm é mais resistente que 3,5 mm; 4.3 NP apresentou maior resistência à fratura; o envelhecimento mecânico leva à perda de torque; a fadiga mecânica acelerada tem influência em diâmetros menores e a metodologia em CT é válida para análises bi e tridimensional / To investigate the physical-mechanical properties of Dérigs tri-channel implants, regarding the 0.25 mm addition in 3.75 NP implant structure (in relation to 3.5 NP as control) and the influence of platform switching (in equal diameters of 4.3 mm and different platforms - Narrow and Regular), this study related the resistance to insertion torque (microgap evaluation between implant and abutment - bi and tridimensional measurements), computerized microtomography (CT); resistance to fracture and fatigue. For the resistance to insertion torque, the samples were randomly divided into four subgroups (n=10), according to the torque applied: GT45: 45 N.cm; GT80: 80 N.cm; GT120: 120 N.cm; GT150: 150 N.cm. The implant/abutment/screw assemblies were taken to bi and tridimensional deformation analyzes in CT. For the fracture strength test, the implant/abutment assemblies were taken to the universal test machine until failure and then to optical and scanning electron microscopes. For the fracture resistance, the sets (n=12) were subjected to a cyclic test (5 Hz, 5° - 55° C, loads in 80, 120, 160, 200, 240, 280 and 320 N, maximum of 2x104 cycles) and loaded to failure (or maximum of 14x104 cycles) (Life Table Survival Analysis). For mechanical aging, the sets (n=12) were submitted to 106 cycles (2 Hz, 120 N, 5º - 55º C) and, again, to microscopic analysis. After statistical analysis (2-way ANOVA, Bonferroni, p<0.05), there were statistical differences (p<0.05) in all comparisons for the bi and three-dimensional deformation percentages of the insertion torques in CT, except between 4.3 NP x 4.3 RP (45N). The microtomographies evidenced microgaps in new sets and a qualitative increase of the same sets in diameters and smaller platforms. The linear comparison with new sets showed significant differences (p<0.05) in 3.5 NP and 3.75 NP (all torques) and 4.3 NP (120 and 150 N.cm). As for the fracture resistance test (1-way ANOVA, Tukey B, p<0.05), 4.3NP had a higher maximum deformation force (p<0.05) than 3.75 NP and 3.5NP (p=0.004), but there was no significant differences between 4.3 RP, 3.5 NP and 3.75 NP (p>0.05). Regarding the fatigue strength tests, the mechanical aging led to the screw loosening of all groups analyzed, and by the exception of 3.75 NP, there were significant differences (p<0.05) between initial and final torque applied; for the accelerated fatigue, both groups of 4.3 mm (NP and RP) survived at the end of the test, with fractures in all 3.5 NP samples. Finally, regarding the survival rate, there was a significant difference (p<0.05) between 3.5 NP and 3.75 NP, with a 92% rate for this last one. It could be concluded that the diameter 4.3 mm is stronger than 3.5 mm; 4.3 NP presented higher fracture resistance; the mechanical aging leads to screw loosening; the accelerated mechanical fatigue has influence in smaller diameters and the methodology in CT is valid for bi and three-dimensional analyzes
19

Eficácia de remoção da medicação intracanal de hidróxido de cálcio com o uso do ultrassom associado ou não ao instrumento adicional, avaliada através da microtomografia computadorizada / Effectiveness of intracanal calcium hydroxide removal with the use of ultrasound with or without an additional instrument, evaluated by computed microtomography

Silva, Luciana Jorge Moraes 02 September 2013 (has links)
Objetivos: avaliar a eficácia do uso da irrigação ultrassônica passiva (IUP), do instrumento adicional e da associação de ambos na remoção da medicação intracanal de hidróxido de cálcio através da microtomografia computadorizada (micro-CT). Material e métodos: foram selecionados 32 dentes humanos unirradiculares, preparados pela técnica de instrumentação rotatória com o sistema Protaper® universal até a lima final Finishing File 4 (F4). As amostras foram preenchidas com medicação intracanal de Ca(OH)2 associada ao propilenoglicol 400. Após 30 dias, os dentes foram divididos em quatro grupos, de acordo com a técnica de remoção da medicação. Nos grupos em que foi utilizada a IUP, esta foi realizada através da irrigação-aspiração com 5 mL de NaOCl 1%, 3 mL de EDTA 17% com agitação ultrassônica por um minuto a 2 mm do CRT e 5 mL de NaOCl 1%. O instrumento adicional utilizado foi a lima F5. No grupo controle, a remoção da medicação foi feita apenas com o instrumento final (F4) e com o uso do EDTA 17%, mantido por um minuto no interior do canal, sem ativação ultrassônica. As amostras foram avaliadas por meio da micro-CT, em três momentos distintos do procedimento endodôntico: 1) após preparo químico-cirúrgico do canal, 2) 30 dias após aplicação da medicação intracanal de Ca(OH)2 e 3) após remoção da medicação intracanal. As imagens microtomográficas foram avaliadas utilizando o software CTan (SkyScan). O canal foi dividido em terços apical, médio e cervical. Os conjuntos de dados foram analisados usando a escala de cinza do software CTan para quantificar o volume (em mm3) do canal após o preparo, o volume da medicação após 30 dias, o volume de resíduos de medicação e o volume do canal após remoção da medicação. A porcentagem de resíduos também foi calculada em relação ao volume do canal e ao volume de medicação após 30 dias. Finalmente, o aumento de volume do canal após a remoção também foi avaliada. Os dados foram analisados através de ANOVA de três fatores/teste de Tukey ou Kruskal-Wallis/Student-Newman-Keuls, com nível global de significância de 5%. Resultados: Independentemente da região do canal, o uso do ultrassom resultou em um menor volume de resíduos de MIC, em termos absolutos e em relação ao volume do canal. Em relação ao volume de medicação após 30 dias, o uso do ultrassom foi marginalmente significante. O uso do instrumento adicional não apresentou influência significante sobre a eficácia da remoção da MIC. A porcentagem de resíduos foi maior na região apical, quando o ultrassom não foi utilizado. Em números absolutos, a região cervical apresentou maior volume de resíduos. Em relação ao grupo controle, o uso do ultrassom resultou em um volume final maior do canal cirúrgico no terço cervical. Em termos percentuais, todas as técnicas resultaram em aumentos estatisticamente semelhantes do volume do canal cirúrgico para os terços cervical e médio. No terço apical, o grupo controle apresentou aumento percentual estatisticamente inferior aos demais. Conclusões: houve diferenças estatisticamente significantes na eficácia de remoção da MIC entre as técnicas testadas, sendo que o uso do ultrassom resultou em um menor volume de resíduos de MIC, em todos os grupos para um dado terço. / Objectives: To evaluate the efficacy of passive ultrasonic activation (PUI), an additional instrument and the combination of both for removal of intracanal calcium hydroxide using computerized microtomography (micro-CT). Methods: 32 singlerooted human teeth were prepared using the universal Protaper® rotary instrumentation system, with Finishing File 4 (F4) as the final file. The samples were filled with intracanal Ca(OH)2 plus propyleneglycol 400. After 30 days, the samples were divided into four groups according to the medication removal technique. In the groups where PUI was used, it was done by suction-irrigation with 5 mL of 1% NaOCl, 3 ml 17% EDTA with ultrasonic agitation for one minute at 2 mm from the working length and 5 ml of 1% NaOCl. The additional instrument used was the F5 file. In the control group, removal of the medication was performed only with the final instrument (F4) and using 17% EDTA, kept for one minute in the canal without ultrasonic activation. The samples were evaluated by micro-CT, at three different stages of the endodontic procedure: 1) after chemical-surgical preparation of canal 2) 30 days after application of the Ca(OH)2 medication 3) after removal of the medication. Microtomography images were evaluated using the CTan (SkyScan) Software. The root was divided in apical, middle and cervical. Each data set was analyzed using the CTan software gray scale to determine the volume (mm3) of the canal after the preparation, the volume occupied by the medication after 30 days, the medication residue volume and the volume of the canal after medication removal. The residue percentage was also calculated in relation to the volume of the canal and the volume of medication found after 30 days. Finally, the volume increase of the canal after medication removal was also assessed. Data were analyzed using threefactor ANOVA/Tukey test or Kruskal-Wallis/Student-Newman-Keuls with overall significance level of 5% Results: Regardless of the region, the use of ultrasound resulted in a smaller volume of residue in absolute terms and in relation to the volume of the canal. In relation to the volume of medication after 30 days, the use of ultrasound was only marginally significant. The use of an additional instrument showed no statistically significant influence on the effectiveness of MIC removal. The percentage of residue was higher in the apical region, when the ultrasound was not used. In absolute numbers, the cervical region showed the highest volume of residue. In relation to the control group, the use of ultrasound resulted in a higher final volume in the cervical third. All techniques resulted in statistically similar increases in the volume of the surgical canal for the cervical and middle thirds. In the apical third, the control group showed a statistically lower increase in volume than the others thirds. Conclusions: Statistically significant differences were found among the tested techniques, the use of ultrasound resulted in a smaller volume of residue in all groups for a particular third.
20

Avaliação por microtomografia de raio-X do reparo ósseo em osteotomia completa de tíbia de ratos após tratamento com ultrassom de baixa intensidade e laser de baixa potência / Assessment of bone repair by x-ray microtomography in complete Tiba rats osteotomy after low-intensity pulsed ultrasound and low-level laser therapy

Paolillo, Alessandra Rossi 12 December 2013 (has links)
As fraturas são consideradas um dos maiores problemas de saúde pública pelo custo e morbidade a elas associados. O objetivo deste estudo foi investigar os efeitos do ultrassom de baixa intensidade (LIPUS) e do laser de baixa potência (LLLT) sobre o reparo ósseo de tíbia de ratos (Wistar) utilizando a microtomografia por raio-x (&#956CT) e a análise histomorfométrica. Uma osteotomia total no terço médio foi fixada com fio de Kirschner (0,89 mm) e utilizado um espaçador polimérico de 2 mm de espessura e 1 mm de diâmetro entre os fragmentos proximal e distal para induzir retardo de consolidação da fratura. Foram utilizados 24 animais separados aleatoriamente em 4 grupos experimentais: Grupo Controle: sem tratamento do retardo da consolidação (n = 5); Grupo Laser: tratamento da fratura com laser (n = 6); Grupo LIPUS: tratamento da fratura com LIPUS (n = 7) e; Grupo LIPUS + Laser: tratamento da fratura com LIPUS e Laser (n = 7). Os tratamentos com LIPUS e/ou Laser foram iniciados após 5 semanas da cirurgia e realizados durante 5 dias consecutivos de tratamento, seguidos por 2 dias sem serem tratados até totalizarem 12 sessões terapêuticas. Os parâmetros de irradiação laser foram: 808 nm; 100 mW; 2500 mW/cm² , 125 J/cm² durante 50 segundos. Os parâmetros do LIPUS foram: 1,5 MHz, ciclo de trabalho 1:4, intensidade de 30 mW/cm², 20 minutos por sessão. Quando as duas técnicas foram associadas, o laser foi aplicado perpendicularmente ao LIPUS no décimo minuto de aplicação do LIPUS. Radiografias da tíbia foram feitas para acompanhar a evolução da fratura após a cirurgia, antes dos tratamentos e antes da eutanásia. Após a eutanásia foram realizadas avaliações microtomográficas por raio-x e histomorfométricas para análise do reparo ósseo. Na análise microtomográfica do reparo ósseo o tecido neoformado de reparo (calo ósseo) e o tecido normal não foram isolados. Na análise estatística foi utilizada a ANOVA one-way com posthoc de Tukey. Não foi constatada diferença significativa para maioria das variáveis, exceto para o fator padrão trabecular (Tb.Pf) no grupo LIPUS+Laser comparado aos grupos LIPUS (p = 0.02), Laser (p = 0.02) e Controle (p = 0.01), para a conectividade (Conn) no grupo Laser comparada ao grupo Controle (p = 0.04) e para a densidade de conectividade (D.Conn) no grupo LIPUS+Laser comparado ao grupo Controle (p = 0.04). As imagens histológicas mostram maior quantidade de tecido esponjoso no grupo LIPUS+Laser. Parâmetros morfométricos e histomorfométricos não revelaram um avanço do reparo ósseo na comparação entre os grupos com tratamento em relação ao grupo controle provavelmente devido a não reabsorção do espaçador polimérico pelo organismo dos animais. A &#956CT é uma técnica de grande potencial que permite análises qualitativas e quantitativas e reconstruçoes 2D e 3D. / Bone fractures are important public health problems due to the morbidity and high cost related to them. The aim of this study was to evaluate the effects of low pulsed intensity ultrasound (LIPUS) and infrared low level laser therapy (LLLT) in the bone repair of a transverse rat tibia osteotomy with assessement by x-ray microtomography (&#956CT) and histomorphometry. An easily implemented transverse osteotomy with a Kirchner wire and 2 mm width polymeric spacer beads established a delayed union in the fracture. Twenty four rats were divided into four experimental groups: Control Group - untreated; Laser Group - treated with infrared LLLT; LIPUS Group treated with low intensity pulsed ultrasound; LIPUS+Laser Group - treated with low intensity pulsed ultrasound and infrared LLLT. The treatments with infrared LLLT (808 nm, 100 mW, 2500 mW/cm², 125 J/cm², 50 seconds) and LIPUS (1,5 MHz, 1:4 duty cicle, 30 mW/cm², 20 minutes) started 5 weeks after the surgery following a sequence of 5 days on and 2 days off until 12 sessions were reached. When LLLT and LIPUS therapies were used simultaneously there was a 90º angle between the laser and the ultrasound beams. The surgical technique and the bone repair were assessed by x-ray radiography. One-way analysis of variance (one-way ANOVA) and Tukey post-hoc were used for statistical analysis. The normal bone and the callus were kept together in the &#956CT analysis. There was no significant difference between treatments results except for the parameters trabecular pattern factor - Tb.Pf [US+Laser group x LIPUS group (p = 0.02); US+Laser group x Laser group (p = 0.02) and US+Laser group x Control group (p = 0.01)], connectivity - Conn [Laser group x Control group (p = 0.04)] and connectivity density D.Conn [US+Laser group x Control group (p = 0.04)]. The histology showed greater amount of spongeous bone in the LIPUS+Laser group. The morphometric and histomorphometric assessments didn´t show a faster bone repair when treated groups were compared against the control one. The non absorption of the polymeric spacer bead is probably the reason of these findings. The &#956CT is a powerful technique that allows 2D and 3D quantitative analysis and reconstructions.

Page generated in 0.0641 seconds