• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uso da microtomografia computadorizada na análise da lesão periapical em animais de pequeno porte : revisão sistemática da literatura e estudo in vivo /

Kalatzis-Sousa, Natalia Guimarães. January 2016 (has links)
Orientador: Gisele Faria / Resumo: Os objetivos do presente estudo foram: Publicação 1 - Realizar uma revisão sistemática sobre os parâmetros microtomográficos de aquisição, reconstrução e análise da lesão periapical (LP) em ratos e camundongos. Além disso, ilustrar o efeito da variação destes parâmetros (tamanho do voxel, beam hardening correction, smoothing, gray dataset, plano de orientação, região de interesse - ROI e threshold) em imagens microtomográficas de hemimandíbulas com LP induzida em molares inferiores de camundongos; e Publicação 2 - Avaliar a acurácia da microtomografia computadorizada (micro-CT) na análise de LP induzida em dentes de camundongos empregando como padrão ouro para comparação os valores obtidos por estereologia aplicada a dados histológicos. Na Publicação 1, foram pesquisados artigos que usaram a micro-CT para avaliar LP em ratos e camundongos de 2000 a janeiro de 2015 no PubMed. Para a ilustração dos efeitos da variação dos parâmetros de aquisição, reconstrução e análise da LP foram utilizadas mandíbulas de camundongos que tiveram LP induzida nos primeiros molares inferiores. Foram encontrados 21 artigos. Destes, 18 citaram algum parâmetro usado na aquisição, nenhum descreveu os parâmetros de reconstrução e 16 citaram alguns parâmetros de análise da LP. Nenhum artigo relatou o protocolo completo para aquisição, reconstrução e avaliação da LP. Nenhum artigo foi classificado como alta qualidade, 7 foram como moderada qualidade e 14 de baixa. A ilustração da variação dos parâmetros ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objectives of this study were: Publication 1 - Perform a systematic review of the microtomographic parameters of acquisition, reconstruction and analysis of periapical lesion (LP) in rats and mice. In addition, to illustrate the effect of the variation of these parameters (voxel size, beam hardening correction, smoothing, gray dataset, orientation plane, region of interest - ROI and threshold) in microtomographic pictures of hemimandibles with LP induced in lower molars of mouse; and Publication 2 - Evaluate the accuracy of computed microtomography (micro-CT) in the analysis of LP induced in teeth of mouse employing as the gold standard for comparing the values obtained by stereology applied to histological data. In Publication 1, were researched papers that used micro-CT to evaluate LP in rats and mouse from 2000 to January 2015 in PubMed. To illustrate the effect of variations in acquisition-, reconstruction-, and analysis parameters on images of LP were used mouse's jaws that had LP induced in the lows first molars. 21 articles were found. Of these, 18 cited a parameter used in the acquisition, none described the reconstruction parameters and 16 cited some of the LP analysis parameters. No article reported the complete protocol for acquisition, reconstruction and analysis of LP. No study was classified as high seven were classified as moderate-, and 14 as low quality. The effect of variation in parameters was that voxel size may interfere with image sharpness and reconstruction may interfere with image sharpness. The inadequate plane orientation may alter the size of the LP. Nonpersonalized ROIs select the regions beyond the LP and the personalized selects only the lesion. The increase of the threshold values increased the lesion. It was concluded that no defined protocol for acquiring and analyzing micro-CT images of LP in rats...(Complete abstract electronic sccess below) / Doutor
2

Caracterização de concreto reforçado com fibras pela técnica de microtomografia computadorizada por transmissão de raios X / Characterization of fiber reinforced concrete by the technique of computed microtomography X ray transmission

Átila Sala Bourguignon 05 August 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesta dissertação de Mestrado do programa de Pós-Graduação em Ciência e Tecnologia dos Materiais é apresentado um estudo para a caracterização do concreto reforçado com fibras de polipropileno e de aço pela análise das imagens de microtomografia computadorizada por transmissão de raios X (μCT). Foram produzidos corpos de prova de concreto para determinar a sua resistência mecânica à compressão. As imagens foram obtidas no sistema Skyscan, modelo 1174, reconstruídas e analisadas. Foi possível observar na análise das imagens a estrutura da fibra de aço dispersa na matriz do concreto e quantificá-las pelo programa de análise de imagens Ctan e perceber um ganho na resistência mecânica em relação ao concreto sem fibras. Não foi feito a quantificação das amostras de fibras de polipropileno dispersas na matriz de concreto, mas foi observada a presença de aglomerados dessa fibra que resultaram na perda da resistência mecânica em relação ao concreto sem fibras. / In this dissertation Masters Program Graduate in Science and Technology of Materials is presented a study for characterization of concrete reinforced with polypropylene fibers and steel by image analysis of computed microtomography X ray transmission (μCT). Concrete samples were produced to determine their mechanical resistance to compression. The images were obtained in the SkyScan model 1174, reconstructed and analyzed. It was possible, in image analysis, to observe the structure of steel fiber dispersed in the concrete matrix and quantify them by image analysis program Ctan and observed a gain in strength compared to concrete fiber less. The quantification was not did to samples of polypropylene fibers dispersed in the matrix of concrete, but we observed the presence of clusters fibers resulting in the loss of mechanical strength compared to concrete fiber less.
3

Caracterização de concreto reforçado com fibras pela técnica de microtomografia computadorizada por transmissão de raios X / Characterization of fiber reinforced concrete by the technique of computed microtomography X ray transmission

Átila Sala Bourguignon 05 August 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Nesta dissertação de Mestrado do programa de Pós-Graduação em Ciência e Tecnologia dos Materiais é apresentado um estudo para a caracterização do concreto reforçado com fibras de polipropileno e de aço pela análise das imagens de microtomografia computadorizada por transmissão de raios X (μCT). Foram produzidos corpos de prova de concreto para determinar a sua resistência mecânica à compressão. As imagens foram obtidas no sistema Skyscan, modelo 1174, reconstruídas e analisadas. Foi possível observar na análise das imagens a estrutura da fibra de aço dispersa na matriz do concreto e quantificá-las pelo programa de análise de imagens Ctan e perceber um ganho na resistência mecânica em relação ao concreto sem fibras. Não foi feito a quantificação das amostras de fibras de polipropileno dispersas na matriz de concreto, mas foi observada a presença de aglomerados dessa fibra que resultaram na perda da resistência mecânica em relação ao concreto sem fibras. / In this dissertation Masters Program Graduate in Science and Technology of Materials is presented a study for characterization of concrete reinforced with polypropylene fibers and steel by image analysis of computed microtomography X ray transmission (μCT). Concrete samples were produced to determine their mechanical resistance to compression. The images were obtained in the SkyScan model 1174, reconstructed and analyzed. It was possible, in image analysis, to observe the structure of steel fiber dispersed in the concrete matrix and quantify them by image analysis program Ctan and observed a gain in strength compared to concrete fiber less. The quantification was not did to samples of polypropylene fibers dispersed in the matrix of concrete, but we observed the presence of clusters fibers resulting in the loss of mechanical strength compared to concrete fiber less.
4

Characterisation of the Filler Fraction in CAD/CAM Resin-Based Composites

Koenig, Andreas, Schmidtke, Julius, Schmohl, Leonie, Schneider-Feyrer, Sibylle, Rosentritt, Martin, Hoelzig, Hieronymus, Kloess, Gert, Vejjasilpa, Ketpat, Schulz-Siegmund, Michaela, Fuchs, Florian, Hahnel, Sebastian 05 May 2023 (has links)
The performance of dental resin-based composites (RBCs) heavily depends on the characteristic properties of the individual filler fraction. As specific information regarding the properties of the filler fraction is often missing, the current study aims to characterize the filler fractions of several contemporary computer-aided design/computer-aided manufacturing (CAD/CAM) RBCs from a material science point of view. The filler fractions of seven commercially available CAD/CAM RBCs featuring different translucency variants were analysed using Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray Spectroscopy (EDS), Micro-X-ray Computed Tomography (µXCT), Thermogravimetric Analysis (TG) and X-ray Diffractometry (XRD). All CAD/CAM RBCs investigated included midifill hybrid type filler fractions, and the size of the individual particles was clearly larger than the individual specifications of the manufacturer. The fillers in Shofu Block HC featured a sphericity of ≈0.8, while it was <0.7 in all other RBCs. All RBCs featured only X-ray amorphous phases. However, in Lava Ultimate, zircon crystals with low crystallinity were detected. In some CAD/CAM RBCs, inhomogeneities (X-ray opaque fillers or pores) with a size <80 µm were identified, but the effects were minor in relation to the total volume (<0.01 vol.%). The characteristic parameters of the filler fraction in RBCs are essential for the interpretation of the individual material’s mechanical and optical properties.

Page generated in 0.0709 seconds