• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • Tagged with
  • 9
  • 9
  • 9
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Surgical treatment of mitral stenosis.

Baden, Helge, January 1958 (has links)
Afhandling--Copenhagen. / Summary also in Danish. Bibliography: p. 253-258.
2

Surgical treatment of mitral stenosis.

Baden, Helge, January 1958 (has links)
Afhandling--Copenhagen. / Summary also in Danish. Bibliography: p. 253-258.
3

Closed mitral valvotomy in pregnancy

Vosloo, S M 31 March 2017 (has links)
Heart disease remains the most important non-obstetric cause of maternal mortality and morbidity during pregnancy, despite its low incidence of less than 1%. This is due to the decline in the number of deaths from haemorrhage, infection and toxemia. In addition, a striking change in the pattern of proportional distribution of organic heart disease in pregnant women is being noted, with a decrease in chronic rheumatic lesions and an increase in congenital cardiac disease. In the Third World rheumatic mitral valve disease remains a most important condition during pregnancy. It is currently rarely seen in Europe and the United States. Mitral stenosis is the most commonly encountered rheumatic heart lesion that complicates pregnancy. The normal circulatory changes during pregnancy aggravate this lesion as the reduced, fixed valve area obstructs blood flow from the left atrium to the left ventricle, causing pulmonary congestion and oedema. Careful and regular follow up of these patients is essential, and surgery is indicated if optimal medical management fails. Cardiac surgery duting pregnancy represents a risk to both the foetus and the mother. For most procedures extracorporeal circulation and heparinization are necessary and adds to the · adverse effects of the operation. Closed mitral valvotomy, however, is an excellent low risk operative procedure in patients with tight mitral stenosis without causing undue harm to the foetus. Cuttler described the first attempted surgery of the mitral valve in 1923 and since then the procedure has been improved to benefit many patients with tight mitral stenosis. The first reports of closed mitral valvotomy during pregnancy were in 1952. Al though a more precise valvotomy can be obtained with an open procedure, the closed operation avoids the risks of extracorporeal circulation, particularly detrimental to the foetus. This report is a review of the Groote Schuur Hospital experience of patients with mitral stenosis requiring closed mitral valvotomy during pregnancy since 1965. The aims of the study are to analyse the outcome of the pregnancy, the effects of valvotomy during pregnancy on both the mother and the foetus, and the outcome regarding restenosis of the mitral valve.
4

Balloon mitral valvuloplasty at Groote Schuur Hospital : results, complications and short-term follow-up

Lawrenson, John Bernard 06 April 2017 (has links)
Balloon dilatation of the stenosed mitral valve, in an attempt to relieve symptoms, was developed to replace the surgical procedure of closed mitral valvotomy. This procedure, whereby a balloon tipped catheter is introduced from the femoral vein and directed across the mitral valve after an atrial septal puncture, was developed in 1982. The procedure was first performed at Groote Schuur Hospital in 1988. Two types of dilating balloon (Inoue and Bifoil types) have been used. The aim of this retrospective study was to analyze the results of balloon mitral valvuloplasty procedures performed from 1988 until November 1992. In addition a detailed analysis was made of all complications of the procedure. 118 patients (mean age 30.7 years) underwent 124 attempted procedures. 93 % of attempts were successfully completed and an optimal result was achieved in 76% of patients. Mitral valve area increased from 0.9cm² to 2.0cm². Equivalent results have been achieved with both balloon types. Death occurred in 1.6 % of patients. 2.4 % of patients had severe mitral regurgitation as a complication. 4% of procedures resulted in cardiac chamber perforation. The experience at Groote Schuur has been similar to other centres treating young patients with rheumatic mitral stenosis.
5

Efeitos hemodinâmicos da ventilação não invasiva com pressão positiva em pacientes com estenose mitral sintomática / Hemodynamic effects of positive pressure noninvasive ventilation in patients with symptomatic mitral stenosis

Bento, Andre Moreira 27 March 2008 (has links)
Introdução: O uso de pressão positiva contínua em vias aéreas (CPAP) causa modificações hemodinâmicas favoráveis em pacientes com insuficiência cardíaca. Na presença de disfunção ventricular esquerda, mecanismos hemodinâmicos propostos associam seu uso ao aumento do débito cardíaco, através da redução do enchimento e da pressão transmural do ventrículo esquerdo. Estes efeitos talvez colaborem para o sucesso dessa terapia em pacientes com congestão pulmonar. Entretanto, até onde extensa revisão bibliográfica nos permite afirmar, não foram estudados os efeitos hemodinâmicos do CPAP em pacientes com estenose mitral, etiologia comum de congestão pulmonar em alguns países em desenvolvimento. Objetivos: Avaliar a resposta hemodinâmica dos pacientes portadores de estenose mitral sintomática durante o uso de CPAP. Métodos: Foram incluídos quarenta pacientes portadores de estenose mitral. Os critérios de exclusão foram: presença de disfunção ventricular esquerda, de outra valvopatia de grau moderado ou importante, de trombo intracavitário ao ecodopplercardiograma e de doença pulmonar obstrutiva crônica. Os pacientes foram avaliados em 3 condições diferentes: 1. condição basal, realizada ar ambiente; 2. uso de CPAP 7 cm H2O e 3. uso de CPAP 14 cm H2O. Foi realizada a medida de pressão arterial invasiva (aorta) e utilizado cateter de artéria pulmonar para a medida da pressão arterial pulmonar e débito cardíaco. Foram coletas amostras de gasometria arterial e venosa central. A variação percentual do volume sistólico (deltaVS) foi calculada tendo o valor na condição basal como 100% e foi correlacionada com as características clínicas, ecodopplercardiográficas, hemodinâmicas e gasométricas da condição basal. Os pacientes foram classificados em 3 grupos: grupo I - deltaVS <= -10%, grupo II - deltaVS entre -9,9% e +9,9% e grupo III - deltaVS >= +10%. Resultados: Durante a aplicação do CPAP, freqüência cardíaca, pressão arterial sistêmica e pressão arterial pulmonar não variaram significativamente. Na segunda condição, a deltaVS se correlacionou com a pressão arterial pulmonar diastólica e média, pressão de oclusão de capilar pulmonar e gradiente transvalvar mitral ao cateterismo. A análise dos grupos não identificou qualquer variável capaz de distingui-los. No uso de CPAP 14cmH2O, a deltaVS se correlacionou positivamente com a classe funcional, pressão sistólica do ventrículo direito (ao ecodopplercardiograma), freqüência cardíaca, pressão arterial sistêmica sistólica, pressão arterial pulmonar sistólica, diastólica e média, pressão de oclusão da artéria pulmonar e gradiente transvalvar mitral ao cateterismo. Além disso, nesta condição, a deltaVS se correlacionou inversamente com o volume sistólico indexado e saturação venosa de oxigênio. A análise comparativa dos grupos evidenciou, no grupo III, valores significativamente superiores de pressão sistólica do ventrículo direito (ao ecodopplercardiograma), pressão arterial pulmonar sistólica, diastólica e média, pressão de oclusão da artéria pulmonar e gradiente transvalvar mitral ao cateterismo. Não houve variável capaz de distinguir o grupo I do II. Conclusão: O uso de CPAP aumentou o volume sistólico nos pacientes com estenose mitral de maior impacto clínico e hemodinâmico, caracterizados por maior limitação funcional, hipertensão pulmonar e gradiente transvalvar mitral e menor saturação venosa de oxigênio e volume sistólico indexado. / Background: Continuous positive airway pressure (CPAP) impacts hemodynamic changes in heart failure patients by impending cardiac filling and reduces cardiac afterload by reducing left ventricular transmural pressure. These effects may collaborate for the success of this therapy in patients with pulmonary congestion. However, to your knowledge, no study has evaluated the hemodymanic effects of CPAP in patients with mitral stenosis, which is a common etiology of pulmonary congestion in some developing countries. Objectives: analyze the effects of CPAP on hemodynamic parameters in patients with symptomatic mitral stenosis. Methods: Forty patients with symptomatic mitral stenosis were included. They were monitored by aorta pressure and the insertion of a pulmonary artery catheter. Hemodynamic and gasometrical data were collected in each study period. Patients were evaluated in three study periods. Baseline condition was during spontaneous breathing. We applied CPAP 7 cm H2O in the second period and 14 cm H2O in the last period of the study. Were excluded patients with left ventricular systolic dysfunction, other valvopathy more than mild, and left atrial thrombi assessed by echocardiography and patients with history or symptom of chronic obstructive pulmonary disease. Percentage changes of stroke volume (deltaSV) were calculated with the values at baseline set as 100% and were correlated to clinical, ecocardiographic, hemodynamic and gasometrical data (at baseline). Patients were classified in group I if deltaSV was <= -10%, group II if deltaSV was between -9,9% and +9,9% or group III if deltaSV >= +10%. Results: During CPAP use, heart rate, systemic blood pressure and pulmonary artery pressure did not significantly change. At CPAP 7 cmH2O, deltaSV correlated positively with baseline values of diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. There was no variable capable to distinguish the groups. At CPAP 14 cmH2O, deltaSV correlated positively with functional class, pulmonary artery systolic pressure (measured by echocardiography), heart rate, systolic blood pressure, systolic pulmonary artery pressure, diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. Not only, at CPAP 14 cmH2O, deltaSV correlated inversely to indexed stroke volume and central venous saturation. Responders (group III) had superior pulmonary artery pressure (measured by echocardiography), systolic pulmonary artery pressure, diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. The comparison between groups I and II did not evidence any variable capable to distinguish them. Conclusion: CPAP improved stroke volume in those with mitral stenosis with greater clinical and hemodynamic impact, characterized by higher functional limitation, pulmonary hypertension and mean transmitral gradient and lower central venous saturation and indexed stroke volume.
6

Efeitos hemodinâmicos da ventilação não invasiva com pressão positiva em pacientes com estenose mitral sintomática / Hemodynamic effects of positive pressure noninvasive ventilation in patients with symptomatic mitral stenosis

Andre Moreira Bento 27 March 2008 (has links)
Introdução: O uso de pressão positiva contínua em vias aéreas (CPAP) causa modificações hemodinâmicas favoráveis em pacientes com insuficiência cardíaca. Na presença de disfunção ventricular esquerda, mecanismos hemodinâmicos propostos associam seu uso ao aumento do débito cardíaco, através da redução do enchimento e da pressão transmural do ventrículo esquerdo. Estes efeitos talvez colaborem para o sucesso dessa terapia em pacientes com congestão pulmonar. Entretanto, até onde extensa revisão bibliográfica nos permite afirmar, não foram estudados os efeitos hemodinâmicos do CPAP em pacientes com estenose mitral, etiologia comum de congestão pulmonar em alguns países em desenvolvimento. Objetivos: Avaliar a resposta hemodinâmica dos pacientes portadores de estenose mitral sintomática durante o uso de CPAP. Métodos: Foram incluídos quarenta pacientes portadores de estenose mitral. Os critérios de exclusão foram: presença de disfunção ventricular esquerda, de outra valvopatia de grau moderado ou importante, de trombo intracavitário ao ecodopplercardiograma e de doença pulmonar obstrutiva crônica. Os pacientes foram avaliados em 3 condições diferentes: 1. condição basal, realizada ar ambiente; 2. uso de CPAP 7 cm H2O e 3. uso de CPAP 14 cm H2O. Foi realizada a medida de pressão arterial invasiva (aorta) e utilizado cateter de artéria pulmonar para a medida da pressão arterial pulmonar e débito cardíaco. Foram coletas amostras de gasometria arterial e venosa central. A variação percentual do volume sistólico (deltaVS) foi calculada tendo o valor na condição basal como 100% e foi correlacionada com as características clínicas, ecodopplercardiográficas, hemodinâmicas e gasométricas da condição basal. Os pacientes foram classificados em 3 grupos: grupo I - deltaVS <= -10%, grupo II - deltaVS entre -9,9% e +9,9% e grupo III - deltaVS >= +10%. Resultados: Durante a aplicação do CPAP, freqüência cardíaca, pressão arterial sistêmica e pressão arterial pulmonar não variaram significativamente. Na segunda condição, a deltaVS se correlacionou com a pressão arterial pulmonar diastólica e média, pressão de oclusão de capilar pulmonar e gradiente transvalvar mitral ao cateterismo. A análise dos grupos não identificou qualquer variável capaz de distingui-los. No uso de CPAP 14cmH2O, a deltaVS se correlacionou positivamente com a classe funcional, pressão sistólica do ventrículo direito (ao ecodopplercardiograma), freqüência cardíaca, pressão arterial sistêmica sistólica, pressão arterial pulmonar sistólica, diastólica e média, pressão de oclusão da artéria pulmonar e gradiente transvalvar mitral ao cateterismo. Além disso, nesta condição, a deltaVS se correlacionou inversamente com o volume sistólico indexado e saturação venosa de oxigênio. A análise comparativa dos grupos evidenciou, no grupo III, valores significativamente superiores de pressão sistólica do ventrículo direito (ao ecodopplercardiograma), pressão arterial pulmonar sistólica, diastólica e média, pressão de oclusão da artéria pulmonar e gradiente transvalvar mitral ao cateterismo. Não houve variável capaz de distinguir o grupo I do II. Conclusão: O uso de CPAP aumentou o volume sistólico nos pacientes com estenose mitral de maior impacto clínico e hemodinâmico, caracterizados por maior limitação funcional, hipertensão pulmonar e gradiente transvalvar mitral e menor saturação venosa de oxigênio e volume sistólico indexado. / Background: Continuous positive airway pressure (CPAP) impacts hemodynamic changes in heart failure patients by impending cardiac filling and reduces cardiac afterload by reducing left ventricular transmural pressure. These effects may collaborate for the success of this therapy in patients with pulmonary congestion. However, to your knowledge, no study has evaluated the hemodymanic effects of CPAP in patients with mitral stenosis, which is a common etiology of pulmonary congestion in some developing countries. Objectives: analyze the effects of CPAP on hemodynamic parameters in patients with symptomatic mitral stenosis. Methods: Forty patients with symptomatic mitral stenosis were included. They were monitored by aorta pressure and the insertion of a pulmonary artery catheter. Hemodynamic and gasometrical data were collected in each study period. Patients were evaluated in three study periods. Baseline condition was during spontaneous breathing. We applied CPAP 7 cm H2O in the second period and 14 cm H2O in the last period of the study. Were excluded patients with left ventricular systolic dysfunction, other valvopathy more than mild, and left atrial thrombi assessed by echocardiography and patients with history or symptom of chronic obstructive pulmonary disease. Percentage changes of stroke volume (deltaSV) were calculated with the values at baseline set as 100% and were correlated to clinical, ecocardiographic, hemodynamic and gasometrical data (at baseline). Patients were classified in group I if deltaSV was <= -10%, group II if deltaSV was between -9,9% and +9,9% or group III if deltaSV >= +10%. Results: During CPAP use, heart rate, systemic blood pressure and pulmonary artery pressure did not significantly change. At CPAP 7 cmH2O, deltaSV correlated positively with baseline values of diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. There was no variable capable to distinguish the groups. At CPAP 14 cmH2O, deltaSV correlated positively with functional class, pulmonary artery systolic pressure (measured by echocardiography), heart rate, systolic blood pressure, systolic pulmonary artery pressure, diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. Not only, at CPAP 14 cmH2O, deltaSV correlated inversely to indexed stroke volume and central venous saturation. Responders (group III) had superior pulmonary artery pressure (measured by echocardiography), systolic pulmonary artery pressure, diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. The comparison between groups I and II did not evidence any variable capable to distinguish them. Conclusion: CPAP improved stroke volume in those with mitral stenosis with greater clinical and hemodynamic impact, characterized by higher functional limitation, pulmonary hypertension and mean transmitral gradient and lower central venous saturation and indexed stroke volume.
7

Currarino-Silverman Syndrome (Pectus Carinatum Type 2 Deformity) and Mitral Valve Disease

Chidambaram, B, Mehta, A. V. 01 September 1992 (has links)
Currarino-Silverman syndrome is a rare disorder characterized by premature fusion of manubrio-sternal joint and the sternal segments, resulting in a high carinate chest deformity; it is frequently associated with congenital heart disease. Among the various heart lesions reported in this syndrome, mitral valve disease and coarctation of the aorta have not yet been described (to our knowledge). Our report consists of five children with this syndrome, four of whom had mitral valve disease, with an associated coarctation of the aorta in one patient. The fifth patient had an innocent heart murmur.
8

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Pinto, Nathali Cordeiro 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy
9

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Nathali Cordeiro Pinto 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy

Page generated in 0.5194 seconds