• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilização da técnica da reflectometria no domínio do tempo para medidas de condutividade elétrica aparente de um solo / Use of the time domain reflectometry technique for soil bulk electrical conductivity measurements

Oro, Alice Leal Terres 20 July 2006 (has links)
Made available in DSpace on 2017-07-10T19:25:03Z (GMT). No. of bitstreams: 1 Alice Leal Terres Oro.pdf: 734105 bytes, checksum: 00f0a2e6f0c0139384a1298b29fdcc57 (MD5) Previous issue date: 2006-07-20 / Measurements of solute concentrations at soils are essential to optimize irrigation and fertilizer application, to study surface runoff and erosion and to evaluate soil salinity. For this purpose, Time Domain Reflectometry is a dielectric technique that has been shown to give accurate water content and electrical conductivity values. Used under both laboratory and field conditions, this a non-destructive essay takes simultaneous measurements of electrical conductivity and soil water content, using a single probe and testing only one sample region. Although there are many ways in which electrical conductivity may be obtained with Time Domain Reflectometry equipment, few of them are characterized by simplicity and straight forwardness. Because of that, this study aimed to evaluate different methods to determine electrical conductivity at solutions and soils. A sequence of laboratory experiments was conducted in deformed soil samples of an Oxisol from West Parana State, arranged in columns 0,30 m height, with an internal diameter of 0,19 m. The three wire probes, with manual assembling and without impedance-matching transformer, were vertically installed in soil columns, considering as a control one the column which soil received only distilled water. The others treatments were defined according to the sodium chloride content: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 and 0,15 N. The electrical conductivity was determined using waveforms collected with specific software and there wasn t signal attenuation. It was found a linear relationship between the bulk electrical conductivity and the pore water electrical conductivity under constant water content. It was concluded that soils with significant iron contents display an atypical dielectric behavior that limits the applicability of the equipment for measuring not only soil moisture but bulk electrical conductivity also. / Medidas de concentrações de solutos em solos são essenciais para otimizar a irrigação e aplicações de fertilizantes, para estudar escoamento superficial e erosão e para avaliar a salinidade do solo. Para tal fim, a Reflectometria no Domínio do Tempo é uma técnica dielétrica que tem sido capaz de fornecer valores precisos, tanto para teores de água como para condutividade elétrica do solo. Empregada tanto em condições de laboratório como em condições de campo, esta técnica não-destrutiva realiza medidas simultâneas das duas grandezas, empregando uma única sonda e testando a mesma região da amostra. Embora existam várias técnicas através das quais a condutividade elétrica pode ser determinada com um equipamento de Reflectometria no Domínio do Tempo, poucas técnicas são caracterizadas pela simplicidade e pela rapidez. Devido a isso, o presente trabalho objetivou avaliar diferentes métodos para a determinação da condutividade elétrica de soluções e de solos. O trabalho foi desenvolvido em condições de laboratório, usando amostras deformadas de um Latossolo Vermelho distroférrico da Região Oeste do Paraná, acondicionadas em colunas com comprimento de 0,30 m e diâmetro de 0,19 m. As sondas com 3 hastes, montadas de forma artesanal e sem qualquer equalização de impedâncias, foram instaladas verticalmente nas colunas de solo, sendo considerada como controle a coluna cujo solo recebeu água destilada. Os outros tratamentos foram definidos conforme os teores de cloreto de sódio adicionado: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 e 0,15 N. A condutividade elétrica foi determinada a partir das formas de onda coletadas com um programa específico e não ocorreu atenuação de sinal. Encontrou-se uma relação linear entre as medidas de condutividade elétrica total do solo e a condutividade elétrica da solução do solo, sob umidade constante. Também se concluiu que solos com alto teor de Fe exibem um comportamento dielétrico atípico, o qual limita a aplicabilidade da técnica.
2

Utilização da técnica da reflectometria no domínio do tempo para medidas de condutividade elétrica aparente de um solo / Use of the time domain reflectometry technique for soil bulk electrical conductivity measurements

Oro, Alice Leal Terres 20 July 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:24Z (GMT). No. of bitstreams: 1 Alice Leal Terres Oro.pdf: 734105 bytes, checksum: 00f0a2e6f0c0139384a1298b29fdcc57 (MD5) Previous issue date: 2006-07-20 / Measurements of solute concentrations at soils are essential to optimize irrigation and fertilizer application, to study surface runoff and erosion and to evaluate soil salinity. For this purpose, Time Domain Reflectometry is a dielectric technique that has been shown to give accurate water content and electrical conductivity values. Used under both laboratory and field conditions, this a non-destructive essay takes simultaneous measurements of electrical conductivity and soil water content, using a single probe and testing only one sample region. Although there are many ways in which electrical conductivity may be obtained with Time Domain Reflectometry equipment, few of them are characterized by simplicity and straight forwardness. Because of that, this study aimed to evaluate different methods to determine electrical conductivity at solutions and soils. A sequence of laboratory experiments was conducted in deformed soil samples of an Oxisol from West Parana State, arranged in columns 0,30 m height, with an internal diameter of 0,19 m. The three wire probes, with manual assembling and without impedance-matching transformer, were vertically installed in soil columns, considering as a control one the column which soil received only distilled water. The others treatments were defined according to the sodium chloride content: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 and 0,15 N. The electrical conductivity was determined using waveforms collected with specific software and there wasn t signal attenuation. It was found a linear relationship between the bulk electrical conductivity and the pore water electrical conductivity under constant water content. It was concluded that soils with significant iron contents display an atypical dielectric behavior that limits the applicability of the equipment for measuring not only soil moisture but bulk electrical conductivity also. / Medidas de concentrações de solutos em solos são essenciais para otimizar a irrigação e aplicações de fertilizantes, para estudar escoamento superficial e erosão e para avaliar a salinidade do solo. Para tal fim, a Reflectometria no Domínio do Tempo é uma técnica dielétrica que tem sido capaz de fornecer valores precisos, tanto para teores de água como para condutividade elétrica do solo. Empregada tanto em condições de laboratório como em condições de campo, esta técnica não-destrutiva realiza medidas simultâneas das duas grandezas, empregando uma única sonda e testando a mesma região da amostra. Embora existam várias técnicas através das quais a condutividade elétrica pode ser determinada com um equipamento de Reflectometria no Domínio do Tempo, poucas técnicas são caracterizadas pela simplicidade e pela rapidez. Devido a isso, o presente trabalho objetivou avaliar diferentes métodos para a determinação da condutividade elétrica de soluções e de solos. O trabalho foi desenvolvido em condições de laboratório, usando amostras deformadas de um Latossolo Vermelho distroférrico da Região Oeste do Paraná, acondicionadas em colunas com comprimento de 0,30 m e diâmetro de 0,19 m. As sondas com 3 hastes, montadas de forma artesanal e sem qualquer equalização de impedâncias, foram instaladas verticalmente nas colunas de solo, sendo considerada como controle a coluna cujo solo recebeu água destilada. Os outros tratamentos foram definidos conforme os teores de cloreto de sódio adicionado: 0,01; 0,03; 0,05; 0,07; 0,09; 0,10 e 0,15 N. A condutividade elétrica foi determinada a partir das formas de onda coletadas com um programa específico e não ocorreu atenuação de sinal. Encontrou-se uma relação linear entre as medidas de condutividade elétrica total do solo e a condutividade elétrica da solução do solo, sob umidade constante. Também se concluiu que solos com alto teor de Fe exibem um comportamento dielétrico atípico, o qual limita a aplicabilidade da técnica.

Page generated in 0.0423 seconds