• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 1
  • Tagged with
  • 14
  • 11
  • 11
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Aplica??o da t?cnica eletroanal?tica de pulso diferencial usando o eletrodo de carbono v?treo modificado com ciste?na para monitorar a degrada??o eletroqu?mica de ?cido ox?lico

Neves, Nathalia Costa Viana 31 July 2013 (has links)
Made available in DSpace on 2014-12-17T15:42:11Z (GMT). No. of bitstreams: 1 NathaliaCVN_DISSERT.pdf: 2020842 bytes, checksum: efcd9ca5e5cfd7d63412f72c80546c39 (MD5) Previous issue date: 2013-07-31 / In this paper, the technique of differential pulse voltammetry (DPV) has been studied for monitoring the concentration of oxalic acid (OA) during their electrochemical oxidation (EO) in acidic medium using platinum anode supported on titanium (Ti / Pt). The DPV was standardized and optimized using a glassy carbon electrode modified with cysteine. The modification with cysteine was developed electrochemically, forming a polymeric film on the surface of the glassy carbon electrode. The formation of the polymer film was confirmed by analysis of scanning electron microscope and atomic force microscope, confirming the modification of the electrode. The electrochemical degradation was developed using different current densities 10, 20 30 and 40 mA cm -2 electrode with Ti / Pt observing the degradation of oxalic acid, and monitored using the method of KMnO4 titration. However, the analyzes with DPV showed the same behavior elimination of oxalic acid titration. Compared with the titration method classical observed and DPV could be a good fit, confidence limits of detection and confirming the applicability of the technique electroanalytical for monitoring the degradation of oxalic acid / No presente trabalho, a t?cnica de voltametria de pulso diferencial (DPV) foi estudada para o monitoramento da concentra??o de ?cido ox?lico (OA) durante a sua oxida??o eletroqu?mica (EO) em meio ?cido utilizando o ?nodo de platina suportada em tit?nio (Ti/Pt). A t?cnica de DPV foi padronizada e otimizada usando um eletrodo de carbono v?treo modificado com ciste?na. A modifica??o com ciste?na foi desenvolvida eletroquimicamente, formando um filme polim?rico na superf?cie do eletrodo de carbono v?treo. A forma??o do filme polim?rico foi confirmada por an?lise de Microsc?pio Eletr?nico de Varredura e Microsc?pio de For?a At?mica, confirmando a modifica??o na superf?cie do eletrodo. A degrada??o eletroqu?mica foi desenvolvida usando diferentes densidades de corrente, 10, 20 e 30 mA cm-? com eletrodo de Ti/Pt, observando a degrada??o do ?cido ox?lico, sendo monitorado empregando a metodologia de titula??o com KmnO4. No entanto, as an?lises com DPV mostraram o mesmo comportamento de elimina??o do acido ox?lico, observado com a titula??o. Comparado com o m?todo de titula??o cl?ssica e DPV conseguiu-se um bom ajuste, intervalos de confian?a e limites de detec??o confirmando a aplicabilidade da t?cnica eletroanal?tica para o monitoramento da degrada??o de ?cido ox?lico
12

Uma ferramenta de an?lise automatizada de t?cnicas de sele??o de testes de regress?o baseada em minera??o de reposit?rios de software

Cruz J?nior, Jo?o Maria Guedes da 29 April 2014 (has links)
Made available in DSpace on 2014-12-17T15:48:10Z (GMT). No. of bitstreams: 1 JoaoMGCJ_DISSERT.pdf: 2157600 bytes, checksum: e625012e4cd3f5e995b205310bff8592 (MD5) Previous issue date: 2014-04-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The main goal of Regression Test (RT) is to reuse the test suite of the latest version of a software in its current version, in order to maximize the value of the tests already developed and ensure that old features continue working after the new changes. Even with reuse, it is common that not all tests need to be executed again. Because of that, it is encouraged to use Regression Tests Selection (RTS) techniques, which aims to select from all tests, only those that reveal faults, this reduces costs and makes this an interesting practice for the testing teams. Several recent research works evaluate the quality of the selections performed by RTS techniques, identifying which one presents the best results, measured by metrics such as inclusion and precision. The RTS techniques should seek in the System Under Test (SUT) for tests that reveal faults. However, because this is a problem without a viable solution, they alternatively seek for tests that reveal changes, where faults may occur. Nevertheless, these changes may modify the execution flow of the algorithm itself, leading some tests no longer exercise the same stretch. In this context, this dissertation investigates whether changes performed in a SUT would affect the quality of the selection of tests performed by an RTS, if so, which features the changes present which cause errors, leading the RTS to include or exclude tests wrongly. For this purpose, a tool was developed using the Java language to automate the measurement of inclusion and precision averages achieved by a regression test selection technique for a particular feature of change. In order to validate this tool, an empirical study was conducted to evaluate the RTS technique Pythia, based on textual differencing, on a large web information system, analyzing the feature of types of tasks performed to evolve the SUT / O objetivo dos testes de regress?o (RT) ? reutilizar o conjunto de testes da ?ltima vers?o de um software em sua vers?o atual, para maximizar o valor dos testes j? desenvolvidos e garantir que antigas funcionalidades continuem corretas ap?s as novas modifica??es. Mesmo com o reuso, ? comum que nem todos os testes precisem ser executados novamente e para evitar o desnecess?rio, ? estimulada a utiliza??o de t?cnicas de sele??o dos testes de regress?o (RTS), que buscam selecionar dentre todos os testes, apenas aqueles capazes de revelar faltas, isto reduz custos e torna a pr?tica realmente atrativa para as equipes de teste. Diversos estudos recentes avaliam a qualidade da sele??o realizadas por t?cnicas de RTS, identificando qual delas apresenta melhores resultados atrav?s de m?tricas como a inclus?o e a precis?o. As t?cnicas de RTS deveriam buscar no sistema sob teste (SUT) por testes que revelem faltas, entretanto, como este ? um problema sem solu??o vi?vel, a alternativa ? buscar por testes que revelem as modifica??es, onde as faltas podem ocorrer. Contudo, tais modifica??es podem alterar o pr?prio fluxo de execu??o dos algoritmos, fazendo com que alguns testes n?o exercitem mais os mesmos trechos. Neste contexto, esta disserta??o de mestrado busca investigar se as modifica??es realizadas no SUT poderiam afetar a qualidade da sele??o dos testes realizada por uma RTS, e se sim, quais caracter?sticas apresentam as modifica??es que provocaram os erros, levando a RTS a incluir ou excluir testes erroneamente. Para tanto, foi desenvolvida uma ferramenta na linguagem Java para automatizar o c?lculo da inclus?o e precis?o m?dias alcan?adas por uma t?cnica de RTS para uma dada caracter?stica da modifica??o. A fim de validar a ferramenta, foi conduzido um estudo emp?rico para avaliar a t?cnica de RTS Pythia, baseada em diferencia??o textual, sobre um sistema de informa??o web de larga escala, analisando a caracter?stica dos tipos das tarefas realizadas para evoluir o SUT
13

Aplica??o de superf?cies seletivas em frequ?ncia para melhoria de resposta de arranjos de antenas planares

Almeida Filho, Valdez Arag?o de 12 March 2014 (has links)
Made available in DSpace on 2014-12-17T14:55:20Z (GMT). No. of bitstreams: 1 ValdezAAF_TESE.pdf: 2001050 bytes, checksum: d0f0b88178102c3f48880303c1c6d765 (MD5) Previous issue date: 2014-03-12 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This work aims to show how the application of frequency selective surfaces (FSS) in planar antenna arrays become an alternative to obtain desired radiation characteristics from changes in radiation parameters of the arrays, such as bandwidth, gain and directivity. In addition to analyzing these parameters is also made a study of the mutual coupling between the elements of the array. To accomplish this study, were designed a microstrip antenna array with two patch elements, fed by a network feed. Another change made in the array was the use of the truncated ground plane, with the objective of increasing the bandwidth and miniaturize the elements of the array. In order to study the behavior of frequency selective surfaces applied in antenna arrays, three different layouts were proposed. The first layout uses the FSS as a superstrate (above the array). The second layout uses the FSS as reflector element (below the array). The third layout is placed between two FSS. Numerical and experimental results for each of the proposed configurations are presented in order to validate the research / Este trabalho tem como objetivo apresentar como a aplica??o de superf?cies seletivas em frequ?ncia (FSS) em arranjos de antenas planares se torna uma alternativa interessante para se obter caracter?sticas de radia??o desejadas, a partir de altera??es em par?metros de radia??o dos arranjos, tais como largura de banda, ganho e diretividade. Al?m de analisar esses par?metros, tamb?m ? feito o estudo do acoplamento m?tuo entre os elementos do arranjo. Para realizar tal estudo, foi projetado um arranjo de antenas de microfita, com dois elementos do tipo patch, alimentado por uma rede de alimenta??o. Outra modifica??o feita no arranjo foi a utiliza??o do plano de terra truncado, com o objetivo de aumentar a largura de banda e miniaturizar os elementos do arranjo. Para poder estudar o comportamento das superf?cies seletivas em frequ?ncia aplicadas em arranjos de antenas, foram propostos tr?s layouts diferentes. O primeiro layout consiste em utilizar a FSS como superstrato (acima do arranjo). O segundo consiste em utilizar a FSS como elemento refletor (abaixo do arranjo). O terceiro layout consiste em colocar o arranjo entre duas camadas de FSS, tanto em cima quanto abaixo. Resultados num?ricos e experimentais para cada uma das configura??es propostas s?o apresentados
14

Desenho e Constru??o de um prot?tipo gerador de jato de plasma frio a press?o atmosf?rica para aplica??es biom?dicas

Nascimento Neto, Arlindo Balbino do 07 February 2014 (has links)
Made available in DSpace on 2014-12-17T14:58:24Z (GMT). No. of bitstreams: 1 ArlindoBNN_DISSERT.pdf: 2586996 bytes, checksum: 478bf85288aae614a5921757e3272558 (MD5) Previous issue date: 2014-02-07 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface / Pesquisas na busca por materiais com melhor desempenho para aplica??es biom?dicas s?o constantes. Assim, estudos recentes buscam o desenvolvimento de novas t?cnicas para modifica??es de superf?cies. O plasma a baixa press?o vem se destacando pela sua versatilidade e por ser ambientalmente correto, obtendo-se bons resultados na modifica??o das propriedades f?sico-qu?micas dos materiais. Por?m, esta t?cnica necessita de um sistema de v?cuo de alto custo e n?o ? capaz de gerar modifica??es superficiais em regi?es pontuais. Al?m disso, limita seu uso em materiais polim?ricos e termosens?veis, devido ?s altas temperaturas do processo. Diante disso, foram criadas novas t?cnicas capazes de gerar um plasma frio a press?o atmosf?rica (APPJ). Com o objetivo de realizar tratamentos superficiais em biomateriais em regi?es pontuais, foi constru?do um prot?tipo capaz de gerar um jato de plasma frio. O prot?tipo gerador de plasma consiste em uma fonte de alta tens?o, um bra?o suporte, um porta amostra e uma ponteira por onde passa o arg?nio ionizado. Dentro desta ponteira existe um tubo diel?trico e dois eletrodos. Neste estudo foram variados alguns par?metros como: posi??o entre eletrodos, tens?o e frequ?ncia el?trica para verificar o comportamento das descargas luminescentes. Tratou-se disco de tit?nio grau II polido e verificou-se a energia el?trica consumida, comprimento, intensidade e modifica??es superficiais do tit?nio. A energia consumida durante as descargas foram verificadas pelo m?todo da figura de Lissajous. Para verificar o comprimento dos jatos foi utilizado o software Image Pro Plus. As modifica??es na superf?cie do tit?nio foram verificadas por microscopia ?tica (MO) e de for?a at?mica (MFA). O trabalho mostrou que varia??es dos par?metros de tens?o, frequ?ncia e posi??o geom?trica entre os eletrodos influenciam na forma??o do jato de plasma. Foi poss?vel concluirque o jato de plasma pr?ximo ? temperatura ambiente e a press?o atmosf?rica foi capaz de provocar modifica??es superficiais no tit?nio

Page generated in 0.0596 seconds