• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 1
  • Tagged with
  • 20
  • 14
  • 14
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e avaliação de um sistema de cálculo de dose independente para controle de qualidade de IMRT do tipo jaws-only

Silva, Luis Felipe Oliveira e 30 October 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-06-06T17:55:07Z No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-06-15T11:30:22Z (GMT) No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5) / Made available in DSpace on 2016-06-15T11:30:22Z (GMT). No. of bitstreams: 1 2015_LuisFelipeOliveiraeSilva.pdf: 5470471 bytes, checksum: 1fe65af174596febff5a94a7a05ae399 (MD5) / A radioterapia de intensidade modulada (IMRT, do inglês intensitymodulatedradiotherapy) proporciona distribuições de dose bastante complexas, com regiões de alto gradiente de dose. Essa complexidade representa um desafio maior no controle de qualidade (CQ) quando se compara a IMRT com a radioterapia convencional. O objetivo do presente trabalho foi desenvolver e avaliar um sistema de cálculo de dose independente, chamado SCI, para o controle de qualidade da IMRT do tipojawsonly. O software desenvolvido utiliza um algoritmo de cálculo de dose baseado em correções realizadas no fator de calibração do acelerador linear, por meio de fatores tabelados, derivados de medições e calculados a partir de simples modelagem. Os próprios dados gerados no comissionamento são usados para alimentar o algoritmo.Os cálculos são realizados em um plano de um fantoma retangular. Para validar o SCI, comparações entre as previsões dosimétricas do sistema e outras referências foram realizadas. Foram comparados: doses pontuais no centro de campos assimétricos medidos com câmara de ionização; perfis de campos medidos com filme radiocrômico e com câmara de ionização; distribuições planares de dose de cinco casos de câncer de próstata e cinco de cabeça e pescoço medidas com um arranjo bidimensional de câmaras de ionização e calculadas pelo sistema de planejamento de tratamento (SPT). A avaliação foi realizada utilizando diferenças percentuais de dose, a menor diferença de posição em que se encontra o mesmo valor de dose (DTA, do inglês distancetoagreement) e a avaliação gama com critérios: (i) diferença máxima de dose de 3%, DTA de 3 mm; (ii) diferença máxima de dose 5%, DTA de 3 mm; e (iii) diferença máxima de dose 5%, DTA de 5 mm. As diferenças encontradas nas comparações entre as doses obtidas no centro de campos assimétricos foram menores do que 2,5%.As diferenças nos perfis dos campos quadrados menores do que 30x30 cm2 foram menores do que 2% ou 2mm. Os campos menores, medidos com filme, apresentaram diferenças mais consideráveis (DTAs de até 5 mm foram observadas). Esse resultado já era esperado devido à maior resolução espacial do filme quando comparada à da câmara de ionização (volume sensível de 0,125 cc). As avaliações gama usando tanto as medições quanto o SPT como referência sugerem que o SCI representa a distribuição de dose real segundo o critério de 5% de diferença máxima de dose e 5 mm de DTA, uma vez que a média de pontos aprovados foi superior a 96,5% (p<0,001) em todos os casos quando esse critério foi utilizado. O sistema também apresenta um boa representação segundo o critério de 5% de diferença máxima de dose e 3 mm de DTA (média de pontos aprovados superior a 92,0%; p<0,01). As médias de pontos aprovados com esses dois critérios estão, portanto, de acordo com os valores tipicamente usados como referência por profissionais da área de radioterapia. Desta forma, o sistema desenvolvido no presente trabalho está pronto para ser utilizado para o CQ de IMRT do tipo jawsonly sem custo adicional em relação aos equipamentos já utilizados, reduzindo o fluxo de trabalho comparado a métodos mais tradicionais e sem ocupação adicional da máquina de tratamento. / Intensity modulated radiation therapy (IMRT) provides complex dose distributions with high dose gradient regions. This complexity is a major challenge for quality assurance (QA), specially when comparing IMRT with conventional radiotherapy. In this research, I propose, develop, and evaluate an independent dose calculation system for QA of jaws only IMRT (JOIMRT). The developed software uses a dose calculation algorithm based on corrections performed over the linear accelerator (linac) calibration factor. In order to perform this corrections I used tabulated factors derived from measurements and calculated from simple modeling. Also, I used the linac's commissioning data as input to the algorithm.The developed system then performs the main computations over a rectangular phantom plan. To validate the proposed system, I compared the predictions of the dosimetric system with references that are commonly used in the literature. Specifically, I compared: point doses in the center of asymmetric field measured with an ionization chamber; dose profiles measured with radiochromic film and an ionization chamber; planar dose distributions of five of prostate and five head and neck cases measured with a two-dimensional array of ionization chambers and calculated by the treatment planning system (TPS). The evaluation was performed using percentage dose differences, distance to agreement (DTA) and gamma evaluation with tree criterions: (i) maximum difference dose of 3% and 3 mm DTA, (ii) maximum difference dose of 5% and 3 mm DTA, and (iii) maximum difference dose of 5% and 5 mm DTA. The differences in the comparisons between the doses obtained in the center of asymmetric fields were smaller than 2.5%. Differences in the profiles of square fields up to 30x30 cm2 were smaller than 2% or 2 mm. Smaller fields measured with film showed more significant differences (I measured DTAs up to 5 mm). This result was expected because of the higher spatial resolution of the film, as compared to the ionization chamber that provided the measurements used as inputs to the calculation algorithm (sensitive volume of 0.125 cc). The point approval ratings using both measurements and the TPS as a reference suggest that the independent dose calculation system represents the actual dose distribution according to the criterion of 5 % maximum dose difference and 5 mm DTA, since the average was approved points above 96.5% (<0,001) in all cases when this criterion was used. The system also features a good representation according to the criterion of 5% maximal dose difference and 3 mm DTA (average of approved points above 92.0%; p <0.01). Therefore, the average of approved points obtained with those two criteria satisfies the values typically used as references by radiotherapy professionals. In this way, the system I developed is ready to be used for the JOIMRT QA with no additional cost with respect to equipment already used, reducing the workload compared to more traditional methods and without additional treatment machine occupation.
2

Determinación Experimental de la Temperatura y la Fracción en Volumen de Hollín en una Llama de Difusión Laminar, por Medio de Absorción/Emisión Modulada

Cuevas Rodríguez, Juan Ignacio January 2012 (has links)
Este estudio tiene como propósito entender el fenómeno de la producción de partículas de hollín en la combustión de una llama de difusión, centrándose principalmente en el estudio de la combustión de gas obtenido de la pirólisis de biomasa vegetal sólida. Como parte de la técnica experimental se implementó un banco experimental que permita la evaluación de estas características en una llama de difusión laminar generada a partir de etileno y aire con distintas concentraciones de oxígeno, en un quemador axisimétrico tipo Guelder. Como antecedente, puede decirse que el hollín es uno de los principales contaminantes que se generan en el proceso de combustión y además, una de las principales fuentes de radiación de la llama. Complementariamente, este mecanismo de transferencia de calor tiene directa relación con la estructura de la llama y actualmente se piensa que es el responsable del fenómeno de extinción de llama (Quenching). Se realizaron mediciones que permiten obtener la distribución local de la temperatura y la fracción en volumen de hollín mediante la aplicación de la técnica de diagnóstico no intrusiva MAE (Modulated Absorption/Emission), utilizando longitudes de onda en el rango visible. En el caso de la temperatura, se realizó una evaluación indirecta de ésta a partir de la medición de la intensidad de la radiación del hollín a dos longitudes de onda distintas. La fracción en volumen de hollín se evaluó en base a las mediciones en una longitud de onda. Se encontró que la temperatura de la llama aumenta de manera proporcional con el contenido de oxígeno en el aire, para un mismo flujo de combustible. De los campos y perfiles de temperatura obtenidos, es posible identificar las zonas de máxima temperatura en la llama y ubicarlas en la zona central de ésta. Con respecto a la fracción en volumen de hollín, esta también aumenta con proporcionalmente con el contenido de oxígeno en el oxidante, encontrándose además que los máximos locales en cada nivel están correlacionados positivamente con las temperaturas máximas alcanzadas. De manera general, se encontró que las mayores concentraciones de hollín en la zona basal de la llama se ubican en los costados de ésta, mientras que en la zona central y superior de ésta las zonas de mayor concentración se ubican en el centro de la llama con respecto al eje de simetría. En conclusión, se encontró que la cantidad de oxígeno en el aire juega un rol importante en la temperatura de la llama y la fracción en volumen de hollín producida por ésta. Se encontró una proporcionalidad directa entre el porcentaje de oxígeno y la temperatura y fracción en volumen de hollín. Más aún, la existencia de una correlación entre los máximos de temperatura y los de fracción en volumen de hollín revalida la afirmación hecha en los antecedentes donde se señala al hollín como una de las grandes fuentes de radiación de la llama. Con respecto a la técnica, se demostró su efectividad como método de diagnóstico rápido y preciso, no siendo necesario en este caso, dada la estabilidad de la llama, una modulación a altas frecuencias.
3

Avaliação das ferramentas de controle de qualidade para pacientes submetidos ao IMRT / Evaluation tools of quality control for patients submitted to IMRT

Lavor, Milton 07 April 2011 (has links)
Atualmente a radioterapia de intensidade modulada (IMRT) está sendo implementada em um número crescente de centros no Brasil. Como conseqüência disto, muitas instituições estão enfrentando o problema de executar um programa de controle de qualidade antes e durante a execução do IMRT na prática da rotina clínica. O objetivo deste trabalho é avaliar e propor uma metodologia para o controle de qualidade de tratamentos com IMRT. Uma câmara de ionização e um detector bidimensional foram utilizados para avaliar a dose absoluta total de todos os campos em um determinado ponto. A distribuição de dose relativa total de todos os campos foi medida com filmes radiocrômicos e um detector bidimensional em uma profundidade no objeto simulador. Uma comparação entre as distribuições de dose medidas e calculadas foi realizada usando o método do índice gama, avaliando o percentual de pontos que satisfazem os critérios de diferença dose de ±3% e distância de concordância de ±3 mm. Como resultado da dosimetria absoluta de 113 feixes de IMRT medidos com uma câmara de ionização e 81 feixes usando o detector bidimensional, foi proposto um nível de ação de cerca de ± 5% em relação ao sistema de planejamento e de tratamento para a verificação da dose em um único ponto na região de baixo gradiente de dose. A análise das medições com o detector bidimensional mostrou que o valor da função gama foi <1 para 97,7% dos dados e, para o filme, o valor da função gama foi <1 para 96,6% dos dados. Neste trabalho pode-se concluir que para uma entrega exata de dose em IMRT sliding-window com um colimador micro multilâminas, os parâmetros de dose total absoluta e distribuição de dose total relativa devem ser verificados por dosimetria absoluta e relativa respectivamente. / Intensity modulated radiation therapy (IMRT) is currently been implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical routine practice. The aim of this work is to evaluate and propose a methodology for quality assurance in IMRT treatments. An ionization chamber and a two-dimensional array detector were performed to assess the absolute value of the total dose of all fields in one specific point. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array at one depth in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of ±3% dose difference and ±3 mm distance to agreement. As a result of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about ± 5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This can be concluded that for an accurate delivery of dose in sliding-window IMRT with micro multileaf collimator, the absolute value of the total dose and the relative total dose distribution should be checked by absolute and relative dosimetry respectively.
4

Classificação automática de modulações digitais usando histogramas e máquinas de vetores de suporte

Sorato, Edson January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Ciência da Computação, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:26:28Z (GMT). No. of bitstreams: 1 331903.pdf: 2365363 bytes, checksum: df1d0a2c1efb5a7b665283338d74018c (MD5) Previous issue date: 2014 / A rápida expansão de comunicações sem fio tornaram o espectro de rádio frequência um recurso bastante escasso. O rádio cognitivo surgiu como uma solução viável para contornar essa dificuldade. No contexto de rádio cognitivo, o monitoramento de espectro (Spectrum Sensing (SS)) desempenha um papel fundamental. Em particular, a Classificação Automática de Modulações (Automatic Modulation Classification (AMC)) é um dos blocos computacionais que mais demanda recursos dentro do SS. Atualmente, as pesquisas em AMC concentram-se no desenvolvimento de métodos rápidos e precisos que sejam capazes de atingir o throughput exigido por aplicações contemporâneas. Alguns trabalhos recentes tem proposto o uso de histogramas do sinal de entrada como parâmetros de classificação e Máquinas de Vetores de Suporte (Support Vector Machine (SVM)) como técnica de classificação. O presente trabalho apresenta uma avaliação de tal abordagem e busca projetar arquiteturas de hardware dedicadas eficientes para AMC. Na primeira parte deste trabalho, soluções de hardware para classificação de múltiplas classes usando SVM são projetadas e avaliadas. O esquema "um contra todos melhorado" proposto apresentou uma taxa de acertos até 162% maior do que o esquema "um contra um" comumente utilizado, sendo 30;2% mais eficiente em termos de energia consumida para classificação. Na segunda parte do trabalho, o uso de histogramas em conjunto com SVM é avaliado como uma técnica de classificação cega. Isso é realizado através de experimentos que assumem que o receptor não conhece a taxa de dados do transmissor, em oposição aos trabalhos correlatos. Como outra novidade, histogramas bi-dimensionais são propostos e a taxa de acertos resultante é comparada com aquela obtida para histogramas uni-dimensionais. Os experimentos mostraram que os histogramas bi-dimensionais fornecem uma taxa de acertos ligeiramente maior a um custo de hardware equivalente. Para a classificação baseada em histogramas bi-dimensionais, os seguintes parâmetros foram avaliados: tamanho do conjunto de treino, robustez ao ruído e relação entre número de amostras e taxa de acertos. Para as condições assumidas nos experimentos conduzidos, um tamanho do conjunto de treino de 256 amostras forneceram a melhor relação entre a taxa de acertos e recursos de hardware. Em relação à robustez ao ruído, os experimentos mostraram que a taxa de acertos global é melhor adaquando as SVMs são treinadas para toda a faixa de relação sinal-ruído na qual atuarão, ao invés de treinadas para um valor específico de relação sinal-ruído. Finalmente, percebeu-se que a taxa de acertos aumenta drasticamente quando o número de amostras para classificação é maior.<br> / Abstract: The fast expansion of wireless communications made the radio frequency spectrum a quite scarce resource. Cognitive radio emerges as a viable solution to circumvent this difficulty. In the context of cognitive radio, Spectrum Sensing (SS) plays a fundamental role. In particular, Automatic Modulation Classification (AMC) is one of the most computational demanding blocks within SS. Current research in AMC focuses on developing fast and accurate methods that are able to achieve the throughput required by contemporary applications. Some recent works have proposed the use of histrograms of the input signal as classification parameters, and Support Vector Machine (SVM) as a classification technique. This work presents an evaluation of such approach looking for designing efficient dedicated hardware architectures for AMC. In the first part of the work, hardware solutions for classifying multiple classes using SVM are designed and evaluated. The proposed "enhancedone against all" scheme presented up to 162% higher accuracy than the commonly used "one against one" scheme, while consuming 30:2% less energy per classification. In the second part of the work, the use of histograms along with SVM is evaluated as a blind classification technique. This was accomplished by conducting experiments assuming that the receiver does not know the transmitted baud rate, in opposition to the correlated work. As another novelty, two-dimensional histograms are proposed and the resulting accuracy is compared to that obtained from one-dimensional histograms. The experiments showed that two-dimensional histograms provide slightly higher accuracy at equivalent hardware costs. The following parameters were evaluated for two-dimensional histogram-based classification: training set size, robustness to noise and relation between number of samples and hit rate. For the conditions assumed in the conducted experiments, a training set size of 256 samples provided the best trade-off between accuracy and hardware resources. Concerning the robustness to noise, the experiments showed that the global accuracy is improved when SVMs are trained for the whole signal-to noise range that they are supposed to operate, instead of training to a specific signal-to-noise value. Finally, it has been noticed that accuracy is drastically improved when the number of samples for classification is increased.
5

Avaliação das ferramentas de controle de qualidade para pacientes submetidos ao IMRT / Evaluation tools of quality control for patients submitted to IMRT

Milton Lavor 07 April 2011 (has links)
Atualmente a radioterapia de intensidade modulada (IMRT) está sendo implementada em um número crescente de centros no Brasil. Como conseqüência disto, muitas instituições estão enfrentando o problema de executar um programa de controle de qualidade antes e durante a execução do IMRT na prática da rotina clínica. O objetivo deste trabalho é avaliar e propor uma metodologia para o controle de qualidade de tratamentos com IMRT. Uma câmara de ionização e um detector bidimensional foram utilizados para avaliar a dose absoluta total de todos os campos em um determinado ponto. A distribuição de dose relativa total de todos os campos foi medida com filmes radiocrômicos e um detector bidimensional em uma profundidade no objeto simulador. Uma comparação entre as distribuições de dose medidas e calculadas foi realizada usando o método do índice gama, avaliando o percentual de pontos que satisfazem os critérios de diferença dose de ±3% e distância de concordância de ±3 mm. Como resultado da dosimetria absoluta de 113 feixes de IMRT medidos com uma câmara de ionização e 81 feixes usando o detector bidimensional, foi proposto um nível de ação de cerca de ± 5% em relação ao sistema de planejamento e de tratamento para a verificação da dose em um único ponto na região de baixo gradiente de dose. A análise das medições com o detector bidimensional mostrou que o valor da função gama foi <1 para 97,7% dos dados e, para o filme, o valor da função gama foi <1 para 96,6% dos dados. Neste trabalho pode-se concluir que para uma entrega exata de dose em IMRT sliding-window com um colimador micro multilâminas, os parâmetros de dose total absoluta e distribuição de dose total relativa devem ser verificados por dosimetria absoluta e relativa respectivamente. / Intensity modulated radiation therapy (IMRT) is currently been implemented in a rapidly growing number of centers in Brazil. As consequence many institutions are now facing the problem of performing a comprehensive quality control program before and during the implementation of IMRT in the clinical routine practice. The aim of this work is to evaluate and propose a methodology for quality assurance in IMRT treatments. An ionization chamber and a two-dimensional array detector were performed to assess the absolute value of the total dose of all fields in one specific point. The relative total dose distribution of all fields was measured with a radiochromic film and a two-dimensional array at one depth in a phantom. A comparison between measured and calculated dose distributions was performed using the gamma-index method, assessing the percentage of points that meet the criteria of ±3% dose difference and ±3 mm distance to agreement. As a result of 113 tested IMRT beams using ionization chamber and 81 using two-dimensional array, the proposal was to take an action level of about ± 5% compared to the treatment planning systems and measurements, for the verification of the dose in a single point at the low gradient dose region. Analysis of the two-dimensional array measurements showed that the gamma value was <1 for 97.7% of the data and for the film the gamma value was <1 for 96.6% of the data. This can be concluded that for an accurate delivery of dose in sliding-window IMRT with micro multileaf collimator, the absolute value of the total dose and the relative total dose distribution should be checked by absolute and relative dosimetry respectively.
6

Avaliação da ototoxicidade em pacientes portadores de meduloblastoma submetidos à radioterapia com reforço de dose com intensidade modulada do feixe (IMRT) / Ototoxicity evaluation in medulloblastoma patients submitted to boost radiotherapy with intensity-modulated radiation therapy (IMRT)

Vieira, Wilson Albieri 01 December 2011 (has links)
INTRODUÇÃO: A combinação de radioterapia e altas doses de cisplatina no tratamento do meduloblastoma tem se mostrado causa de importante ototoxicidade. Com a introdução da técnica de intensidade modulada do feixe (IMRT), tornou-se possível diminuir a dose média de radiação no aparelho auditivo. OBJETIVOS: O objetivo é determinar se com a radioterapia com reforço de dose com IMRT, é possível atingir índices menores de perda auditiva e se há um limite de dose no ouvido para a mesma. Analisar também se o volume de ouvido contornado durante o planejamento inverso influencia o resultado. MÉTODO: Quarenta e um pacientes com meduloblastoma (idade mediana, 10 anos) com audição normal ao início da radioterapia com IMRT foram avaliados retrospectivamente. O último seguimento e a última audiometria realizada após o término da radioterapia foram considerados. A função auditiva foi graduada em uma escala de 0 a 4 de acordo com os critérios de toxicidade do Pediatric Oncology Group (POG). As doses mínima, máxima, média e mediana recebidas pelo aparelho auditivo, bem como o volume contornado no planejamento do IMRT foram correlacionados com o grau de função auditiva. Foi realizada análise univariada e multivariada dos dados. RESULTADOS: O seguimento mediano foi de 41 meses (12,8 a 71) para avaliação audiométrica e 44 meses (14-72) para a sobrevida global. As doses medianas mínima, máxima, média e mediana recebidas pelo aparelho auditivo foram respectivamente de: 3785 (589,4 a 4758,2), 4832,5 (3724 a 5447,9), 4366,5 (2808,5 a 5097,3) e 4360,5 (2878 a 5031,1). Sete pacientes (17%) apresentaram perda auditiva graus 3 e 4. A análise univariada entre as variáveis não mostrou diferença com significância estatística, exceto para a dose de cisplatina (P < 0,03). Na análise multivariada com regressão logística, a dose mediana no aparelho auditivo foi um fator significativo para a perda auditiva graus 3 e 4 (P < 0,01), ao passo que a dose cumulativa de cisplatina apresentou tendência à perda graus 3 e 4 (P = 0,075). Não houve correlação entre o volume contornado no planejamento a perda auditiva. Perda auditiva graus 3 e 4 foi incomum com dose mediana no aparelho auditivo menor que 42 Gy (P = 0,063) e dose cumulativa de cisplatina abaixo de 375 mg/m² (P < 0,01). Nenhum paciente que recebeu carboplatina em substituição à cisplatina apresentou perda auditiva grave. Não houve associação, com significância estatística, entre as variáveis analisadas e a ototoxicidade, quando estes pacientes foram excluídos da análise. Quatro pacientes morreram e dois apresentaram recidiva no momento do estudo, levando a uma sobrevida global de 90% e uma sobrevida livre de doença de 85% em 44 meses. CONCLUSÕES: Os resultados mostram que o tratamento com IMRT leva a uma baixa taxa de perda auditiva grave, mesmo com um seguimento maior, o que é consistente com outros estudos. Acreditamos ser seguro contornar somente a cóclea e que uma dose mediana para a mesma deve ser mantida abaixo de 42 Gy. A quimioterapia com cisplatina continua a ter um papel importante no tratamento, no entanto a dose cumulativa não deve exceder 375 mg/m². A sobrevida foi impressionante neste estudo, uma vez que 21 (51,2%) foram classificados como alto risco / INTRODUCTION: The combination of radiation therapy and cisplatin chemotherapy for the treatment of medulloblastoma is a known cause of important ototoxicity. With the introduction of intensity-modulated radiation therapy (IMRT), it became possible to deliver less radiation to the auditory apparatus. PURPOSE: To determine if boost radiotherapy with IMRT can achieve a lower rate of hearing loss and if theres a cutoff dose for it. Also, to analyze whether the auditory apparatus volume contoured in inverse planning influences the outcome. METHODS: Forty-one pediatric medulloblastoma patients (median age, 10 years) with normal hearing at the time of radiation with IMRT were retrospectively evaluated. The last audiogram and follow-up from the completion of radiation were considered. Hearing function was graded on a scale 0 to 4 according to Pediatric Oncology groups toxicity criteria. Minimum, maximum, mean and median doses to the inner ear and its volume contoured in IMRT planning, as well the cisplatin dose were recorded and correlated with hearing function. Univariate and multivariate data analysis were performed. RESULTS: The median follow-up was 41 months (range 12.8-71.0 months) for audiometric evaluation and 44 months (range 14-72 months) for survival. Median doses for minimum, maximum, mean and median in the inner ear were respectively: 3785 (range, 589.4 to 4758.2), 4832.5 (range 3724 to 5447.9), 4366.5 (range 2808.5 to 5097,3) and 4360,5 (range 2878 to 5031,1). Seven patients (17%) have experienced Grade 3 or 4 hearing loss. Univariate analysis showed no difference among the variables with statistical significance, except for cisplatin dose (P < 0.03). In multivariate analysis with logistic regression, median dose in inner ear was a significant factor for hearing loss grade 3 or 4 (P < 0,01), meanwhile cisplatin dose had a trend to hearing loss grade 3 or 4 (P = 0.075). There was no relationship between the auditory apparatus volume contoured in planning and hearing loss. Grade 3 or 4 hearing loss were uncommon with median dose to the inner ear bellow 42 Gy (P = 0.063) and cisplatin dose less than 375 mg/m² (P < 0.01). None of the patients who received carboplatin in lieu of cisplatin had severe hearing loss. There was no statistically significant association between ototoxicity and the variables, when these patients were excluded from the analysis. Four patients died and two have recurred at the time of the study with a 90% overall survival rate and 85% disease free survival in 44 months. CONCLUSIONS: Our findings shows that IMRT treatment leads to a low rate of serious hearing loss even with a longer follow-up, which is consistent with others trials. We believe that is safe to contour only the cochlea and that a median dose to it should be kept below 42Gy. Cisplatin chemotherapy continues to have an important role in treatment, however doses should not exceed 375 mg/m². Survival rates were impressing in this trial given the fact that 21 (51.2%) patients were classified as high risk
7

Dosimetria gel no controle de qualidade tridimensional em tratamento de radioterapia com intensidade modulada e técnica SMART (Simultaneous Modulated Accelerated Radiation Therapy) / Gel Dosimetry in Tridimensional Quality Control Radiotherapy Treatments with Intensity Modulated and SMART Technique (Simultaneous Modulated Accelerated Radiation Therapy).

Acurio, Erick Sebastian Rundo 28 November 2016 (has links)
A radioterapia com intensidade modulada de feixe (IMRT) possibilitou a realização de tratamentos de múltiplos alvos simultaneamente em um esquema de tratamento acelerado conhecido como SMART (Simultaneous Modulated Accelerated Radiation Therapy). Estes tratamentos requerem um rigoroso controle de qualidade (QA) que deveria ser realizado, idealmente, em três dimensões. Uma potencial ferramenta para dosimetria tridimensional (3D) é o uso de gel polimérico associado à leitura de doses com Imagens de Ressonância Magnética Nuclear (IRMN). Neste trabalho, a dosimetria 3D com o gel MAGIC-f foi aplicada no CQ de 10 planejamentos radioterápicos usando a técnica SMART. Inicialmente, as distribuições de dose dos planejamentos avaliados foram recalculadas na geometria do simulador baseadas em sua tomogra_a computadorizada. Todos os planejamentos utilizados foram aprovados previamente no QA convencional pontual e planar, o que validou a distribuição de dose do sistema de planejamento (TPS) para comparação com a dosimetria gel. Os simuladores foram irradiados com os planejamentos estabelecidos e as distribuições de dose foram obtidas através da relaxometria em IRMN. A comparação das distribuições de dose calculadas pelo TPS e as medidas no gel foi feita pela análise gama (3%/3mm) e pela comparação entre os histogramas dose-volume (DVHs) calculados e medidos para dois volumes criados nas regiões equivalentes aos volumes alvo de tratamento. Esses resultados evidenciam o potencial do uso da dosimetria gel polimérica no QA 3D de planejamentos de IMRT com a técnica SMART, fornecendo informação completa 3D da dose absorvida em cada volume alvo planejado, desde que realizada seguindo os protocolos pré-estabelecidos. / Intensity Modulated Radiation Therapy (IMRT) treatments in the radiotherapy practice made possible the simultaneously treatment of multiple targets at an accelerated treatment regimen, this scheme is known as Simultaneous Modulated Accelerated Radiation Therapy (SMART). These treatments require a strict quality control (QC) that should be done, ideally, in three dimensions. A potential tool for tridimensional dosimetry (3D) is the use of polymeric gel with Nuclear Magnetic Resonance Images (NMRI). In this paper, the 3D dosimetry with MAGIC-f gel was applied in 10 QC radiotherapy planning using the SMART technique. Initially, the dose distributions of assessed plans were remeasured in simulator geometry based on a CT scan. All plans used were previously approved in punctual and planar conventional CQ, which validated the dose distribution planning system (TPS) for comparison with the gel dosimetry. The simulators were irradiated with established schedules and dose distributions were obtained by relaxometry in NMRI. The comparison of dose distributions calculated by TPS and measured in the gel was made by gamma analysis (3% / 3mm) and by comparing the dose-volume histograms (DVHs) calculated and measured for two volumes created in the equivalent regions to target volumes of treatment. These results highlight the potential use of the polymer gel dosimetry in IMRT planning 3D CQ with SMART technique, providing complete 3D information of the absorbed dose in each target volume planned, if carried out following the pre-established protocols.
8

Avaliação da ototoxicidade em pacientes portadores de meduloblastoma submetidos à radioterapia com reforço de dose com intensidade modulada do feixe (IMRT) / Ototoxicity evaluation in medulloblastoma patients submitted to boost radiotherapy with intensity-modulated radiation therapy (IMRT)

Wilson Albieri Vieira 01 December 2011 (has links)
INTRODUÇÃO: A combinação de radioterapia e altas doses de cisplatina no tratamento do meduloblastoma tem se mostrado causa de importante ototoxicidade. Com a introdução da técnica de intensidade modulada do feixe (IMRT), tornou-se possível diminuir a dose média de radiação no aparelho auditivo. OBJETIVOS: O objetivo é determinar se com a radioterapia com reforço de dose com IMRT, é possível atingir índices menores de perda auditiva e se há um limite de dose no ouvido para a mesma. Analisar também se o volume de ouvido contornado durante o planejamento inverso influencia o resultado. MÉTODO: Quarenta e um pacientes com meduloblastoma (idade mediana, 10 anos) com audição normal ao início da radioterapia com IMRT foram avaliados retrospectivamente. O último seguimento e a última audiometria realizada após o término da radioterapia foram considerados. A função auditiva foi graduada em uma escala de 0 a 4 de acordo com os critérios de toxicidade do Pediatric Oncology Group (POG). As doses mínima, máxima, média e mediana recebidas pelo aparelho auditivo, bem como o volume contornado no planejamento do IMRT foram correlacionados com o grau de função auditiva. Foi realizada análise univariada e multivariada dos dados. RESULTADOS: O seguimento mediano foi de 41 meses (12,8 a 71) para avaliação audiométrica e 44 meses (14-72) para a sobrevida global. As doses medianas mínima, máxima, média e mediana recebidas pelo aparelho auditivo foram respectivamente de: 3785 (589,4 a 4758,2), 4832,5 (3724 a 5447,9), 4366,5 (2808,5 a 5097,3) e 4360,5 (2878 a 5031,1). Sete pacientes (17%) apresentaram perda auditiva graus 3 e 4. A análise univariada entre as variáveis não mostrou diferença com significância estatística, exceto para a dose de cisplatina (P < 0,03). Na análise multivariada com regressão logística, a dose mediana no aparelho auditivo foi um fator significativo para a perda auditiva graus 3 e 4 (P < 0,01), ao passo que a dose cumulativa de cisplatina apresentou tendência à perda graus 3 e 4 (P = 0,075). Não houve correlação entre o volume contornado no planejamento a perda auditiva. Perda auditiva graus 3 e 4 foi incomum com dose mediana no aparelho auditivo menor que 42 Gy (P = 0,063) e dose cumulativa de cisplatina abaixo de 375 mg/m² (P < 0,01). Nenhum paciente que recebeu carboplatina em substituição à cisplatina apresentou perda auditiva grave. Não houve associação, com significância estatística, entre as variáveis analisadas e a ototoxicidade, quando estes pacientes foram excluídos da análise. Quatro pacientes morreram e dois apresentaram recidiva no momento do estudo, levando a uma sobrevida global de 90% e uma sobrevida livre de doença de 85% em 44 meses. CONCLUSÕES: Os resultados mostram que o tratamento com IMRT leva a uma baixa taxa de perda auditiva grave, mesmo com um seguimento maior, o que é consistente com outros estudos. Acreditamos ser seguro contornar somente a cóclea e que uma dose mediana para a mesma deve ser mantida abaixo de 42 Gy. A quimioterapia com cisplatina continua a ter um papel importante no tratamento, no entanto a dose cumulativa não deve exceder 375 mg/m². A sobrevida foi impressionante neste estudo, uma vez que 21 (51,2%) foram classificados como alto risco / INTRODUCTION: The combination of radiation therapy and cisplatin chemotherapy for the treatment of medulloblastoma is a known cause of important ototoxicity. With the introduction of intensity-modulated radiation therapy (IMRT), it became possible to deliver less radiation to the auditory apparatus. PURPOSE: To determine if boost radiotherapy with IMRT can achieve a lower rate of hearing loss and if theres a cutoff dose for it. Also, to analyze whether the auditory apparatus volume contoured in inverse planning influences the outcome. METHODS: Forty-one pediatric medulloblastoma patients (median age, 10 years) with normal hearing at the time of radiation with IMRT were retrospectively evaluated. The last audiogram and follow-up from the completion of radiation were considered. Hearing function was graded on a scale 0 to 4 according to Pediatric Oncology groups toxicity criteria. Minimum, maximum, mean and median doses to the inner ear and its volume contoured in IMRT planning, as well the cisplatin dose were recorded and correlated with hearing function. Univariate and multivariate data analysis were performed. RESULTS: The median follow-up was 41 months (range 12.8-71.0 months) for audiometric evaluation and 44 months (range 14-72 months) for survival. Median doses for minimum, maximum, mean and median in the inner ear were respectively: 3785 (range, 589.4 to 4758.2), 4832.5 (range 3724 to 5447.9), 4366.5 (range 2808.5 to 5097,3) and 4360,5 (range 2878 to 5031,1). Seven patients (17%) have experienced Grade 3 or 4 hearing loss. Univariate analysis showed no difference among the variables with statistical significance, except for cisplatin dose (P < 0.03). In multivariate analysis with logistic regression, median dose in inner ear was a significant factor for hearing loss grade 3 or 4 (P < 0,01), meanwhile cisplatin dose had a trend to hearing loss grade 3 or 4 (P = 0.075). There was no relationship between the auditory apparatus volume contoured in planning and hearing loss. Grade 3 or 4 hearing loss were uncommon with median dose to the inner ear bellow 42 Gy (P = 0.063) and cisplatin dose less than 375 mg/m² (P < 0.01). None of the patients who received carboplatin in lieu of cisplatin had severe hearing loss. There was no statistically significant association between ototoxicity and the variables, when these patients were excluded from the analysis. Four patients died and two have recurred at the time of the study with a 90% overall survival rate and 85% disease free survival in 44 months. CONCLUSIONS: Our findings shows that IMRT treatment leads to a low rate of serious hearing loss even with a longer follow-up, which is consistent with others trials. We believe that is safe to contour only the cochlea and that a median dose to it should be kept below 42Gy. Cisplatin chemotherapy continues to have an important role in treatment, however doses should not exceed 375 mg/m². Survival rates were impressing in this trial given the fact that 21 (51.2%) patients were classified as high risk
9

Otimização de protocolos de abdômen-pelve em tomografia computadorizada multislice utilizando associações de avaliações subjetivas e objetivas

Maués, Nadine Helena Pelegrino Bastos. January 2017 (has links)
Orientador: Diana Rodrigues de Pina / Resumo: A tomografia computadorizada (TC) é amplamente utilizada no diagnóstico e estadiamento de patologias da região de abdômen-pelve devido a sua alta sensibilidade e especificidade. A possibilidade de adquirir maior número de imagens em menor tempo e a maior disponibilidade de equipamentos levaram a um aumento significativo dos exames de TC e consequente aumento das doses efetivas globais fornecidas por esta modalidade. Desta forma, foram desenvolvidas ferramentas que buscam reduzir as doses de radiação dos exames sem perda da qualidade da imagem. Uma destas ferramentas é a modulação automática da corrente do tubo (automatic tube current modulation – ATCM), que permite a obtenção de exames que concordam com o princípio ALARA (as low as reasonably achievable). O objetivo deste estudo foi avaliar a qualidade da imagem e as doses de radiação de diferentes protocolos de TC de abdômen-pelve com a ferramenta ATCM. Foram avaliados cinco protocolos de TC de abdômen-pelve com a ferramenta ATCM em dois tomógrafos distintos, um 16-canais e um 64 canais. Foi utilizado um fantoma antropomórfico para avaliações dosimétricas e um fantoma analítico para avaliações objetivas de qualidade da imagem. Para a análise subjetiva da qualidade da imagem, foram utilizados 15 exames retrospectivos de pacientes submetidos a TC de abdômen-pelve. Estes exames foram avaliados por um radiologista com experiência na área de tomografia de abdômen. As três análises forneceram informações que possibilitaram a escol... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
10

Arquitetura escolar Infantil modulada e flex?vel

Marcelino, Marcolina Maria de Oliveira Pires 29 May 2014 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2015-10-23T12:19:37Z No. of bitstreams: 1 MarcolinaMariaDeOliveiraPiresMarcelino_DISSERT.pdf: 6091848 bytes, checksum: 8fff8dbf4a84392e7ad8c3ab74974747 (MD5) / Approved for entry into archive by Elisangela Moura (lilaalves@gmail.com) on 2015-10-23T13:02:35Z (GMT) No. of bitstreams: 1 MarcolinaMariaDeOliveiraPiresMarcelino_DISSERT.pdf: 6091848 bytes, checksum: 8fff8dbf4a84392e7ad8c3ab74974747 (MD5) / Made available in DSpace on 2015-10-23T13:02:35Z (GMT). No. of bitstreams: 1 MarcolinaMariaDeOliveiraPiresMarcelino_DISSERT.pdf: 6091848 bytes, checksum: 8fff8dbf4a84392e7ad8c3ab74974747 (MD5) Previous issue date: 2014-05-29 / Com o passar dos anos, a pol?tica do governo federal ? utilizar projetos padr?es para edif?cios escolares, na tentativa de agilizar as obras e reduzir d?ficit de vagas para o ensino. No munic?pio de Natal as escolas infantis destinadas a crian?as de 0 a 6 anos, s?o denominadas Centro Municipal de Ensino Infantil (CMEI). As novas edifica??es s?o implantadas atrav?s de financiamento junto ao Governo Federal pelo Programa PROINF?NCIA. Este disponibiliza tr?s tipos de projeto: O ?tipo A? deve ser fornecido pelo munic?pio interessado e aprovado pelo MEC. O ?tipo B? ? projeto padr?o com capacidade para 120 alunos em tempo integral ou 240 em dois turnos e terreno com dimens?es de 40 x 70m e ?tipo C? tamb?m projeto padr?o para 60 alunos em tempo integral ou 120 em dois turnos e terreno com dimens?es de 35 x 45m. Com a escassez de terreno com dimens?es maiores, algumas vezes ? implantado o ?tipo C? quando a necessidade ? pelo ?tipo B? devido ? oferta de vagas. Neste sentido, este estudo tem a inten??o de apresentar o anteprojeto de escola de educa??o infantil modulada e flex?vel com ?nfase no conforto dos usu?rios. Portanto foram realizados estudos de conceitos, arquitetura escolar, tecnologias de constru??o, estudos de refer?ncias e visitas ao CMEI Fernanda Jales (PROINF?NCIA ?tipo B?). No entanto a proposta sintetiza o anteprojeto por m?dulos podendo ser implantado na sua totalidade ou por partes de acordo com a necessidade e caracter?sticas do lote. / For many y ears, the federal government policy is to use project for in order to speed up the work for decreasing the elementary education deficit vacancy . In Natal municipality the schoolhouses for children, from 0 to 6 years of age are denom inated Muinicipality Centre for Elementary Education. The federal government provides capital for the news edifications by the program of government named PROINF?NCIA. This program embraces three types of projects. Type ?A? must be furnished by the interes ted municipality and approved by Education and Cultura Ministry. The type ?B? is standard plan with capability to 120 schoolchildren in full - time or 240 in two turns and ground plot measuring 40 x 70m and the ?type C? also a standart projects to 60 schoolc hildren in full - time or 120 in two turns and ground plot measuring 35 x 45m. Sometimes , due to scarcity of bigger ground plot s is the ?type C? instead of ?type B?, referring to offering vacancies. In this meaning, this study intend s to present the draft - project to elementary schoolhouse, modulated and flexible, emphasizing the children needs . Therefore, it was studied concept, school architecture, construction technology, reference study and visiting to MCEE Fernanda Jales (PROINF?NC IA ?tipo B?). However, the proposal synthesizes the draft - project by module, implanting in its totality or in parts, according to its necessity and lot cha racteristic.

Page generated in 0.0341 seconds