1

Aportació al control del convertidor CC/CA de tres nivells.

Alepuz Menéndez, Salvador Simón 13 December 2004 (has links)
La presente tesis estudia, propone y realiza sus principales aportaciones en el campo del control para el convertidor CC/CA de tres niveles, sobre la topología denominada Neutral-Point-Clamped, aunque se puede extender a otras topologías y/o número de niveles. Se presenta una metodología de modelado que emplea funciones de conmutación de fase, el operador de promediado y la transformación D-Q, tal que los modelos obtenidos en el dominio D-Q contienen una información completa sobre la dinámica del sistema. La estrategia de conmutación se puede entender como una extensión de la estrategia PWM senoidal de dos a tres niveles. Esta estrategia es simple y no realiza el control de ninguna de las variables del sistema. En esta tesis, el controlador se encarga de regular todas las variables del sistema, incluido el equilibrio del bus de continua. Este es un enfoque diferente del convencional, donde el equilibrio del bus de continua se consigue mediante la elección adecuada de los estados redundantes del convertidor en la estrategia de conmutación, mientras que el resto de variables se regulan a través del controlador. Para la realización del controlador, se propone la técnica de control lineal multivariable LQR (Linear Quadratic Regulator), complementada con la técnica de control no lineal adaptativo denominada programación de ganancia (Gain Scheduling). Se presenta, además, una metodología de cálculo del controlador. Este control es versátil, abierto y adaptable. En cualquier caso, el controlador se puede adaptar a las necesidades concretas de cada aplicación. El cálculo del controlador se realiza mediante simulación con MatLab-Simulink. Los modelos matemáticos que emplean las funciones de conmutación del convertidor son aquellos que ofrecen un mejor compromiso entre velocidad de simulación y precisión. Para validar el control propuesto, se ha diseñado y construido un equipo experimental donde el controlador se ha mostrado aplicable, útil y eficaz en la regulación de las distintas cargas y aplicaciones experimentadas, incluso con carga no lineal, bajo diferentes condiciones de trabajo y variables a controlar, tanto en régimen permanente como en procesos transitorios. La rapidez y calidad de la respuesta transitoria es comparable a la de otros sistemas de control publicados. Es especialmente interesante el excelente control conseguido del equilibrio del bus de continua. Además, la robustez del control permite cancelar el error estacionario aunque diferentes parámetros del sistema presenten desviaciones significativas respecto los valores esperados. El uso de la programación de ganancia junto con la técnica LQR se ha mostrado muy efectivo, puesto que permite realizar diferentes tipos de control. Se ha comprobado la congruencia entre simulaciones y resultados experimentales obtenidos, lo que valida los modelos de simulación empleados y el proceso de diseño del controlador mediante simulación. / This dissertation study, propose and carry out the main contributions in the field of three-level inverter control, using the topology Neutral-Point-Clamped, although results can be extended to other topologies and/or number of levels. A procedure for modelling is presented, based on line-switching functions, moving average operator and D-Q transformation. Then, the obtained models in D-Q frame contain complete information about system dynamics. Switching strategy is simple and can be considered as an extension of two-level sinusoidal PWM to three level. The system variables are not controlled by the switching strategy. In this work, all the system variables are controlled by the regulator, including DC-link balance. This control approach is different than the conventional one, where DC-link balance is achieved by means of a proper selection of redundant states in the switching strategy, and the other variables are controlled by the regulator. The regulator is based on the multivariable linear control technique LQR (Linear Quadratic Regulator), in combination with the non-linear adaptive control technique Gain Scheduling. Moreover, a methodology for the calculation of the controller is presented. This controller is versatile, open and adaptable. However, the controller can be built depending on the concrete specifications of each application. The controller is calculated by means of simulation using MatLab-Simulink. The mathematical models based on the switching functions of the converter give the best trade-off between simulation speed and precision. In order to validate the proposed controller, an experimental prototype has been designed and implemented. Experimental results show that the controller is useful and effective for the regulation of different loads and applications, even with non-linear loads, different operation points and variables to control, in steady-state and transitory operation. Dynamic response speed and quality are similar to other control systems in the literature. The DC-link balance control achieved is specially interesting. Furthermore, steady-state error is cancelled due to the robustness of the controller, even though significant deviation of different system parameters are present. The use of Gain-Scheduling in combination with LQR is effective, allowing the calculation of regulators with different control strategies. Good agreement between simulations and experimental results has been found. This result validates simulation models and the design method for the controller, based on simulations.
2

Architectures d'alimentation et de commande des actionneurs haute-vitesse connectés aux réseaux avioniques à tension variable / Electronic power supply and control architectures of a high speed actuator connected to variable voltage aircraft networks

Cuenot, Jérémy 25 October 2017 (has links)
La révolution technologique majeure des nouveaux aéronefs repose sur une électrification intensive de nombreux constituants de l'appareil et le fait que la vitesse des génératrices électriques n'est plus fixe mais variable. Cette nouvelle manière de générer la puissance électrique engendre des variations de tension sur les réseaux DC. De plus, pour accroître la compacité des Machines Synchrones à Aimants Permanents (MSAP) à puissance donnée, on augmente autant que possible leur vitesse d'entrainement, en les associant pour certaines applications à des réducteurs mécaniques. La variation du niveau de tension du bus DC alimentant une MSAP haute vitesse implique son dimensionnement afin d'assurer sa contrôlabilité sur toute la plage de vitesse reportant d'importantes contraintes sur l'onduleur de tension. Pour pallier ce problème, une solution consiste à intercaler un convertisseur DC/DC entre le filtre d'entrée et l'onduleur de tension pour maintenir la tension DC d'entrée de l'onduleur à une valeur adaptée au fonctionnement de la MSAP et optimiser son dimensionnement. Cependant, cette solution augmente l'ordre du système, ce qui accroît la complexité de son contrôle, accentuée par les contraintes liées à la nature haute-fréquence des MSAP considérées.Les travaux menés dans cette thèse concernent l'étude, l'optimisation et le contrôle des structures d'alimentation des actionneurs haute vitesse connectés aux réseaux DC avioniques à tension variable. Il en résulte que pour les applications avioniques considérées, ces architectures d'alimentation intégrant un convertisseur DC/DC supplémentaire permettent de réduire sa masse et son volume sans dégrader le rendement global de la chaîne de conversion notamment avec les convertisseurs à source impédante qui permettent de supprimer structurellement les ondulations de courant en entrée du convertisseur. De plus, des stratégies de commande Pulse Amplitude Modulation employées avec des architectures de contrôle non-linéaires (platitude, passivité) permettent d'assurer le contrôle de ces MSAP haute-vitesse tout en assurant leur stabilité sur toute la plage de fonctionnement / The main technological revolution of the new aircrafts is based on intensive electrification of many components of the aircraft. Moreover, the speed of electrical generators is no longer fixed but variable. This new way of generating electrical power generates voltage variations on DC networks. Besides, to increase the compactness of the Permanent Magnet Synchronous Machines (PMSM) at a given power, their mechanical speed is increased as much as possible by combining them with mechanical reducers for certain applications. The variation of the voltage level of the DC bus supplying a high-speed PMSM implies its sizing in order to ensure its controllability over the entire speed range which carries significant stresses on the Voltage Source Inverter (VSI). To solve this problem, one solution consists in adding an extra DC / DC converter between the input filter and the VSI to maintain the inverter input voltage at a value adapted to the operating point of the PMSM and to optimize its dimensioning. However, this solution increases the order of the system, which increases the complexity of its control, accentuated by the constraints related to the high-frequency nature of the PMSMs considered. The work carried out in this thesis concerns the study, the optimization and the control of the power supply architecture of the high-speed actuators connected to variable-voltage avionic DC networks. As a result, for the avionics applications considered, these power supply architectures integrating an additional DC / DC converter make it possible to reduce the mass and the volume of the power supply structure without degrading the overall efficiency of the conversion chain, in particular by using the impedance-source converters which allow to cancel the DC input current ripples. In addition, Pulse Amplitude Modulation (PAM) control strategies used with non-linear control architectures (flatness, passivity) make it possible to control these high-speed PMSMs while ensuring their stability over the entire operating range
3

Autonomní záložní zdroj 230V/50Hz/300VA s bateriovým napájením 12V / Back-up power supply 230V/50Hz/300VA with a battery supply 12V

Snítilý, David January 2008 (has links)
The aim of this project is to describe, design and create a converter from 12V DC to 230 VRMS. The power of this device is about 500W. The device consists of two main converters. The first one is step-up DC/DC converter and the other is DC/AC inverter. Step-up converter is designed as a resonant converter. It is useful for pushing down losses in semiconductors and inceasing efficiency. The inverter is changing DC voltage from the first converter to AC voltage. Control of this device is realized with DSP Motorola. This device should be used mainly for supply common devices up to 500W. Main usage is planed in a car or to another place where is not posible to connect some device to plug.