• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 30
  • 30
  • 23
  • 23
  • 17
  • 17
  • 14
  • 13
  • 11
  • 11
  • 10
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

O uso de agentes desinfetantes em materiais de moldagem: sua influência na estabilidade dimensional linear

Silva, Sávio Marcelo Leite Moreira da 19 February 2003 (has links)
O objetivo deste trabalho foi avaliar a estabilidade dimensional das siliconas de condensação pesada e leve para moldagem odontológica, quando imersas em solução desinfetante por 10 e 20 minutos, relacionando a importância da biossegurança no manuseio destes materiais. Os materiais de moldagem testados foram: Optosil Confort e Xantopren VL Plus; e as soluções desinfetantes foram o hipoclorito de sódio a 1% (Solução de Milton) e o glutaraldeído a 2% (Glutaron II). Impressões foram obtidas através de moldeiras perfuradas de aço inoxidável, de acordo com a especificação n.º 19 da ADA, perfazendo um total de 50 moldagens, que foram executadas pela técnica em passo único, de acordo com as especificações do fabricante. Para assegurar a completa polimerização o material foi removido após 7 minutos e submetido à imersão nas soluções desinfetantes nos tempos determinados, sendo um grupo controle representado por moldes sem imersão. Depois de removidos das soluções, os corpos de prova foram lavados em água corrente por 15 segundos, secos e medidos 3 vezes cada para registro da média, usando um microscópio óptico, com precisão de 0,001 mm. A análise de variância a dois critérios, com nível de significância de 5%, mostrou que as diferenças nas dimensões lineares da silicona testada não são estatisticamente significantes (p>0,05) após sua imersão em solução de hipoclorito de sódio a 1% e glutaraldeído a 2% até 20 minutos. Os resultados indicaram que a combinação testada de material de moldagem e solução desinfetante pode seguramente ser empregada na clínica odontológica para o controle de infecção e segurança da equipe de saúde bucal. / The purpose of this study was to evaluate the dimensional stability of condensation silicone rubber heavy and light body after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Confort e Xantopren VL Plus and the disinfectants solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, performed a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete polymerization and then immersed in the solutions. Impressions with no treatment composed the control group. After these steps, impressions were taken out the solution and rinsed in running water and air dried. Three dimensional measurements were calculated, using an optic microscope graduated at 0,001 mm. The two- way ANOVA indicated no differences (p>0.05) for any combination between variables. The results have shown that the solution studied can be safety used to disinfect condensation silicon in clinical prosthodontic procedures.
2

Fidelidade de Troquéis de Gesso, Obtidos a Partir de Moldes de Vários Elastômeros, Através de Duas Diferentes Técnicas de Moldagem.

Marchese, Marco Polo 03 August 1999 (has links)
As restaurações fixas são rotineiramente fabricadas sobre um modelo de gesso, obtidos a partir do molde de um dente preparado. A precisão na adaptação destas é influênciada diretamente pelas propriedades dos materiais de moldagem empregado. Qualquer que seja o elastomêro eleito, o método mais confiável para se avaliar o seu desempenho em conduzir a modelos de gesso fiéis, parece ser aquele no qual é empregado um coroa-padrão que se adapta com precisão a um troquel apropriado. Este trabalho tem por objetivo avaliar se dentre as técnicas da dupla moldagem (com alívio de 1 e 2 mm) e a do casquete, existe uma mais adequada ou se ambas apresentam adequações suficiente e semelhantes. Foram empregados cinco elastômeros (Express, Impregum F, Imprint, Permlastic e President), os moldes foram obtidos empregando-se um dispositivo de moldagem idealizado por ARAÚJO e JÖRGENSEN6 e vazados com gesso especial tipo IV (Vel-Mix). A coroa-padrão foi posicionada nos troquéis e avaliada, quanto à sua precisão de adaptação, em um microscópio de medição de profundidade. Os resultados estatístico mostraram que a técnica do casquete apresentou melhores resultados para os materiais Impregum F e Imprint, vindos a seguir o Express e o President (ambos com alívio de 2 mm) e o Express (alívio de 1 mm); o Permlastic e o Express, na técnica do casquete, apresentaram piores resultados que os anteriores, mas semelhantes entre si, sendo o President (casquete) semelhante à este último; o President (alívio de 1 mm), foi o que apresentou pior resultado. / Fixed restorations are usually produced on gypsum dies obtained from a prepared tooth mold and its precise adaptation is directly influenced by the properties of the impression materials. The objective of this study was to compare the performance of five impression materials and different methods of impression. Materials were tested using the putty-wash method being the first impression realeased in 1 or 2 mm (for Express and President) and the individual resin tray shell (Express, Impregum F, Imprint, Permlastic e Predident). The deviced used by ARAÚJO; JÖRGENSEN6 and the Vel-Mix (type IV) gypsum were used. The adaptation of one standard-crown to the dies was analysed with a depth measuring microscope. The results showed that Impregum F and Imprint (with a shell) gave the best results, followed by Express and President (putty/wash – 2 mm) and Express (putty/wash – 1 mm). The results with Permlastic and Express (shell) were less satisfactory and the difference between them wasn’t statistically significant. Express (shell) was not statistically different from the President (shell), and the worse result was given by the President (putty/wash - 1 mm) when compared to all the others.
3

Fidelidade de Troquéis de Gesso, Obtidos a Partir de Moldes de Vários Elastômeros, Através de Duas Diferentes Técnicas de Moldagem.

Marco Polo Marchese 03 August 1999 (has links)
As restaurações fixas são rotineiramente fabricadas sobre um modelo de gesso, obtidos a partir do molde de um dente preparado. A precisão na adaptação destas é influênciada diretamente pelas propriedades dos materiais de moldagem empregado. Qualquer que seja o elastomêro eleito, o método mais confiável para se avaliar o seu desempenho em conduzir a modelos de gesso fiéis, parece ser aquele no qual é empregado um coroa-padrão que se adapta com precisão a um troquel apropriado. Este trabalho tem por objetivo avaliar se dentre as técnicas da dupla moldagem (com alívio de 1 e 2 mm) e a do casquete, existe uma mais adequada ou se ambas apresentam adequações suficiente e semelhantes. Foram empregados cinco elastômeros (Express, Impregum F, Imprint, Permlastic e President), os moldes foram obtidos empregando-se um dispositivo de moldagem idealizado por ARAÚJO e JÖRGENSEN6 e vazados com gesso especial tipo IV (Vel-Mix). A coroa-padrão foi posicionada nos troquéis e avaliada, quanto à sua precisão de adaptação, em um microscópio de medição de profundidade. Os resultados estatístico mostraram que a técnica do casquete apresentou melhores resultados para os materiais Impregum F e Imprint, vindos a seguir o Express e o President (ambos com alívio de 2 mm) e o Express (alívio de 1 mm); o Permlastic e o Express, na técnica do casquete, apresentaram piores resultados que os anteriores, mas semelhantes entre si, sendo o President (casquete) semelhante à este último; o President (alívio de 1 mm), foi o que apresentou pior resultado. / Fixed restorations are usually produced on gypsum dies obtained from a prepared tooth mold and its precise adaptation is directly influenced by the properties of the impression materials. The objective of this study was to compare the performance of five impression materials and different methods of impression. Materials were tested using the putty-wash method being the first impression realeased in 1 or 2 mm (for Express and President) and the individual resin tray shell (Express, Impregum F, Imprint, Permlastic e Predident). The deviced used by ARAÚJO; JÖRGENSEN6 and the Vel-Mix (type IV) gypsum were used. The adaptation of one standard-crown to the dies was analysed with a depth measuring microscope. The results showed that Impregum F and Imprint (with a shell) gave the best results, followed by Express and President (putty/wash – 2 mm) and Express (putty/wash – 1 mm). The results with Permlastic and Express (shell) were less satisfactory and the difference between them wasn’t statistically significant. Express (shell) was not statistically different from the President (shell), and the worse result was given by the President (putty/wash - 1 mm) when compared to all the others.
4

O uso de agentes desinfetantes em materiais de moldagem: sua influência na estabilidade dimensional linear

Sávio Marcelo Leite Moreira da Silva 19 February 2003 (has links)
O objetivo deste trabalho foi avaliar a estabilidade dimensional das siliconas de condensação pesada e leve para moldagem odontológica, quando imersas em solução desinfetante por 10 e 20 minutos, relacionando a importância da biossegurança no manuseio destes materiais. Os materiais de moldagem testados foram: Optosil Confort e Xantopren VL Plus; e as soluções desinfetantes foram o hipoclorito de sódio a 1% (Solução de Milton) e o glutaraldeído a 2% (Glutaron II). Impressões foram obtidas através de moldeiras perfuradas de aço inoxidável, de acordo com a especificação n.º 19 da ADA, perfazendo um total de 50 moldagens, que foram executadas pela técnica em passo único, de acordo com as especificações do fabricante. Para assegurar a completa polimerização o material foi removido após 7 minutos e submetido à imersão nas soluções desinfetantes nos tempos determinados, sendo um grupo controle representado por moldes sem imersão. Depois de removidos das soluções, os corpos de prova foram lavados em água corrente por 15 segundos, secos e medidos 3 vezes cada para registro da média, usando um microscópio óptico, com precisão de 0,001 mm. A análise de variância a dois critérios, com nível de significância de 5%, mostrou que as diferenças nas dimensões lineares da silicona testada não são estatisticamente significantes (p>0,05) após sua imersão em solução de hipoclorito de sódio a 1% e glutaraldeído a 2% até 20 minutos. Os resultados indicaram que a combinação testada de material de moldagem e solução desinfetante pode seguramente ser empregada na clínica odontológica para o controle de infecção e segurança da equipe de saúde bucal. / The purpose of this study was to evaluate the dimensional stability of condensation silicone rubber heavy and light body after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Confort e Xantopren VL Plus and the disinfectants solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, performed a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete polymerization and then immersed in the solutions. Impressions with no treatment composed the control group. After these steps, impressions were taken out the solution and rinsed in running water and air dried. Three dimensional measurements were calculated, using an optic microscope graduated at 0,001 mm. The two- way ANOVA indicated no differences (p>0.05) for any combination between variables. The results have shown that the solution studied can be safety used to disinfect condensation silicon in clinical prosthodontic procedures.
5

Influência de técnicas e materiais de moldagem, tempos e materiais de vazamento na exatidão tridimensional de modelos /

Messias, Aion Mangino. January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo analisou a exatidão de modelos totais de gesso, obtidos a partir de diferentes técnicas e materiais de moldagem, tempos e materiais de vazamento, levando em consideração as mensurações de área, volume e angulação nos eixos X, Y e Z de pontos de referência específicos em modelo mestre (baseline), moldes e, por posteriormente, em modelos de gesso de cada condição experimental. Foi utilizado um modelo mestre com preparos nos dentes 14, 16, 21 e 25, com demarcações pontuais em suas superfícies oclusais, que funcionavam como pontos de referência. Realizaram-se três técnicas de moldagem: (T1) mistura simultânea, (T2) reembasamento - alívio com filme de PVC e (T3) moldagem digital (escâner intra-oral) - Cerec Conect Omnicam (Sirona). Para cada técnica de moldagem/tempo de vazamento foram obtidos 8 moldes totais, por único operador calibrado (ICC=0,99), com moldeira metálica de estoque e silicone de condensação (Speedex; Coltène/Whaledent Inc.) ou adição (Express XT; 3M ESPE). Os vazamentos foram realizados com gessos tipo IV convencional (GC Fuji Rock EP - GC America) e de expansão nula (Zero Stone - Dentona AG). Nos moldes com silicone de condensação o gesso foi vazado após 30 minutos, 3 ou 7 dias. Nos moldes em silicone de adição os modelos foram obtidos após 2 horas, 3, 7 ou 15 dias. Para a análise tridimensional, utilizou-se software para gerenciamento de imagens e análise das malhas tridimensionais (Rhinoceros - versão 5.3.2) obtidas com escâner óptico de bancada (R... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study analyzed the accuracy of total gypsum casts obtained from different casting techniques and materials, casting times and materials, taking into account the measurements of area, volume and angulation in the X, Y and Z axes of reference points specific master model (baseline), in the impression and, later, in the gypsum casts of each experimental condition. A master model was used with teeth 14, 16, 21 and 25, with punctual demarcations on its occlusal surfaces, which functioned as reference points. Three impression techniques were performed: (T1) simultaneous mixing, (T2) relining-relief with PVC film and (T3) chairside digital impression - Cerec Conect Omnicam (Sirona). For each impression technique / casting time, 8 total impression were obtained by single calibrated operator (ICC = 0.99), with metal stock tray and condensation silicone (Speedex; Coltène / Whaledent Inc.) or addition (Express XT 3M ESPE). The gypsum casts pouring process were performed with type IV conventional gypsum (GC Fuji Rock EP - GC America) and zero expansion one (Zero Stone - Dentona AG). For impressions with condensation silicone the cast was poured after 30 minutes, 3 or 7 days. For the addition silicone impressions, the gypsum casts were obtained after 2 hours, 3, 7 or 15 days. For the three-dimensional analysis, a software was used to manage threedimensional images (Rhinoceros - version 5.3.2) allowing the investigation of virtual images (three-dimensional meshes) made with an optical... (Complete abstract click electronic access below) / Doutor
6

Influência de técnicas de moldagem com e sem casquetes na exatidão dimensional de modelos de gesso e adaptação marginal de infraestruturas em zircônia /

Silva, Stephania Caroline Rodolfo. January 2016 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: O presente estudo analisou a exatidão de modelos de gesso, obtidos a partir de diferentes técnicas de moldagem, incluindo casquetes individuais, isolados ou unidos, bem como mensurou o desajuste marginal cervical de infraestruturas de zircônia sobre preparos dentais para coroa total. Foi utilizado um modelo mestre (controle), com preparos nos dentes 14, 16, 21 e 25, sobre o qual infraestruturas de zircônia foram confeccionadas por tecnologia CAD/CAM. Para cada técnica de moldagem: simultânea com silicone de condensação (T1a), ou adição (T1b); casquetes individuais isolados (T2); unidos com cilindros de resina acrílica (T3); unidos com cilindros metálicos (T4); foram obtidos 8 moldes totais, por único operador calibrado, com moldeira de estoque. As moldagens com casquetes foram realizadas com poliéter e as transferências com silicone de condensação. Para a análise da adaptação marginal cervical das infraestruturas de zircônia, as mesmas foram passivamente adaptadas sobre os preparos nos modelos de gesso, sendo as mensurações do desajuste marginal cervical realizadas em estereomicroscópio (50x). Para a análise de exatidão dimensional linear oclusal global, os modelos foram escaneados e, a partir de três pontos pré-definidos, realizadas mensurações látero-laterais (LL) e anteroposteriores (AP) bilaterais do arco dental no programa ImageJ. Além disso, mensurações das dimensões áxio-cervicais de cada preparo e da distância entre os preparos do segmento 14-16 foram realizadas com p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study examined the accuracy of gypsum casts obtained from different impression techniques, including individual acrylic copings, and measured the cervical misfit of zirconia frameworks on dental preparations for fixed prosthodontics. A master cast with preparations in the teeth #14, 16, 21 and 25, on which zirconia frameworks were made by CAD/CAM technology, was used as control (baseline measurements). For each impression technique: single-step with condensation silicone (T1a), or vinyl polysiloxane (T1b); individual acrylic copings (T2); acrylic copings bonded with acrylic resin cylinders (T3) or metal cylinders (T4), 8 impressions were obtained by a single calibrated operator using stock trays. For the techniques T2, T3 and T4, polyether was used into the acrylic copings and condensation silicone was used for their pick-up. For the analysis of cervical marginal fit, zirconia frameworks were passively seated on the dental preparations of the gypsum casts, and measurements of cervical misfit calculated in stereo (50x). For the analysis of occlusal linear dimensional accuracy, the casts were scanned and, from three pre-defined points, side-to-side (LL) and bilateral anteroposterior (AP) measurements were performed by means of digitized images in the ImageJ software. Additionally, measurements of axio-cervical dimensions of each dental preparation and the distance between the preparations of the #14-16 fixed prosthodontics' segment were taken with a digital caliper. Statis... (Complete abstract click electronic access below) / Mestre
7

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Bueno Junior, Eliseu Antonio 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
8

Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes? / Can the selection of the technique be superior to the material selected for the splint of transferents?

Mariotto, Guilherme de Aguiar 27 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-03-12T21:59:27Z No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2019-03-12T21:59:27Z (GMT). No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-27 / STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the models / DECLARAÇÃO DO PROBLEMA: A técnica de união entre os transferentes de moldagem para próteses sobre implantes pode resultar em desadaptações nas infraestruturas protéticas. OBJETIVOS: Avaliar a alteração dimensional linear de polimerização de 3 materiais e 2 técnicas de união de transferentes de moldagem para próteses sobre implantes utilizados na técnica da moldeira aberta. MATERIAL E MÉTODOS: Foi confeccionada uma matriz em forma de maxila em nylon, instalados dois implantes osseointegráveis e, sobre esses dois, minipilares cônicos retos. Transferentes de moldagem de moldeira aberta foram acoplados aos minipilares, e uma guia de silicone foi confeccionada padronizando as uniões entre transferentes. As amostras foram divididas em seis grupos (n=20): resinas acrílicas quimicoativadas Pattern Resin (PA) e Durallay (DU), e resina bisacrílica Protemp4 (BI), com as técnicas passo único e secção e união dos segmentos (PAC, DUC, BIC). Os valores de alteração dimensional linear ocorridos entre esses transferentes foram mensurados em projetor de perfil (VB300; Starret) acoplado ao aparelho Quadra Check, com capacidade de mensuração de 0.001 mm, realizado por único operador calibrado. Os dados foram submetidos ao teste de ANOVA fatorial, two-way: Materiais e técnica (p<0,01). RESULTADOS: Foram encontrados resultados estatisticamente significantes em todas as comparações. A resina PA apresentou os menores valores (μm) de alteração dimensional linear, tanto na técnica de passo único, quanto na técnica de secção e união, na seguinte ordem: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). A técnica de passo único obteve piores resultados independente do material. CONCLUSÕES: A técnica de secção e união reduziu a alteração dimensional das amostras em todos os materiais, e a resina Pattern Resin LS apresentou a menor contração, seguida pela Durallay e Protemp4. IMPLICAÇÕES CLÍNICAS: Para a união de transferentes em próteses sobre implantes a escolha da técnica de união parece ser mais importante do que a seleção do material para a obtenção de maior fidelidade dos modelos.
9

Influência de técnicas e materiais de moldagem na precisão de modelos de trabalho obtidos para a confecção de prótese fixa convencional e sobre implante / Influence of techniques and impression materials on the accuracy of working casts obtained for the confection of conventional and implant-supported fixed prosthesis

Vargas, Fernando Fernandes 20 February 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-14T11:46:02Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência de técnicas e materiais de moldagem na precisão de modelos de.pdf: 759210 bytes, checksum: 1bd252ce92c5a18682ec4a9120348f75 (MD5) / Made available in DSpace on 2017-07-14T11:46:02Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência de técnicas e materiais de moldagem na precisão de modelos de.pdf: 759210 bytes, checksum: 1bd252ce92c5a18682ec4a9120348f75 (MD5) Previous issue date: 2017-02-20 / Sem bolsa / De acordo com a literatura, os materiais de moldagem disponíveis no mercado sofrem alteração dimensional após sua presa. Essa distorção pode afetar a precisão e, consequentemente, a adaptação final de próteses parciais fixas convencionais e sobre implantes. O objetivo do presente estudo foi de investigar e comparar, através do uso de escaneamento tridimensional e software de comparação de superfícies, as alterações tridimensionais decorrentes do procedimento de moldagem e obtenção de modelos de trabalho utilizando diferentes materiais e técnicas de moldagem comumente usadas na prática odontológica. Um modelo mestre para dentes contendo um incisivo central e um canino superiores preparados para receber prótese fixa de três elementos livre de metal e outro modelo contendo dois análogos de implantes com conexão hexagonal externa foram obtidos. Os grupos (n=5) foram divididos de acordo com a técnica (dupla mistura, moldagem única e com casquete para dentes e direta e indireta para implantes) e material de moldagem (silicone de adição, silicone de condensação e poliéter). A avaliação e comparação das superfícies com o modelo mestre foram realizadas através de escaneamento 3-D (S600 ARTI, Zirkonzahn) e software de análises específico (Geomagic Qualify v.13, Geomagic Inc). Os resultados obtidos foram submetidos à análise estatística que demonstrou não haver diferença significante entre as técnicas de moldagem tanto para dentes quanto para implantes; porém, no caso dos materiais de moldagem, os modelos de trabalho obtidos à partir de moldagens com silicone de condensação apresentaram menor distorção que os modelos obtidos com os demais materiais. Entretanto, os valores de variação foram bastante pequenos e talvez não apresentem significância clínica. Baseado no que foi exposto, pode-se concluir que o cirurgião-dentista deve escolher a técnica e o material que considera mais apto a utilizar em moldagem para próteses fixas, tanto sobre dentes quanto sobre implantes. / According to the literature, all the available impression materials on the market deform after its polymerization. This distortion can affect the precision and, consequently, the marginal fit of fixed partial dentures on teeth or implants. The aim of this study was to investigate and compare, through the use of three-dimensional scanning and surface comparison software, the dimensional changes of working cast originated from different impression techniques and materials commonly used on the dental practice.. Master casts containing a maxillary central incisor and a canine prepared to receive a three-unit metal-free fixed partial denture and two external hex implant analogues were made. Groups (n=5) were divided according to the technique (dual mixture, single impression and custom tray for teeth; and direct or indirect for implants), and impression material (polyvinyl siloxane, polydimethylsiloxane and polyether). Evaluation and comparison of the surfaces between master cast and specimens were performed with a fully automated optical structured-light scanner (S600 ARTI, Zirkonzahn) and Geomagic Qualify v.13 (Geomagic Inc.) software inspection tool. The obtained results were submitted to statistical analysis, which showed that there was no significant difference between the impression techniques for both teeth and implants groups; however, in regard of impression materials, working casts obtained by polydimethylsiloxane impressions showed lower volumetric distortion than casts obtained with the other impression materials. However, the distortion values were very small and may not be clinically significant. Based on the above, it can be concluded that the dentist could choose the impression technique and material that he considers most suitable for fixed prostheses teeth or implant-borne prostheses .
10

Influência de técnicas de moldagem e de dois vazamentos na precisão dimensional de modelos de gesso e adaptação marginal de infraestruturas CAD/CAM em Y-TZP /

Messias, Aion Mangino. January 2015 (has links)
Orientador: José Maurício dos Santos Nunes / Banca: Francisco de Assis Mollo Júnior / Banca: Mauro Antonio de Arruda Nóbilo / Resumo: Este estudo objetivou analisar a exatidão de modelos de gesso, a partir de diferentes técnicas de moldagem e segundos vazamentos de gesso, bem como mensurar o desajuste marginal de infraestruturas de zircônia sobre preparos dentais reproduzidos nesses modelos. Um modelo mestre, com preparos para coroa total nos dentes 14, 16, 21 e 25, foi obtido e infraestruturas em zircônia CAD/CAM foram confeccionadas. Moldes totais com moldeira de estoque e silicone de adição foram obtidos a partir de três técnicas de moldagem (n=15): T1) mistura simultânea; T2) reembasamento - alívio com filme de PVC e T3) reembasamento - alívio com movimentação da moldeira. Foram aguardados 120 min para o 1º. vazamento de gesso (Tipo IV). O 2º. vazamento foi realizado 120 min após a remoção dos primeiros modelos. Para a mensuração da adaptação marginal das infraestruturas utilizou-se estereomicroscópio LEICA (50x). Para a análise da precisão dimensional linear, os modelos foram fotografados e, a partir de pontos pré-definidos, mensurações oclusais lineares latero-laterais (LL) e anteroposteriores, direita (APD) e esquerda (APE), foram realizadas (ImageJ). Mensurações das dimensões mésio-distais (MD) e vestíbulo-linguais (VL) dos preparos e da distância interpreparos do segmento 14-16 foram realizadas. Após verificação da distribuição e da homocedasticidade dos dados, métodos estatísticos (α=0,05) foram empregados para avaliar a influência das variáveis independentes. De maneira geral, os modelos geraram maiores desajustes marginais em relação ao modelo mestre, independente do vazamento (1º ou 2º). Após 1º. vazamento, a técnica simultânea apresentou tendência a apresentar valores de desajuste menores do que as demais técnicas. Com exceção da dimensão MD do dente 21, a técnica simultânea produziu dimensões MD e VL similares ao modelo mestre. Não houve...(Resumo completo clicar acesso eletrônico abaixo) / Abstract: This study conducted laboratory analysis of dental casts' accuracy obtained from different impression techniques and two castings, as well as measure the cervical marginal fit of zirconia infrastructures on dental preparations played in these models. Master model was used, with crown preparations in the teeth 14, 16, 21 and 25, on which zirconia infrastructures were made by CAD/CAM technology. For each impression technique full molds (n=15) were obtained by a single calibration operator with stock tray and polyvinylsiloxane: (T1) simultaneous mixture; (T2) reline - relief with PVC film and (T3) reline - relief with small movement of the tray. After mold removal, it was expected 120 min to realize the first pouring (type IV gypsum). The second pouring was made after 120 min from the removal of the first cast. To measure the marginal adaptation of infrastructure was used stereomicroscope LEICA (50x). For the analysis of linear dimensional accuracy, the models were photographed and, from pre-defined points, linear lateral-side occlusal measurements (LL) and anteroposterior, right (RPA) and left (EPA), were performed (ImageJ). Measurements of mesiodistal dimensions (MD) and bucco-lingual (VL) of the preparations and interpreparos distance segment 14-16 were performed. After verification of distribution and homocedasticity data, statistical methods (α = 0.05) were used to assess the influence of the independent variables. In general, larger models generated fringe displacement in relation to the master model, irrespective of the time of pouring (1º ou 2º). After 1st. pouring, the simultaneous technique tended to have lower misfit values than other techniques. Aside from tooth MD dimension 21 simultaneous technique produced dimensions MD and BL similar to the master model. No differences in inter-preparation linear dimensions and the occlusal line...(Complete abstract electronic access below) / Mestre

Page generated in 0.0607 seconds