• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 5
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 25
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Towards an Understanding of the Gas Diffusion Layer in Polymer Electrolyte Membrane Fuel Cells

Morgan, Jason 12 December 2016 (has links)
The gas diffusion layer (GDL) is one of the key components in a polymer electrolyte membrane (PEM) fuel cell. It performs several functions including the transport of reactant gases and product water to and from the catalyst layer, conduction of both electrons and heat produced in the catalyst layer, as well as mechanical support for the membrane. The overarching goal of this work is to thoroughly examine the GDL structure and properties for use in PEM fuel cells, and more specifically, to determine how to characterize the GDL experimentally ex-situ, to understand its performance in-situ, and to relate theory to performance through controlled experimentation. Thus, the impact of readily measured effective water vapor diffusivity on the performance of the GDL is investigated and shown to correlate to the wet limiting current density, as a surrogate of the oxygen diffusivity to which it is more directly related. The influence of microporous layer (MPL) design and construction on the fuel cell performance is studied and recommendations are made for optimal MPL designs for different operating conditions. A method for modifying the PTFE (Teflon) distribution within the GDL is proposed and the impact of distribution of PTFE in the GDL on fuel cell performance is studied. A method for characterizing the surface roughness of the GDL is developed and the impact of surface roughness on various ex-situ GDL properties is investigated. Finally, a detailed analysis of the physical structure and permeability of the GDL is provided and a theoretical model is proposed to predict both dry and wet gas flow within a GDL based on mercury intrusion porosimetry and porometry data. It is hoped that this work will contribute to an improved understanding of the functioning and structure of the GDL and hence advance PEM fuel cell technology.
22

Optimalizace tras při rozvozu zásilek / Route optimization for the parcels distribution

Ptáčková, Michaela January 2014 (has links)
This thesis deals with optimization problems of the parcels distribution. This issue can be solved on the ground of traveling salesman problem whose mathematical and economic model, including their modifications, are presented in the theoretical part of the thesis. We can solve these problems by using exact methods, heuristic and metaheuristic algorithms. In the theoretical part are described traveling salesman problem, traveling salesman problem with time windows, traveling salesman problem with multiple time windows and dynamic traveling salesman problem including possible ways of solution. In the practical part we can find application of problems on the real example, when we are finding the shortest possible route for the PPL's employee under different assumptions. The solution is obtained by using solver Gurobi within the modelling system MPL for Windows. In conclusion of the thesis the results are summarized and models are compared with each other.
23

Congenital amegakaryocytic thrombocytopenia iPS cells exhibit defective MPL-mediated signaling / 先天性無巨核球性血小板減少症患者由来のiPS細胞はMPLを介した細胞内シグナルが欠落している

Hirata, Shinji 26 March 2018 (has links)
京都大学 / 0048 / 新制・論文博士 / 博士(医学) / 乙第13159号 / 論医博第2146号 / 新制||医||1029(附属図書館) / (主査)教授 河本 宏, 教授 前川 平, 教授 髙折 晃史 / 学位規則第4条第2項該当 / Doctor of Medical Science / Kyoto University / DFAM
24

PLAGL2 Cooperates in Leukemia Development by Upregulating MPL Expression: A Dissertation

Landrette, Sean F. 22 June 2006 (has links)
Chromosomal alterations involving the RUNXI or CBFB genes are specifically and recurrently associated with human acute myeloid leukemia (AML). One such chromosomal alteration, a pericentric inversion of chromosome 16, is present in the majority of cases of the AML subtype M4Eo. This inversion joins CBFB with the smooth muscle myosin gene MYH11 creating the fusion CBFB-MYH11. Knock-in studies in the mouse have demonstrated that expression of the protein product of the Cbfb-MYH11fusion, Cbfβ-SMMHC, predisposes mice to AML and that chemical mutagenesis both accelerates and increases the penetrance of the disease (Castilla et al., 1999). However, the mechanism of transformation and the associated collaborating genetic events remain to be resolved. As detailed in Chapter 2, we used retroviral insertional mutagenesis (RIM) to identify mutations in Cbfb-MYH11 chimeric mice that contribute to AML. The genetic screen identified 54 independent candidate cooperating genes including 6 common insertion sites: Plag1, Plagl2, Runx2, H2T23, Pstpip2, and Dok1. Focusing on the 2 members of the Plag family of transcription factors, Chapter 3 presents experiments demonstrating that Plag1 and Plagl2 independently cooperate with Cbfβ-SMMHC in vivo to efficiently trigger leukemia with short latency in the mouse. In addition, Plag1 and PLAGL2 increased proliferation and in vitro cell renewal in Cbfβ-SMMHC hematopoietic progenitors. Furthemore, PLAG1 and PLAGL2 expression was increased in 20% of human AML samples suggesting that PLAG1 and PLAGL2 may also contribute to human AML. Interestingly, PLAGL2was preferentially increased in samples with chromosome 16 inversion, t(8;21), and t(15;17). To define the mechanism by which PLAGL2 contributes to leukemogenesis, Chapter 4 presents studies assessing the role of the Mp1 signaling cascade as a Plagl2 downstream pathway in leukemia development. Using microarray analysis we discovered that PLAGL2 induces the expression of Mp1 transcript in primary bone marrow cells that express Cbfβ-SMMHC and that this induction is maintained in leukemogenesis. We have also performed luciferase assays to confirm that the Mp1 proximal promoter can be directly bound and activated by PLAGL2. Furthermore, we demonstrate increased Mp1 expression leads to hypersensitivity to the Mp1 ligand thrombopoietin (TPO) in PLAGL2/Cbfβ-SMMHC leukemic cells. To test the functional relevance in leukemia formation, we performed a bone-marrow transplantation assay and demonstrate that overexpression of Mp1 is indeed sufficient to cooperate with Cbfβ-SMMHC in leukemia induction. This data reveals that PLAGL2 cooperates with Cbfβ-SMMHC at least in part by inducing the expression of the cytokine receptor Mp1. Thus, we have identified the Mp1 signal transduction pathway as a novel target for therapeutic intervention in AML.
25

Interfacial measurements of colloidal and bio-colloidal systems in real-time

Coffey, Paul David January 2011 (has links)
As advances in thin films are made there is a parallel requirement to develop equipment capable of measuring their properties accurately and consistently. In addition there is a need to understand the parameters that are measured. Typical DPI measurements allow both the refractive index (related to density) and the thickness of the adsorbed layer to be calculated with relatively few assumptions, to a very high precision in real time. This thesis presents the research undertaken to develop multiple path length dual polarisation interferometry (MPL-DPI) and absorption enhanced dual polarisation interferometry (AE-DPI). In addition research is presented that can be used to improve the interpretation of the measured parameters for inhomogeneous films and uniaxial films. The new Interferometric technique MPL-DPI allows the thickness and refractive index of in situ and ex-situ coated ultra-thin films to be measured. The procedures and the mathematics required to calculate the properties of films have been described and the technique verified. The technique was demonstrated using films of PMMA, where good agreement was found with complementary techniques. Furthermore, some key features of MPL-DPI were demonstrated using the measurements of interfacially grafted acrylic acid. The absorption enhanced DPI uses the attenuation of the light within the waveguide, due to the light absorbing properties of a film on its surface. As the composition of a film changed, it was shown that the refractive index and extinction coefficients could be used to separate the mass of the components of the film that absorbed light, from the components of the film that did not. With the use of a semi-uniaxial model, the extra data from the attenuation in two polarisations was used to fit the extraordinary and ordinary extinction coefficients. The extraordinary and ordinary extinction coefficients were used to demonstrate that molecular orientation could be implied. The influence that an inhomogeneous film has on the measured thickness, refractive index and extinction coefficient fitted by homogeneous models were investigated. Formulas are presented to explain the thickness, refractive index and extinction coefficient of the measured film. A formula for the total mass per unit area that uses the refractive index was created to account for films that contain molecules of different refractive index increments (dn/dc's). To separate the mass of the individual molecular species from the total mass per unit area, formulas that use the extinction coefficient were derived so molecules that absorb light could be separated from those that do not. The mass calculated from the refractive index and the mass calculated from the extinction coefficient were also examined for uniaxial films. For uniaxial films both measures of the adsorbed mass were found to be relatively accurate and benefited from a partial cancellation of errors. The accuracy of the measurements made by dual polarisation interferometry technology is systematically examined throughout this thesis. Improvements in the calibration routines are suggested and a procedure for the identification and reduction of errors in the phase and contrast is demonstrated.

Page generated in 0.0467 seconds