• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 13
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Sensitivity and Specificity of Multifocal Electroretinography in Detecting Chloroquine and Hydroxychloroquine Retinal Toxicity

Ahmadi Pirshahid, Sina January 2015 (has links)
To calculate the sensitivity and specificity of multifocal electroretinography (mfERG) in detection of chloroquine and hydroxychloroquine retinal toxicity, 120 eyes of 63 patients were evaluated using the currently recommended diagnostic tests. The results were compared to those of 54 eyes of 28 control subjects. The sensitivity and specificity of mfERG relative to the combination of automated visual fields and optical coherence tomography (the reference test) were calculated to be 87% and 86.5% respectively. However, analysis of the “false positive” cases proved that mfERG was more sensitive than the reference test and the actual sensitivity and specificity values were higher than the results of this study. Reduction of mfERG amplitude was a strong and reliable sign of early retinal toxicity and was correlated with the cumulative dose of hydroxychloroquine. This correlation was not observed with the reference test quantitative values.
12

Peripheral Refractive Error in Multifocal Contact Lenses

Smith, Molly J. 01 September 2016 (has links)
No description available.
13

Tradução, adaptação transcultural e validação da escala global de avaliação das incapacidades na neuropatia motora multifocal / Translation, cultural adaptation and validation of the Rasch-built overall disability scale for multifocal motor neuropathy

Moreira, Paulo Sérgio Rosa 15 March 2019 (has links)
A neuropatia motora multifocal (NMM) é uma doença rara, que compromete as fibras nervosas motoras e que pode levar a incapacidades de gravidade variável, provavelmente na dependência do seu diagnóstico e tratamento precoces. O uso de imunoglobulina humana por via endovenosa em altas doses é considerado o tratamento mais eficaz para NMM. A objetivação das incapacidades funcionais que a NMM provoca e da sua reversão parcial ou completa em decorrência do tratamento ou de sua evolução não tem sido uniforme. Tais dificuldades se devem ao fato de que os instrumentos utilizados para a mensuração das incapacidades têm sido variados e não uniformes. A escala global de avaliação das incapacidades na neuropatia motora multifocal construída pelo método Rasch (GIR - MNN) ou Multifocal Motor Neuropathy - Rasch-built Overal Disability Scale (MMN-RODS©) foi desenvolvida especificamente para a avaliação das incapacidades funcionais dos pacientes com NMM. Em recente estudo, multicêntrico, foi verificado que a MMN-RODS©, originalmente desenvolvida em inglês, preenche as expectativas do modelo de Rasch. Para aplicação no Brasil, o presente trabalho realizou a tradução, a adaptação transcultural, conforme metodologia descrita na literatura, e a aplicação da escala em pacientes com Neuropatia Motora Multifocal / Multifocal Motor Neuropathy (MMN) is a rare disease that involves the motor nerve fibers. A better prognosis for MMN is probably linked to early diagnoses and treatment. Even so, MMN can lead to severe incapacities. The use of intravenous high doses of human immunoglobulin (IgIV) is considered efficacious to treat MMN. The objectification of the incapacities provoked by MNN, their evolution, and partial or complete deficits reversion due to the treatment has not been standardized. This lack of uniformity is due to the variety of tools used for the measurement of the deficits in MMN. The multifocal motor neuropathy - Raschbuilt overall disability scale (MMN-RODS©) was developed specifically for evaluation of the functional incapacities in MNN patients. In a recent multicentric study, it was verified that MMN-RODS© fulfill the expectations of the Rasch method. The present work realized the translation, transcultural adaptation and validation of the scale to the Brazilian Portuguese context aiming to use this tool to evaluate MMN patients living in Brazil
14

Distribuição genotípica do poliomavirus humano JC em pacientes com aids, com e sem leucoencefalopatia multifocal progressiva, em São Paulo, Brasil / Genotype distribution of human polyomavirus JC in AIDS patients with and without progressive multifocal leukoencephalopathy, in Sao Paulo, Brazil

Fink, Maria Cristina Domingues da Silva 12 March 2010 (has links)
A relação entre os diferentes genótipos do VJC e a patogênese da LEMP permanece ainda uma questão controversa. O presente estudo visou a caracterização genotipica do vírus JC (VJC) e sua associação com a leucoencefalopatia multifocal progressiva (LEMP) em pacientes com aids em São Paulo, no período de 2000 a 2008. Foram avaliadas 51 amostras de líquor de pacientes com LEMP e 47 amostras de pacientes com aids sem LEMP positivas para os genes T e VP1 pela reação em cadeia por polimerase (PCR). Foram identificados, através do sequenciamento genômico os genótipos 1, 2, 3, 4 e 6, sendo que os mais prevalentes foram os genótipos 2 (33%), 1 (27%), seguidos pelo genótipo 3 (23%). O genótipo 1 e mostrou associação positiva com a LEMP (p<0,05), enquanto que o genótipo 3 mostrou associação inversa à LEMP. Durante a internação em que foi diagnosticada LEMP observamos evolução para óbito em 27 (59%) pacientes e alta em 19 (41%). Não houve associação entre os genótipos do VJC ou carga viral liquórica e a evolução para óbito, mas houve associação significante entre o número de linfócitos TCD4+ e o óbito. No presente estudo, uma mutação no sítio 91 do gene VP1 com substituição da leucina para isoleucina ou valina, não descrita anteriormente, foi encontrada exclusivamente em pacientes com LEMP. Substituições nos sítios 123, 128 e 134 foram observadas mais frequentemente nos casos de LEMP. Não foram encontradas diferenças filogenéticas entre as sequências obtidas dos casos e dos controles. A PCR em tempo real padronizada mostrou sensibilidade e especificidade diagnósticas de 89% e 100%, respectivamente. / The relationship between the different genotypes of VJC and the pathogenesis of progressive multifocal leukoencephalopathy remains a controversial issue. This study aimed to genotypic characterization of JC virus (JCV) and its association with progressive multifocal leukoencephalopathy (PML) in AIDS patients in Sao Paulo, from 2000 to 2008. We analyzed 51 CSF samples from patients with PML and 47 samples of AIDS patients without PML positives for the T and VP1 genes by polymerase chain reaction (PCR). Were identified by genomic sequencing genotypes 1, 2, 3, 4 and 6, and were the most prevalent genotypes 2 (33%), 1 (27%), followed by genotype 3 (23%). Genotype 1 showed a positive association with PML (p <0.05), while genotype 3 was inversely associated with PML. Overall in-hospital mortality was 59% (27 patients). No association between the genotypes of VJC or CSF viral load and progression to death, but there was a significant association between number of CD4 + and death. In this study, a mutation in site 91 of VP1 gene with substitution of leucine for isoleucine or valine, not described previously, was found exclusively in patients with PML. Substitutions at sites 123, 128 and 134 were observed more frequently in cases of PML. No differences were found between phylogenetic sequences obtained from cases and controls. The real-time PCR showed standardized diagnostic sensitivity and specificity of 89% and 100%, respectively.
15

Avaliação da acuidade visual e qualidade de vida pós-operatórias de pacientes submetidos ao implante bilateral da lente intraocular multifocal refrativa-difrativa EyeDiff / Evaluation of patients' visual acuity and quality of life after bilateral implantation of multifocal intraocular lens EyeDiff

Queiroz, Marjorie Fornazier do Nascimento de 22 February 2018 (has links)
Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-13T13:33:12Z No. of bitstreams: 1 Dissertação corrigida.docx: 1063474 bytes, checksum: a294630584043d85364c1994f91ac26e (MD5) / Rejected by Luciana Pizzani null (luciana@btu.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: problema 1: o arquivo submetido deve, obrigatoriamente, estar em formato PDF. Seu arquivo está em word. Assim que tiver efetuado essa correção submeta o arquivo, em PDF, novamente. Agradecemos a compreensão. on 2018-04-13T17:52:53Z (GMT) / Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-13T20:18:43Z No. of bitstreams: 2 Dissertação corrigida.pdf: 3450020 bytes, checksum: c8bca522995d10e2ee7b7d957bd1b67c (MD5) Ficha catalográfica.pdf: 196557 bytes, checksum: 0a1da60dbc50589c50298c259a920c52 (MD5) / Rejected by ROSANGELA APARECIDA LOBO null (rosangelalobo@btu.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: problema 1: arquivos separados (dissertação e ficha catalográfica) O arquivo deve ser único e a ficha catalográfica deve ser inserida no arquivo PDF logo após a folha de rosto do seu trabalho. Assim que tiver efetuado a correção ou correções submeta o arquivo em PDF novamente. Agradecemos a compreensão. on 2018-04-17T13:29:17Z (GMT) / Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-17T19:51:20Z No. of bitstreams: 1 Dissertação corrigida c ficha cat (1).pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2018-04-19T12:13:23Z (GMT) No. of bitstreams: 1 queiroz_mfn_me_bot.pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) / Made available in DSpace on 2018-04-19T12:13:23Z (GMT). No. of bitstreams: 1 queiroz_mfn_me_bot.pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) Previous issue date: 2018-02-22 / RESUMO Objetivo: o presente estudo teve como objetivo geral avaliar os resultados visuais, satisfação e qualidade de vida de pacientes submetidos a implante bilateral de LIO multifocal e como objetivos específicos, a avaliação da acuidade visual (AV) para longe, perto e intermediária, do teste de sensibilidade ao contraste e da qualidade de vida destes pacientes por meio de questionário (NEI-VFQ 25). Métodos: foi realizado um estudo prospectivo e intervencionista que incluiu 20 pacientes portadores de catarata senil bilateral, em acompanhamento no setor de Catarata dos Hospital das Clínicas da Faculdade de Medicina de Botucatu. Os critérios de exclusão foram astigmatismo corneano maior que 1,5 D, olho único, história de cirurgia intraocular prévia ou doença ocular que cause redução da AV, falta de motivação do paciente em realizar o procedimento cirúrgico bilateralmente, complicações intra-operatórias e recusa em assinar o TCLE. Os pacientes foram submetidos a implante bilateral da LIO multifocal EyeDiff®, da Eyeol UK®, e foram avaliados no 1o, 3o e 6o mês de pós-operatório com medidas da AV (longe, intermediária e perto, monocular e binocular, sob condições fotópicas e mesópicas), qualidade de visão (avaliação da sensibilidade ao contraste) e qualidade de vida através de um questionário de satisfação. Resultados: todos os olhos apresentaram AV monocular e binocular de 0,3 LogMAR ou melhor para longe e J3 ou melhor para perto com a melhor correção para longe, sob condições fotópicas. A curva de defocus mostrou adição de +2,50 no plano dos óculos. A sensibilidade ao contrate esteve no nível inferior da normalidade para frequências espaciais baixas e altas e abaixo do nível mínimo em frequências intermediárias. A media geral das avaliações no questionário de qualidade de vida foi de 91. Conclusão: conclui-se que o implante da LIO multifocal proporcionou bons resultados no que se refere à AV pós-operatória, além de maior independência dos óculos e melhora da qualidade de vida. / ABSTRACT Purpose: the present study had as main goal to evaluate visual outcomes, satisfaction and quality of life of patients submitted to bilateral implant of multifocal intraocular lens (IOL), and as specific aims, evaluation of distance, intermediate and near visual acuity (VA), contrast sensitivity and quality of life of these patients using a questionnaire (NEI-VFQ 25). Methods: this was a prospective and interventionist study, that included 20 patients with bilateral senil cataract, followed at Botucatu Medicine School. Exclusion criteria were corneal astigmatism superior to 1,50 D, single eye, previous intraocular surgery or ocular disease, intra-operatory complications and refuse in signing the consent form. Patients were submitted to bilateral implant of multifocal IOL EyeDiff® Eyeol UK® and were evaluated at 1o, 3o and 6o month, postoperatively, with VA testing (for distance, intermediate and near, monocular and binocular, under fotopic and mesopic conditions), eyesight quality (contrast sensitivity evaluation) and quality of life through a satisfaction questionnaire. Results: all eyes presented monocular and binocular CDVA of 0,3 LogMar or better and DCNVA of J3 or better, under photopic and mesopic conditions. Defocus curve showed best performance at +2,50 D. Contrast sensitivity were in the minimum level of normality for low and high special frequencies and under normal limits for intermediate special frequency. The quality of life questionnaire had average score of 91. Conclusion: in conclusion, multifocal IOL implant provided good results for post-operative VA, in addition to greater spectacle independence and quality of life improvement.
16

Avaliação da acuidade visual e qualidade de vida pós-operatórias de pacientes submetidos ao implante bilateral da lente intraocular multifocal refrativa-difrativa EyeDiff

Queiroz, Marjorie Fornazier do Nascimento de January 2018 (has links)
Orientador: Antonio Carlos Lottelli Rodrigues / Resumo: RESUMO Objetivo: o presente estudo teve como objetivo geral avaliar os resultados visuais, satisfação e qualidade de vida de pacientes submetidos a implante bilateral de LIO multifocal e como objetivos específicos, a avaliação da acuidade visual (AV) para longe, perto e intermediária, do teste de sensibilidade ao contraste e da qualidade de vida destes pacientes por meio de questionário (NEI-VFQ 25). Métodos: foi realizado um estudo prospectivo e intervencionista que incluiu 20 pacientes portadores de catarata senil bilateral, em acompanhamento no setor de Catarata dos Hospital das Clínicas da Faculdade de Medicina de Botucatu. Os critérios de exclusão foram astigmatismo corneano maior que 1,5 D, olho único, história de cirurgia intraocular prévia ou doença ocular que cause redução da AV, falta de motivação do paciente em realizar o procedimento cirúrgico bilateralmente, complicações intra-operatórias e recusa em assinar o TCLE. Os pacientes foram submetidos a implante bilateral da LIO multifocal EyeDiff®, da Eyeol UK®, e foram avaliados no 1o, 3o e 6o mês de pós-operatório com medidas da AV (longe, intermediária e perto, monocular e binocular, sob condições fotópicas e mesópicas), qualidade de visão (avaliação da sensibilidade ao contraste) e qualidade de vida através de um questionário de satisfação. Resultados: todos os olhos apresentaram AV monocular e binocular de 0,3 LogMAR ou melhor para longe e J3 ou melhor para perto com a melhor correção para longe, sob condições fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ABSTRACT Purpose: the present study had as main goal to evaluate visual outcomes, satisfaction and quality of life of patients submitted to bilateral implant of multifocal intraocular lens (IOL), and as specific aims, evaluation of distance, intermediate and near visual acuity (VA), contrast sensitivity and quality of life of these patients using a questionnaire (NEI-VFQ 25). Methods: this was a prospective and interventionist study, that included 20 patients with bilateral senil cataract, followed at Botucatu Medicine School. Exclusion criteria were corneal astigmatism superior to 1,50 D, single eye, previous intraocular surgery or ocular disease, intra-operatory complications and refuse in signing the consent form. Patients were submitted to bilateral implant of multifocal IOL EyeDiff® Eyeol UK® and were evaluated at 1o, 3o and 6o month, postoperatively, with VA testing (for distance, intermediate and near, monocular and binocular, under fotopic and mesopic conditions), eyesight quality (contrast sensitivity evaluation) and quality of life through a satisfaction questionnaire. Results: all eyes presented monocular and binocular CDVA of 0,3 LogMar or better and DCNVA of J3 or better, under photopic and mesopic conditions. Defocus curve showed best performance at +2,50 D. Contrast sensitivity were in the minimum level of normality for low and high special frequencies and under normal limits for intermediate special frequency. The quality of life questionnaire had average scor... (Complete abstract click electronic access below) / Mestre
17

Distribuição genotípica do poliomavirus humano JC em pacientes com aids, com e sem leucoencefalopatia multifocal progressiva, em São Paulo, Brasil / Genotype distribution of human polyomavirus JC in AIDS patients with and without progressive multifocal leukoencephalopathy, in Sao Paulo, Brazil

Maria Cristina Domingues da Silva Fink 12 March 2010 (has links)
A relação entre os diferentes genótipos do VJC e a patogênese da LEMP permanece ainda uma questão controversa. O presente estudo visou a caracterização genotipica do vírus JC (VJC) e sua associação com a leucoencefalopatia multifocal progressiva (LEMP) em pacientes com aids em São Paulo, no período de 2000 a 2008. Foram avaliadas 51 amostras de líquor de pacientes com LEMP e 47 amostras de pacientes com aids sem LEMP positivas para os genes T e VP1 pela reação em cadeia por polimerase (PCR). Foram identificados, através do sequenciamento genômico os genótipos 1, 2, 3, 4 e 6, sendo que os mais prevalentes foram os genótipos 2 (33%), 1 (27%), seguidos pelo genótipo 3 (23%). O genótipo 1 e mostrou associação positiva com a LEMP (p<0,05), enquanto que o genótipo 3 mostrou associação inversa à LEMP. Durante a internação em que foi diagnosticada LEMP observamos evolução para óbito em 27 (59%) pacientes e alta em 19 (41%). Não houve associação entre os genótipos do VJC ou carga viral liquórica e a evolução para óbito, mas houve associação significante entre o número de linfócitos TCD4+ e o óbito. No presente estudo, uma mutação no sítio 91 do gene VP1 com substituição da leucina para isoleucina ou valina, não descrita anteriormente, foi encontrada exclusivamente em pacientes com LEMP. Substituições nos sítios 123, 128 e 134 foram observadas mais frequentemente nos casos de LEMP. Não foram encontradas diferenças filogenéticas entre as sequências obtidas dos casos e dos controles. A PCR em tempo real padronizada mostrou sensibilidade e especificidade diagnósticas de 89% e 100%, respectivamente. / The relationship between the different genotypes of VJC and the pathogenesis of progressive multifocal leukoencephalopathy remains a controversial issue. This study aimed to genotypic characterization of JC virus (JCV) and its association with progressive multifocal leukoencephalopathy (PML) in AIDS patients in Sao Paulo, from 2000 to 2008. We analyzed 51 CSF samples from patients with PML and 47 samples of AIDS patients without PML positives for the T and VP1 genes by polymerase chain reaction (PCR). Were identified by genomic sequencing genotypes 1, 2, 3, 4 and 6, and were the most prevalent genotypes 2 (33%), 1 (27%), followed by genotype 3 (23%). Genotype 1 showed a positive association with PML (p <0.05), while genotype 3 was inversely associated with PML. Overall in-hospital mortality was 59% (27 patients). No association between the genotypes of VJC or CSF viral load and progression to death, but there was a significant association between number of CD4 + and death. In this study, a mutation in site 91 of VP1 gene with substitution of leucine for isoleucine or valine, not described previously, was found exclusively in patients with PML. Substitutions at sites 123, 128 and 134 were observed more frequently in cases of PML. No differences were found between phylogenetic sequences obtained from cases and controls. The real-time PCR showed standardized diagnostic sensitivity and specificity of 89% and 100%, respectively.
18

Caracterización de los factores clave para la adaptación de lentes de contacto hidrofílicas multifocales

Pérez-Prados, Roque 03 July 2017 (has links)
La motivación principal de realizar nuestra tesis fue comprobar cómo las variables objetivas que se tenían en cuenta en una adaptación de lentes de contacto blandas multifocales (LCBMF) eran a todas luces insuficientes. Por lo tanto nuestra hipótesis se basa en que el éxito en la adaptación a las LCBMF depende de una serie de objetivos y subjetivos del paciente, junto con la combinación de diseños empleada en cada caso. Para verificar dicha hipótesis se analizaron las diferencias de comportamiento, en el impacto en la calidad de vida y la satisfacción de las distintas combinaciones de diseños, y se identificó cómo variaba el éxito en la adaptación en función de las dominancias oculares y motora, combinadas con la lateralidad del individuo.
19

On the Prognosis of Multifocal Glioblastoma: An Evaluation Incorporating Volumetric MRI

Kasper, Johannes, Hilbert, Nicole, Wende, Tim, Fehrenbach, Michael Karl, Wilhelmy, Florian, Jähne, Katja, Frydrychowicz, Clara, Hamerla, Gordian, Meixensberger, Jürgen, Arlt, Felix 19 January 2024 (has links)
Primary glioblastoma (GBM), IDH-wildtype, especially with multifocal appearance/growth (mGBM), is associated with very poor prognosis. Several clinical parameters have been identified to provide prognostic value in both unifocal GBM (uGBM) and mGBM, but information about the influence of radiological parameters on survival for mGBM cohorts is scarce. This study evaluated the prognostic value of several volumetric parameters derived from magnetic resonance imaging (MRI). Data from the Department of Neurosurgery, Leipzig University Hospital, were retrospectively analyzed. Patients treated between 2014 and 2019, aged older than 18 years and with adequate peri-operative MRI were included. Volumetric assessment was performed manually. One hundred and eighty-three patients were included. Survival of patients with mGBM was significantly shorter (p < 0.0001). Univariate analysis revealed extent of resection, adjuvant therapy regimen, residual tumor volume, tumor necrosis volume and ratio of tumor necrosis to initial volume as statistically significant for overall survival. In multivariate Cox regression, however, only EOR (for uGBM and the entire cohort) and adjuvant therapy were independently significant for survival. Decreased ratio of tumor necrosis to initial tumor volume and extent of resection were associated with prolonged survival in mGBM but failed to achieve statistical significance in multivariate analysis.
20

Objective and Subjective Visual Performance of Soft Multifocal Contact Lenses of Various Add Powers and Center Optic Zone Sizes

Boroff, Jacob Andrew 15 August 2018 (has links)
No description available.

Page generated in 0.0556 seconds