• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 64
  • 16
  • 13
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 218
  • 54
  • 34
  • 33
  • 33
  • 31
  • 29
  • 29
  • 29
  • 24
  • 20
  • 20
  • 19
  • 17
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Coletores alternativos para a determinação da largura de trabalho de distribuidores de fertilizantes sólidos à lanço / Altenative collectors for the determination of the width of work of distributors of solid fertilizers throw her

Primo, Marcelo Alan 06 July 2007 (has links)
Made available in DSpace on 2017-05-12T14:47:21Z (GMT). No. of bitstreams: 1 Marcelo Alan Primo.pdf: 3445063 bytes, checksum: 29c3b04fea727923f8cfb2b19dba08d7 (MD5) Previous issue date: 2007-07-06 / The uniformity of the application in the soil of fertilizers is an important factor in the efficiency of use of the fertilizers and his effect stop plants. The distributors of fertilizers to I throw demand her some basic tunings in what concerns to the flow and work width. The rehearsals of work width and distribution uniformity are of difficult execution for the farmer for they demand equipments, resources and complex methods. Therefore, this work had as objective evaluates alternative collectors to turn more accessible the tuning and evaluation of distributors of fertilizers solid her throw. The work was accomplished in the Agrarian Foundation of Agricultural Research - FAPA, located in the district of Among Rivers, municipal district of Guarapuava - Paraná. Four different groups of collectors were used: i) Collectors built according to the norm ISO 5690/1; ii) Collectors of polyethylene (plastic trays) with soubrette to avoid the material rebound; iii) Collectors formed by boxes of milk long life; iv) Collectors formed by vases of polyethylene (Number 3,5). To the evaluation of the strip of traverse distribution, the collectors were distributed side by side parallel amongst themselves, forming a traverse line to the displacement of the tractor and distributor. A tractor was used Ford, model 7630, in which distributors were coupled: Jan, model Lancer Master 1200; Incomagri, model Sembra 1300-P AH; and Nogueira, model Rota Flow. The alternative collectors presented a larger retention than the established collectors. This relative difference among the collections was larger in the extremities of the distribution profile. The width executes of work obtained for the coefficients of variation of 12,5, 15, 17,5 and 20% varied among the collectors in the different courses. The collector that more it resembled each other the norm were the vases of polyethylene. It was observed that the height of the collectors went more important for his/her efficiency of what his/her collection area. / A uniformidade da aplicação no solo de fertilizantes é um importante fator na eficiência de uso dos fertilizantes e seu efeito para as plantas. Os distribuidores de fertilizantes a lanço exigem algumas regulagens básicas no que concerne à vazão e largura de trabalho. Os ensaios de largura de trabalho e uniformidade de distribuição são de difícil execução para o agricultor por exigirem equipamentos, recursos e métodos complexos. Portanto, este trabalho teve como objetivo avaliar coletores alternativos para tornar mais acessível a regulagem e avaliação de distribuidores de fertilizantes sólidos a lanço. O trabalho foi realizado na Fundação Agrária de Pesquisa Agropecuária FAPA, localizada no distrito de Entre Rios, município de Guarapuava - Paraná. Foram utilizados quatro diferentes conjuntos de coletores: i) Coletores construídos segundo a norma ISO 5690/1; ii) Coletores de polietileno (bandejas plásticas) com sombrite para evitar o ricochete de material; iii) Coletores formados por caixas de leite longa vida; iv) Coletores formados por vasos de polietileno (Número 3,5). Para a avaliação da faixa de distribuição transversal, os coletores foram distribuídos lado a lado paralelos entre si, formando uma linha transversal ao deslocamento do trator e distribuidor. Foi utilizado um trator Ford, modelo 7630, no qual foram acoplados distribuidores: Jan, modelo Lancer Master 1200; Incomagri, modelo Sembra 1300-P AH; e Nogueira, modelo Rota Flow. Os coletores alternativos apresentaram uma retenção maior que os coletores normatizados. Esta diferença relativa entre as coletas foi maior nas extremidades do perfil de distribuição. A largura efetiva de trabalho obtida para os coeficientes de variação de 12,5, 15, 17,5 e 20% variou entre os coletores nos diferentes percursos. O coletor que mais se assemelhou a norma foram os vasos de polietileno. Observou-se que a altura dos coletores foi mais importante para sua eficiência do que a sua área de coleta.
122

Programa computacional para avaliação da uniformidade e eficiência de aplicação em sistemas de irrigação por pivô central sob condições de quimigação

Souza, Paula Cristina de 23 June 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:02Z (GMT). No. of bitstreams: 1 Paula Cristina de Souza.pdf: 930507 bytes, checksum: 62b3bda0715d30efee22ea361d0b5c26 (MD5) Previous issue date: 2006-06-23 / Considering the importance of the evaluation of irrigation systems by central pivot with objective of determining its operational characteristics and its correct handling, the present work had as objective the elaboration of the proPIVÔ program, for Windows environment, in Visual language, which helps technicians to obtain efficiency values, in potential, of application and uniformity coefficients for irrigation systems by central pivot, and also determines the uniformity of distribution of chemical products applied by irrigation water tract. Besides, this program constitutes a didactic resource, due to the simplicity of its use, the several alternatives of data manipulation and the graphs and maps which can be obtained. The program uses an Access data base to store the rehearsals/tests, it calculates values of Heermann uniformity coefficient and Evans interpolated coefficient, generating graphs, space maps and reports. / Considerando a importância da avaliação de sistemas de irrigação por pivô central, para determinar suas características operacionais e seu correto manejo, o presente trabalho estabeleceu como objetivo elaborar o programa proPIVÔ, para ambiente Windows, em linguagem Visual Basic, que auxilia técnicos na obtenção de valores de eficiência, em potencial, de aplicação e coeficientes de uniformidade para sistemas de irrigação por pivô central, e determina também a uniformidade de distribuição de produtos químicos aplicados via água de irrigação. Além disso, o programa constitui um recurso didático, dada a simplicidade do seu uso, as inúmeras alternativas de manipulação de dados e os gráficos e mapas que podem ser obtidos. O programa utiliza uma base de dados Access para armazenar as informações dos ensaios, calcula valores de coeficiente de uniformidade de Heermann e o coeficiente interpolado de Evans, gerando gráficos, mapas espaciais e relatórios.
123

Efeito da carga hidráulica e qualidade de água na uniformidade de sistema de irrigação por gotejamento

Hermes, Eliane 11 February 2010 (has links)
Made available in DSpace on 2017-05-12T14:48:07Z (GMT). No. of bitstreams: 1 Eliane Hermes.pdf: 848736 bytes, checksum: 5c07576b6d2d54fb662b1b0b914ecc1b (MD5) Previous issue date: 2010-02-11 / Universidade Federal do Paraná / One of the factors that should be considered when purchasing an irrigation system is related to its application uniformity. It has a direct influence on agricultural productivity, which tends to increase with the improvement of this uniformity. The fertigation through drip irrigation system provides better application uniformity, therefore contributing to water and energy economy. The cassava wastewater provides a serious environmental problem when released directly into water bodies, and due to this, the application in the soil has shown beneficial effects when used in agriculture as organic fertilizer. Thus, the objective of this study was to evaluate four different treatments with six replicates each, considering two factors: hydraulic loading (1,0 and 1,5 m) and type of applied water: clean water and diluted cassava processing wastewater. The system was installed in the Experimental Center of Agricultural Engineering (NEEA), belonging to the State University of West of Paraná (UNIOESTE), in Cascavel - Paraná. Physicochemical characterization of water was performed to determine the clogging risk to the system by monitoring the parameters of pH, electrical conductivity (EC), dissolved solids (DS) and turbidity and determined the coefficients of flow variation (CV), emission uniformity (EU) and Christiansen Uniformity (CUC). In both treatments, with a hydraulic load of 1,5 m, 25 tests were performed in order to control statistical techniques and establishment of process capacity indices to the coefficients obtained. In treatments with cassava processing wastewater there was a decrease in the values of flow over time, with an average reduction of 20,02 and 18,84% for the hydraulic load of 1,0 and 1,5 m, respectively. The water used for irrigation in drip system showed pH values that can cause severe risk of clogging the equipment used. The quality of the diluted cassava processing wastewater used in the fertigation treatments had turbidity values outside the standards of CONAMA. The CV and the EU showed higher results in the treatment of irrigation with a hydraulic load of 1.5 m, being classified as excellent. Only the individual measures Shewhart chart of the CUC in the trials of fertigation was found in statistical control. The values of process capability indices showed a relationship with the coefficient of uniformity which are inversely proportional to CV and and directly proportional to EU and CUC. The process capability index was able to diagnose whether irrigation has the ability to maintain control and constant, or whether it will be able to maintain acceptable levels of uniformity. / Um dos fatores que devem ser considerados na aquisição de um equipamento de irrigação está relacionado à sua uniformidade de aplicação, pois ela influencia diretamente na produtividade agrícola, que tende a aumentar com a melhoria desta uniformidade. A fertigação por meio de um sistema de irrigação por gotejamento propicia uma melhor uniformidade de aplicação, promovendo a economia de água e energia. A água residuária de mandioca ocasiona um sério problema ambiental, quando lançada diretamente em corpos hídricos, porém sua aplicação no solo tem demonstrado efeitos benéficos, quando usada como adubo orgânico na agricultura. Deste modo, o objetivo deste estudo consistiu na avaliação da qualidade da irrigação e fertigação com água residuária de processamento de mandioca. O sistema foi instalado no Núcleo Experimental de Engenharia Agrícola (NEEA), pertencente à Universidade Estadual do Oeste do Paraná (UNIOESTE), no município de Cascavel Paraná. Foram realizados quatro tratamentos distintos com seis repetições cada, considerando-se dois fatores: carga hidráulica (1,0 e 1,5 m) e tipo de água aplicada: água tratada e água residuária de processamento de mandioca diluída. Foi realizada a caracterização físico-química das águas para verificar o risco de entupimento do sistema por meio do monitoramento dos parâmetros de pH, condutividade elétrica (CE), sólidos dissolvidos (SD) e turbidez e foram determinados os coeficientes de variação de vazão (CVQ), de uniformidade de emissão (UE) e de uniformidade de Christiansen (CUC). Nos dois tratamentos com carga hidráulica de 1,5 m foram realizados 25 ensaios para a utilização de técnicas de controle estatístico de qualidade e estabelecimento de índices de capacidade de processo dos coeficientes obtidos. Nos tratamentos com água residuária de processamento de mandioca houve um decréscimo nos valores de vazão ao longo do tempo, com redução média de 20,0 e 18,8% para a carga hidráulica de 1,0 e 1,5 m, respectivamente. A água utilizada para irrigação no sistema de gotejamento apresentou valores de pH que podem provocar risco severo de entupimento ao equipamento utilizado. A qualidade da água residuária de processamento de mandioca diluída utilizada nos tratamentos de fertigação obteve valores de turbidez fora dos padrões do CONAMA. O CVQ e UE apresentaram resultados mais elevados no tratamento de irrigação com carga hidráulica de 1,5 m, sendo classificados como excelente. Apenas o gráfico de medidas individuais de Shewhart do CUC nos ensaios de fertigação encontrou-se sob controle estatístico. Os valores dos índices de capacidade de processo apresentaram uma relação com os coeficientes de uniformidade inversamente proporcionais ao CVQ e diretamente proporcionais a UE e CUC. O índice de capacidade do processo mostrou-se capaz de diagnosticar se a irrigação tem capacidade de se manter sob controle e constante, ou seja, se será capaz de manter níveis aceitáveis de uniformidade.
124

Influência da estrutura ímpar em pneus de lonas cruzadas (\'cross-ply\'). / Influence of an odd structure in cross ply tires.

Zucato, Igor 21 November 2006 (has links)
O pneu é o único vínculo entre o veículo e o solo, é ele que transmite toda a potência e carga, e garante a dirigibilidade e condução do automóvel. A estrutura resistente de um pneu é um dos pontos de maior importância para o rendimento, tipo de aplicação e segurança. E conhecê-la é condição primária para o projeto. Pneus convencionais, via de regra, apresentam uma estrutura par de lonas cruzadas (cross-ply), dispostas em ângulos opostos, menores que 90º. Este trabalho visa avaliar as influências de uma estrutura ímpar de lonas cruzadas, em pneus convencionais. Objetiva-se com isso uma redução na matéria prima e uma otimização no tempo de processo. As influências da estrutura ímpar foram verificadas através de uma análise de elementos finitos, examinando o andamento das tensões internas na carcaça do pneu e observando a geometria da região de contato pneu/solo. Verificou-se também a variação da uniformidade utilizando-se do ensaio SAE J332 em uma máquina Akron FD90. A utilização de uma estrutura ímpar, em pneus de lonas cruzadas, acarreta numa deformação na região de contato pneu/solo, devido ao desbalanceamento de tensões nos fios da carcaça, um aumento das componentes de ply-steer e uma variação de força lateral nas componentes dinâmicas avaliadas. A utilização de uma estrutura ímpar deve ser cuidadosamente selecionada dependendo da velocidade, severidade e condições de utilização. / The tire is the only bond between the vehicle and the ground, is it that transmits all the power and load, and guarantees the driven and conduction of the automobile. The resistant structure of a tire is one of the most important factors for the efficiency, type of application and security. Knowing these parameters is the primary condition to design a tire. Conventional tires, usually have a pair structure, made of crossed plies (cross-ply) in opposite angles lesser than 90º. The present work aim to evaluate the influence of an odd cross-ply structure, in conventional tires, looking forward to a material reduction and also an optimization on time process. The influence of an odd structure was evaluated through a finite element analysis, examining the cord stress at the tire carcass and the tire/ground contact region (foot-print). The variation of the uniformity was also verified through a SAE332 test did on Akron FD90 machine. It was observed that the use of an odd structure in cross-ply tires cause a tire/ground contact region deformation, because of the unbalance internal cord stress (at the carcass), and an increase of uniformities components (ply-steer and variation of lateral force). The use of an odd structure must be carefully selected, depending on the speed, severity and condition of use.
125

Dinâmica de entupimento de gotejadores em função da aplicação de água rica em ferro /

Brauer, Rigléia Lima, 1980- January 2010 (has links)
Orientador: Raimundo Leite Cruz / Coorientador: Roberto Lyra Villas Bôas / Banca: Dirceu Maximino Fernandes / Banca: João Luis Zocoler / Helton Rogério Mazzer / Resumo: Com o propósito de avaliar a susceptibilidade de dois tipos de gotejadores ao processo de entupimento por ferro, foi conduzido um experimento em uma bancada de ensaios no Laboratório de Ensaio de Equipamentos para Irrigação do Departamento de Engenharia Rural da Universidade Estadual Paulista "Júlio de Mesquita Filho" - Campus de Botucatu. O ensaio corresponde ao processo de entupimento, e foram avaliados os seguintes modelos de gotejadores NaanDanJain: NaanPC laranja e NaanPC azul. Foram utilizados segmentos de tubos, totalizando 25 emissores, onde se mediu a vazão com a pressão de 150 KPa, com três repetições para cada gotejador. A água utilizada no ensaio foi proveniente do lago do Departamento de Engenharia Rural que é comumente utilizado para irrigações de experimentos. Posteriormente foram calculados: Vazão Média, Coeficiente de Variação de Vazão (C.V.Q), Uniformidade de Distribuição da Água (C.U.D), Coeficiente de Uniformidade de Christiansen (C.U.C) e Vazão Relativa (V.R.). Foi utilizado delineamento experimental estatístico de blocos inteiramente casualizados, com fatorial 2x2x7, com três repetições, sendo o primeiro fator os tratamentos com ferro, o segundo fator os tipos de gotejadores e o terceiro fator o tempo. Os resultados obtidos não apontaram diferença significativa nas diferentes doses de ferro. Entretanto, os resultados apontaram diferença significativa na interação gotejador x tempo e coeficiente de uniformidade de Christiansen (CUC) e vazão relativa (V.R.) / Abstract: The objective of this study was to evaluate the susceptibility of clogging by iron in two types of drippers using a test bank located at the Irrigation Experimental Laboratory in the Department of Agricultural Engineering of "Sao Paulo State University Julio de Mesquita Filho "- Campus of Botucatu, Sao Paulo state. The experiment aims to study the clogging process, evaluating 2 models of drippers NaanDanJain: NaanPC orange and NaanPC blue. It was used tube segments, totaling 25 drippers, using pressure of 150 kPa, with 3 repetitions for each dripper. The water used in the test was from the lake of the Department of Agricultural Engineering which is commonly used for irrigation experiments. It was calculated: the average discharge, the variation coefficient of discharge (CVQ), the uniformity coefficient of distribution (CUD), the uniformity coefficient of Christiansen (CUC) and the relative discharge (VR). It was used statistical experimental design of randomized blocks, with a 2x2x7 factorial with three replications, with the first factor treatment with iron, the second factor the types of drippers and the third factor the time. The results showed no significant difference in different doses of iron. However, the results indicated significant differences in drip x time interaction and the Christiansen uniformity coefficient (CUC) and relative discharge rate (VR) / Mestre
126

Recherche du boson de Higgs dans le canal de désintégration en deux photons avec le détecteur ATLAS au LHC

Bernat, P. 24 June 2010 (has links) (PDF)
Cette thèse a traité trois différents aspects ayant trait à la recherche du boson de Higgs dans le canal de désintégration en deux photons avec le détecteur ATLAS. Le premier est une étude sur l'uniformité intrinsèque du calorimètre électromagnétique (EM) d'ATLAS en utilisant la mesure du temps de dérive des électrons d'ionisation. Environs 500 000 signaux provenant de rayons cosmiques sont enregistrés et sont comparés à la forme du signal prédite en utilisant la méthode FPM (pour First Principle Method). L'ajustement de la forme prédite à celle mesurée permet de mesurer le temps de dérive des électrons d'ionisation de l'argon liquide. L'uniformité du temps de dérive dans le compartiment Middle calculée par blocs de taille 0.1 x 0.1 dans le plan (η,φ) est estimée à 1.27 ± 0.03%. L'impact de la variation du temps de dérive sur l'uniformité de la réponse du calorimètre est estimée à 0.29 ± 0.01%. En tenant compte de la variation de l'épaisseur des plaques de plomb qui constituent le milieu passif et qui ont été mesurées par ailleurs, l'uniformité intrinsèque du calorimètre est estimée à 0.34%. La vitesse de dérive des électrons mesurée dans les différents compartiments du calorimètre est en moyenne V_{D(E = 1 kV/mm) = 4.58 ± 0.07 mm.μ s^-1 en bon accord avec des mesures antérieures de la vitesse de dérive des électrons dans l'argon liquide à la température de 88.5K. Le second aborde la question de l'estimation de la matière en amont du calorimètre, utilisant une cartographie du détecteur interne. Cette mesure est faite relativement au nombre de conversions dans le tube à vide (beam pipe) de manière à être indépendante du flux initial de photons. Une connaissance précise de la matière en amont du calorimètre est essentielle à la calibration en énergie des électrons et photons reconstruits dans le calorimètre. Puisqu'une large fraction des photons proviennent de mésons π^0, le flux initial de photons qui intervient dans le taux de conversions dans le beam pipe est normalisé aux désintégrations Dalitz du π^0. L'observable qui permet de comparer les données aux simulations Monte-Carlo (MC) est le rapport du nombre de conversions reconstruites dans le beam pipe et du nombre de Dalitz reconstruits. Ce rapport estimé avec les données de collision à une énergie de 7 TeV dans le centre de masse donne un bon accord sur la mesure de la matière dans le beam pipe avec la prédiction du MC : X/X_0 = 0.669 ± 0.033(stat) ^+0.013_-0.080(syst)%, X/X_0 = 0.709 ± 0.028(syst) %, et X/X_0 = 0.709 ± 0.028(syst) %respectivement. Le dernier est l'étude de la normalisation du signal et du bruit de fond ainsi que l'analyse du potentiel discriminant dans l'analyse inclusive du canal H → γγ. Différentes simulations MC sont utilisées pour estimer une normalisation à l'ordre NLO du signal et du bruit de fond irréductible (γγ) ainsi que les erreurs systématiques associées. Celles-ci représentent respectivement 16% et 26% de la section efficace totale. Le pouvoir discriminant de l'impulsion transverse du système diphoton et du cosθ* est aussi étudié. En particulier, une forte corrélation entre le cosθ* et la masse invariante diphoton est observée. Le bruit de fond semi-réductible (γ-jet) est normalisé à NLO avec 27% d'erreurs systématiques. Une nouvelle normalisation qui s'applique après l'identification des photons est proposée. Elle prend en compte la différente réjection des jets provenant de quark ou de gluon et est estimée à 1.9 ± 0.6. Les perspectives d'exclusion du boson de Higgs dans le canal diphoton à 10 TeV et l'extrapolation à 7 TeV pour un luminosité intégrée de 1 f b^−1 sont présentées. Dans le dernier scénario, environ 5 fois le Modèle Standard est exclu à 95% de niveau de confiance pour une masse du boson de Higgs autour de 120 GeV/c^2 .
127

Traitement des signaux thermométriques pour la caractérisation des matériaux : analyse et quantification du comportement des revêtements / Thermometric signal processing for characterization of materials : analysis and quantification of the behavior of coatings

Abdelmoula, Sihem 02 October 2017 (has links)
Les exigences de qualité des produits ainsi que des normes environnementales et énergétiques de plus en plus drastiques nécessitent le développement de technologies de fonctionnalisation de surface en particulier celles qui s’appuient sur les procédés de revêtement par dépôt de couches minces. Le contrôle de la qualité de surface revêtue présente un enjeu industriel d’envergure. En effet, il n’existe pas à l’heure actuelle de technique d’inspection non destructive qui allie à la fois rapidité, fiabilité et flexibilité pour le contrôle de l’uniformité de revêtement. Pour répondre à cette problématique, ce travail de thèse porte sur le développement d’une technique d’inspection basée sur la thermographie active. Après étude expérimentale et numérique de la réponse thermique de surfaces bicouches, nous proposons une première méthodologie d’exploitation des mesures issues d’une excitation ponctuelle (laser) et surfacique (flash(s)). L’approche mise en place s’appuie sur l’implantation d’un algorithme des moindres carrés partiels (PLS NIPALS). Celui-ci a été testé sur plusieurs matériaux conducteurs et non conducteurs et dans différentes configurations expérimentales puis comparé à la méthode de contrôle conventionnelle par courants de Foucault (pour les matériaux conducteurs). La méthode développée permet d’extraire la signature thermique intrinsèque de l’hétérogénéité d’épaisseur du revêtement. Une deuxième approche a été explorée, elle s’appuie sur la mise en œuvre des nouveaux outils que nous offre le « Deep Learning ». Les premiers résultats obtenus semblent prometteurs. L’ensemble des résultats ouvre le champ vers une exploitation industrielle de la thermographie infrarouge pour le contrôle non destructif de revêtement. / Product quality requirements as well as increasingly drastic environmental and energy standards require the development of surface functionalization technologies, particularly those based on thin film coating processes. The quality control of coated surface presents an important industrial challenge. Indeed, actually there is any non-destructive inspection technique that combines speed, reliability and flexibility for coating uniformity inspection. To respond this challenge, this work focuses on the development of an inspection technique based on active thermography. After experimental and numerical studies of thermal responses of bilayer surfaces, we propose firstly a measurement methodology based on a point (laser) and surface excitation (flash (s)). The approach is based on the implementation of a partial least squares algorithm (PLS-NIPALS). It was tested on several conductive and non-conductive materials and in various experimental configurations and compared to the conventional eddy current control method (for conductive materials). The developed method makes it possible to extract the intrinsic thermal signature of the coating thickness heterogeneity. A second approach has been explored, based on the classification algorithm based on Deep Learning tool. The first results seem promising. The overall results open the opportunity to an industrial exploitation of infrared thermography for non-destructive coating testing.
128

Desempenho de gotejadores com uso de efluente de esgoto doméstico tratado

Pletsch, Talita Aparecida [UNESP] 19 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-19Bitstream added on 2014-06-13T19:55:05Z : No. of bitstreams: 1 pletsch_ta_me_botfca.pdf: 291890 bytes, checksum: aa6f0fe8c43751bb86a4f584e118dc67 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / O uso de águas residuárias de esgoto doméstico tratado permite uma otimização dos recursos hídricos disponíveis, melhorando assim a sua oferta. O uso para fins agrícolas a cada dia se mostra uma possibilidade vantajosa de reúso, pois aceita o uso de águas com qualidade inferior ao exigido pelo abastecimento urbano e necessita de grandes quantidades. Segundo Almeida et al.(2006), a uniformidade possui maior importância quando o sistema de irrigação é utilizado para fazer a fertirrigação, pois, para o bom desempenho, é necessário o conhecimento das características hidráulicas do emissor e uniformidade de aplicação de água do sistema de irrigação utilizado. Diante desta realidade de reúso de efluentes para irrigação por gotejamento, o presente trabalho teve como objetivo determinar a vazão dos gotejadores, a curva relação vazão-pressão, a sua equação característica, o coeficiente de variação de vazão (CVQ), e também avaliar a uniformidade de aplicação de água, calculando os seguintes coeficientes: coeficiente de uniformidade de distribuição (CUD), o coeficiente de uniformidade de Christiansen (CUC) e o coeficiente de uniformidade estatístico (CUE), do tubo gotejador da marca Netafim, modelo Tiran 17, utilizado para a irrigação com água residuária de esgoto doméstico tratado.O experimento foi realizado em uma bancada de ensaios no Laboratório de Irrigação da UNESP-FCA, Campus de Botucatu-SP. Foi utilizado um segmento do tubo gotejador contendo 25 emissores, onde se mediu a vazão com as seguintes pressões: 40, 50, 80, 100, 120, 150, 200, 250, 300 kPa, com quatro repetições para cada gotejador. Após os ensaios, o tubo gotejador foi submetido a 1000 horas de trabalho com água residuária de esgoto doméstico tratado. Foram realizados os mesmos ensaios iniciais após 500 horas e 1000 horas de trabalho com água tratada... / The use of wastewater of treated household drain allows an optimization of available hydro resources, increasing the offer of a scarce product. The use in agriculture becomes, each day, more advantageous for its reuse due to its acceptance of water with a lower quality in view of the water demanded by the urban supply and the demanding of a great quantity. According to Almeida et al.(2006), the uniformity is more important when the system of irrigation is used to make the fertirrigation. For a good performance it’s important to know the hydraulic characteristics of the emitter and uniformity of water application of the irrigation system. In order of the reuse of effluents for drip irrigation, this paper aims to determine the flow of drippers, the curve relation flow-pressure, its equation, the flow coefficient of variation (CVQ) as well as to evaluate the uniformity of water application by calculating the follow coefficients: distribution uniformity coefficient (CUD), Christiansen uniformity coefficient (CUC) and the statistical uniformity coefficient (CUE) of the drip pipeof the Netafim brand, model Tiran 17, used for irrigation with wastewater of treated household drain. The experiment was accomplished in a test bank in the Irrigation Laboratory of UNESP-FCA, Campus of Botucatu in São Paulo state. It was used 25 drippers where the flow was measured with increasing pressures of 40, 50, 80, 100, 120, 150, 200, 250, 300 kPa, with four repetitions for each dripper. After the tests the drip pipe was submitted to 1000 hours of work with wastewater of treated household drain. The same tests were carried out after 500 hours and 1000 hours of working but with treated water. The results of the new pipe after the 500 working hours with treated household effluents for CVQ, were classified as good, according to the ABNT (1987) chart. The CUD, CUC and CUE not only before but also... (Complete abstract click electronic access below)
129

Estudo da uniformidade de emissão de água utilizando diferentes espaçamentos entre gotejadores na linha lateral

Andrade, Luiz Antonio de [UNESP] 08 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-08Bitstream added on 2014-06-13T20:43:44Z : No. of bitstreams: 1 andrade_la_dr_botfca.pdf: 831598 bytes, checksum: b06b99430e825b80d7ec37981bcbe1c5 (MD5) / Universidade Estadual Paulista (UNESP) / A irrigação por gotejamento no Brasil está crescendo no cultivo de hortaliças e frutas de ciclo anual. O adequado dimensionamento do projeto de irrigação por gotejamento visando altos Coeficientes de Uniformidade de Emissão de água é coerente com a pressão da sociedade pelo uso racional dos recursos naturais, especialmente a água. A utilização de linhas laterais mais longas promove redução de custos na instalação do projeto, entretanto pode reduzir a uniformidade de emissão de água, sendo que a otimização deste fator é importante objetivo de todo projeto criteriosamente executado. Propôs-se um modelo de mangueira gotejadora com dois segmentos, sendo o ultimo com um espaçamento padrão, e o segmento inicial com um espaçamento especial entre os emissores, com o objetivo de obter linhas mais longas sem prejudicar o Coeficiente de Uniformidade de Emissão de água. Mangueira gotejadora dimensionada teoricamente conforme o modelo proposto, com lateral de 150,6 m sendo 59,7 m iniciais com espaçamento entre emissores de 0,35 m associada com 90,9 m finais com distancia entre gotejadores de 0,30 m apresentou variação de vazão de 8,05 % e CUECVf de 97,62% e foi 36% mais longa que a mangueira gotejadora com único espaçamento de 0,30 m, com variação de vazão de 10 %, e CUECVf de 94,71.Ganhos semelhantes foram obtidos com os espaçamentos padrões de 0,40 e 0,50 m. Concluiu-se que modelo proposto tem possibilidade de ser aplicado na pratica da irrigação por gotejamento em cultivo adensado, por apresentar melhor CUE, lateral mais longa e menor variação de vazão. / The use of drip irrigation in horticultural and annual cycle fruits in Brazil is growing. The correct sizing of a drip irrigation project, using High Emission Uniformity Coefficients, is in accordance with society's pressure for a rational use of natural resources. Sizing longer lateral irrigation lines promotes a cost reduction in the installation costs of a project. A model for a drip irrigation lateral composed of two segments is proposed; the last having a standard spacing, the initial segment having a special spacing between emitters, higher than the standard, with the objective of obtaining longer laterals, without decreasing the Emission Uniformity Coefficient of water, EUC.A theoretically dimensioned drip hose, in accordance with the proposed model, with a total length of 150.6 m, having the initial 59.7 m an emitter spacing of 0.3508 m, while the final 90.9 m an emitter spacing of 0.30 m, presented a flow variation of 8.05% and an EUC of 97.62%. It is 36% longer than a drip irrigation hose with a 0.30 m emitter spacing, with a 10% flow variation and a EUC of 94.71%. A substitution of the standard lateral model for the proposed lateral model still needs a field trial validation in order to justify its use, considering that the commercial production of this model is viable.
130

Development of Uniform Artificial Soil Deposition Techniques on Glass and Photovoltaic Coupons

January 2016 (has links)
abstract: Soiling is one of the major environmental factors causing the negative performance of photovoltaic (PV) modules. Dust particles, air pollution particles, pollen, bird droppings and other industrial airborne particles are some natural sources that cause soiling. The thickness of soiling layer has a direct impact on the performance of PV modules. This phenomenon occurs over a period of time with many unpredictable environmental variables indicated above. This situation makes it difficult to calculate or predict the soiling effect on performance. The dust particles vary from one location to the other in terms of particle size, color and chemical composition. These properties influence the extent of performance (current) loss, spectral loss and adhesion of soil particles on the surface of the PV modules. To address this uncontrolled environmental issues, research institutes around the world have started designing indoor artificial soiling stations to deposit soil layers in various controlled environments using reference soil samples and/or soil samples collected from the surface of PV modules installed in the locations of interest. This thesis is part of a twin thesis. The first thesis (this thesis) authored by Shanmukha Mantha is related to the development of soiling stations and the second thesis authored by Darshan Choudhary is associated with the characterization of the soiled samples (glass coupons, one-cell PV coupons and multi-cell PV coupons). This thesis is associated with the development of three types of indoor artificial soiling deposition techniques replicating the outside environmental conditions to achieve required soil density, uniformity and other required properties. The three types of techniques are: gravity deposition method, dew deposition method, and humid deposition method. All the three techniques were applied on glass coupons, single-cell PV laminates containing monocrystalline silicon cells and multi-cell PV laminates containing polycrystalline silicon cells. The density and uniformity for each technique on all targets are determined. In this investigation, both reference soil sample (Arizona road dust, ISO 12103-1) and the soil samples collected from the surface of installed PV modules were used. All the three techniques are compared with each other to determine the best method for uniform deposition at varying thickness levels. The advantages, limitations and improvements made in each technique are discussed. / Dissertation/Thesis / Masters Thesis Mechanical Engineering 2016

Page generated in 0.0576 seconds