• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 64
  • 16
  • 13
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 218
  • 54
  • 34
  • 33
  • 33
  • 31
  • 29
  • 29
  • 29
  • 24
  • 20
  • 20
  • 19
  • 17
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Diferentes concentrações de ferro na água, seu efeito na cultura do girassol ornamental e no desempenho de gotejador

Oliveira, Alessandra Conceição de [UNESP] 18 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-18Bitstream added on 2014-06-13T20:15:43Z : No. of bitstreams: 1 oliveira_ac_me_botfca.pdf: 2125510 bytes, checksum: 099181f79e2b1cd87da05d0eb244d6bb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O presente trabalho teve como objetivo avaliar a produtividade do girassol ornamental cultivar ‘Sunflower F1 Sunbright Supreme’ e o desempenho dos emissores gotejadores com diferentes concentrações de ferro na água de irrigação. O experimento foi conduzido no Departamento de Engenharia Rural, Faculdade de Ciências Agronômicas, pertencente à Universidade Estadual Paulista – UNESP, Campus de Botucatu, Estado de São Paulo, em duas fases: a I compreendido de 08 de Maio a 13 de Julho de 2009, e a II em 01 de Dezembro de 2009 a 10 de Maio de 2010. Na fase I o delineamento experimental foi inteiramente casualizado, fatorial 4 x 2 (4 teores de ferro e 2 emissores), com 4 repetições e 20 plantas por parcela, um vaso compostas por uma planta, constituindo um total de 160 vasos, onde testaram uma testemunha e três doses de ferro na água (zero; 0,5; 1,5; e 3,0 mg L -¹), e dois tipos de gotejadores um autocompensante e outro normal. Ao final do experimento, foram avaliados os seguintes parâmetros de desenvolvimento das plantas: A altura da parte aérea (cm), comprimento da haste (cm) e sistema radicular (cm), diâmetro de haste (mm), número de folha, área foliar (cm2), massa seca da parte aérea, do sistema radicular, das inflorescências e total (g), diâmetro de inflorescências: diâmetro do capítulo floral (mm), e diâmetro do disco (mm). Na fase II o delineamento experimental foi inteiramente casualizado, três doses de ferro na água (0,5; 1,5; e 3,0 mg L -¹), e dois tipos de gotejadores um autocompensante e outro normal (Netafim e Amanco) em 3 repetições e 20 emissores cada. As avaliações dos gotejadores foram: Vazão média (Q), Coeficiente de uniformidade de distribuição (CUD), Coeficiente de variação de fabricação (CV) e Coeficiente uniformidade de Christiansen (CUC). Os resultados foram submetidos à análise de variância pelo teste F. As médias foram comparadas... / The aim of this present work was to evaluate the yield of ornamental sunflower “Sunflower F1 Sunbright Supreme” cultivar and the performance of drippers with different iron concentrations on irrigation water. The experiment was carried out on Rural Engeneering Department, Agronomic Sciences College of Paulista State University – UNESP, Campus of Botucatu, São Paulo, with two steps. The step I was realized may 8th to July 13th 2009 and the second step on December 1st 2009 to May 10th 2010. The first step was design entirely at random, with factorial scheme 4 X2 (four iron levels and two drippers) with 4 repetitions, and 20 plants per treatment composed by one plant, totalizing 160 pots where a check treatment was tested and 3 doses of iron on water (zero; 0,5; 1,5; and 3,0 mg.L-1) and two types of drippers: self-compensating and normal. At the end of the experiment were evaluated the parameters for plants development: The height of air part (cm) length of the stem (cm) and root system (cm) diameter Shank (mm), number of leaf, leaf area (cm2), dry mass of air part, of the system root, of the inflorescences and total (g) inflorescences diameter: diameter of chapter floral (mm) and diameter of the disk (mm). In step II trial design was entirely at random, three doses of iron in water (0.5; 1.5; and 3.0 mg L-1), and two types of self-compensating dripper and another normal (Netafim and Amanco) with 3 repetitions and 20 drippers each. The evaluations of drippers were: average flow (Q), Coefficient of uniformity of distribution (CUD), coefficient of variation of manufacturing (CV) and coefficient of uniformity of Christiansen (CUC). The results were subjected to analysis of variance by f-test. Averages were compared by Tukey's test 5% probability for drippers and Regression to 5% probability for iron doses. Concluded that the production of ornamental sunflower solution with residual water... (Complete abstract click electronic access below)
82

Uniformidade de distribuição temporal e espacial do KCL na fertirrigação, em um sistema de irrigação por gotejamento

Oliveira, Marcus Vinicius Araujo Mello de [UNESP] 01 July 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-07-01Bitstream added on 2014-06-13T18:30:32Z : No. of bitstreams: 1 oliveira_mvam_me_botfca.pdf: 1922474 bytes, checksum: deeb3be5eae142e54b8922692fcabe16 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As vantagens advindas do uso da fertirrigação para a agricultura brasileira esbarram na ausência de trabalhos que busquem trazer informações sobre muitos aspectos relacionados à técnica. O presente trabalho, conduzido na Faculdade de Ciências Agronômicas - UNESP, procura diminuir essa carência de conhecimento comparando três injetores de fertilizante em condições de campo, encontrando e indicando o menor tempo possível para injeção de fertilizantes em um sistema de irrigação por gotejamento. O experimento foi instalado na área de experimentação do Departamento de Engenharia Rural da referida faculdade, localizada no município de Botucatu - SP, ocupando uma área de 0,7 ha. O sistema de irrigação foi dimensionado buscando simular um setor de um pomar de citros, composto basicamente por um cabeçal de controle, uma linha principal, uma linha de derivação e seis linhas laterais com 200 m de comprimento cada. Os equipamentos utilizados para injeção de fertilizantes foram: um injetor venturi, uma bomba dosificadora elétrica e uma bomba dosificadora hidráulica proporcional. Como forma de estudar a distribuição espacial e temporal do íon potássio no sistema de irrigação, quatro tempos de injeção foram escolhidos: 10, 15, 20 e 25 minutos; sendo recolhidas amostras de solução em diferentes momentos durante e após a injeção do produto. As amostras coletadas tiveram seu teor de K determinado, via fotometria de chama, com a finalidade de inferir-se a uniformidade de distribuição do íon nos diferentes tratamentos. Concluiu-se que quanto menor a distância percorrida pelo fertilizante e mais longo o tempo de injeção, maior é a uniformidade de distribuição. Os injetores utilizados não apresentaram diferença estatística quanto uniformidade de aplicação de fertilizantes... / The advantages of fertigation use for Brazilian agriculture encounter a lack of works with information about this technique. The objective of this was to supply the lack of knowledge comparing three fertilizers injection in field conditions. The results indicated the smallest possible time for injection of fertilizers in a trickle irrigation system. The experiment was carried out in the area of experimentation of the Department of Rural Engineering of Faculty of Agronomic Sciences - UNESP, in Botucatu - SP, with an area of 0,7 ha. The irrigation system was designed searching into simulate a citrus orchard, composed basically for head control, a main line, a derivation line and six lateral lines with 200 m of length each. The equipment used for injection of fertilizers were: a venturi injector, an electric pump and a proportional hydraulic pump. Four times, 10, 15, 20 and 25 minutes, of injection were chosen to study the space and temporary distribution of the ion potassium in the irrigation system,:. The solution samples were picked up in different moments during and after the injection of the product. The contents of K were measured in the samples, using flame fotometric, with the purpose of determining the uniformity of distribution of ion in different treatments. The results showed that as much as shorter the distance and as much as longer the injection time, better is the uniformity of distribution. There was no difference in uniformity of distribution of potassium among the used injectors...(Complete abstract, click electronic access below)
83

Uso de inversor de frequência em sistema de irrigação do tipo pivô central e seu efeito na lâmina e uniformidade de distribuição de água

Lima, Adenilsom dos Santos [UNESP] 23 January 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:43Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-01-23Bitstream added on 2014-06-13T19:03:16Z : No. of bitstreams: 1 lima_as_dr_botfca.pdf: 2285385 bytes, checksum: 2981c4b472020de7602b8217b232d18a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Um sistema de irrigação deve possibilitar o manejo eficiente da lâmina de água aplicada. Para tal, é necessário avaliar o desempenho do sistema em operação. Este trabalho teve por objetivo avaliar a uniformidade de distribuição e lâmina de água aplicada por um equipamento de irrigação do tipo pivô central em função da variação da velocidade de rotação no conjunto motobomba com o uso de um inversor de freqüência e o efeito da posição da linha lateral nesses parâmetros. O trabalho foi realizado na Fazenda Nossa Senhora Aparecida, no município de Coronel Macedo – SP. Foram testadas duas condições de operação: Ensaio 1 com pressão constante na saída do conjunto motobomba e Ensaio 2 com rotação variável de acordo com a necessidade de altura manométrica. Para cada condição de operação foram testadas três posições de linhas coletoras de água: aclive de 3,45%, nível e declive de 11,78%. O delineamento experimental foi inteiramente casualizado, sendo feitas três repetições em cada posição testada. Aplicou-se a análise de variância seguida do teste de Tukey. O valores médios do coeficiente de uniformidade de Heermann & Hein foi 90,02% e 88,85% para os Ensaios 1 e 2, respectivamente, qualificando a uniformidade de acordo com a Norma da ABNT como muito boa e boa. Também, a posição da linha lateral influenciou 2 significativamente na rotação do conjunto motobomba e conseqüentemente no consumo de energia. A lâmina média ponderada de irrigação aplicada foi 5,84 mm e 5,71 mm para os Ensaios 1 e 2, respectivamente, variando dentro de cada ensaio significativamente (5%) entre as posições de declive versus aclive e nível. Concluiu-se que para os Ensaios 1 e 2 a rotação e a posição da linha lateral influenciaram significativamente na uniformidade de distribuição, lâmina de água aplicada e consumo de energia, exceto para o Ensaio... / An irrigation system should enable the efficient management of the water depth applied. Therefore, it is necessary to evaluate the performance of the system in operation. This study aimed to evaluate the uniformity distribution and water depth applied in center pivot irrigation systems according to the change in speed of rotation of set motor pump with a frequency inverter and the effect of the position of the lateral line in these parameters. The study was conducted at the Nossa Senhora Aparecida Farm, in the city of Coronel Macedo – SP. Two operation conditions were tested: Test 1 with constant pressure in the output of set motor pump and Test 2 with variable rotation in accordance with the need of the pressure of system. For each condition of operation were tested three positions of lines of collecting: incline of 3.45%, level and the slope of 11.78%. The experimental design was completely randomized, and three repetitions at each position of lines collecting tested. It was applied to analysis of variance followed by Tukey test. The average value of the coefficient of uniformity of Heermann & Hein was 90.02% and 88.85% for Tests 1 and 2, respectively, discribing the uniformity according to the Standard ABNT as very good and good. Also, the position of the lateral line significantly influenced the rotation of set motor pump and consequently in energy consumption. The mean weighed depth of irrigation applied was 5.84 mm and 5.71 mm for Tests 1 and 2, respectively, varying in each test significantly (5%) between positions of the slope versus incline and level. It was concluded that for the Tests 1 and 2, the rotation and the position of and lateral line influenced significantly... (Complete abstract click electronic access below)
84

Spatial Temperature Uniformity and Statistical Determination of Dominant Degradation Modes in PV Modules

January 2015 (has links)
abstract: This is a two-part thesis. Part 1 of this thesis investigates the influence of spatial temperature distribution on the accuracy of performance data of photovoltaic (PV) modules in outdoor conditions and provides physical approaches to improve the spatial temperature distribution of the test modules so an accurate performance data can be obtained in the field. Conventionally, during outdoor performance testing, a single thermocouple location is used on the backsheet or back glass of a test module. This study clearly indicates that there is a large spatial temperature difference between various thermocouple locations within a module. Two physical approaches or configurations were experimented to improve the spatial temperature uniformity: thermally insulating the inner and outer surface of the frame; backsheet and inner surface of the frame. All the data were compared with un-insulated conventional configuration. This study was performed in an array setup of six modules under two different preconditioning electrical configurations, Voc and MPPT over several clear sunny days. This investigation concludes that the best temperature uniformity and the most accurate I-V data can be obtained only by thermally insulating the inner and outer frame surfaces or by using the average of four thermocouple temperatures, as specified in IEC 61853-2, without any thermal insulation. Part 2 of this thesis analyzes the field data obtained from old PV power plants using various statistical techniques to identify the most influential degradation modes on fielded PV modules in two different climates: hot-dry (Arizona); cold-dry (New York). Performance data and visual inspection data of 647 modules fielded in five different power plants were analyzed. Statistical tests including hypothesis testing were carried out to identify the I-V parameter(s) that are affected the most. The affected performance parameters (Isc, Voc, FF and Pmax) were then correlated with the defects to determine the most dominant defect affecting power degradation. Analysis indicates that the cell interconnect discoloration (or solder bond deterioration) is the dominant defect in hot-dry climate leading to series resistance increase and power loss, while encapsulant delamination is being the most dominant defect in cold-dry climate leading to cell mismatch and power loss. / Dissertation/Thesis / Masters Thesis Mechanical Engineering 2015
85

Uniformidade de distribuição de água em irrigação localizada com sistema de aeração, decantação e filtragem

Silva, Elcides Rodrigues da [UNESP] 21 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-21Bitstream added on 2014-06-13T19:58:01Z : No. of bitstreams: 1 silva_er_me_jabo.pdf: 2805002 bytes, checksum: 1edb5322d15c1af6d99d144fbc53004c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A pesquisa teve como objetivo avaliar o desempenho de um sistema de aeração, decantação e filtragem, quanto à prevenção de entupimento dos emissores e avaliar uniformidade de distribuição da água no sistema de irrigação por gotejamento na época de sua implantação e após um ano de utilização do sistema de prevenção. O trabalho foi realizado na Fazenda Estância Tropical, no município de Barretos – SP, no período de março de 2008 a fevereiro de 2009, realizando-se determinações físicas e químicas da água, ao longo do sistema de aeração, decantação e filtragem, que foi eficiente para a melhoria da qualidade de água, reduzindo os níveis de risco de entupimento de severo para médio e de médio para baixo. Todas as variáveis analisadas diferenciaram a qualidade da água entre os pontos de amostragem do sistema de tratamento, com exceção do Fe+2. Para sólidos em suspensão, turbidez, sólidos dissolvidos e ferro total, os valores reduziram-se pelo uso do sistema proposto, melhorando a qualidade da água. Após um ano de funcionamento do sistema de prevenção, os coeficientes utilizados para determinar a uniformidade de distribuição de água apresentaram valores acima de 80%, sendo classificados como excelente, bom e muito bom / The research aimed to evaluate the performance of aeration, sedimentation and filtration system for the prevention of emitters clogging and evaluate the water distribution uniformity of one drip irrigation system at the time of its implementation and after a year using the prevention system. The research was conducted in the Estancia Tropical farm, in the municipality of Barretos – SP, Brazil, from March 2008 to February 2009, carrying out physical and chemical determinations of water along the aeration, sedimentation and filtration system, which was efficient for improving water quality by reducing levels of risk of clogging of severe to medium and medium to low. All variables differed water quality between the collection points of the treatment system with the exception of Fe+2. For suspended solids, turbidity, dissolved solids and total iron values were reduced by the use of the proposed system, improving water quality. After a year of prevention, the coefficients used to determine the uniformity of water distribution had values above 80%, being classified as excellent, good and very good
86

Perfil radial e uniformidade de precipitação do aspersor NaanDanJain 427, em função do defletor de ajuste

Martins, Paulo Eduardo Silva [UNESP] 24 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-24Bitstream added on 2014-06-13T19:29:20Z : No. of bitstreams: 1 martins_pes_me_jabo.pdf: 724580 bytes, checksum: 607174d21f5d018ec5e111b64424e116 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O trabalho teve como objetivo avaliar o perfil radial e a uniformidade de distribuição de água do aspersor fabricado pela empresa NaanDanJain, modelo 427 1/2”M e bocal de 2,8 mm de diâmetro interno, operando com pressões de 150, 200, 300 e 400 kPa em cinco posições do defletor de ajuste (0, 20, 50, 80 e 100%). Para a determinação dos parâmetros avaliados utilizou-se o método da malha, e com o auxílio do aplicativo computacional CATCH 3D calculou-se a sobreposição das lâminas de água com dez espaçamentos. Os resultados obtidos demonstram que o defletor de ajuste influencia o raio de molhamento, o perfil de distribuição e a uniformidade de aplicação de água e mostrou-se como um mecanismo importante, pois permite comportamento diferenciado para o aspersor, garantindo ampla faixa de utilização do equipamento / The study aimed to evaluate the radial profile and the uniformity of water distribution of sprinkler manufactured by the company NaanDanJain, model 427 1/2M and nozzle with 2.8 mm of internal diameter, operating at pressures of 150, 200, 300 and 400 kPa and five positions of the deflector (0, 20, 50, 80 and 100%). For the determination of the parameters rated, we used the method of the grid, and with the aid of computer application CATCH 3D, it was calculated overlapping layers of water with ten spacing. The results show that the deflector adjustment influences the radius of wetness, the distribution profile and the uniformity of water application and showed itself as an important mechanism, since it gave different behavior for the sprinkler, ensuring wide track usage of the equipment
87

Diferentes concentrações de ferro na água, seu efeito na cultura do girassol ornamental e no desempenho de gotejador /

Oliveira, Alessandra Conceição de, 1984. January 2010 (has links)
Resumo: O presente trabalho teve como objetivo avaliar a produtividade do girassol ornamental cultivar 'Sunflower F1 Sunbright Supreme' e o desempenho dos emissores gotejadores com diferentes concentrações de ferro na água de irrigação. O experimento foi conduzido no Departamento de Engenharia Rural, Faculdade de Ciências Agronômicas, pertencente à Universidade Estadual Paulista - UNESP, Campus de Botucatu, Estado de São Paulo, em duas fases: a I compreendido de 08 de Maio a 13 de Julho de 2009, e a II em 01 de Dezembro de 2009 a 10 de Maio de 2010. Na fase I o delineamento experimental foi inteiramente casualizado, fatorial 4 x 2 (4 teores de ferro e 2 emissores), com 4 repetições e 20 plantas por parcela, um vaso compostas por uma planta, constituindo um total de 160 vasos, onde testaram uma testemunha e três doses de ferro na água (zero; 0,5; 1,5; e 3,0 mg L -¹), e dois tipos de gotejadores um autocompensante e outro normal. Ao final do experimento, foram avaliados os seguintes parâmetros de desenvolvimento das plantas: A altura da parte aérea (cm), comprimento da haste (cm) e sistema radicular (cm), diâmetro de haste (mm), número de folha, área foliar (cm2), massa seca da parte aérea, do sistema radicular, das inflorescências e total (g), diâmetro de inflorescências: diâmetro do capítulo floral (mm), e diâmetro do disco (mm). Na fase II o delineamento experimental foi inteiramente casualizado, três doses de ferro na água (0,5; 1,5; e 3,0 mg L -¹), e dois tipos de gotejadores um autocompensante e outro normal (Netafim e Amanco) em 3 repetições e 20 emissores cada. As avaliações dos gotejadores foram: Vazão média (Q), Coeficiente de uniformidade de distribuição (CUD), Coeficiente de variação de fabricação (CV) e Coeficiente uniformidade de Christiansen (CUC). Os resultados foram submetidos à análise de variância pelo teste F. As médias foram comparadas...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this present work was to evaluate the yield of ornamental sunflower "Sunflower F1 Sunbright Supreme" cultivar and the performance of drippers with different iron concentrations on irrigation water. The experiment was carried out on Rural Engeneering Department, Agronomic Sciences College of Paulista State University - UNESP, Campus of Botucatu, São Paulo, with two steps. The step I was realized may 8th to July 13th 2009 and the second step on December 1st 2009 to May 10th 2010. The first step was design entirely at random, with factorial scheme 4 X2 (four iron levels and two drippers) with 4 repetitions, and 20 plants per treatment composed by one plant, totalizing 160 pots where a check treatment was tested and 3 doses of iron on water (zero; 0,5; 1,5; and 3,0 mg.L-1) and two types of drippers: self-compensating and normal. At the end of the experiment were evaluated the parameters for plants development: The height of air part (cm) length of the stem (cm) and root system (cm) diameter Shank (mm), number of leaf, leaf area (cm2), dry mass of air part, of the system root, of the inflorescences and total (g) inflorescences diameter: diameter of chapter floral (mm) and diameter of the disk (mm). In step II trial design was entirely at random, three doses of iron in water (0.5; 1.5; and 3.0 mg L-1), and two types of self-compensating dripper and another normal (Netafim and Amanco) with 3 repetitions and 20 drippers each. The evaluations of drippers were: average flow (Q), Coefficient of uniformity of distribution (CUD), coefficient of variation of manufacturing (CV) and coefficient of uniformity of Christiansen (CUC). The results were subjected to analysis of variance by f-test. Averages were compared by Tukey's test 5% probability for drippers and Regression to 5% probability for iron doses. Concluded that the production of ornamental sunflower solution with residual water... (Complete abstract click electronic access below) / Orientador: Raimundo Leite Cruz / Coorientador: Guilherme Augusto Biscaro / Banca: Antônio de Pádua Sousa / Banca: Tarlei Arriel Botrel / Mestre
88

Uniformidade de distribuição de água em irrigação localizada com sistema de aeração, decantação e filtragem /

Silva, Elcides Rodrigues da. January 2009 (has links)
Resumo: A pesquisa teve como objetivo avaliar o desempenho de um sistema de aeração, decantação e filtragem, quanto à prevenção de entupimento dos emissores e avaliar uniformidade de distribuição da água no sistema de irrigação por gotejamento na época de sua implantação e após um ano de utilização do sistema de prevenção. O trabalho foi realizado na Fazenda Estância Tropical, no município de Barretos - SP, no período de março de 2008 a fevereiro de 2009, realizando-se determinações físicas e químicas da água, ao longo do sistema de aeração, decantação e filtragem, que foi eficiente para a melhoria da qualidade de água, reduzindo os níveis de risco de entupimento de severo para médio e de médio para baixo. Todas as variáveis analisadas diferenciaram a qualidade da água entre os pontos de amostragem do sistema de tratamento, com exceção do Fe+2. Para sólidos em suspensão, turbidez, sólidos dissolvidos e ferro total, os valores reduziram-se pelo uso do sistema proposto, melhorando a qualidade da água. Após um ano de funcionamento do sistema de prevenção, os coeficientes utilizados para determinar a uniformidade de distribuição de água apresentaram valores acima de 80%, sendo classificados como excelente, bom e muito bom / Abstract: The research aimed to evaluate the performance of aeration, sedimentation and filtration system for the prevention of emitters clogging and evaluate the water distribution uniformity of one drip irrigation system at the time of its implementation and after a year using the prevention system. The research was conducted in the Estancia Tropical farm, in the municipality of Barretos - SP, Brazil, from March 2008 to February 2009, carrying out physical and chemical determinations of water along the aeration, sedimentation and filtration system, which was efficient for improving water quality by reducing levels of risk of clogging of severe to medium and medium to low. All variables differed water quality between the collection points of the treatment system with the exception of Fe+2. For suspended solids, turbidity, dissolved solids and total iron values were reduced by the use of the proposed system, improving water quality. After a year of prevention, the coefficients used to determine the uniformity of water distribution had values above 80%, being classified as excellent, good and very good / Orientador: José Renato Zanini / Coorientador: Jairo Osvaldo Cazetta / Banca: Luiz Carlos Pavani / Banca: Rubens Duarte Coelho / Mestre
89

Uniformidade de distribuição temporal e espacial do KCL na fertirrigação, em um sistema de irrigação por gotejamento /

Oliveira, Marcus Vinicius Araujo Mello de, 1976- January 2002 (has links)
Orientador: Roberto Lyra Villas Bôas / Banca: João Carlos Cury Saad / Banca: Tarlei Arriel Brotel / Resumo: As vantagens advindas do uso da fertirrigação para a agricultura brasileira esbarram na ausência de trabalhos que busquem trazer informações sobre muitos aspectos relacionados à técnica. O presente trabalho, conduzido na Faculdade de Ciências Agronômicas - UNESP, procura diminuir essa carência de conhecimento comparando três injetores de fertilizante em condições de campo, encontrando e indicando o menor tempo possível para injeção de fertilizantes em um sistema de irrigação por gotejamento. O experimento foi instalado na área de experimentação do Departamento de Engenharia Rural da referida faculdade, localizada no município de Botucatu - SP, ocupando uma área de 0,7 ha. O sistema de irrigação foi dimensionado buscando simular um setor de um pomar de citros, composto basicamente por um cabeçal de controle, uma linha principal, uma linha de derivação e seis linhas laterais com 200 m de comprimento cada. Os equipamentos utilizados para injeção de fertilizantes foram: um injetor venturi, uma bomba dosificadora elétrica e uma bomba dosificadora hidráulica proporcional. Como forma de estudar a distribuição espacial e temporal do íon potássio no sistema de irrigação, quatro tempos de injeção foram escolhidos: 10, 15, 20 e 25 minutos; sendo recolhidas amostras de solução em diferentes momentos durante e após a injeção do produto. As amostras coletadas tiveram seu teor de K determinado, via fotometria de chama, com a finalidade de inferir-se a uniformidade de distribuição do íon nos diferentes tratamentos. Concluiu-se que quanto menor a distância percorrida pelo fertilizante e mais longo o tempo de injeção, maior é a uniformidade de distribuição. Os injetores utilizados não apresentaram diferença estatística quanto uniformidade de aplicação de fertilizantes...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The advantages of fertigation use for Brazilian agriculture encounter a lack of works with information about this technique. The objective of this was to supply the lack of knowledge comparing three fertilizers injection in field conditions. The results indicated the smallest possible time for injection of fertilizers in a trickle irrigation system. The experiment was carried out in the area of experimentation of the Department of Rural Engineering of Faculty of Agronomic Sciences - UNESP, in Botucatu - SP, with an area of 0,7 ha. The irrigation system was designed searching into simulate a citrus orchard, composed basically for head control, a main line, a derivation line and six lateral lines with 200 m of length each. The equipment used for injection of fertilizers were: a venturi injector, an electric pump and a proportional hydraulic pump. Four times, 10, 15, 20 and 25 minutes, of injection were chosen to study the space and temporary distribution of the ion potassium in the irrigation system,:. The solution samples were picked up in different moments during and after the injection of the product. The contents of K were measured in the samples, using flame fotometric, with the purpose of determining the uniformity of distribution of ion in different treatments. The results showed that as much as shorter the distance and as much as longer the injection time, better is the uniformity of distribution. There was no difference in uniformity of distribution of potassium among the used injectors...(Complete abstract, click electronic access below) / Mestre
90

Aspectos qualitativos e quantitativos em pulverização na cultura do amendoim e Brachiaria plantaginea (Link) Hitch /

Rodrigues, Andréia Cristina Peres, 1978- January 2010 (has links)
Orientador: Dagoberto Martins / Banca: Carlos Gilberto Raetano / Banca: Maurício Dutra Zanotto / Banca: Marcelo da Costa Ferreira / Banca: Fernando Tadeu de Carvalho / Resumo: Objetivou-se avaliar a quantidade e qualidade da deposição da calda de pulverização em duas cultivares de amendoim (Aracahis hypogaea L.) e na planta daninha Brachiaria plantaginea (Link) Hitch., presente na linha e entrelinhas de semeadura da cultura, além da deposição no solo, em aplicações de pós-emergência. O estudo foi realizado a campo com duas cultivares de amendoim ('IAC Tatu-ST' e 'Runner IAC 886'), sendo as aplicações dos tratamentos realizadas nos estádios vegetativo (V1) e reprodutivo (R2). Foi utilizado como marcador o corante Azul Brilhante FDC -1 na concentração de 500 ppm. Os tratamentos foram constituídos por sete pontas de pulverização: XR 110015 VS (150 L ha-1), XR 11002 VS (200 L ha-1), TX-VK 6 (150L ha-1), TX-VK 8 (200 L ha-1), AI 110015 VS (150 L ha-1), AI11002 VS (200 L ha-1) e TJ60 11002 VS (150 e 200 L ha-1). Utilizou-se o delineamento em blocos ao acaso, com 4 repetições. Os dados dos resultados quantitativos de deposição foram analisados nos seguintes esquemas em fatorial: para os depósitos em plantas de amendoim foi utilizado o esquema 8 x 2 (8 situações de pulverização x 2 estádio de desenvolvimento da cultura); para as plantas daninhas presentes na linha e na entrelinha da cultura do amendoim, o esquema foi 8 x 2 [8 situações de pulverização x 2 posições (linha e entrelinha)]; para as estimativas de deposição no solo, o esquema foi 8 x 2 [8 situações de pulverização x 2 posições (linha e entrelinha)]. Foram amostradas 25 plantas por repetição em cada parcela, tanto para as plantas de amendoim quanto para as plantas daninhas presentes na linha e na entrelinha da cultura. Após a aplicação, as plantas foram imediatamente coletadas, e em seguida foram lavadas em 100 mL de água destilada para posterior quantificação do marcador em espectrofotômetro. Para as análises qualitativas, cada planta selecionada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the quantity and quality of the spray deposition in two peanut cultivars (Aracahis hypogaea L.) and weed Brachiaria plantaginea (Link) Hitch., current in the crop row and spacing row, beyond the deposition in soil, in applications of post-emergency. The study was conducted in the field with two peanut cultivars ('IAC Tatu-ST' e 'Runner IAC 886'), and the applications of treatments performed in the vegetative stage (V1) and reproductive (R2). It was used the Brilliant Blue FDC - 1 as tracer in water solution, at 500 ppm. The treatments consisted of seven spray nozzle XR 110015 VS (150 L ha-1), XR 11002 VS (200 L ha-1), TX-VK 6 (150L ha-1), TX-VK 8 (200 L ha-1), AI 110015 VS (150 L ha-1), AI11002 VS (200 L ha-1) e TJ60 11002 VS (150 e 200 L ha1). It was used a randomized blocks design, with four replications. Being that, the results of the quantitative data of deposition had been analyzed in following factorial schemes: for the deposits in peanut plants was used 8 x 2 factorial scheme (8 situations spray x stage of development of culture), for the Brachiaria plantaginea plants was used 8 x 2 factorial scheme [8 situations spray x 2 positions (row and spacing row)]; for the soil deposition estimates, the factorial scheme was 8 x 2 [8 situations spray x 2 positions (row and spacing row)]. Were sampled 25 plants for replication in each plot, as much for the peanut plants as current weeds in crop row and spacing row. After application, the plants were immediately collected, and after they had been washed in 100 mL of distilled water for tracer remover. The tracer quantification was made in spectrophotometer. For the quantitative analysis, each random selected plant inside of boom application stripe bar was considered a replication, representing a total of 100 replications. The obtained data had been adjusted a regression curve for Gompertz... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0544 seconds