• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design of slender steel members : A comparison between the reduced stress method and the effective width method

Skoglund, Oskar, Samvin, Daniel January 2016 (has links)
As of now, the most common way in Sweden, to address the issue of local buckling of steelstructures is through the procedure called the effective width method. A less commonprocedure for dealing with local buckling is the reduced stress method. The benefit of thelatter method is that, when combined with finite element analysis, results in a less tediousdesign process. However, this method is often labelled as a method that results in anoverconservative design. Therefore, the purpose of this report is to compare and evaluate thereduced stress method against the effective width method and nonlinear finite elementmethod. The nonlinear FE-analyses are performed with intention of simulating the realbehaviour of the structure and serve as a reference for the other two methods. The comparisonis conducted through a series of analyses, on different steel members with various loadconfigurations and slenderness in order to include the most common cases in the constructionindustry. This report resulted in recommendations for when the reduced stress method couldbe a relevant design procedure, with emphasis on providing reliable and accurate resultscompared to FE-analyses. Furthermore, the report resulted in proposed further studies, bothregarding the improvement of the reduced stress method and other structural elements thatshould be studied. The result from the report indicates that the reduced stress method can beused when the effect of patch loading is small. Furthermore, it is recommended to obtain thecritical stresses from a linear finite element analysis rather than from hand calculations, as tonot end up with over-conservative results. / I Sverige behandlas problemet med lokal buckling av stålkonstruktioner vanligtvis med hjälpav den effektiva bredd metoden, vilket är en dimensionergsmetod som återfinns i Eurocode.En ytterligare dimensionerings metod för lokal buckling som presenteras i Eurocode är denreducerade spänningsmetoden. Den senare nämnda metoden är fördelaktig då den kombinerasmed linjära finita element analyser, vilket resulterar i en mindre tidskrävandedimensioneringsprocess. Dock är metoden känd för att ofta resultera i överdimensioneradekonstruktioner, vilket bidragit till att mindre antal konstruktörer använder sig av denna metod.Syftet med denna rapport blir därmed att jämföra och utvärdera den reduceradespänningsmetoden gentemot den effektiva bredd metoden och olinjär finita element metoden.De olinjära finita element analyserna genomfördes med syfte att simulera det verkligabeteendet och för att sedan jämföra dessa resultat med de två andra metoderna. Analyser harutförts på flera stålbalkar med olika lastkombinationer och slankhet för att inkludera devanligaste fallen inom byggindustrin. Dessutom har det tagits fram några rekommendationerför användningen av metoderna och dessa är presenterade med avseende på de erhållnaresultaten. Rekommendationer för den reducerade spänningsmetoden har presenterats ochytterligare studier gällande dessa metoder och andra konstruktionselement har föreslagits. Deslutsatser som kunde dras är att den reducerade spänningsmetoden kan användas förkonstruktioner som inte påverkas i allt för stor grad av intryckning. För att ge tillförliterligaresultat så rekommenderas att kritiska spänningar erhålles från linjära finita element analyser.

Page generated in 0.0982 seconds