[pt] APRIMORAMENTO DA GERAÇÃO UNIDIRECIONAL DE ONDAS ULTRASSÔNICAS DO TIPO SH COM TRANSDUTORES ACÚSTICOS ELETROMAGNÉTICOS DO TIPO ÍMÃS PERMANENTES PERIÓDICOS COM SEPARAÇÃO LATERAL E MÚLTIPLAS FILEIRAS DE ÍMÃS / [en] ENHANCEMENT OF UNIDIRECTIONAL GENERATION OF SH ULTRASONIC WAVES WITH SIDE-SHIFTED PERIODIC PERMANENT MAGNET ELECTROMAGNETIC ACOUSTIC TRANSDUCERS AND MULTIPLE ROWS OF MAGNETSLUCAS MONTEIRO MARTINHO 25 October 2022 (has links)
[pt] Ondas ultrassônicas do tipo SH (do inglês, shear horizontal), ou de cisalhamento
horizontal são úteis no campo de ensaios não-destrutivos. Essas podem
ser geradas, em meios metálicos, por transdutores acústicos eletromagnéticos
(EMAT) que utilizam um arranjo de ímãs permanentes periódicos (PPM),
chamados de EMATs PPM. Tais dispositivos em sua forma convencional, entretanto,
geram ondas ultrassônicas bidirecionalmente, ou seja, para frente
e para trás. Essa característica é geralmente indesejada. Recentemente, foi
proposto um EMAT tipo PPM duplo com separação lateral que gera ondas
nominalmente em uma única direção. Entretanto, seu diagrama de radiação
revela lóbulos traseiros laterais. Esta dissertação tem como objetivo aprimorar
o supracitado projeto através de seus parâmetros de construção, mais especificamente,
o número de fileiras de ímãs permanentes do arranjo PPM e a separação
lateral entre as mesmas. Foi desenvolvido um modelo analítico, baseado em
linhas de fontes lineares, que considera a projeção de cada espira como uma
fonte harmônica independente, para cálculo do campo ultrassônico gerado por
EMATs PPM, tanto os do tipo PPM duplo, quanto o convencional. Com isso, foi
possível obter o digrama de radiação teórico dos dispositivos, de forma a analisar
como os seus parâmetros de construção interferem em sua unidirecionalidade.
Utilizou-se três tecnologias distintas de bobinas, a saber, bobinas fabricadas
manualmente, bobinas fabricadas a partir de placas de circuito impresso (PCB)
flexível de poliamida e PCB flexível de poliéster. Os arranjos PPM duplos
foram colocados sobre moldes impressos em impressora 3D. Realizou-se testes
experimentais em uma placa de alumínio 1.5 mm de espessura, com EMAT
PPM comercial utilizado como receptor, em diversos ângulos, com o objetivo
de calcular o diagrama de radiação experimental do EMAT PPM duplo. Ao
todo foram montadas 44 unidades quando combinadas todas as tecnologias de
fabricação de bobina, com separação lateral de 1 mm a 4 mm e 1 a 4 de fileiras
de ímãs. Resultados experimentais e teóricos mostraram boa concordância. Foi
observado que tanto aumentar o número de fileiras de ímãs, quanto diminuir
a sua separação lateral reduzem a intensidade dos lóbulos traseiros laterais.
Resultados experimentais mostraram que, com a configuração de 4 fileiras de ímãs, separados lateralmente por 1 mm e bobinas feitas a partir de PCB de
poliamida, a intensidade dos lóbulos traseiros laterais foi reduzida em 8.6 dB,
em relação à configuração original do PPM EMAT duplo . Sobre as tecnologias
de bobina, pode-se concluir que o uso de PCBs flexíveis tornou possível obter
menores separações laterais entre as fileiras de ímãs e simplificar o processo
de construção do EMAT PPM duplo, com destaque para a bobina feita com
PCB flexível de poliamida, que apresentou baixo erro médio entre medidas
experimentais e simuladas, apresentando também o mais fácil processo de
fabricação entre os três tipos de bobinas avaliados. / [en] Shear horizontal (SH) ultrasonic waves are useful in the non-destructive
evaluation field. They can be generated, in metallic media, by electromagnetic
acoustic transducers (EMAT) that use an array of periodic permanent magnets
(PPM). PPM EMATs, in their conventional form, generate forward and
backward traveling SH waves. This feature is generally undesired. Recently,
a side-shifted dual-PPM EMAT has been proposed. This device generates
waves predominantly in a single direction. However, its radiation pattern
reveals backward side lobes. This thesis aims to improve the aforementioned
design through its construction parameters, more specifically, the number of
rows of magnets in the PPM array and the lateral separation between them.
An analytical model, based on the line source method, which considers the
wires projections as independent wave sources, was developed to calculate the
ultrasonic field generated by PPM EMATs, either for the conventional one
or the dual-PPM EMAT. Exploiting the developed model, it was possible
to compute the theoretical radiation pattern of the device in order to better
analyse how its construction parameters affect its unidirectionality. Three
different coil technologies were used, namely hand-wound coils and coils made
with flexible printed circuit boards (PCBs), either of polyamide or polyester
material. The magnet arrays were mounted on 3D-printed molds to ensure
their positioning. Experimental tests were carried out where the fabricated
device was placed onto a 1.5 mm-thick aluminum plate, and a commercial PPM
EMAT was used as a receiver, at different reception angles, in order to calculate
the radiation pattern of the dual-PPM EMAT. Overall, 44 units, combining
all coil technologies, were manufactured with lateral separation from 1 mm
to 4 mm and 1 to 4 rows of magnets per PPM. Experiments and theoretical
results presented good agreement. It was observed that either increasing the
number of rows of magnets or decreasing their lateral separation reduced the
intensity of the backward side lobes. When using the configuration of 4 rows of
magnets and 1 mm side shift, fabricated with polyamide PCBs, results revealed
that the intensity of the backward side lobes was reduced by 8.6 dB, when
compared with the original configuration. Regarding the coil technologies, it can be concluded that the use of flexible PCBs allowed one to obtain shorter lateral
separations between rows of magnets and simplified the fabrication process
of the dual-EMAT. Mainly, the poliamide-based flexible PCB coil presented
low average error between experimental and simulated measurements and the
easiest fabrication process among all three coil technologies tested.
|
12 |
[pt] ESTIMAÇÃO DA TENSÃO MECÂNICA USANDO ONDAS ULTRASSÔNICAS GUIADAS E MACHINE LEARNING / [en] MECHANICAL STRESS ESTIMATION USING GUIDED ULTRASONIC WAVES AND MACHINE LEARNINGCHRISTIAN DEYVI VILLARES HOLGUIN 11 July 2022 (has links)
[pt] Devido ao efeito acoustoelástico, as Ondas guiadas ultrassônicas (UGWs)
têm sido usadas para estimar a tensão mecânica com baixo custo de forma não
destrutiva. O Aprendizado de maquina (ML) tem sido aplicado para mapear
formas complexas de ondas para estimar a tensão mecânica, embora aspectos
importantes como precisão e consumo computacional não tenham sido explorados. Na literatura também não há muito trabalho sobre o uso do aprendizado
não supervisionado para a rotulagem automática de amostras com diferentes
estados de tensão. Portanto, esta tese apresenta duas abordagens: i) a abordagem supervisionada propõe uma metodologia de modelagem de dados que
otimiza a precisão e a implementação computacional, para a estimação da tensão baseada em UGWs em tempo real e ii) a abordagem não supervisionada
compara estruturas não supervisionadas para rotular um pequeno conjunto de
dados de acordo com o estado de tensão. Para o primeiro, foram avaliados
modelos de aprendizagem superficial e profunda com redução de dimensionalidade, estes modelos são criados e testados usando um procedimento de
hold-out Monte-Carlo para avaliar sua robustez. Os resultados mostram que,
utilizando modelos superficiais e Análise de componentes principais (PCA),
foi obtida uma melhoria de precisão e no consumo de hardware em comparação com o estado da arte com modelos de redes neurais profundas. Para o
segundo, métodos de redução de dimensionalidade: PCA e t-distributed stochastic neighbor embedding (t-SNE), são usados para extrair características
de sinais UGWs. As características são usadas para agrupar as amostras em
estados de baixa, média e alta tensão. Uma análise qualitativa e quantitativa
dos resultados foi realizada, considerando a análise de métricas para agrupamento, o PCA realizou o melhor agrupamento, qualitativamente, mostrando
menos sobreposição en grupos do que t-SNE. As duas abordagens utilizadas
nesta tese, conseguiram extrair características significativas que ajudam tanto
na estimativa quanto tanto na rotulagem de dados, contribuindo para a criação
de modelos de ML mais eficientes e no problema de interpretação de UGWs. / [en] Due to the acoustoelastic effect, Ultrasonic Guided Waves (UGWs)
have been used to estimate mechanical stress in a non-expensive and nondestructively fashion. Machine Learning (ML) has been applied to map complex waveforms to stress estimates, though important aspects, such as accuracy
and hardware consumption, have not been explored. Previously in the literature, there are also not many works on the use of unsupervised learning for
automatic labeling of samples with different stress states. Therefore, this thesis
presents two approaches, (i) the supervised approach aims to propose a data
modeling methodology that optimizes accuracy and computational implementation, for real-time ultrasonic based stress estimation and (ii) the unsupervised approach aims at comparing unsupervised frameworks to label a small
dataset according to the stress state. For the former, shallow and deep learning
models with dimensionality reduction were evaluated, these models are created
and tested using a Monte-Carlo holdout procedure to evaluate their robustness
under different stress conditions. The results show that, using shallow models and Principal Component Analysis (PCA), an accuracy improvement and
hardware consumption as compared to the state of the art reported with deep
neural network models were obtained. For the latter, dimensionality reduction
methods: PCA and t-distributed stochastic neighbor embedding (t-SNE), are
used to extract features from UGWs signals with different stress levels. The
features are used to group the samples into low, medium and high stress states.
A qualitative and quantitative analysis of the results was performed. Considering the analysis of metrics for clustering, PCA performed the best clustering,
qualitatively, showing less overlapping of clusters than t-SNE. The two approaches used in this thesis, managed to extract meaningful features which
helped in both estimation and stress labeling, contributing to the creation of
more efficient ML models and in the problem of interpreting UGWs.
|