• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Composition Effects on Sheen and Spread Rate of an Interior Flat, One Coat Latex Paint Formulation

Christensen, Dana James, II 01 August 2015 (has links)
Interior flat, white latex paint is a common coating applied to walls around the world. Development of a coating with one coat hide capability is a pinnacle achievement for paint formulators as it has the potential to save consumers both time and money. One coat paints already exist on the market, but they are limited in color, coverage, and often have many disclaimers. Work done was part of a project initiated by ChemoursTM Titanium Technologies. The goal of the project presented in this article was to create an interior flat, white latex paint that yields a spread rate of greater than 400 ft2/gal., which is advertised by many below critical pigment volume concentration (CPVC) commercial paints. In order to achieve this goal, an above CPVC paint with a high TiO2 content was created and continuously improved. Improvement of the formulation involved numerous experimental variations including adjustments to the hydroxyethylcellulose (HEC) molecular weight, dispersant chemistry, latex chemistry, TiO2 concentration, extender package, and rheology modifier type. The sheen value, relative light scattering, and spread rate were the main measurements conducted in order to judge formulation improvement. Complications with the spread rate procedure forced its adaptation in order to collect less variable data with the high density, shear thinning formulations. It was found that shorter opacity charts yielded more precise spread rate data than the longer opacity charts. An attempt at correlating rheology with sheen development resulted in the conclusion that the pigment and extender particle package is the greatest driving factor behind sheen reduction. The rheology modifier type and dispersant chemistry did not affect the flatness of the paint nearly as much. A Keyence VR-3000 series One-Shot 3D Measuring Macroscope was used to show that surface roughness does not directly correlate to the sheen value when a number of flat paints with different sheens were analyzed. This project is an ongoing effort and the information contained in this document will substantially help future development.
2

Mateřská školka / Kinderschule

Ingr, Jakub January 2020 (has links)
The aim of the diploma thesis is to elaborate the project documentation of kinderschule in the city Bucovice. The house is as a detached house in a newly-built area. The object is double-storeyed and without basement. It has rectangular size and is covered with a flat one coat roof. On the first floor there is one nursery department for eighteen children and technical facilities, on the second floor there is also one nursery department for eighteen children, a multipurpose hall and the head office. The house is build from brick with a contact thermal insulation system. Part of the project documentation is also a basic assessment of the building in terms of building physics.
3

Bytový dům - Brno / Apartment building - Brno

Zukal, Zdeněk January 2016 (has links)
The subject of the diploma thesis is to elaborate the design documentation of an apartment house with restaurant. The building is designed in the village of Lipůvka, South-Moravian region, on plot No.: 544/1 and 545/1 – cadastral region Lipůvka. The bulit-up area is 443,3 m2. There are four floors. There is restaurant, one housing unit (for persons with reduced mobility) and utility room in first above-ground floor. Second, third and fourth above-ground floor is for housing. Each of these three floors has three apartments – two apartments 3+k, one apartment 3+1. Entrance to every apartment is from main staircase. The building is based on the foundation walls of concrete C20/25, all vertical walls are from Porotherm System. Celings are composed of ceramic-conrete beams POT, ceramic insertion Miako and concrete. The staircase is monolithic reinforced concrete. The building is without basement, roofed by a warm flat roof.

Page generated in 0.0539 seconds