• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Calibration Free Estimation of the Point of Gaze and Objective Measurement of Ocular Alignment in Adults and Infants

Model, Dmitri 10 January 2012 (has links)
Two novel personal calibration procedures that do not require active user participation are presented. These procedures, in conjunction with a state-of-the-art remote eye-gaze tracking (REGT) technology, allow estimation of the angle between the optical and visual axes (angle kappa) automatically without explicit/active user involvement. The first algorithm for the binocular estimation of angle kappa (BEAK) is based on the assumption that at each time instant both eyes look at the same point on a surface with a known geometry (e.g., a computer monitor). The sensitivity of the BEAK procedure to the geometry of the observation surface and to the noise in the estimates of the optical axis is studied both analytically and in computer simulations. Experimental results with 4 adult subjects suggest that with the current REGT technology angle kappa can be estimated with an RMS error of 0.5°. The second personal calibration algorithm (‘calibrate and validate’, CaVa) adopts a probabilistic approach to the estimation of angle kappa in infants. Even though the presentation of visual stimuli at known positions is part of the procedure, the CaVa algorithm does not require/assume continuous fixation on the presented targets. If an infant attends to roughly half of the presented targets, angle kappa can be estimated accurately and with high confidence. In experiments with five babies, the average difference between repeated measurements of angle kappa was 0.04 ± 0.31°. The second part of the thesis describes two methods for automated measurement of eye misalignment in adults and infants. These methods are based on the user-calibration-free (UCF) technology presented in the first part of the thesis. The first method is based on the clinical Hirschberg test. It is shown that the UCF-REGT technology can improve significantly the accuracy of the Hirschberg test by enabling the estimation of subject-specific parameters (the Hirschberg ratio and angle kappa) in infants. The maximum error in the estimation of the horizontal and vertical components of eye misalignment in five orthotropic infants was shown to be less than 1°, which is significantly better than the accuracy of a standard clinical Hirschberg test. Finally, a novel Eye-Tracker Based Test (ETBT) for the estimation of the maximum (manifest + latent) angle of deviation is presented. ETBT is based on the UCF-REGT system. ETBT allows free head movements and does not require continuous fixation on specific targets. Experiments with 22 adult subjects demonstrated a good agreement of 0.7 ± 1.7° between ETBT and the gold-standard clinical procedure—the altenate prism and cover test. A pilot study with 5 orthotropic infants and one infant with strabismus demonstrated that the ETBT can be used in infants.
2

A Calibration Free Estimation of the Point of Gaze and Objective Measurement of Ocular Alignment in Adults and Infants

Model, Dmitri 10 January 2012 (has links)
Two novel personal calibration procedures that do not require active user participation are presented. These procedures, in conjunction with a state-of-the-art remote eye-gaze tracking (REGT) technology, allow estimation of the angle between the optical and visual axes (angle kappa) automatically without explicit/active user involvement. The first algorithm for the binocular estimation of angle kappa (BEAK) is based on the assumption that at each time instant both eyes look at the same point on a surface with a known geometry (e.g., a computer monitor). The sensitivity of the BEAK procedure to the geometry of the observation surface and to the noise in the estimates of the optical axis is studied both analytically and in computer simulations. Experimental results with 4 adult subjects suggest that with the current REGT technology angle kappa can be estimated with an RMS error of 0.5°. The second personal calibration algorithm (‘calibrate and validate’, CaVa) adopts a probabilistic approach to the estimation of angle kappa in infants. Even though the presentation of visual stimuli at known positions is part of the procedure, the CaVa algorithm does not require/assume continuous fixation on the presented targets. If an infant attends to roughly half of the presented targets, angle kappa can be estimated accurately and with high confidence. In experiments with five babies, the average difference between repeated measurements of angle kappa was 0.04 ± 0.31°. The second part of the thesis describes two methods for automated measurement of eye misalignment in adults and infants. These methods are based on the user-calibration-free (UCF) technology presented in the first part of the thesis. The first method is based on the clinical Hirschberg test. It is shown that the UCF-REGT technology can improve significantly the accuracy of the Hirschberg test by enabling the estimation of subject-specific parameters (the Hirschberg ratio and angle kappa) in infants. The maximum error in the estimation of the horizontal and vertical components of eye misalignment in five orthotropic infants was shown to be less than 1°, which is significantly better than the accuracy of a standard clinical Hirschberg test. Finally, a novel Eye-Tracker Based Test (ETBT) for the estimation of the maximum (manifest + latent) angle of deviation is presented. ETBT is based on the UCF-REGT system. ETBT allows free head movements and does not require continuous fixation on specific targets. Experiments with 22 adult subjects demonstrated a good agreement of 0.7 ± 1.7° between ETBT and the gold-standard clinical procedure—the altenate prism and cover test. A pilot study with 5 orthotropic infants and one infant with strabismus demonstrated that the ETBT can be used in infants.
3

Applications Of Linear And Nonlinear Optical Effects In Liquid Crystals

Sarkissian, Hakob 01 January 2006 (has links)
Liquid crystals have been a major subject of research for the past decades. Aside from the variety of structures they can form, they exhibit a vast range of optical phenomena. Many of these phenomena found applications in technology and became an essential part of it. In this dissertation thesis we continue the line to propose a number of new applications of optical effects in liquid crystals and develop their theoretical framework. One such application is the possibility of beam combining using Orientational Stimulated Scattering in a nematic liquid crystal cell. Our numerical study of the OSS process shows that normally this possibility does not exist. However, we found that if a number of special conditions is satisfied efficient beam combining with OSS can be done. These conditions require a combination of special geometric arrangement of incident beams, their profiles, nematic material, and more. When these conditions are fulfilled, power of the beamlets can be coherently combined into a single beam, with high conversion efficiency while the shape and wave-front of the output beam are still of good quality. We also studied the dynamics of the OSS process itself and observed (in a numerical model) a number of notorious instabilities caused by effects of back-conversion iv process. Additionally, there was found a numerical solitary-wave solution associated with this back-conversion process. As a liquid crystal display application, we consider a nematic liquid crystal layer with the anisotropy axis modulated at a fixed rate in the transverse direction with respect to light propagation direction. If the layer locally constitutes a half-wave plate, then the thinscreen approximation predicts 100% -efficient diffraction of normal incident wave. If this diffracted light is blocked by an aperture only transmitting the zero-th order, the cell is in dark state. If now the periodic structure is washed out by applying voltage across the cell and light passes through the cell undiffracted, the light will pass through the aperture as well and the cell will be in its bright state. Such properties of this periodically aligned nematic layer suggest it as a candidate element in projection display cells. We studied the possibility to implement such layer through anchoring at both surfaces of the cell. It was found that each cell has a thickness threshold for which the periodic structure can exist. The anchored periodic structure cannot exist if thickness of the cell exceeds this threshold. For the case when the periodic structure exists, we found the structure distortion in comparison with the preferable ideal sinusoidal profile. To complete description of the electromechanical properties of the periodic cell, we studied its behavior at Freedericksz transition. Optical performance was successfully described with the coupled-mode theory. While influence of director distortion is shown to be negligibly small, the walk-off effects appear to be larger. In summary, there are good prospects for use of this periodically v aligned cell as a pixel in projection displays but experimental study and optimization need to be performed. In the next part we discuss another modulated liquid crystal structure in which the director periodically swings in the direction of light propagation. The main characteristic of such structure is the presence of bandgap. Cholesteric liquid crystals are known to possess bandgap for one of two circular polarizations of light. However, unlike the cholesterics the bandgap of the proposed structure is independent of polarization of normally incident light. This means that no preparation of light is needed in order for the structure to work in, for example, liquid crystal displays. The polarization universality comes at the cost of bandgap size, whose maximum possible value ∆ωPTN compared to that of cholesterics ∆ωCh is approximately twice smaller: ∆ωPTN ≈ 0.58∆ωCh if modulation profile is sinusoidal, and ∆ωPTN ≈ 0.64∆ωCh if it is rectangular. This structure has not yet been experimentally demonstrated, and we discuss possible ways to make it.

Page generated in 0.0774 seconds