• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Alterações dimensionais dos arcos dentários decorrentes do tratamento com o aparelho Pendulum associado ao fixo: avaliação longitudinal / Maxillary molar distalization by Pendulum appliance: a prospective study in digital 3d models

Alessio Junior, Luiz Eduardo 19 September 2012 (has links)
Objetivo: avaliar, por meio de modelos digitalizados, o comportamento transversal do arco dentário superior de pacientes submetidos ao tratamento da má oclusão de Classe II, corrigida com o aparelho Pendulum, seguido de aparelhagem ortodôntica fixa nos períodos inicial, pós-distalização, pós-tratamento e longo tempo póstratamento. Material e Métodos: Oitenta modelos de 20 pacientes (14 do gênero feminino e 6 do masculino), foram digitalizados no aparelho REXCAN DS2. A média da idade, ao início do tratamento (T1), foi de 14,02 ± 1,62 anos, pós-distalização (T2), foi de 14,54 ± 1,61, ao final do tratamento (T3), 18,38 ± 1,84 anos, e no póstratamento (T4), 22,94 ± 1,34 anos. As distâncias intercaninos, interpré-molares e intermolares foram realizadas no programa Geomagic Studio 5®. A análise de variância dependente para medidas repetidas (ANOVA) foi utilizada para avaliar as alterações entre os períodos. Resultados: não ocorreram alterações transversais na distância intercaninos nas fases estudadas. Os pré-molares demostram um aumento na fase de aparelhagem fixa (T2-T3), para os segundos pré-molares a diferença foi observada entre o período inicial (T1) e os período pós-tratamento (T3). A distância dos primeiros molares alterou durante a fase de distalização (T1-T2), retornando aos valores iniciais durante a fase pós-tratamento (T3). Para os segundos molares, as alterações ocorreram durante o período de distalização (T2) e pós-tratamento (T3). Não ocorreram alterações na fase de longo tempo pós-tratamento. Conclusão: Os resultados permitem concluir que, durante o tratamento com o aparelho Pendulum seguido pelo fixo, ocorrem alterações transversais no arco superior, no entanto, estas alterações permanecem estáveis cinco anos pós-tratamento. / Objective: The aim of this longitudinal study was to asses transversal changes in maxillary dental arch in twenty patients between 14 and 18 years old, treated first by Pendulum and followed by fixed appliances. Material and Methods: Dental measurements in eighty digital 3D models were obtained in pretreatment, postdistalization, post-treatment and long-term post-treatment phases. The statistical analysis was performed by ANOVA test. Results: Premolars and molars distances increased during the fixed appliance treatment (post-distalization and post-treatment phase) and in the long post-treatment phase there were no significant changes. No significant difference was observed in canines transversal distance. Conclusion: It was concluded that Pendulum followed by the fixed appliances, changes dental arch width during the full treatment and it was stable in the long-term post-treatment.
12

Estudo comparativo da ação biomecânica de alças ortodônticas confeccionadas em fios retangulares\" / Comparative study of biomechanical action of orthodontic loops made with rectangular wires

Cecilio, Eliane 10 November 2006 (has links)
No tratamento das maloclusões muitas vezes se impõe a necessidade de extrações dentárias para cumprir as metas do tratamento ortodôntico em busca da oclusão normal. Um dos recursos para o fechamento de espaços após exodontias é a utilização de arcos de retração com alças. Atualmente existe, no mercado, uma grande disponibilidade de arcos pré-fabricados, fornecidos por diversos fabricantes, que apresentam variações na forma e número de alças, espessura dos fios e ligas metálicas diferentes. O conhecimento das propriedades mecânicas e das forças liberadas por estes arcos é de extrema importância para que se obtenha uma resposta biológica adequada durante a movimentação dentária. O presente estudo procurou avaliar, experimentalmente, as forças liberadas por alguns tipos mais utilizados de arcos com alças produzidos com fios de secção retangular com variações de geometria (espessura, número e forma das alças), liga metálica e fabricante, impondo-lhes diferentes ativações. Buscou-se ainda determinar a quantidade de ativação onde ocorre o limite de proporcionalidade e, finalmente, fazer comparações entre os arcos com o intuito de fornecer ao ortodontista subsídios para a escolha do arco adequado. Para tal foram utilizados 19 tipos diferentes de arcos submetidos a testes de tração. Foram registradas as forças continuamente até uma deformação das alças de 4 mm. As comparações foram realizadas por meio de testes estatísticos isolando-se apenas uma característica de variação permitindo uma melhor compreensão do fator preponderante na alteração da força. Os resultados revelaram variações importantes nas forças a cada 0,5 mm de ativação, sendo de forma geral, ativações de 0,5 e 1,0 mm as que liberam forças mais adequadas. Os limites de proporcionalidade ocorreram na sua maioria acima de 1,5 mm de ativação até 2,5 mm, podendo em arcos mais flexíveis ocorrer acima de 4,0 mm. As comparações estatísticas demonstraram diferenças significativas entre todos os grupos avaliados, revelando que todas as variações (geometria, espessura, material e fabricante) exercem influência sobre a força gerada, sendo que a liga metálica parece ser preponderante. / In malocclusion treatments, dental extractions become necessary, in some cases, in order to achieve orthodontic goals of normal occlusion. One of the devices employed to close spaces after dental extraction is the use of retraction arches with loops. Nowadays, there is a wide range of pre-manufactured arches in the market, which present variations in shape, number of loops, thickness of the wire and metallic alloys. It is extremely important to understand mechanical properties as well as the forces delivered by these arches in order to achieve proper biological response during tooth movement. The present study tried to evaluate, experimentally, forces delivered by some of the most frequently employed arches made of rectangular wires with different geometrical characteristics (thickness, number and shape of loops), metallic alloys and made by different manufacturers, when submitted to different levels of activation. It was tried to determine the activation level at proportional limit and compare these values for different arches, in order to provide the orthodontists with accurate data which may help them to choose the proper arches. Nineteen different types of arches were submitted to tension tests. Forces were continuously measured up to 4 mm level of loop deformation. Statistical tests were employed to make comparisons, with only one type of variation for each test, which allowed a better comprehension of the main factor in force change. Results revealed important variations in forces at 0.5 mm intervals, and generally, 0.5 mm and 1.0 mm levels of activation delivered the most proper forces. Proportional limit occurred, mostly, over 1.5 mm and up to 2.5 mm levels of activation, except for more flexible arches, when it occurred above 4.0 mm. Statistical comparisons showed significant differences between all groups studied, demonstrating that all variations (geometry, thickness, material and manufacturer) can influence the delivered force. In spite of this, metallic alloys seemed to be the most important factor determining force deliverance variation.
13

Solução de tecnologia para planejamento e tratamento ortodôntico de dentes inclusos / Technology solution for treatment and planning of teeth included orthodontic treatment

Lima, Jefferson Felipe Silva de 22 December 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2018-05-24T12:40:53Z No. of bitstreams: 1 PDF - Jefferson Felipe Silva de Lima.pdf: 26931863 bytes, checksum: b52e9a3ab1c58df593cae907b9fc936d (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2018-06-05T11:33:36Z (GMT) No. of bitstreams: 1 PDF - Jefferson Felipe Silva de Lima.pdf: 26931863 bytes, checksum: b52e9a3ab1c58df593cae907b9fc936d (MD5) / Made available in DSpace on 2018-06-05T11:33:36Z (GMT). No. of bitstreams: 1 PDF - Jefferson Felipe Silva de Lima.pdf: 26931863 bytes, checksum: b52e9a3ab1c58df593cae907b9fc936d (MD5) Previous issue date: 2016-12-22 / The Additive Manufacturing (MA), actually is used aiming the production of small proto- types, until a recent application in the field of dentistry, intended for the planning, simulation, testing and surgeries auditions and other dental procedures. Some orthodontic surgeries are endowed with levels of difficulty and require dexterity of the highest quality, due mainly to the lack of predictability in the treatment, not allowing a precise and direct plan for the case addressed. Among the most recurrent surgical procedures in this scenario, it is the canine tooth traction surgery included. A situation that occurs frequently during adolescence, requi r- ing a great deal of inference from the responsible professional, that if isn’t treated in time, may compromise the reorganization of other teeth and bring irremediable sequelae in long term. In this context, this research aimed at the development of a technology solution for o r- thodontic planning and treatment of included teeth, where clinical cases were used in which it was indicated the surgery of traction and subsequent alignment of canine teeth included. Free and recent software were analyzed that offered the potential to improve the planning process and subsequent treatment through the creation of a biomodel to serve as the basis of the deci- sions of the surgeon and orthodontists acting in the correction of the problem. In this way the present master's work presents a process of software use, which allows the end user to have a free manipulation on the images in the pre-prototyping phase, thus generating a biomodel that carries beyond the visual load obtained through the treatment of DICOM images, the traject o- ry traversed by the tooth during the surgery, allowing also a virtual simulation of the surgery. / A Manufatura Aditiva (MA), atualmente estende a sua utilização desde a fabricação de pe- quenos protótipos diversos, até a recente aplicação no âmbito da odontologia, destinada ao planejamento, simulação, teste e ensaio de cirurgias e outros procedimentos odontológicos. Algumas cirurgias ortodônticas são dotadas de níveis de dificuldade e requerem destreza altís- sima, devido principalmente à falta de previsibilidade no tratamento, não permitindo um pla- nejamento preciso e direto para o caso abordado. Dentre os procedimentos cirúrgicos mais recorrentes nesse cenário está a cirurgia de tracionamento de dentes caninos inclusos. Situa- ção que ocorre com grande frequência durante a adolescência, exigindo grande poder de infe- rência por parte do profissional responsável, que se não tratada a tempo pode vir a comprome- ter a reorganização dos demais dentes e trazer sequelas irremediáveis a longo prazo. Nesse contexto, esta pesquisa objetivou o desenvolvimento de uma solução de tecnologia para pla- nejamento e tratamento ortodôntico de dentes inclusos, onde foram utilizados casos clínicos nos quais estava indicada a cirurgia de tracionamento e posterior alinhamento de dentes cani- nos inclusos. Foram analisados softwares livres e recentes que oferecessem potencial de apri- morar o processo de planejamento e posterior tratamento através da confecção de biomodelo a servir como base das decisões do cirurgião e ortodontistas atuantes na correção do problema. Dessa forma o presente trabalho de mestrado apresenta um processo de utilização de software, que permite que o usuário final tenha uma livre manipulação sobre as imagens na fase de pré- prototipagem, gerando assim um biomodelo que carregue além da carga visual obtida através do tratamento de imagens DICOM, a trajetória percorrida pelo dente durante a cirurgia, permitindo também uma simulação virtual da cirurgia.
14

Estudo comparativo da ação biomecânica de alças ortodônticas confeccionadas em fios retangulares\" / Comparative study of biomechanical action of orthodontic loops made with rectangular wires

Eliane Cecilio 10 November 2006 (has links)
No tratamento das maloclusões muitas vezes se impõe a necessidade de extrações dentárias para cumprir as metas do tratamento ortodôntico em busca da oclusão normal. Um dos recursos para o fechamento de espaços após exodontias é a utilização de arcos de retração com alças. Atualmente existe, no mercado, uma grande disponibilidade de arcos pré-fabricados, fornecidos por diversos fabricantes, que apresentam variações na forma e número de alças, espessura dos fios e ligas metálicas diferentes. O conhecimento das propriedades mecânicas e das forças liberadas por estes arcos é de extrema importância para que se obtenha uma resposta biológica adequada durante a movimentação dentária. O presente estudo procurou avaliar, experimentalmente, as forças liberadas por alguns tipos mais utilizados de arcos com alças produzidos com fios de secção retangular com variações de geometria (espessura, número e forma das alças), liga metálica e fabricante, impondo-lhes diferentes ativações. Buscou-se ainda determinar a quantidade de ativação onde ocorre o limite de proporcionalidade e, finalmente, fazer comparações entre os arcos com o intuito de fornecer ao ortodontista subsídios para a escolha do arco adequado. Para tal foram utilizados 19 tipos diferentes de arcos submetidos a testes de tração. Foram registradas as forças continuamente até uma deformação das alças de 4 mm. As comparações foram realizadas por meio de testes estatísticos isolando-se apenas uma característica de variação permitindo uma melhor compreensão do fator preponderante na alteração da força. Os resultados revelaram variações importantes nas forças a cada 0,5 mm de ativação, sendo de forma geral, ativações de 0,5 e 1,0 mm as que liberam forças mais adequadas. Os limites de proporcionalidade ocorreram na sua maioria acima de 1,5 mm de ativação até 2,5 mm, podendo em arcos mais flexíveis ocorrer acima de 4,0 mm. As comparações estatísticas demonstraram diferenças significativas entre todos os grupos avaliados, revelando que todas as variações (geometria, espessura, material e fabricante) exercem influência sobre a força gerada, sendo que a liga metálica parece ser preponderante. / In malocclusion treatments, dental extractions become necessary, in some cases, in order to achieve orthodontic goals of normal occlusion. One of the devices employed to close spaces after dental extraction is the use of retraction arches with loops. Nowadays, there is a wide range of pre-manufactured arches in the market, which present variations in shape, number of loops, thickness of the wire and metallic alloys. It is extremely important to understand mechanical properties as well as the forces delivered by these arches in order to achieve proper biological response during tooth movement. The present study tried to evaluate, experimentally, forces delivered by some of the most frequently employed arches made of rectangular wires with different geometrical characteristics (thickness, number and shape of loops), metallic alloys and made by different manufacturers, when submitted to different levels of activation. It was tried to determine the activation level at proportional limit and compare these values for different arches, in order to provide the orthodontists with accurate data which may help them to choose the proper arches. Nineteen different types of arches were submitted to tension tests. Forces were continuously measured up to 4 mm level of loop deformation. Statistical tests were employed to make comparisons, with only one type of variation for each test, which allowed a better comprehension of the main factor in force change. Results revealed important variations in forces at 0.5 mm intervals, and generally, 0.5 mm and 1.0 mm levels of activation delivered the most proper forces. Proportional limit occurred, mostly, over 1.5 mm and up to 2.5 mm levels of activation, except for more flexible arches, when it occurred above 4.0 mm. Statistical comparisons showed significant differences between all groups studied, demonstrating that all variations (geometry, thickness, material and manufacturer) can influence the delivered force. In spite of this, metallic alloys seemed to be the most important factor determining force deliverance variation.

Page generated in 0.0373 seconds