• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Particle swarm optimization and differential evolution for base station placement with multi-objective requirements

Pereira, Marciel Barros 15 July 2015 (has links)
PEREIRA, M. B. Particle swarm optimization and differential evolution for base station placement with multi-objective requirements. 2015. 72 f. Dissertação (Mestrado em Engenharia de Teleinformática) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-09-21T12:31:09Z No. of bitstreams: 1 2015_dis_mbpereira.pdf: 3666612 bytes, checksum: bc2466a863d5e64d596e5667f3ef5426 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-10-09T14:45:25Z (GMT) No. of bitstreams: 1 2015_dis_mbpereira.pdf: 3666612 bytes, checksum: bc2466a863d5e64d596e5667f3ef5426 (MD5) / Made available in DSpace on 2015-10-09T14:45:26Z (GMT). No. of bitstreams: 1 2015_dis_mbpereira.pdf: 3666612 bytes, checksum: bc2466a863d5e64d596e5667f3ef5426 (MD5) Previous issue date: 2015-07-15 / The infrastructure expansion planning in cellular networks, so called Base Station Placement (BSP) problem, is a challenging task that must consider a large set of aspects, and which cannot be expressed as a linear optimization function. The BSP is known to be a NP-hard problem unable to be solved by any deterministic method. Based on some fundamental assumptions of Long Term Evolution - Advanced (LTE-A) networks, this work proceeds to investigate the use of two methods for BSP optimization task: the Particle Swarm Optimization (PSO) and the Differential Evolution (DE), which were adapted for placement of many new network nodes simultaneously. The optimization process follows two multi-objective functions used as fitness criteria for measuring the performance of each node and of the network. The optimization process is performed in three scenarios where one of them presents actual data collected from a real city. For each scenario, the fitness performance of both methods as well as the optimized points found by each technique are presented / O planejamento de expansão de infraestrutura em redes celulares é uma desafio que exige considerar diversos aspectos que não podem ser separados em uma função de otimização linear. Tal problema de posicionamento de estações base é conhecido por ser do tipo NP-hard, que não pode ser resolvido por qualquer método determinístico. Assumindo características básicas da tecnologia Long Term Evolution (LTE)-Advanced (LTE-A), este trabalho procede à investigação do uso de dois métodos para otimização de posicionamento de estações base: Otimização por Enxame de Partículas – Particle Swarm Optimization (PSO) – e Evolução Diferencial – Differential Evolution (DE) – adaptados para posicionamento de múltiplas estações base simultaneamente. O processo de otimização é orientado por dois tipos de funções custo com multiobjetivos, que medem o desempenho dos novos nós individualmente e de toda a rede coletivamente. A otimização é realizada em três cenários, dos quais um deles apresenta dados reais coletados de uma cidade. Para cada cenário, são exibidos o desempenho dos dois algoritmos em termos da melhoria na função objetivo e os pontos encontrados no processo de otimização por cada uma das técnicas
2

Análise e projeto via algoritmo de otimização heurística de um controlador de ordem fracionária PIλ para a melhoria do desempenho de um controle em tensão utilizado em micro redes / Analysis and design of fractional order controller PIλ via heuristic optimization algorithm to improve the performance of a voltage control applied in micro grids

Klebber de Araújo Ottoboni 19 February 2016 (has links)
A inclusão de fontes alternativas no sistema de energia elétrica possibilita a otimização dos recursos naturais disponíveis para geração. A conexão dessas fontes deve ser efetuada de forma a evitar índices de qualidade de energia incondizentes aos limites estabelecidos por normas nacionais e internacionais. Nesse contexto, sistemas de Geração Distribuída (GD) conectados à rede de distribuição via controle tensão/potência utilizam controladores Proporcional+Ressonantes (P+R) para produzir tensões com mínimas distorções na presença de cargas não lineares. Além disso, esse tipo de solução apresenta resultados satisfatórios na presença de outros tipos de carga (linear, não linear e conexão de máquina de indução), entretanto, para uma carga RLC com frequência de ressonância igual à frequência fundamental, o sistema de GD torna-se instável e as distorções harmônicas ultrapassam os limites mínimos estabelecidos para assegurar a qualidade de energia. Dessa forma, essa dissertação de mestrado propõe a substituição do controlador P+R da frequência fundamental por um controlador de ordem fracionária PIλ, projetado através de um algoritmo de otimização heurística. Os resultados obtidos através de simulação demonstram que o controlador proposto apresenta resultados satisfatórios para todas as cargas testadas: Não Linear; Motor de Indução Trifásico e RLC com frequência de ressonância igual à fundamental da rede. Entretanto, os resultados experimentais mostraram uma sensibilidade quanto à mudança de carga e quanto aos parâmetros de discretização do controlador, sugerindo a necessidade de uma análise mais rigorosa na etapa de projeto de modo a se ter robustez quanto à variação de carga. / The insertion of alternative sources in the power system enables the optimization of natural resources available for electrical generation. The connection of these sources to the grid has to be made in order to avoid indices of power quality greater than the limits established by national and international standards. In this context, a Distributed Generation (DG) systems connected to the grid via voltage/power control use a proportional+resonant (P+R) controller to produce not only the fundamental frequency but also to reduce the voltage distortion when nonlinear loads are connected to the DG terminals. Additionally, this type of solution shows satisfactory results for linear, balanced, unbalanced and direct connection of induction machine as well. However, for parallel RLC load with frequency of resonance equals to the fundamental frequency of the grid, the DG system operation becomes unstable with high levels of harmonic distortions and an oscillatory behavior. In this context, we propose the replacement of the PR controller for the fundamental frequency by a fractional order controller PIλ designed via a heuristic optimization algorithm. To prove the feasibility of the proposed approach a set of simulations are presented, however, the experimental prototype shown the sensitivity of the controller for different loads and for the controller discretization parameters suggesting the need for more analysis during the design procedures of the PIλ controller to achieve the expected robustness.
3

Análise e projeto via algoritmo de otimização heurística de um controlador de ordem fracionária PIλ para a melhoria do desempenho de um controle em tensão utilizado em micro redes / Analysis and design of fractional order controller PIλ via heuristic optimization algorithm to improve the performance of a voltage control applied in micro grids

Ottoboni, Klebber de Araújo 19 February 2016 (has links)
A inclusão de fontes alternativas no sistema de energia elétrica possibilita a otimização dos recursos naturais disponíveis para geração. A conexão dessas fontes deve ser efetuada de forma a evitar índices de qualidade de energia incondizentes aos limites estabelecidos por normas nacionais e internacionais. Nesse contexto, sistemas de Geração Distribuída (GD) conectados à rede de distribuição via controle tensão/potência utilizam controladores Proporcional+Ressonantes (P+R) para produzir tensões com mínimas distorções na presença de cargas não lineares. Além disso, esse tipo de solução apresenta resultados satisfatórios na presença de outros tipos de carga (linear, não linear e conexão de máquina de indução), entretanto, para uma carga RLC com frequência de ressonância igual à frequência fundamental, o sistema de GD torna-se instável e as distorções harmônicas ultrapassam os limites mínimos estabelecidos para assegurar a qualidade de energia. Dessa forma, essa dissertação de mestrado propõe a substituição do controlador P+R da frequência fundamental por um controlador de ordem fracionária PIλ, projetado através de um algoritmo de otimização heurística. Os resultados obtidos através de simulação demonstram que o controlador proposto apresenta resultados satisfatórios para todas as cargas testadas: Não Linear; Motor de Indução Trifásico e RLC com frequência de ressonância igual à fundamental da rede. Entretanto, os resultados experimentais mostraram uma sensibilidade quanto à mudança de carga e quanto aos parâmetros de discretização do controlador, sugerindo a necessidade de uma análise mais rigorosa na etapa de projeto de modo a se ter robustez quanto à variação de carga. / The insertion of alternative sources in the power system enables the optimization of natural resources available for electrical generation. The connection of these sources to the grid has to be made in order to avoid indices of power quality greater than the limits established by national and international standards. In this context, a Distributed Generation (DG) systems connected to the grid via voltage/power control use a proportional+resonant (P+R) controller to produce not only the fundamental frequency but also to reduce the voltage distortion when nonlinear loads are connected to the DG terminals. Additionally, this type of solution shows satisfactory results for linear, balanced, unbalanced and direct connection of induction machine as well. However, for parallel RLC load with frequency of resonance equals to the fundamental frequency of the grid, the DG system operation becomes unstable with high levels of harmonic distortions and an oscillatory behavior. In this context, we propose the replacement of the PR controller for the fundamental frequency by a fractional order controller PIλ designed via a heuristic optimization algorithm. To prove the feasibility of the proposed approach a set of simulations are presented, however, the experimental prototype shown the sensitivity of the controller for different loads and for the controller discretization parameters suggesting the need for more analysis during the design procedures of the PIλ controller to achieve the expected robustness.

Page generated in 0.0844 seconds