• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do tratamento de oxidação a plasma na produção de uma bicamada SiOx/SiOxCyHz / Effect of plasma oxidation treatment on production of a SiOx/SiOxCyHz bilayer

Ribeiro, Rafael Parra 16 August 2017 (has links)
Submitted by RAFAEL PARRA RIBEIRO null (rafa_parra1988@yahoo.com.br) on 2018-01-11T11:50:55Z No. of bitstreams: 1 Dissertação Versão FINAL 3.0.pdf: 3444946 bytes, checksum: 0a56c18e1734b605a90aea40283cc295 (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-01-11T13:13:15Z (GMT) No. of bitstreams: 1 ribeiro_rp_me_bauru.pdf: 3444946 bytes, checksum: 0a56c18e1734b605a90aea40283cc295 (MD5) / Made available in DSpace on 2018-01-11T13:13:15Z (GMT). No. of bitstreams: 1 ribeiro_rp_me_bauru.pdf: 3444946 bytes, checksum: 0a56c18e1734b605a90aea40283cc295 (MD5) Previous issue date: 2017-08-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Devido às suas propriedades mecânicas, soldabilidade e baixo custo, o aço carbono é um material amplamente utilizado nos mais diversos setores. Entretanto, o aço carbono é facilmente oxidado quando exposto ao ambiente. Para evitar esse problema, alguns trabalhos sugerem o desenvolvimento de revestimentos protetivos utilizando técnicas de deposição a plasma baseadas no composto hexametildisiloxano, HMDSO. A partir deste composto podese obter desde estruturas organosilicones até as inorgânicas pela alteração dos parâmetros de deposição. Revestimentos tipo óxido de silício são mais resistentes à corrosão que os organosilicones, porém sua estabilidade física é menor. Com o objetivo de associar as propriedades favoráveis de ambos os tipos de revestimentos, investigou-se, no presente trabalho, a possibilidade de revestir o aço carbono com sistemas bicamadas SiOx/SiOxCyHz através da combinação de metodologia de deposição e oxidação em plasmas de baixa pressão. Para tanto, filmes do tipo SiOxCyHz foram depositados a plasma de mistura de HMDSO (70%), O2 (20%) e Ar (10%) excitado por radiofrequência (150 W). A pressão total da atmosfera de deposição foi de 20 Pa. Os filmes foram depositados por 30 min e, posteriormente, expostos a plasmas de O2 (3,3 Pa, 10-300 W, 60 min) com o objetivo de criar uma camada superficial inorgânica. Foram investigados os efeitos da potência de excitação do plasma de O2 na espessura de camada, estrutura química e composição elementar das amostras. Avaliou-se também o efeito da potência do plasma de oxidação nas propriedades de barreira do revestimento depositado sobre aço carbono. Filmes como-depositados foram caracterizados como organosilicones. A exposição ao plasma de oxigênio foi observada remover hidrogênio, carbono e grupos metil da estrutura transformando-a em óxido de silício, sendo, todavia, o grau de conversão e a espessura da camada convertida fortemente dependentes da potência do plasma de oxidação. A resistência do sistema preparado sobre o aço carbono à corrosão foi observada depender da espessura final da camada e também da conectividade da estrutura convertida em sílica mais que do grau de conversão. A condição de tratamento eleita como ótima neste trabalho foi a conduzida com 50 W de potência por criar uma camada superficial inorgânica fina, compacta, com uma estrutura superficial similar a da sílica além de preservar a espessura do filme e aumentar as propriedades de barreira do sistema. / Due to its mechanical properties, welding and low cost, carbon steel is a material widely used in several sectors. However, carbon steel is easily oxidized when exposed to the environment. To avoid this problem, some work suggests the development of protective coating using plasma deposition techniques based on the compound hexamethyldisiloxane, HMDSO. From this compound it is possible to obtain from organosilicones structures to inorganic by changing the parameters of deposition. Silicon oxide type coatings are more resistant to corrosion than organosilicones, but their physical stability is lower. With the objective of associating the favorable properties of both types of coatings, the present work investigated the possibility of coating the carbon steel with SiOx/SiOxCyHz bilayer systems through the combination of deposition and oxidation methodology in low pressure plasmas. For that, SiOxCyHz films were deposited in a mixture plasma of HMDSO (70%), O2 (20%) and Ar (10%) excited by radiofrequency (150 W). The total pressure of the atmosphere of deposition was 20 Pa. The films were deposited for 30 min and subsequently exposed to O2 plasmas (3.3 Pa, 10-300 W, 60 min) to create an inorganic surface layer. The effects of the excitation power of the O2 plasma on the layer thickness, chemical structure and elemental composition of the samples were investigated. The effect of the oxidation plasma power was also evaluated in the barrier properties of the coating deposited on carbon steel. As-deposited films were characterized as organosilicones. Exposure to oxygen plasma was observed to remove hydrogen, carbon and methyl groups from the structure transforming it into a silicon oxide, however, the degree of conversion and the thickness of the converted layer is strongly dependent on the power of the oxidation plasma. The corrosion resistance of the system prepared on carbon steel was observed to depend on the final thickness of the layer and also on the connectivity of the structure converted to silica rather than the degree of conversion. The treatment condition chosen as optimal in this work was the one conducted with 50 W of power by creating a thin, compact, inorganic surface layer with a silica-like surface structure in addition to preserving the film thickness and increasing the barrier properties of the system. / 1560670 / 1545023
2

Tratamento de superfície por oxidação à plasma eletrolítico para viabilizar o uso de implantes biomédicos: da Telessaúde para o SUS / Surface treatment by plasma electrolytic oxidation to viabilize the use of biomedical implants: from Telessaúde to SUS

Paiva, Ana Karenina de Oliveira 23 March 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-05-03T22:29:48Z No. of bitstreams: 1 AnaKareninaDeOliveiraPaiva_DISSERT.pdf: 827570 bytes, checksum: 54cd7a519a5117b82729598fcbd25a05 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-05-14T20:48:58Z (GMT) No. of bitstreams: 1 AnaKareninaDeOliveiraPaiva_DISSERT.pdf: 827570 bytes, checksum: 54cd7a519a5117b82729598fcbd25a05 (MD5) / Made available in DSpace on 2018-05-14T20:48:58Z (GMT). No. of bitstreams: 1 AnaKareninaDeOliveiraPaiva_DISSERT.pdf: 827570 bytes, checksum: 54cd7a519a5117b82729598fcbd25a05 (MD5) Previous issue date: 2018-03-23 / Com base nos princípios constitucionais de integralidade e equidade, tornou-se necessário viabilizar a incorporação dos procedimentos ortodônticos e implante dentário pelo setor público de saúde. Um estudo realizado pelo Ministério da Saúde verificou a redução no componente cariado de 35%, a redução desse índice viabilizou a introdução desses implantes no Sistema Único de Saúde (SUS). Apesar da implementação para no máximo 6 implantes por paciente nos centros de especialidades odontológicas, o custo do tratamento superficial de implantes ainda é elevado e impacta no preço final para indústria. Com o objetivo de resolver esse problema, foi utilizado o método de tratamento de superfície de Oxidação por Plasma Eletrolítico (PEO). Tratou-se 18 cilindros de titânio grau II, com 3 mm de diâmetro e 25 mm de comprimento. O tempo de tratamento utilizado foi de 1, 8 e 16 minutos. A solução eletrolítica estava na temperatura ambiente e a tensão aplicada foi de 290 V. Após os tratamentos, as amostras foram caracterizadas por Fluorescência de Raios-X (FRX), Microscopia Ótica (MO), Microscopia Eletrônica de Varredura (MEV) e por Espectroscopia de Raios-X e Energia Dispersiva (EDS). Em seguida foi feito Microscopia de Força Atômica (AFM) para caracterização da textura superficial. Identificou-se neste trabalho através das análises químicas pela Fluorescência de Raios-X a presença do TiO2 na superfície da amostra. Verificou-se no MEV que os revestimentos exibem uma característica porosa, apresentando uma interface bem aderida e sem presença de espaços vazios. Nas imagens do AFM observou-se que com o aumento do tempo de tratamento houve uma maior rugosidade e aumento da homogeneidade da distribuição dos cristais cerâmicos na superfície. Nos ensaios de molhabilidade apresentaram um ângulo de molhamento menor para as amostras com o tratamento por PEO com tempo de 1 e 8 minutos. Conclui-se que a técnica por Oxidação por Plasma Eletrolítico mostrou-se eficaz na deposição de um revestimento cerâmico, melhorando a qualidade da superfície reduzindo o custo do tratamento superficial, diminuindo o valor final do implante para implementação no SUS. / Based on the constitutional principles of integrality and equity, it became necessary to enable the incorporation of orthodontic procedures and dental implant by the public health sector. A study carried out by the Ministry of Health verified the reduction in the caries component of 35%, the reduction of this index made possible the introduction of these implants in the Unified Health System (Sistema Único de Saúde - SUS). Despite the implementation for a maximum of 6 implants per patient in dental specialty centers, the cost of surface treatment of implants is still high and impacts on the final price for the industry. In order to solve this problem, the surface treatment method of Plasma Electrolytic Oxidation (PEO) was used. They were treated with 18 cylinders of grade II titanium, 3 mm in diameter and 25 mm in length. The treatment time was 1, 8 and 16 minutes. After the treatments, the samples were characterized by X-Ray Fluorescence (FRX), Optical Microscopy (OM), Scanning Electron Microscopy (SEM) and Spectroscopy of X-rays and Dispersive Energy (ESD). Afterwards, it was made Atomic Force Microscopy (AFM) to characterize the surface texture. The presence of TiO2 on the surface of the sample was identified by X-Ray Fluorescence in this work. It was verified in the SEM that the coatings exhibit a porous characteristic, presenting an interface well adhered and without presence of empty spaces. In the images of the AFM, it was observed that with the increase of the treatment time there was a greater roughness and increase of the homogeneity of the distribution of the ceramic crystals in the surface. In the wettability tests they presented a lower wetting angle for the samples with PEO treatment with time of 1 and 8 minutes. It is concluded that the Plasma Electrolytic Oxidation technique proved to be effective in the deposition of a ceramic coating, improving the quality of the surface reducing the cost of surface treatment, reducing the final value of the implant for implementation in the SUS.

Page generated in 0.0583 seconds