• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 16
  • 9
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 68
  • 17
  • 14
  • 11
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Computational Approach to Determining the Intrinsic Impedance of Perforated Metal Sheets

Kiley, Erin M 04 May 2011 (has links)
Perforated metal sheets are frequently used in electric and electronic devices, and in most cases, these metal structures should comply with some electromagnetic compatibility constraints which impose certain conditions on penetrating electromagnetic radiation, quality of shielding, and other characteristics. Currently, many issues in electronic system design could be handled with advanced mathematical and computer models; however, direct reproduction of perforation in these models may result in a significantly increased computational cost. This work is concerned with modeling perforated metal sheets whose apertures have diameters significantly smaller than the wavelength of radiation. We suggest an original approach for computation of intrinsic impedance from the reflection and transmission coefficients obtained by FDTD simulation of the perforated sheet placed in a rectangular waveguide. The calculated impedance can be used to characterize the perforated segment as a solid metal plate which has the same effective material parameters, including electric conductivity. Functionality of the proposed technique is illustrated with a model of a microwave oven that has two perforated wall segments necessary for ventilation and lighting. After computing the impedance of these segments, they are replaced in the model by solid metal with equivalent effective conductivity, which allows for practical simulation of electromagnetic processes in the oven without any increase in the computational resources required. Computations show that the presence of perforated segments on the walls of this microwave oven makes a negligible impact on the frequency characteristics of the systemâ€"so in corresponding full-wave models, the segments can be replaced by solid metal walls without compromising accuracy of simulation.
2

Häufigkeit und Therapie der Perforation der Schneiderschen Membran bei der Sinusbodenaugmentation / Frequency and therapy of the perforation of the schneiderian membrane at the sinus floor elevation

Häckel, Gregor January 2012 (has links) (PDF)
Die Sinusbodenelevation ist mittlerweile als sehr sicheres und vorhersagbares Standardverfahren zur Herstellung eines ausreichenden vertikalen Knochenangebotes im atrophierten posterioren Oberkiefer anzusehen. Neben der komplikationslosen Einheilung des Augmentats und der Implantate kann es, wie bei jedem anderen chirurgischen Eingriff auch, zum Auftreten von Komplikationen kommen. Die häufigste intraoperative Komplikation stellt dabei die Perforation der Schneiderschen Membran dar. Im Falle einer Membranperforation steht dem Operateur jedoch eine Vielzahl verschiedener Behandlungsmöglichkeiten zur Verfügung. Die gängigsten Methoden reichen vom Verschluss der Lazeration durch die Verwendung von Fibrinkleber, resorbierbarer Kollagenmembran, dem Nahtverschluss mit resorbierbarem Nahtmaterial bis hin zum Verschluss der Perforation durch die erweiterte Mobilisation der Kieferhöhlenschleimhaut. Überschreitet die Perforationsgröße jedoch einen kritischen Wert, so wird ein Abbruch der Operation ohne Sinuslift empfohlen, damit die Kieferhöhlenschleimhaut ausheilen kann. Ein späterer Versuch der Sinusbodenelevation ist nach Abheilung möglich. Grundsätzlich wird als medikamentöse Prophylaxe zum Schutz vor sinuidalen Infektionen eine orale Antibiotikagabe empfohlen. Jede dieser Therapiemethoden besitzt ein spezielles Indikationsspektrum, welches sich entsprechend der Art, Größe und Lokalisation der Perforation definiert. Eine international gültige Klassifikation der Perforationen mit der Empfehlung für eine spezielle Therapie gibt es allerdings nicht. Die Verwendung einer Barrieremembran zum Verschluss der Ruptur konnte sich aufgrund der einfachen Anwendung und der günstigen Prognose etablieren. Die verwendeten Knochenersatzmaterialien zur Schaffung eines suffizienten Implantatlagers im atrophierten posterioren Oberkiefer besitzen günstige Einheilungsprognosen. Sie können in Kombination mit autologem Knochen, aber auch in alleiniger Form, ein ausreichendes Knochenlager schaffen. Interessanterweise hatten auch Perforationen der Schneiderschen Membran ebenso wie Wunddehiszenzen keinerlei Einfluss auf den Knochengewinn oder die Einheilung des Knochenersatzmaterials und der Implantate. Lediglich bei der Verwendung unterschiedlicher Knochenersatzmaterialien zur Füllung des subantralen Hohlraumes lieferte die statistische Analyse signifikante Werte. Daneben muss eine Implantatüberlebensrate von 96,1 % im augmentierten Sinus als positives Ergebnis festgehalten werden. Zusammenfassend lässt sich sagen, dass körperfremde Knochenersatzmaterialien bei vertikalen Kieferhöhlenaugmentationen sinnvolle Alternativen zu autologem Knochenmaterial darstellen, da durch ihre Verwendung die Komorbidität eines Zweiteingriffs zur Gewinnung autologen Transplantatmaterials verhindert wird. Insbesondere im Rahmen von Sinusbodenelevationen können sie erfolgreich verwendet werden und besitzen eine günstige Prognose. Humane allogene Knochenersatzmaterialien besitzen eine gute Biokompatibilität, daneben bergen sie aber auch das Risiko einer HIV-, HCV- und Prionentransmission. Die aktuell verfügbaren osteokonduktiven Materialien auf Tricalciumphosphatbasis hingegen besitzen aufgrund der vollsynthetischen Herstellung kein Infektionsrisiko und weisen eine vergleichbar gute Biokompatibilität sowie eine unterschiedliche mechanische Stabilität auf, eine osteoinduktive Wirkung fehlt jedoch. Xenogene Knochenersatzmaterialien indes sind dem menschlichen Knochen ähnlich, besitzen daher eine hohe Biokompatibilität und werden vom Körper in körpereigenen Knochen um- bzw. eingebaut. Sie besitzen zudem osteokonduktive Eigenschaften. Unter Berücksichtigung all dieser Aspekte lässt sich abschließend sagen, dass sich die Sinusbodenelelvation in ihrer heutigen Form zu einer relativ sicheren und gut vorhersagbaren Behandlungsmöglichkeit zur Erweiterung des Knochenangebots im posterioren Oberkiefer entwickelt hat. Daneben hat sich die Verwendung von Knochenersatzmaterialien zur Füllung des subantralen Hohlraumes unter Berücksichtigung aller notwendigen anamnestischen Maßnahmen und sorgfältigen präoperativen Behandlungsplanung ebenso zu einer sinnvollen Behandlungsmöglichkeit entwickelt. / The most frequent complication of the sinus floor elevation is the perforation of the schneiderian membrane. The results are pathological sequelae like the inflammation of the sinus maxillaris which can lead to the loss of the augmentation material or the already inserted implants.
3

Etude du comportement élastique et plastique de revêtements élaborés par projection plasma : Mise au point d'une méthode de caractérisation des propriétés mécaniques par perforation et comparaison avec les propriétés obtenues par indentation / Elastic and plastic behavior of thermal spray coatings : characterization method development for mechanical properties and comparisons with properties determined by indentations tests

Palacio Espinosa, Claudia 15 December 2016 (has links)
Les dépôts élaborés par projection thermique sont largement utilisés pour des applications de hautes performantes grâce à leurs propriétés mécaniques élevées (dureté et module d’Young). La détermination de ces propriétés est donc importante. Elles sont habituellement mesurées par des méthodes d’indentation en utilisant des indenteurs Vickers, Knoop et Berkovich. Mais ces méthodes de mesure nécessitent des équipements sophistiqués, une préparation rigoureuse des surfaces et la réalisation qui les rend coûteuse et difficile à mettre en oeuvre. Les travaux de cette thèse portent sur l’étude de la résistance à la perforation comme méthode alternative pour déterminer les propriétés mécaniques de dépôts céramiques élaborés par projection plasma. Pour ce faire, six poudres de compositions chimiques les plus souvent utilisées au niveau de l’industrie ont été sélectionnées pour élaborer les dépôts par projection plasma : Al2O3, TiO2, Al2O3-15wt % TiO2, Al2O3-43wt % TiO2, YSZ et Al2O3-YSZ. Les propriétés physico-chimiques et mécaniques des dépôts ont été déterminées. Les macro et micro duretés ont été déterminées par des indentations Vickers, le module d’Young a été calculé à partir des mesures de la micro dureté Knoop et la ténacité à la fracture a été déterminée à partir des résultats de micro dureté Vickers. La résistance à la perforation en mode statique a été conduite en utilisant des forets pour le perçage de verre et en traçant des courbes de charges (P) en fonction de la profondeur (h) d’enfoncement de la pointe du foret dans la surface du dépôt. Des rapports entre la charge et les aires de contact et de la section transversale de la pointe du foret (P/Ac et P/At respectivement), correspondant à la profondeur de pénétration du foret, ont été établis, permettant de définir la dureté par perforation statique (HDs). A partir des pentes ΔP/ΔAc et ΔP/ΔAt lors de la décharge des courbes P-h, le module d’élasticité par perforation statique (Es) a été déterminé. HDs et Es ont montré une bonne correspondance avec la micro dureté et le module d’Young déterminés par les méthodes classiques d’indentation et une haute reproductibilité des résultats. L’apparition de fissures et d’écaillage sur la surface des dépôts lors de l’étape de charge a mis en évidence une réduction de la pente des courbes P-h qui pourrait être utilisée pour trouver des corrélations avec la ténacité à la fracture. Sous le mode dynamique, les essais de résistance à la perforation ont été conduits en utilisant des forets pour le perçage des métaux (de type HSS) et pour la maçonnerie. Les rapports entre la charge appliquée et les aires de contact et de la section transversale (P/Ac et P/At respectivement) pour une profondeur h de la pointe du foret dans la surface des dépôts ont été utilisés pour calculer la dureté par perforation dynamique (HDD). Les résultats ont montré une bonne correspondance avec la micro dureté Vickers malgré la plus faible reproductibilité que ceux obtenus en mode statique. / Thermal sprayed ceramic coatings are highly used in application where high performance regarding to mechanical properties are required. Thus it is essential to determine the coatings’ mechanical properties (hardness, Young modulus and fracture toughness), which is made by classical indentation methods using Vickers, Knoop and Berkovich indenters. Those methods use sophisticated devices, rigorous sample preparation and demanding time processes in execution and data analysis that make them expensive and complicated in implementation. This research is focused tostudy the drilling resistance as an alternative method to measure the mechanical properties of atmospheric plasma spray ceramic coatings. For these purpose powders of six chemical compositions most widely used in industrial applications were employed as feedstock powders to manufacture coatings by atmospheric plasma spraying: Al2O3, TiO2, Al2O3-15wt % TiO2, Al2O3-43wt % TiO2, YSZ and Al2O3-YSZ. Physical, chemical and mechanical properties have been determined. Macro and micro hardnesses were determined by Vickers indentations, the Young’s modules werecalculated from Knoop micro hardness measurements and fracture toughness from Vickers micro hardness. Static drilling resistance tests were carried out with commercial drill bits used to perforate glass plotting the applied force (P). against the drill bit depth (h). Relationships between the applied force and the bit’s contact or cross sectional areas (P/Ac and P/At respectively) corresponding to the drilled depth (h) were used to set the Static Drilling Hardness (HDs).Furthermore, the slopes in the unloading stage corresponding to ΔP/ΔAc or ΔP/ΔAt were used to calculate the Static Drilling Elastic Modulus (Es). The HDs and Es results exhibit both well fit with the micro-hardness and Young modulus measurements made by classical methods and high reproducibility in the results. It was observed that cracks and spalling produced on the coatings surfaces during loading reduce the slope of the P vs h plot which could be used in future studies to correlate to the toughness of coatings. Dynamic drilling tests using bits to perforate metals (HSS) andmasonry were also carried out. The ratios between applied load and contact or cross sectional areas (P/Ac and P/At respectively) corresponding to the depth (h) of the hole drilled on each coating were used to calculate the Dynamic Drilling Hardness HDD which shows a good fit with the measured hardness on the surface of coatings realized by micro-indentation Vickers but lower reproducibility than those obtained with static drilling hardness results.
4

The effects of plasminogen deficiency on the healing of tympanic membrane perforations /

Hansson, Annika, January 2007 (has links)
Diss. (sammanfattning) Umeå : Univ., 2007. / Härtill 4 uppsatser.
5

Avaliação de um serviço de histeroscopia cirurgica em um hospital universitario / Assessment of an operative hysteroscopy Unity at an University Hospital

Hidalgo, Simone Ravacci 27 August 2008 (has links)
Orientadores: Ilza Maria Urbano Monteiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T13:46:36Z (GMT). No. of bitstreams: 1 Hidalgo_SimoneRavacci_M.pdf: 1290897 bytes, checksum: c6ce76b97515ddd12198bcbcfe5132af (MD5) Previous issue date: 2008 / Resumo: Introdução: A cirurgia histeroscópica é indicada para o tratamento de doenças intra-uterinas como os pólipos endometriais, miomas submucosos, aderências e septos uterinos, além de investigação de infertilidade. O ensino da técnica histeroscópica costuma ser demorado, apresentando uma lenta curva de aprendizado. Apesar de ser um procedimento menos invasivo, não é livre de complicações e as principais são: perfuração uterina, laceração do colo do útero, absorção excessiva do meio líquido utilizado para distensão, infecção e hemorragia. Objetivo: comparar o serviço de histeroscopia cirúrgica do CAISM (Centro de Atenção Integral à Saúde da Mulher) em dois momentos (1999 e 2007), no que se refere ao tempo cirúrgico, à complexidade dos procedimentos e presença de complicações. Métodos: realizou-se um estudo descritivo de corte transversal, onde foram selecionadas 162 mulheres submetidas à histeroscopia cirúrgica em 1999 e 100 mulheres em 2007, no CAISM. Foram colhidos dados referentes ao tipo e duração do procedimento realizado, tipo e duração da anestesia e presença de complicações no ato operatório. Resultados: houve diminuição significativa do tempo de cirurgia (31,8 minutos para 19,7 minutos; p<0,0001) e do tempo de anestesia (160 min para 141,7 min; p=0,0246). A cirurgia mais realizada foi a polipectomia, com aumento de 54,8% para 71% (p=0,03). As taxas de complicações foram 8,06% e 9%, respectivamente em 1999 e 2007, com 8% de perfurações em ambos os períodos. Conclusão: a equipe cirúrgica evoluiu ao longo do tempo como demonstra o menor tempo de cirurgia sem aumento do número de complicações. A taxa de complicações está dentro do aceitável pela literatura, mas esforços devem ser feitos na tentativa de diminuir complicações. Palavras-chave: histeroscopia cirúrgica, complicações / Abstract: Introduction:hysteroscopy is indicated to treat intrauterine diseases such as endometrial polyps, submucous myomas, septate uterus, uterine synechiae and assessment of infertility. The main complications are uterine perforation, laceration of cervix, fluid overload, infection, hemorrhage. Objective: The purpose of this study was to compare the changes that ocurred in a operative hysteroscopy unit at a tertiary care university hospital in two different moments, analysing factors as operative time, procedure complexity and its complications. Methods: a retrospective descriptive study, including women undergoing operative hysteroscopy in two distinct periods (62 patients in 1999 and 100 in 2007), at CAISM/UNICAMP. Factors analysed were type and length of procedure, type and length of anesthesia, complications during the procedure, collected from medical reports. Results: there were a significant reduction in mean operative time (31,8 minutes to 19.7 minutes; p<0.0001) and mean anesthesia time (160 minutes to 141.7 minutes; p=0.0246). The most common procedure was polipectomy, increasing from 54.8% to 71% (p=0.03). The complication rate was 8.06% and 9%, respectively in 1999 and 2007, with 8% of uterine perforations. Conclusions: there was an evolution throughout the studied period as demonstrated by a decrease in operative time keeping the same complication rate, which is comparable to that in literature. More efforts should be taken to attempt less complications. Key words: operative hysteroscopy, complications / Mestrado / Tocoginecologia / Mestre em Tocoginecologia
6

Strain rate effects on energy dissipation during hypervelocity penetration of polymeric materials

Bowering, Michael Hunter 14 December 2018 (has links)
Energy dissipation during penetration is an important consideration in materials selection for lightweight armoring to protect against hypervelocity impacts (HVIs). Impact-induced glass transition in polymeric materials has been observed to increase energy dissipation during penetration. Incorporating unconventional armor materials like polymers could improve performance in these types of applications. A series of HVIs was performed, with impact velocities over the range of 2-7 km/s, on samples of ultra-high molecular weight polyethylene and poly(methyl methacrylate). A relationship between back face debris cloud velocity and impact velocity was developed for each material. Damage zone sizes were compared, offering insights into the effects of molecular architecture on stress delocalization and energy dissipation during hypervelocity perforation. Thermal analysis of the two material systems provides quasi-static glass transition temperatures, as well as melting and crystallization temperatures. The apparent failure mechanisms, in conjunction with thermal analysis, were used to explain the relative performance of each material.
7

AN IN VITRO COMPARISON OF PIEZOELECTRIC AND ROTARY OSTEOTOMIES DURING LATERAL SINUS WALL SURGERY

Nicolucci, Jeff Duncan January 2011 (has links)
Piezoelectric and high speed rotary instrumentation have proven to be viable methods of preparing osteotomies during lateral sinus wall surgery. Piezoelectric units have been suggested to have superior access and control as well as the ability to discern between soft and hard tissue. The major disadvantage of the piezoelectric technology is the reduced speed at which osteotomies are prepared. The purpose of this study was to evaluate the difference in operator perception, speed and membrane damage between the two modalities. Seven different operators prepared 4 osteotomies in 2 mm thick polyurethane sheets backed by 0.2 mm thick plastic wrap. The preparation speed and incidence of membrane damage were recorded after each osteotomy. The operator perception of each modality was recorded at the end of the preparations. Several questions were asked to evaluate the accuracy, visibility, vibration, comfort and ease of use of both modalities. Results showed that rotary instrumentation was 160% faster than piezo (p&lt;0.001), but resulted in 370% more damage and 130% more perforations (p&lt;0.01). Surveys of operator preference showed piezo units with higher scores for accuracy and visibility (p&lt;0.05). This study showed that in vitro a piezo unit compared to a rotary unit results in less membrane perforation and damage, higher perception of accuracy and visibility, but longer osteotomy preparation time. / Oral Biology
8

Lymphocytic Esophagitis: A Rare Disease on the Rise

Shipley, Lindsey C., Al Momani, Laith A., Locke, Allison, Young, Mark 04 February 2018 (has links)
Lymphocytic esophagitis is a rare, poorly understood disease. This case report presents a patient with a history of squamous cell carcinoma of the tongue who presented with dysphagia. He received esophageal dilation that unfortunately resulted in perforation. Biopsies showed lymphocytic esophagitis. There are very few cases in the literature describing perforation in lymphocytic esophagitis. In addition, management and treatment have been challenging for physicians; however, this case represents a complete symptomatic improvement in four to six weeks with a proton pump inhibitor.
9

Etude et évaluation d'une solution composite à renfort tissé interlock pour la protection balistique de véhicule

Provost, Benjamin 14 January 2013 (has links)
Cette thèse a été réalisée au sein des laboratoires du GEMTEX et du LAMIH, et porte sur l’étude et l’évaluation d’une solution composite à renfort tissé pour la protection balistique de véhicule. L’enjeu de cette thèse consiste à explorer le potentiel des solutions en composite à renfort tissé interlock 3D dans le cas d’unimpact à haute vitesse. Deux solutions composites ont été mis au point en laboratoire, intégrant le même renfort tissé interlock mais mis en oeuvre par deux procédés d'imprégnation différents. Ces composites ont été évalués à l’impact par un FSP (Fragment Simulating Projectile) de 20 mm de diamètre, dans une configuration de backing, c'est-à-dire en face arrière d’une plaque métallique utilisée pour la protection contre les impacts à haute vitesse.Plusieurs campagnes d’essais ont été réalisées permettant d’optimiser nos structures interlocks 3D afin de répondre au mieux à la sollicitation dynamique. Les résultats à l’impact de ces composites ont été comparés à ceux d’une solution composite dite de référence généralement utilisée dans les véhicules blindés à base de tissés 2D empilés suivant différentes directions. Ces essais nous ont permis de faire ressortir les performances de l’une des structures développée présentant des capacités de protection à l’impact supérieures aux composites de référence.Afin d’en comprendre les mécanismes des renforts mis en jeu, nous avons représenté numériquement ces tissus interlocks soumis à l’impact. Des modèles numériques innovants ont été simulés dans le but de représenter le renfort tissé de façon réaliste grâce aux mesures obtenues par micro-tomographie à rayons X. / This thesis was performed at the laboratories of GEMTEX and LAMIH on study and evaluation of a solution based on warp interlock reinforced composite for vehicle ballistic protection. The main purpose of this thesis is to explore the potential of warp interlock reinforced composite solutions in the case of a high velocity impact. We have chosen to study two composite solutions manufactured in our laboratory which presented the same warp interlock reinforcement but with different resins and infusion processes. Those composites were tested by an FSP (Fragment Simulating Projectile) impact as armour backing. Few campaign of tests were performed which helped us to optimize our warp interlock structure in order tohave a better response to the dynamic loading. The impact results of our composites have been compared with those of the benchmark which is a composite generally used backing. Thanks to these tests we had the possibility to observe that one of our structures present a better impact behaviour than the others. In order to improve our representation of those reinforcement, we have been working on the numerical modelling of those warp interlock submitted to impact. Innovative numerical models have been set up thanks to micro-tomography analysis allowing a more realistic representation of the reinforcement.
10

Modélisation multi-échelle d un assemblage riveté aéronautique - Vers un modèle de fragilisation structurale

Bayart, Anne-Sophie 08 September 2005 (has links) (PDF)
Dans le cadre de l'étude par éléments finis du crash des structures aéronautiques, la prédiction des modes de ruine engendrés au sein ou au voisinage des assemblages rivetés, telle la déchirure d'une tôle le long d'une ligne de rivets, s'avère, encore aujourd'hui, délicate. Dans ce contexte, une méthodologie permettant la formalisation et la caractérisation d'un modèle de fragilisation structurale est proposée. Ce modèle a pour objectif de simuler la rupture d'une plaque métallique perforée à un niveau macroscopique. La notion de fragilisation structurale est rappelée dans la première partie du mémoire. Engendrée par présence de perforations, celle-ci a une incidence directe sur la tenue mécanique des structures et elle est définie comme la distribution inhomogène des déformations le long du futur chemin de rupture. Le rapport de la déformation locale, observée le long de ce chemin, à une déformation de référence permet d'accéder à une "mesure" particulière de cette fragilisation. Sur la base d'observations expérimentales menées en quasi-statique sur des éprouvettes perforées ou non, le second chapitre tente de proposer un cadre théorique qui permet de mieux comprendre les fondements physiques de l'exercice de modélisation proposé. Le formalisme algébrique de Dvorak est ensuite mis en œuvre dans le troisième chapitre, pour poser les premiers jalons d'une méthode numérique multi-échelle de caractérisation du modèle de fragilisation structurale. Le développement de ce modèle, entrepris dans un premier temps dans le domaine élastique, a permis de démontrer la faisabilité d'une telle approche. Le développement de cette démarche en plasticité est ensuite tenté et discuté. Le quatrième chapitre cherche enfin à étudier l'influence de la dynamique sur le modèle de fragilisation structurale, via une étude expérimentale mettant en œuvre des matériaux sensibles ou non à la vitesse de déformation.

Page generated in 0.1168 seconds