• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 9
  • 6
  • 6
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 48
  • 48
  • 48
  • 48
  • 27
  • 16
  • 13
  • 12
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The optimal application of common control techniques to permanent magnet synchronous motors

Treharne, William January 2011 (has links)
Permanent magnet synchronous motors are finding ever increasing use in hybrid and electric vehicles. This thesis develops a new control strategy for Permanent Magnet Synchronous Motors (PMSMs) to reduce the motor and inverter losses compared to conventional control techniques. The strategy utilises three common control modes for PMSMs; brushless DC with 120°E conduction, brushless DC with 180°E conduction, and brushless AC control. The torque and power output for each control mode is determined for an example motor system using a three phase axial flux YASA motor and an IGBT inverter. The loss components for the motor and inverter are also estimated using a combination of analytical and simulation techniques and results are then validated against experimental measurements. Efficiency maps for each control mode have been used to determine an optimal mode utilisation strategy, which minimises the total system losses and maximises the available motor torque output. The proposed control strategy switches between the three control modes without interruption of motor torque to maximise the system efficiency for the instantaneous operating speed and demanded torque output. The benefits of the new strategy are demonstrated using an example vehicle over a simulated drive cycle. This yields a 10% reduction in losses compared to conventional brushless AC control.
2

Sensorless control of permanent magnet synchronous motor / Commande sans capteur d'un moteur synchrone a aimants permanents

Shah, Dhruv 31 March 2011 (has links)
Nous proposons dans ces travaux, une solution aux problèmes de longue date posés par le control sans capteur d’une machine électrique. Cette solution consiste à élaborer un contrôleur asymptotiquement stable qui régule la vitesse du moteur en mesurant uniquement les coordonnées électriques. Nous l’avons appliqué à un moteur synchrone à aimant permanent non saillant, perturbé par un couple de charge constant non connu. Le schéma proposé est un observateur non linéaire d’ordre 4, basé sur le control qui ne dépend pas d’opérations non robustes intrinsèques au système, comme l’intégration de boucle ouverte à un système dynamique et ce schéma peut être facilement intégrée en temps réel. Le contrôleur est facile à commander par l’ajustement du gain qui détermine directement le taux de convergence de la position et de la vitesse et charge le couple d’observateurs. Les simulations et les résultats expérimentaux mettent en évidences les bonnes performances ainsi que la robustesse des paramètres d’incertitudes du schéma que nous proposons. La comparaison par simulation avec un contrôleur sans capteur à champ orienté présenté récemment dans la littérature, a également été effectuée. La thèse se termine par des remarques de conclusion et des propositions de sujet de recherche s’inscrivant dans la continuité de ces travaux. / A solution to the longstanding problem of sensorless control of an electrical machine is provided in this work. That is, the construction of an asymptotically stable controller that regulates the mechanical speed of the motor, measuring only the electrical coordinates. The result is presented for a non-salient permanent magnet synchronous motor perturbed by an unknown constant load torque. The proposed scheme is a fourth order nonlinear observer-based controller that does not rely on-intrinsically nonrobust-operations like open-loop integration of the systems dynamical model nor signal differentiation, and can be easily implemented in real time. The controller is easy to commission, with the tuning gains directly determining the convergence rates of the position, speed and load torque observers. Simulation and experimental results that illustrate the good performance, as well as the robustness to parameter uncertainty, of the scheme are presented. A simulated comparison with a sensorless field-oriented controller, recently proposed in the drives literature, is also carried out. The thesis is closed with some concluding remarks and some potential research topics generated from this work.
3

Sensorless Control of Permanent-Magnet Synchronous Motors Using Online Parameter Identification Based on System Identification Theory

Ichikawa, Shinji, Tomita, Mutuwo, Doki, Shinji, Okuma, Shigeru January 2006 (has links)
No description available.
4

Sensorless Robust Sliding Mode Speed Control of Permanent Magnet Synchronous Motor

Hsu, Chih-hung 30 August 2010 (has links)
Sliding mode controllers (SMC) with time delay and a rotor position observer are designed for the sensorless speed control of permanent magnet synchronous motor (PMSM) are proposed in this paper. Based on field-oriented principle, a flux SMC is designed to achieve quick flux control. And then a speed SMC with time delay is presented and compared with PI controller in the direct torque control framework. The effectiveness of the proposed control scheme under the load disturbance and parameter uncertainties is verified by simulation results.
5

DSP-Based Sensor-less Permanent Magnet Synchronous Motor Driver With Quasi-Sine PWM for Air-Conditioner Rotary Compressor

Liu, Li-hsiang 03 August 2012 (has links)
This thesis presented a sensor-less permanent magnet synchronous motor (PMSM) driver for controlling air-conditioner rotary compressor speed. In this thesis, a quasi-sine pulse-width modulation (PWM) driving method was proposed. Furthermore, the current feedback control scheme and rotor magnet pole position detection were included. The system structure was implemented by using a digital signal processing (DSP) platform. The proposed driving scheme was compared with the square-wave driving without current feedback and six-step square-wave driving method with current feedback. Moreover, the passive and shunt semi-active power factor correction (PFC) technique were researched for the air-conditioner application. Experimental results demonstrated that the system power factor could be improved by the proposed shunt semi-active PFC method. Besides, the proposed sensor-less quasi-sine PWM driving method implemented in an air-conditioner compressor driver was capable of reducing the magnitude of rotational speed ripples, compressor vibration, and system power consumption.
6

Control strategy for a mono-inverter multi-PMSM system - Stability and efficiency

Liu, Tianyi 15 December 2017 (has links) (PDF)
During these decades, Permanent Magnet Synchronous Motor (PMSM) has become a vital part of military, industry and civil applications due to the advantages of high power density, high efficiency, high reliability and simple structure, small volume and light weight. Sometimes, multiple PMSMs are used to carry out cooperative functions. For example, the bogie of a locomotive, the flight control surface of an airplane. These PMSMs usually operates at the same speed. To reduce the volume and weight, an idea of sharing the static power conversion devices, which is called Mono-Inverter Multi-PMSM system (MIMPMSM), is raised. Although many researchers have given different controller solutions for the MIMPMSM system, most of them are not clear in the aspects of system stability and efficiency issues. This has become the biggest obstacle to the practical use of MIMPMSM. Oriented with these problems, starting with a MIMPMSM system with 2 motors, in the first step, we have tested some control strategies by an experiment to verify the feasibility and performance of them. In final, based on the experiment data, we have figured that the overconstraint problem exists in some control strategies. Then, an analysis and controller design based on steady-state model of a Mono-Inverter Dual-PMSM (MIDPMSM) system is carried out.By studying the solution existence problem of the steady-state model, we give out the design guideline to the controller structure. Combining the open-loop stability and steady-state solution, the region of controllability and stability is obtained. Lagrange Multiplier is used develop theexpression of efficiency-optimal steady-staterelated to torque and speed. The experiment has shown that the efficiency of the new controller has improved significantly. Meanwhile, we have explored the influence of parameter variation in system stability and efficiency-optimization. The variation will influence the stability region. But its influence can be eliminated by using Master- Slave strategy. On the other hand, in the aspect of efficiency optimization, the simulation results have shown that parameter mismatch, especially the permeant flux, can cause high efficiency loss. In the last step, this controller is also adapted to a MIMPMSM system with more than two motors. The simulation results demonstrate the effectiveness.
7

Modelling, simulation and analysis of low-cost direct torque control of PMSM using hall-effect sensors

Ozturk, Salih Baris 25 April 2007 (has links)
This thesis focuses on the development of a novel Direct Torque Control (DTC) scheme for permanent magnet (PM) synchronous motors (surface and interior types) in the constant torque region with the help of cost-effective hall-effect sensors. This method requires no DC-link sensing, which is a mandatory matter in the conventional DTC drives, therefore it reduces the cost of a conventional DTC of a permanent magnet (PM) synchronous motor and also removes common problems including; resistance change effect, low speed and integration drift. Conventional DTC drives require at least one DC-link voltage sensor (or two on the motor terminals) and two current sensors because of the necessary estimation of position, speed, torque, and stator flux in the stationary reference frame. Unlike the conventional DTC drive, the proposed method uses the rotor reference frame because the rotor position is provided by the three hall-effect sensors and does not require expensive voltage sensors. Moreover, the proposed algorithm takes the acceleration and deceleration of the motor and torque disturbances into account to improve the speed and torque responses. The basic theory of operation for the proposed topology is presented. A mathematical model for the proposed DTC of the PMSM topology is developed. A simulation program written in MATLAB/SIMULINK® is used to verify the basic operation (performance) of the proposed topology. The mathematical model is capable of simulating the steady-state, as well as dynamic response even under heavy load conditions (e.g. transient load torque at ramp up). It is believed that the proposed system offers a reliable and low-cost solution for the emerging market of DTC for PMSM drives. Finally the proposed drive, considering the constant torque region operation, is applied to the agitation part of a laundry washing machine (operating in constant torque region) for speed performance comparison with the current low-cost agitation cycle speed control technique used by washing machine companies around the world.
8

Developing of Robust Integral Velocity-stabilizing Controller for Permanent Magnet Synchronous Motor Driver

Lai, Chun-Ting 14 February 2012 (has links)
The objective of this thesis is to design and implement a velocity-stabilizing driver for permanent magnet synchronous motor. The research presents how to achieve high efficiency in stabilizing overall velocity for a permanent magnet synchronous motor. In order to drive the integral system, there are six steps square-wave starting device, sine-wave driver, estimation of magnetic angle, velocity feedback and current feedback control circuits designed. A test platform is built by Microchip-made dsPIC33FJ128MC804 digital signal processor used as a control core. ¡§Simulink¡¨ simulator is used during the laboratory test. The simulation results are compared with those of experiments in order to verify the achievement of excellent performance of Robust Integral Velocity-stabilizing Controller on Permanent Magnet Synchronous Motor Driver.
9

Design and Implementation of an Inverter Drive for High-Efficiency Compressor used in Air Conditioner

TSENG, WEI-CHIH 11 July 2002 (has links)
Abstract: This paper presents the results of an experimental investigation into the application of inverter-based variable speed drives to positive displacement rotary compressors. Designs and implements a DSP-microprocessor based of an inverter drive for high-efficiency compressor used in air conditioner. We control the compressor with sine PWM and V/F scheme. Permanent magnet synchronous motor has potential for energy saving in general applications on compressor drives. Permanent magnet synchronous motor drives are used for applications like compressors¡Awhere high dynamic performance is not a demand¡Asimple V/F control strategies may be sufficient to obtain the required control performance. For energy saving to find the best control strategy for an inverter drive for high efficiency compressor used in air conditioner.
10

Modelling, simulation and analysis of low-cost direct torque control of PMSM using hall-effect sensors

Ozturk, Salih Baris 25 April 2007 (has links)
This thesis focuses on the development of a novel Direct Torque Control (DTC) scheme for permanent magnet (PM) synchronous motors (surface and interior types) in the constant torque region with the help of cost-effective hall-effect sensors. This method requires no DC-link sensing, which is a mandatory matter in the conventional DTC drives, therefore it reduces the cost of a conventional DTC of a permanent magnet (PM) synchronous motor and also removes common problems including; resistance change effect, low speed and integration drift. Conventional DTC drives require at least one DC-link voltage sensor (or two on the motor terminals) and two current sensors because of the necessary estimation of position, speed, torque, and stator flux in the stationary reference frame. Unlike the conventional DTC drive, the proposed method uses the rotor reference frame because the rotor position is provided by the three hall-effect sensors and does not require expensive voltage sensors. Moreover, the proposed algorithm takes the acceleration and deceleration of the motor and torque disturbances into account to improve the speed and torque responses. The basic theory of operation for the proposed topology is presented. A mathematical model for the proposed DTC of the PMSM topology is developed. A simulation program written in MATLAB/SIMULINK® is used to verify the basic operation (performance) of the proposed topology. The mathematical model is capable of simulating the steady-state, as well as dynamic response even under heavy load conditions (e.g. transient load torque at ramp up). It is believed that the proposed system offers a reliable and low-cost solution for the emerging market of DTC for PMSM drives. Finally the proposed drive, considering the constant torque region operation, is applied to the agitation part of a laundry washing machine (operating in constant torque region) for speed performance comparison with the current low-cost agitation cycle speed control technique used by washing machine companies around the world.

Page generated in 0.1171 seconds