• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement et modélisation de l'impédance entre deux microélectrodes planes insérées dans un polymère diélectrique : vers l'application capteur et biocapteur en mode non contact pour puces microfluidiques / Development and modeling of the impedance between two planar microelectrodes inserted into a dielectric polymer : application to the biosensor and sensor in non-contact mode for microfluidic chips.

Kechadi, Mohammed 04 February 2014 (has links)
Ce travail est une étude expérimentale et de modélisation d’une configuration de puce microfluidique réalisée par photoablation laser d’un polymère diélectrique, le polyéthylène téréphtalate (PET) pour des applications en bioanalyse. C’est une configuration dite « non-contact » dans laquelle deux microélectrodes sont galvaniquement isolées dans le PET sans contact avec l’électrolyte du microcanal. La caractérisation par spectroscopie d’impédance de la réponse diélectrique du PET seul a permis de conclure que le film de PET peut être considéré comme un élément à phase constante (CPE). Cela a permis la compréhension des impédances mesurées sur puce microfluidique suivant une perturbation alternative de 100 mV dans la gamme de fréquence comprise entre 1MHz à 1Hz est effectuée pour : un microcanal vide, et un microcanal rempli avec des solutions de différentes conductivités ioniques. Les résultats obtenus ont montré une grande sensibilité des mesures d’impédances par rapport aux variations de la conductivité électrique de la solution électrolytique. Un des résultats surprenant concernant les impédances identifiées a été le comportement CPE observé avec un exposant de 0,5 que nous avons relié à l’impédance de surface rugueuse due la microstructuration en surface du PET photoablaté. Tous ces résultats expérimentaux ont été confortés par la modélisation en utilisant les circuits électriques équivalents puis par les éléments finis. Ce qui a permis de modéliser à la fois les phénomènes physiques dans le microcanal et à l’interface PET/µ-canal photoablaté. Enfin, deux applications capteur puis biocapteur ont été mises en œuvre en suivant le module de l’impédance à fréquence fixe et en fonction du temps. Comme exemple ; l’étude de la cinétique d’adsorption de la BSA sur le PET et l’étude de la cinétique d’association/ dissociation entre la BSA et l’anti-BSA. / This work is an experimental study and modeling of a microfluidic chip configuration produced by laser photoablation process on a dielectric polymer, polyethylene terephthalate (PET) for new bioanalytical development. This configuration is named "non- contact" wherein two microelectrodes are galvanically isolated in the PET without contact with the streaming electrolyte. Characterization by impedance spectroscopy of the dielectric response of PET alone has concluded that the PET film can be regarded as a constant phase element (CPE). This has permitted a best understanding of the measured impedances in a microfluidic chip under a 100 mV AC excitation in the frequency range between 1 Hz to 1 MHz, which are performed for: an empty microchannel, and a filled microchannel with electrolytes at various ionic conductivities. The results obtained showed a high sensitivity of the impedance measurements in correlation with the electrical conductivity change of the electrolyte. One of the surprising results relating to the identified impedances was a CPE behavior observed with an exponent of 0.5. This latter has been connected to the impedance due to the PET surface roughness. All these experimental results were supported by modeling using the equivalent circuits and by the finite elements. This was used to model both the physical phenomena in the microchannel and at PET interface/? - channel photoablated. Finally, both sensor and biosensor applications have been implemented in the microchip by recording the impedance module at fixed frequency with time. As examples, the investigating of the kinetics of BSA adsorption on the PET and the kinetics of association / dissociation between BSA and anti?BSA have been demonstrated.
2

Intérêt de la pulvérisation cathodique magnétron assistée par laser pour la réalisation de surfaces superhydrophobes ajustables / Laser assisted magnetron sputtering : an innovative deposition method to design tunable superhydrophobic surfaces

Becker, Claude 23 September 2013 (has links)
Ce projet de thèse entre dans le cadre de nombreux développements réalisés au sein du département Advanced Materials and Structure (AMS) du Centre de Recherche Public Henri Tudor (CRP-HT) dédiés aux activités "Surfaces & Interfaces" et consiste à développer une technique de dépôt innovante basée sur l'association de différents lasers (Nd : YAG et Excimère) et d'un système de pulvérisation cathodique magnétron dans le but d'élaborer des surfaces superhydrophobes. L'association des techniques permet de contrôler la microstructure de plusieurs substrats par ablation laser et de déposer simultanément un polymère plasma fluoré par pulvérisation magnétron à partir d'une cible PTFE. Par le biais de cette association, il est possible d'obtenir non seulement des propriétés superhydrophobes sur un grand nombre de substrats mais également de contrôler précisément les régimes de mouillages. / In this work, the development consisted in combining magnetron sputtering with a Nd-YAG or excimer lasers to provide additional properties to the deposited plasma polymer films. These both techniques are totally complementary, according to technical requirements, and provide an enhancement in the control of surface / interface chemical composition and structure leading to advanced properties. The innovative deposition technique developed in our laboratory, based on Laser-Assisted Magnetron Sputtering (LAMS), evidenced novel possibilities. lndeed, we especially highlighted the opportunity to control various polymer substrates patterning simultaneously to the plasma polymer deposition process. One of the most interesting results concerns the achievement of superhydrophobic properties on various polymer substrates with a high control in the wetting regime.

Page generated in 0.0821 seconds