• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12514
  • 1882
  • 381
  • 189
  • 174
  • 174
  • 163
  • 115
  • 84
  • 59
  • 52
  • 50
  • 47
  • 34
  • 14
  • Tagged with
  • 15095
  • 2010
  • 1390
  • 1289
  • 1244
  • 1016
  • 948
  • 915
  • 857
  • 855
  • 743
  • 733
  • 725
  • 628
  • 600
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Secado por atomización (spray dryer)

Siccha Macassi, Ana, Lock de Ugaz, Olga 25 September 2017 (has links)
No description available.
62

Evaluación de factores etiológicos de respiración bucal en niños de 4 a 10 años de edad, de la comuna de Recoleta

Bahamonde Espinoza, Paz Alejandra January 2006 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Respiración por la boca / El propósito del presente trabajo fue evaluar y determinar diferentes factores etiológicos y variables anatómicas causales de la respiración bucal, utilizando diferentes métodos diagnósticos. Este estudio fue realizado en niños respiradores bucales de 4 a 10 años de edad de la comuna de Recoleta, región Metropolitana. Se realizó la selección de la muestra mediante examen visual y diagnóstico de obstrucción nasal a través de la medición de la resistencia nasal mediante rinomanometría. En esta etapa se verificaron clínicamente las principales características del paciente respirador bucal, junto con recoger los antecedentes anamnésicos asociados a la respiración bucal. Junto con diagnosticar obstrucción nasal mediante rinomanometría en cada uno de los niños pertenecientes a la muestra, se realizó inspección nasal mediante rinoscopía a través de la cual se diagnosticaron las variables anatómicas causales de respiración bucal. A toda la muestra se le realizó la toma de una telerradiografía de perfil, con la cual se realizó la evaluación radiográfica de la presencia y grado de hipertrofia de adenoides y evaluación cefalométrica de la vía aérea determinándose el diámetro faríngeo superior e inferior. Al analizar los resultados: Se logró determinar los principales antecedentes anamnésicos asociados a la respiración bucal. Se diagnosticó obstrucción nasal en un 100% de los niños pertenecientes a la muestra. Se determinaron las principales variables anatómicas causales de respiración bucal, siendo éstas principalmente de orden nasal, destacándose la presencia de hipertrofia de cornetes y desviación septal, variables anatómicas presentes en un 77,4% de los niños pertenecientes a la muestra. Al realizar la evaluación radiográfica de la presencia y grado de hipertrofia adenoídea se observó que el 64,4% de la muestra presentó hipertrofia adenoídea, de ésta el 60% presento hipertrofia de adenoides grado 1, 30% hipertrofia de adenoides grado 2 y sólo 10% hipertrofia de adenoides grado 3. Concluyendo con estos resultados que la presencia de hipertrofia adenoidea no constituye la principal causa de respiración bucal en el presente estudio. En el estudio radiográfico y cefalométrico se determinó el valor promedio del diámetro faríngeo superior correspondiente a 6,61 mm., y del diámetro faríngeo inferior correspondiente a 14,13 mm. También se confirmaron en el presente estudio algunas de las características más representativas del paciente respirador bucal, tales como, cara alargada, cierre labial alterado y posición lingual alterada, características presentes en el 100% del los niños pertenecientes a la muestra.
63

Papel das espécies reativas do oxigênio na hipertrofia cardíaca fisiológica induzida pelo exercício

Cohen, Carolina Rodrigues January 2011 (has links)
Resumo não disponível
64

Projeto e construção de máquina de solda por atrito e análise de soldas dissimilares

Andrade, Leandro Vanz de January 2011 (has links)
A soldagem por atrito é uma alternativa aos processos convencionais de soldagem, como a solda por arco elétrico. Por ser um processo realizado no estado sólido não sofre problemas associados à fusão do material soldado e pode ser utilizado com maior facilidade em ambientes subaquáticos. A soldagem por atrito possui boas respostas também quando utilizada em soldas de materiais dissimilares. Tendo em vista a grande demanda de novas tecnologias relacionadas à exploração e produção de petróleo no Brasil, a solda por atrito é uma opção para problemas associados à correção de defeitos como trincas e porosidades em peças de grandes espessuras, como por exemplo, chapas, manilhas e ganchos. Para esses casos um processo denominado Friction Hydro Pillar Processing (FHPP) se mostra apropriado, pois possui qualidades adequadas que contrapõe as dificuldades verificadas nos reparos realizados por soldagem por arco elétrico. No Brasil as pesquisas relacionadas ao processo em questão são ainda incipientes. Tendo em vista a lacuna tecnológica e a possibilidade de reparo em campo, o presente trabalho teve como objetivo projetar, fabricar e validar um equipamento de soldagem de tamanho reduzido para facilitar a portabilidade, e que seja capaz de realizar o processo FHPP no Laboratório de Metalurgia Física (LAMEF). O projeto do equipamento foi baseado em ferramentas computacionais de CAD (Computer Aided Design) e CAE (Computer Aided Engineering) e como premissa teve a redução de custos e aproveitamento da infraestrutura laboratorial existente. Para verificar a funcionalidade do equipamento foram realizadas soldas dissimilares com os materiais SAE 4140 e BS 4360 em duas etapas. A primeira etapa teve o objetivo de verificar a operação da máquina, e a segunda etapa foi realizada com o intuito de produzir soldas sem a presença de defeitos de preenchimento. Macrografias e micrografias foram realizadas para inspecionar a região soldada, bem como foram realizados ensaios de microdureza para verificar o efeito da rotação e força de soldagem nas propriedades dos materiais soldados. O resultado do trabalho é um equipamento apto para realizar soldas dissimilares pelo processo FHPP sem defeitos de preenchimento para as juntas analisadas. / The friction welding is an alternative to conventional welding processes such as arc welding. Because it is a process performed in the solid state does not suffer from problems associated with the melt of the welded material and can be used more easily in underwater environments. The friction welding has good answers even when used for welding of dissimilar materials. Given the great demand for new technologies associated with petroleum exploration and production in Brazil, friction welding is an option for correcting problems associated with defects such as cracks and porosities in parts of large thickness, such as plates, shackles and hooks. For these cases a process called Friction Hydro Pillar Processing (FHPP) proves suitable, as it has suitable qualities that opposes the difficulties encountered in repairs performed by electric arc welding. In Brazil, research on the process are still incipient. Given the technological gap and the possibility of field repair, this study aimed to design, fabricate and validate a welding equipment for small size for easy portability, and also capable of performing the process FHPP Laboratory of Physical Metallurgy (LAMEF). The equipment design was based on computational tools for CAD (Computer Aided Design) and CAE (Computer Aided Engineering) and was premised on cost reduction and improvement of existing laboratory infrastructure. To verify the functionality of the equipment were carried out with the welding dissimilar materials SAE 4140 and BS 4360 in two stages. The first step to check the operation of the machine, and the second step in order to produce welds without filling defects. Macrographs and micrographs were taken to inspect the welded region, as well as microhardness tests were performed to determine the effect of welding speed and strength properties of welded material. The work is a result of equipment able to perform the process FHPP dissimilar welds without filling defects.
65

Complicações imediatas de pacientes puérperas histerectomizadas por sepse estudo controle : experiência de 17 anos

REMÍGIO NETO, José January 2004 (has links)
Made available in DSpace on 2014-06-12T16:27:00Z (GMT). No. of bitstreams: 2 arquivo5547_1.pdf: 1812150 bytes, checksum: fb166a95505eeeb742d0963c6a080161 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2004 / Introdução: Nos países desenvolvidos, a hemorragia é apontada como causa principal de indicação de histerectomia no ciclo grávido-puerperal. Já nos países em desenvolvimento, verifica-se que a sepse puerperal e a hemorragia são as principais causas. O objetivo do presente estudo foi analisar as complicações imediatas de pacientes histerectomizadas por sepse num Hospital Universitário. Métodos: Através de um estudo de observação, analítico do tipo coorte retrospectivo, foram avaliados dados obtidos em prontuários de 139 pacientes submetidas à histerectomia na maternidade do Hospital das Clínicas da UFPE, entre abril de 1985 e junho de 2002. De acordo com o evento desencadeador, dividiu-se em dois grupos: grupo de infecção e grupo de síndromes hemorrágicas (grupo controle). Resultados: Das 139 histerectomias realizadas, 86 (61,8%) foram por sepse (SE) e 53 (38,1%) por síndromes hemorrágicas (SH). Em ambos os grupos, predominaram as pacientes multigestas, ou seja: 87,2% no grupo por SE e 96,2% no grupo por SH; 66,3% das histerectomias em pacientes com SE e 92,5% das pacientes com SH tinham sido submetidas a parto cesariano (p=0,003 e p<0,001, respectivamente). No grupo de histerectomias por SH, houve predominância de DPPNI (p<0,001). A histerectomia total foi realizada em 97,7% das portadoras de sepse (p<0,001), enquanto apenas 45,3% das histerectomias nas SH foram totais (p<0,001). As pacientes submetidas à histerectomia por SE receberam mais transfusão sangüínea do que o grupo controle (60,5% X 45,3%), sem diferença estatística significante. Nenhuma paciente histerectomizada por SH apresentou complicações transoperatórias, entretanto 9,3% das histerectomias por sepse complicaram durante o ato cirúrgico (lesão do trato digestivo, trato urinário e distúrbio da coagulação). Em relação às complicações pós-operatórias foi observado que 31,4% das pacientes do grupo de SE apresentaram complicações decorrentes de infecção (fasciite necrotizante, insuficiência renal, choque séptico e insuficiência respiratória), não se observando estas complicações nas pacientes com síndrome hemorrágica. Conclusões: As portadoras do grupo sepse apresentaram maior incidência de abscesso (intra-abdominal e de sítio cirúrgico) em relação ao grupo controle. As histerectomias, com infecções puerperais aumentam a morbimortalidade materna no ciclo gravídico-puerperal, em relação às histerectomias por síndromes hemorrágicas
66

Estudo da extração de tripsina em sistemas de duas fases aquosas numa micro coluna

Hirose, Andre Luis Sakaguchi 30 March 2001 (has links)
Orientador: Elias Basile Tambourgi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-28T03:32:47Z (GMT). No. of bitstreams: 1 Hirose_AndreLuisSakaguchi_M.pdf: 3299228 bytes, checksum: 5d6c0fe1dc897fb8c952d6febe4c979c (MD5) Previous issue date: 2001 / Resumo: A viabilidade da produção e comercialização de substâncias obtidas por meio de processos biotecnológicos depende de técnicas de separação empregadas na purificação dos compostos desejados. Algumas características das misturas envolvidas nesses processos, tais como baixa concentração inicial, necessidade de produtos de alto grau de pureza, sensibilidade térmica e necessidade de preservar as propriedades dos compostos, fazem com que esta etapa de purificação exija um processo econômico e que seja biologicamente compatível com os produtos envolvidos. Neste sentido, a extração líquido-líquido por sistemas aquosos bifásicos se apresenta como uma técnica de separação extremamente interessante. Tendo-se em vista o desenvolvimento de extratores mais eficientes, é fundamental o estudo da hidrodinâmica e dos mecanismos de transferência de massa no interior dos extratores. Este trabalho teve como objetivo principal o estudo de uma micro-coluna agitada por campânulas perfuradas pulsantes que foi usada para extração da proteína. O sistema de agitação formado por campânulas pulsadas tem como objetivo promover uma melhor mistura dos líquidos no interior da coluna e assim, aumentar a transferência de massa. Os estudos foram realizados com sistemas de duas fases aquosas formadas por PEG (polietileno glicol) e sal (fosfato de potássio mono e bibásico). Realizou-se o estudo da extração em descontínuo, a fim de encontrar-se as concentrações de equilíbrio e os melhores sistemas de extração (concentrações de PEG e de sal e massa molecular de PEG). A melhor condição obtida foi usada na operação contínua da micro-coluna. Pôde-se concluir que a coluna de extração testada teve um rendimento superior de proteína extraída que os encontrados nos tubos de ensaio, e é adequada para utilização em sistemas biotecnológicos / Abstract: The production and commercialization suitability of substance obtained by means of biotechnological processes depend on the separation techniques used for the purification of the desired compounds. Some features of the mixtures involved in these processes, such as low initial concentration, high purity level products desired, thermal sensitivity and the need of preserving the compounds properties, require a purification step that must be economical and biologically compatible with the chemicals involved. As a matter of fact, liquid-liquid extraction by aqueous two-phase systems is presented as an outstanding separation technique. The hydrodynamics and the mass transfer mechanism in the interior of the extractors are fundamental for the development of more efficient equipment. The more goai of this work was the study of a micro-column stirred by bell-shaped meshes for the extraction of a protein. The stirring system composed by the bell-shaped meshes promotes a better mixture of the fluids in the inner side of the column and, as a result, increase the mass transfer. The aqueous two-phase systems studied were formed by PEG (polyethyiene glycol) and salts (Potassium Phosphate monobasic and dibasic). It was done bath experiments, for finding the equilibrium concentrations and the better system for the extraction (PEG and salt concentrations and polymer molecular weight). The better condition obtained was used in the continuous extraction in the micro-column. As a conclusion, the extraction apparatus tested here had a much better yield of protein recovery than the observed in the batch system, what makes it suitable for use in biotechnologicai systems / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
67

Caracterização de um novo sistema bifasico aquoso e aplicação em extração de proteinas com coluna de discos perfurados rotativos

Sarubbo, Leonie Asfora 12 August 2018 (has links)
Orientadores: Elias Basile Tambourgi, Galba Maria de Campos Takaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-12T02:15:00Z (GMT). No. of bitstreams: 1 Sarubbo_LeonieAsfora_D.pdf: 7383032 bytes, checksum: e88dd523c9d825a63da4b5835341956f (MD5) Previous issue date: 2000 / Resumo: A partição bifásica aquosa explora a capacidade exibida por soluções de dois polimeros ou de um polímero e um sal de se separarem em duas fases aquosas sempre que certas concentrações mínimas sejam excedidas. As duas fases aquosas assim formadas diferem na sua composição, sendo cada uma delas rica num dos constituintes do sistema, isto é, os dois polimeros ou o polimero e o sal concentram-se em fases distintas. Estas fases apresentam elevados teores em água, podendo em alguns casos atingir valores superiores a 90 %, constituindo ambientes suaves para moléculas e partículas biológicas. O objetivo principal deste trabalho residiu na caracterização do sistema bifásico aquoso formado por um polímero típico do Nordeste brasileiro, o polissacarídeo do cajueiro (Policaju). Sendo o elevado custo dos polímeros envolvidos o principal entrave à aplicação em grande escala da partição bifásica aquosa, este sistema apresentou a possibilidade em reduzir este custo, aumentando a competitividade da partição bifásica aquosa como processo alternativo frente aos processos tradicionais de recuperação de bioprodutos. Mostrou-se ao longo desta tese que o sistema testado apresentou propriedades fisicas (razão e tempo de separação de fases, densidade, viscosidade) e de partição características de sistemas bifásicos aquosos polímero-polímero. Após o isolamento do polissacarídeo, determinou­se o diagrama de fases e estudou-se a partição de uma proteína modelo, a albumina de soro bovino. Verificou-se o efeito exercido pelas variáveis do sistema, peso molecular do PEG (1500, 4000 / Abstract: Aqueous two-phase partition explores the possibility of solutions of two polymers or one polymer and one salt separating into two immiscible aqueous phases, when certain critical concentrations are exceeded. Each one of these aqueous phases is more concentrated in one of the phase forming chemicals. Both exhibit a high water content, in some cases as much as 90%. Due to this high water content, these byphasic systems provide a gentle environment for molecules and partic1es with biological activity. The main subject ofthis work was the characterisation of a new aqueous two-phase system based on a typical Brazilian north-westem polymer, the polysaccharide of cashew tree (Policaju). Since the cost of the phase forming polymers is the main drawback on the large scale application of aqueous two-phase partition, this system showed the possibility of decreasing this cost by increasing the applicability of biphasic partition as an alternative technique to the traditional recovery processes ofbioproducts. It is shown tOOt physical properties (phase volume ratio, time for phase separation, density, viscosity) and partition properties of the tested system are similar to others aqueous two-phase polymer-polymer systems. Afier the polysaccharide isolation, the phase diagram was determinate and the partition of a model protein, bovine serum albumin, studied. It was analysed the effect of PEG molecular weight (1500, 4000 and 8000), polymer concentration, temperature (25°C e 40°C), pH (6,0, 7,0 and 8,0) and NaCI (O,lM e 1M) addition. It was observed a displacement ofthe binodal towards lower polymer concentrations when PEG molecular weights decreased. Conversely, the variation of pH and temperature did not promote significant alterations on the binodal. It was not possible to stabilise a relation between the protein partition coeflicient and the PEG molecular weight, whi1e the increase in tie-line length and temperature and the decrease in pH promoted the decrease of the partition coeflicient. The results obtained for NaCI addition showed a tendency for the decrease ofthe partition coeflicient with the increase of salt concentration, although in some cases, the partition coefficient decreased on1y for a determina te salt concentration, depending on the system and pH. Continuous operation with aqueous two-phase systems was also tested. The beOOviour of the biphasic system PEG-Policaju was studied using a perforated rotating disc contactor (pRDC). The transfer of bovine serum albumin ftom the dispersed phase to the continuous phase was studied by using the PEG4000-Policaju system selected ftom batch extraction. The column was operated in countercurrent and in a continuous mode during 55 minutes of operatio_ where the dispersed phase was constituted by the PEG-rich phase and the continuous phase by the Policaju­rich phase. Variations in the rotation velocity (60, 140 and 220 rpm), dispersed phase velocity (2, 3 and 5 rnL/min) and discs number (03 and 04) were investigated. The performance of the equipment was characterised by the ana1ysis ofthe ftactional dispersed phase holdup, mass transfer coefticient and KA W ASE recuperation indices. The results showed an increase ofthe dispersed phase holdup, mass transfer coeflicient and recuperation indices with the increase of the rotation velocity. The same effects were observed for the increase of the dispersed phase velocity, except for the recuperation indices, which did not show a regular tendency. The increase of system composition decreased the ftactional dispersed phase holdup and the mass transfer coeflicient, although did not show a significant effect over the recuperation indices. The number discs variation did not demonstrate a significant effect upon the ftactional dispersed phase holdup, although the mass transfer coeflicient and the recuperation indices were higher for 03 discs. The ana1ysis of bovine serum albumin continuous extraction showed the higher protein transfer for the following conditions: 9%PEG4000-18%Policaju system in PRDC with 03 rotary discs with rotation velocity of 220 rpm and dispersed phase velocity of 2 mL/min. The economic ana1ysis showed that PEG-Policaju aqueous two-phase system is very competitive with other polymer-polymer systems described in the literature. This permits the development offuture researches with this new system in recovery processes / Doutorado / Sistemas de Processos Quimicos e Informatica / Doutor em Engenharia Química
68

Avaliação do desgaste por abrasão em bocais de aspersores rotativos

Sandri, Delvio 23 March 1999 (has links)
Orientador: Edson Eiji Matsura / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-25T15:13:10Z (GMT). No. of bitstreams: 1 Sandri_Delvio_M.pdf: 2644418 bytes, checksum: 0990a7bd18833621ce5e5a04d6f6e4b9 (MD5) Previous issue date: 1999 / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
69

Visão computacional : um sistema para localização de objetos poliedricos no espaço 3 D

Bellon, Olga Regina Pereira 19 December 1990 (has links)
Orientador: Clesio Luis Tozzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-13T23:49:11Z (GMT). No. of bitstreams: 1 Bellon_OlgaReginaPereira_M.pdf: 1421898 bytes, checksum: 784c9208defce208f7dd1448bd181f8b (MD5) Previous issue date: 1990 / Resumo: No presente trabalho apresenta-se um sistema para determinar a localização de objetos no espaço tridimensional, podendo o mesmo ser inserido no contexto de visão computacional. 0 trabalho foi dividido em duas etapas principais: calibração da câmera e localização do objeto no espaço 3D. Na primeira etapa é feita uma discussão acerca da teoria envolvida/ bem como são mostrados alguns resultados práticos obtidos a partir de sua implementação. Na segunda etapa é apresentado o método desenvolvido para determinar a localização do objeto a partir de informações referentes ao seu modelo geométrico utilizando-se visão monocular. Seguem-se os resultados experimentais obtidos / Abstract: It is presented a system for locating objects in a 3D space and that can be considered in the context of computer vision. The work is divided in two main parts: camera calibration, and the 3D space position of the object. In the first step a discussion on the theory of camera calibration procedure is made and some practical results are presented. In the second step it is presented the developed method for determining the object position in the space from its geometric model information and through the employement of monocular vision. The final experimental results are then analysed / Mestrado / Mestre em Engenharia Elétrica
70

Um sistema automatico de localização de objetos no espaço utilizando processamento paralelo

Barros, Fernando Carvalho de 20 December 1991 (has links)
Orientador: Clesio Luiz Tozzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T01:57:32Z (GMT). No. of bitstreams: 1 Barros_FernandoCarvalhode_M.pdf: 5841624 bytes, checksum: dd27ebf7b722af56f84e75772b484f28 (MD5) Previous issue date: 1991 / Resumo: Esta dissertação apresenta o desenvolvimento e implementação de um sistema de Visão Computacional monocular para reconhecimento e localização de objetos no espaço tri-dimensional. São apresentadas também as técnicas de processamento Paralelo MIMO e SIMO aplicadas à este sistema, visando uma redução de seu tempo de execução total. Este trabalho é multidisciplinar e pode ser inserido nos contextos de Visão Computacional,Automação Industrial, Robótica e processamento Paralelo. São apresentados resultados experimentais do sistema aplicado à Imagens reais. Procura-se mostrar como os resultados de precisão e velocidade conseguidos no sistema possibilitam sua utilização em tarefas típicas de ambientes industriais. Como um resultado prático, mostra-se que, utilizando-se 9 transputers, consegue-se que o sistema reconheça e localize, em 33ms, um paralelepípedo com complexidade de 706 pixels de borda. Mostra-se também que a precisão dos resultados obtidos situa-se dentro das especificações atualmente aceitas pela literatura especializada / Abstract: This dissertation describes the development and Implementation of a computer Vision System for the recognition and localization of objects In 3D space through monocular computer vision. This work Is multidisciplinary and It can be Inserted In the context of Computer Vision, Industrial Automaton, Robotics and Parallel Processing. It Is shown the experimental results of this system applied to real Images. And It is also shown how these results - mainly in precision and speed ¿ allows its use typical tasks in industrial environment. As a practical result, with nine tranputer5, real-time operation Is achieved for an Image of a parallelepiped with 706 edge pixels complexly. It Is also presented that the precision achieved by this system falls into the specifications accepted by the specialized literature / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0527 seconds