• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 14
  • 2
  • 2
  • 1
  • Tagged with
  • 113
  • 113
  • 81
  • 78
  • 32
  • 29
  • 28
  • 28
  • 27
  • 24
  • 24
  • 24
  • 22
  • 22
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Pós-tratamento físico-químico por flotação de efluentes de reatores anaeróbios de manta de lodo (UASB) / Physical-chemical post-treatment by flotation of effluents from upflow anaerobic sludge blanket (UASB)

Penetra, Rogério Gomes 29 May 1998 (has links)
O emprego da flotação por ar dissolvido (FAD) para o pós-tratamento de efluentes de reatores anaeróbios aparenta ser atraente considerando algumas características desse processo físico-químico. A FAD é reconhecidamente um processo de alta taxa, particularmente eficiente na remoção de material particulado em suspensão e de flocos produzidos pela coagulação química de águas residuárias. Além disso, há produção de lodo espesso e provavelmente arraste de parcela de gases e de compostos voláteis, presentes nos efluentes anaeróbios. Entretanto, a concepção de sistemas de FAD deve ser precedida por ensaios em unidades de flotação em escala de laboratório, permitindo a determinação dos principais parâmetros do processo. Neste trabalho, são apresentados e discutidos os resultados obtidos em laboratório e em instalação piloto de flotação com escoamento contínuo recebendo efluente de reator anaeróbio de manta de lodo (UASB), com 18 m3 de volume, tratando esgoto sanitário. Os ensaios em unidade em escala de laboratório foram realizados utilizando diferentes dosagens de cloreto férrico (entre 30 e 110 mg/L) ou de polímero catiônico (entre 1,0 e 16,0 mg/L), atuando como coagulantes. Além disso, foram estudadas as condições de floculação (tempo de 15 e de 25 min, e gradiente médio de velocidade de floculação entre 30 e 100 s-1) e diferentes valores de quantidade de ar fornecido ao processo (S*, entre 4,7 e 28,5 g de ar por m3 de efluente). Com a instalação piloto de FAD foram realizados apenas ensaios preliminares variando-se a taxa de aplicação superficial (140 e 210 m3/m2/d) para diferentes valores de S* (14,8 a 29,5 g de ar por m3 de efluente). Com o emprego de dosagem de 65 mg/L de cloreto férrico, de tempo de 15 min e gradiente médio de velocidade de floculação de 80 s-1 e de 19 g de ar por m3 de efluente, foram observados excelentes resultados em laboratório, com elevadas remoções de DQO (89%), de fosfato total (96%), de sólidos suspensos totais (96%), de turbidez (98%), de cor aparente (91%), de sulfetos (não detectado) e NTK (47%). Considerando o sistema UASB e FAD, nos testes em laboratório, foram observadas remoções globais de 97,7% de DQO, de 98,0% de fosfato total, de 98,9% de SST, de 99,5% de turbidez, de 97,8% de cor aparente e de 59,0% de NTK. Nos ensaios com a instalação piloto de FAD, o sistema apresentou remoções de 93,6% de DQO, de 87,1% de SST, de 90% de sulfetos e de 30% de NTK. / The utilization of dissolved-air flotation (DAF) for the post-treatment of effluents from anaerobic reactors seems to be attractive considering some characteristics features of such a physical-chemical process. DAF is known to be a high-rate process particularly efficient for the removal of suspended particles and flocs produced by the chemical coagulation of wastewaters. Moreover, it produces a thick sludge and probably promotes the stripping of gases and volatile compounds present in anaerobic effluents. However, the design of DAF systems has to be preceeded by assays in lab-scale units permiting to establish the main process parameters. The results obtained from a lab-scale unit receiving effluent of a 18 m3 upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage are presented and discussed. The assays were performed firstly in a lab-scale unit, using ferric chloride (from 30 to 110 mg/L) or cationic polymer (from 1.0 to 16.0 mg/L) as coagulant under different concentrations. In order to obtain proper conditions for flocculation time (t) was fixed at 15 and 25 min and velocity gradient (G) was ranged form 30 to 100 s-1. The required quantity of air (S*) was ranged from 4.7 to 28.5 g of air per m3 of wastewater. Using a FAD pilot plant, only preliminary assays were performed, using two surface load rate values (140 e 210 m3/m2/d) and different S* values (from 14.8 to 29.5 g of air per m3 of wastewater). Using a lab-scale unit, 65 mg/L FeCl3, 15 min for t, 80 s-1 for G and 19.0 g of air per m3 of wastewater for S*, the removal efficiencies obtained were 89% for COD, 96% for total phosphate, 96% for suspended solids, 98% for turbidity, 91% for apparent color, 47% for TKN and sulphites were not detected in final effluent. For the UASB-DAF systems, still in labscale unit, global efficiencies were 97.7% for COD, 98.0% for total phosphate, 98.9% for suspended solids, 99.5% for turbidity, 97.8% for apparent color and 59.0% for TKN. Using DAF pilot plant, system global efficiencies were 93.6% for COD, 87.1% for suspended solids, 90% for sulphites and 30% for TKN.
72

Avaliação de um sistema piloto composto de reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação no tratamento de esgotos sanitários com elevada contribuição de despejos industriais. / Treatment of sewage containing expressive amount of industrial effluents in a pilot plant system consisted of an UASB reactor followed by an aerated lagoon and a settling pond.

Romero De La Iglesia, Manuel 21 December 2004 (has links)
Este trabalho experimental apresenta os resultados da avaliação do desempenho de uma instalação piloto, composta por reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação, no tratamento dos esgotos afluente a ETE - Jundiaí, que contém elevada contribuição de despejos industriais. O reator UASB e a lagoa de decantação tem volume útil de 3,0 m3 e 2,0 m3, respectivamente. O volume da lagoa aerada aeróbia é variável entre 7,2 m3 e 21,6 m3 de modo a permitir variar o tempo de detenção hidráulica. O sistema foi avaliado em termos da eficiência de remoção de DQO, DBO5, sólidos suspensos, nitrogênio total, fósforo total e cor verdadeira para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,0 e 3,5 dias mantendo, tanto no reator UASB quanto, na lagoa de decantação o tempo de detenção constante em 8,0 horas e 1,8 dia, respectivamente. O sistema completo apresentou uma eficiência de remoção de DQO total entre 85% e 87%, de DBO5 total entre 92% e 96%, de SST entre 81% e 87%, de SSV entre 80 e 88%, de nitrogênio total entre 55 e 57%, de fósforo total entre 60 e 70% e de cor verdadeira entre 50 e 60%, para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,5 e 3,5 dias. O reator UASB foi responsável pela remoção de cerca de 50% da DQO total, 60% da DBO5 total e 40% dos SST do afluente, operando em média com um tempo de detenção hidráulica de 8,0 horas. As eficiências alcançadas no sistema completo produziram um efluente final com uma concentração de DQO total entre 170 e 230 mg/L, de DBO5 total entre 30 e 60 mg/L, de SST entre 30 e 45 mg/L, de SSV entre 24 e 40 mg/L, de nitrogênio total entre 24 e 28 mg NH3/L, de fósforo total entre 3,5 e 5,5 mg P/L e de cor verdadeira entre 375 e 600 mg Pt/L. O sistema pesquisado mostrou-se uma alternativa viável para o tratamento do esgoto afluente à ETE - Jundiaí e poderá resultar em redução da área e em menor consumo de energia que os hoje necessários na ETE - Jundiaí, que emprega um sistema composto por lagoas aeradas aeróbias seguidas de lagoas de decantação. / This experimental investigation was carried out in order to evaluate the performance of a pilot plant, composed of an UASB reactor followed by an aerated lagoon and a settling pond, treating the Wastewater Treatment Plant of Jundiaí city (WWTPJ) influent sewage, which contains in its composition an expressive amount of industrial effluents. The UASB reactor and settling pond have an useful volume of 3.0 m3 and 2.0 m3, respectively. The aerated lagoon volume is variable from 7.2 m3 to 21.6 m3 to make possible the hydraulic retention time variation. The COD, BOD5, suspended solids, total nitrogen, total phosphorus and true colour removal efficiencies of the system were evaluated when the aerated lagoon hydraulic retention time varied from 1.0 to 3.5 days and in the UASB reactor and settling pond was mainteined constant at 8.0 hours and 1.8 day, respectively. The range of removal efficiencies obtained in the system are: 85 - 87% for total COD, 92 - 96% for total BOD5, 81 - 87% for TSS, 80 - 88% for VSS, 55 - 57% for total nitrogen, 60 - 70% for total phosphorus, and 50 - 60% for true color, when the aerated lagoon hydraulic retention time varied from 1.5 to 3.5 days. The UASB reactor operating at 8.0 hours hydraulic retention time removes almost 50% of total COD, 60% of total BOD5 and 40% of TSS from the influent contents. The system performance lead to a final effluent with a total COD, total BOD5, TSS, VSS, total nitrogen, total phosphorus, and true color concentrations in the range of: 170 - 230 mg/L, 30 - 60 mg/L and 30 - 45 mg/L, 24 - 40 mg/L, 24 - 28 mg N/L, 3,5 - 5,5 mg P/L and 375 - 600 mg Pt/L, respectively. The system studied is a practicable alternative for the treatment of the WWTPJ influent sewage, probably with less area and energy saving whem compared to the WWTPJ current needs, which uses a system composed by an aerated lagoon followed by a settling pond
73

Avaliação de um sistema piloto composto de reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação no tratamento de esgotos sanitários com elevada contribuição de despejos industriais. / Treatment of sewage containing expressive amount of industrial effluents in a pilot plant system consisted of an UASB reactor followed by an aerated lagoon and a settling pond.

Manuel Romero De La Iglesia 21 December 2004 (has links)
Este trabalho experimental apresenta os resultados da avaliação do desempenho de uma instalação piloto, composta por reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação, no tratamento dos esgotos afluente a ETE - Jundiaí, que contém elevada contribuição de despejos industriais. O reator UASB e a lagoa de decantação tem volume útil de 3,0 m3 e 2,0 m3, respectivamente. O volume da lagoa aerada aeróbia é variável entre 7,2 m3 e 21,6 m3 de modo a permitir variar o tempo de detenção hidráulica. O sistema foi avaliado em termos da eficiência de remoção de DQO, DBO5, sólidos suspensos, nitrogênio total, fósforo total e cor verdadeira para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,0 e 3,5 dias mantendo, tanto no reator UASB quanto, na lagoa de decantação o tempo de detenção constante em 8,0 horas e 1,8 dia, respectivamente. O sistema completo apresentou uma eficiência de remoção de DQO total entre 85% e 87%, de DBO5 total entre 92% e 96%, de SST entre 81% e 87%, de SSV entre 80 e 88%, de nitrogênio total entre 55 e 57%, de fósforo total entre 60 e 70% e de cor verdadeira entre 50 e 60%, para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,5 e 3,5 dias. O reator UASB foi responsável pela remoção de cerca de 50% da DQO total, 60% da DBO5 total e 40% dos SST do afluente, operando em média com um tempo de detenção hidráulica de 8,0 horas. As eficiências alcançadas no sistema completo produziram um efluente final com uma concentração de DQO total entre 170 e 230 mg/L, de DBO5 total entre 30 e 60 mg/L, de SST entre 30 e 45 mg/L, de SSV entre 24 e 40 mg/L, de nitrogênio total entre 24 e 28 mg NH3/L, de fósforo total entre 3,5 e 5,5 mg P/L e de cor verdadeira entre 375 e 600 mg Pt/L. O sistema pesquisado mostrou-se uma alternativa viável para o tratamento do esgoto afluente à ETE - Jundiaí e poderá resultar em redução da área e em menor consumo de energia que os hoje necessários na ETE - Jundiaí, que emprega um sistema composto por lagoas aeradas aeróbias seguidas de lagoas de decantação. / This experimental investigation was carried out in order to evaluate the performance of a pilot plant, composed of an UASB reactor followed by an aerated lagoon and a settling pond, treating the Wastewater Treatment Plant of Jundiaí city (WWTPJ) influent sewage, which contains in its composition an expressive amount of industrial effluents. The UASB reactor and settling pond have an useful volume of 3.0 m3 and 2.0 m3, respectively. The aerated lagoon volume is variable from 7.2 m3 to 21.6 m3 to make possible the hydraulic retention time variation. The COD, BOD5, suspended solids, total nitrogen, total phosphorus and true colour removal efficiencies of the system were evaluated when the aerated lagoon hydraulic retention time varied from 1.0 to 3.5 days and in the UASB reactor and settling pond was mainteined constant at 8.0 hours and 1.8 day, respectively. The range of removal efficiencies obtained in the system are: 85 - 87% for total COD, 92 - 96% for total BOD5, 81 - 87% for TSS, 80 - 88% for VSS, 55 - 57% for total nitrogen, 60 - 70% for total phosphorus, and 50 - 60% for true color, when the aerated lagoon hydraulic retention time varied from 1.5 to 3.5 days. The UASB reactor operating at 8.0 hours hydraulic retention time removes almost 50% of total COD, 60% of total BOD5 and 40% of TSS from the influent contents. The system performance lead to a final effluent with a total COD, total BOD5, TSS, VSS, total nitrogen, total phosphorus, and true color concentrations in the range of: 170 - 230 mg/L, 30 - 60 mg/L and 30 - 45 mg/L, 24 - 40 mg/L, 24 - 28 mg N/L, 3,5 - 5,5 mg P/L and 375 - 600 mg Pt/L, respectively. The system studied is a practicable alternative for the treatment of the WWTPJ influent sewage, probably with less area and energy saving whem compared to the WWTPJ current needs, which uses a system composed by an aerated lagoon followed by a settling pond
74

ANÁLISE DA VIABILIDADE DE FILTRO ANAERÓBIO DE CHICANAS NO PÓS-TRATAMENTO DE ESGOTOS SANITÁRIOS

Silva, Vanessa Farias da 22 December 2005 (has links)
Made available in DSpace on 2015-09-25T12:23:30Z (GMT). No. of bitstreams: 1 VANESSA F SILVA.pdf: 1400231 bytes, checksum: fb9f24d41beb924c130d174f918f19f8 (MD5) Previous issue date: 2005-12-22 / The objective of this thesis is to evaluate the performance of anaerobic filter with baffles (FAC) for the post treatment of anaerobic effluent and using rings cut from PET bottles as filling medium. The experiment was carried out in three phases characterized by the hydraulic retention times of 7, 9 and 10 days, respectively. The analysis of the UASB and FAC effluents was carried out weekly to evaluate the removal efficiency of organic material expressed as BOD5 e COD, solids and its different fractions, nutrients (nitrogen and phosphorus) and indicators of faecal contamination (thermotolerant Coliforms). The results showed that there were no significant differences between the FAC effluent during the three phases with respect to organic material and suspended solids (at 5% significance level), but there were differences in the electric conductivity, nitrogen and thermotolerant Coliforms. The FAC presented good performance of organic material removal (65% for COD and 64% for BOD5 during the first phase) and suspended solids (81% for TSS and 83% for VSS during the first phase). Thus it can be noted that the FAC presented good post treatment efficiency of anaerobic effluents, resulting in clarified effluent with low concentrations of organic material (12mg BOD5.L-1), suspended solids (<10 mg TSS. L-1) and turbidity (<10 UNT). With respect to sanitary quality the produced effluent had concentrations of thermotolerant in the range of 103 to 104 UFC.100 mL-1, hence above the standards established by the WHO (1989) for utilization in irrigation without restrictions. / O presente trabalho teve como objetivo avaliar o desempenho de filtro anaeróbio de chicanas (FAC) no pós-tratamento de efluente anaeróbio, usando garrafas PET como material de enchimento. O experimento foi realizado em três fases, delimitado pelos três tempos de detenção hidráulicas, 7, 9 e 10 dias, respectivamente. As análises dos efluentes do reator UASB e do FAC foram realizadas semanalmente, averiguando a remoção de matéria orgânica na forma de DBO5 e DQO, sólidos e suas frações, nutrientes (nitrogênio e fósforo) e indicadores de contaminação fecal (coliformes termotolerantes). Os resultados mostraram que não ocorreram diferenças significativas no efluente do FAC entre as três fases, em relação a matéria orgânica e sólidos (ao nível de 5%), mas houve diferença quanto a condutividade elétrica, nitrogênio e coliformes termotolerantes. O FAC apresentou bom desempenho quanto à remoção de matéria orgânica (65% para DQO e 64% para DBO5 durante a 1ª fase) e sólidos suspensos (81% para SST e 83% para SSV durante a 1ª fase). Diante desses resultados, observa-se que o FAC apresentou boa eficiência no pós-tratamento de efluente anaeróbio resultando em um efluente clarificado com baixas concentrações de matéria orgânica (12mg DBO5.L-1), sólidos suspensos (<10 mg SST. L-1) e turbidez (<10 UNT). Com relação à qualidade sanitária, o efluente produzido apresentava concentrações de coliformes termotolerantes variando de 103 a 104 UFC.100 mL-1, portanto valores acima dos padrões estabelecidos pelo OMS (1989) para ser utilizado em irrigação irrestrita.
75

AvaliaÃÃo de Sistemas de PÃs-Tratamento de Lixiviados por Processos BiolÃgicos e Oxidativos AvanÃados e o Desenvolvimento AnalÃtico para DetecÃÃo e QuantificaÃÃo de Compostos Recalcitrantes

ElisÃngela Maria Rodrigues Rocha 27 April 2010 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Este trabalho avaliou a viabilidade dos processos biolÃgicos aerÃbios e oxidativos avanÃados (POAs) como pÃs-tratamento de lixiviados antigos provenientes de lagoas de estabilizaÃÃo em sÃrie. Paralelamente, desenvolveu-se uma metodologia analÃtica para detecÃÃo e quantificaÃÃo de compostos aromÃticos, organoclorados, Ãsteres ftalatos e hormÃnios, considerados como compostos recalcitrantes e raramente investigados em lixiviados tratados, principalmente nas ETEs localizadas no estado do CearÃ. Inicialmente foi realizada uma caracterizaÃÃo fÃsico-quÃmica e especiaÃÃo de metais sendo verificado que DQO e amÃnia estavam acima dos limites permitidos pelas normas ambientais, bem como alguns metais. No desenvolvimento da metodologia analÃtica para detecÃÃo e quantificaÃÃo por GC/FID verificou-se que a extraÃÃo em fase sÃlida empregando C-18 foi a melhor tÃcnica para extraÃÃo e prÃ-concentraÃÃo dos compostos recalcitrantes e que os melhores resultados de recuperaÃÃo dos compostos foram obtidos para os compostos aromÃticos e Ãsteres ftalatos. Nos experimentos de pÃs-tratamento empregando os reatores biolÃgicos, reator aerado submerso (RAS) e reator em batelada seqÃencial (RBS), todos foram eficientes na nitrificaÃÃo do lixiviado com percentuais superiores a 90% de remoÃÃo da amÃnia, contudo, nÃo foram eficazes na remoÃÃo de fÃsforo. Em termos de remoÃÃo dos compostos recalcitrantes, o RBS apresentou melhores resultados em relaÃÃo ao RAS para os compostos aromÃticos e Ãsteres ftalatos. No processo de oxidaÃÃo avanÃada UV/H2O2 foi obtida remoÃÃes de DQO, turbidez e descoloraÃÃo da amostra superior a 90%, a partir de 120 minutos de reaÃÃo, em sistema de batelada com recirculaÃÃo. O sistema UV/H2O2 foi eficiente na remoÃÃo dos compostos aromÃticos e, eficaz para os Ãsteres ftalatos benzil-butilftalato (BBP) e dietil-hexilftalato (DEHP) com 100% de remoÃÃo. O processo foto-Fenton com radiaÃÃo solar estudado com o lixiviado de Portugal apresentou-se como uma excelente opÃÃo no pÃs-tratamento do lixiviado em relaÃÃo aos outros sistemas estudados (UV/H2O2 e TiO2/UV) devido a mineralizaÃÃo dos compostos orgÃnicos terem sido de aproximadamente 80% de remoÃÃo do carbono orgÃnico dissolvido (COD), reduÃÃo da aromaticidade e descoloraÃÃo, alÃm de aumentar a biodegradabilidade do lixiviado. A concentraÃÃo Ãtima de ferro para o lixiviado estudado foi de 60 mg L-1 Fe+2, com consumo de H2O2 de 310, 6 mM e aproximadamente 110 kJ L-1 de energia acumulada., mas nÃo foi eficiente na remoÃÃo do Ãster dietil-hexil ftalato (DEHP), um dos principais ftalatos considerado como interferente endÃcrino. Os processos UV/H2O2 e TiO2/UV utilizando energia solar nÃo foram favorÃveis devido a reaÃÃo ser mais lenta em comparaÃÃo com o processo foto-Fenton e terem sido obtidos baixos valores de remoÃÃo de COD, indicando baixa mineralizaÃÃo dos compostos orgÃnicos presentes no lixiviado. / This work assessed the feasibility of using biological and advanced oxidation processes (AOP) as post-treatments for old leachate from stabilization ponds in series. Additionally, an analytical methodology for detection and quantification of aromatic compounds, organochlorides, phthalate esters and hormones, was developed. These compounds are considered as recalcitrant and rarely investigated in treated leachates, mainly in wastewater treatment plants located in the state of CearÃ. Initially, a physico-chemical characterization and a metal speciation was carried out, from which it was verified that COD and ammonia were above the limits permitted by environmental legislation, and also some metals. In the development of the analytical methodology for detection and quantification by GC/FID, the solid phase extraction using C-18 was the best technique for extraction and pre-concentration of the recalcitrant compounds and the best results in terms of recuperation were achieved for the aromatic compounds and phthalate esters. In the post-treatment experiments using biological reactors, aerated submerged reactor (ASR) and sequential batch reactor (SBR), both were efficient in the leachate nitrification reaching ammonia removal efficiencies above 90%. However, they were not efficient on phosphorus removal. In terms of recalcitrant compounds removal, SBR presented better results when compared with ASR for the aromatic compounds and phthalate esters. The advanced oxidation process UV/H2O2 reached turbidity and COD removal and decolourisation efficiencies above 90% from a reaction time of 120 minutes by using recirculation batch mode. The UV/H2O2 system was efficient in the removal of aromatic compounds and the phthalate esters benzyl butyl phthalate (BBP) and diethyl hexyl phthalate (DEHP), achieving 100% removal. The photo-Fenton process with solar radiation assessed with the leachate from Portugal showed to be an excellent option for the leachate post-treatment when compared to the other systems studied (UV/H2O2 and TiO2/UV). Mineralization of organic compounds has reached approximately 80% reduction of dissolved organic carbon (DOC), beside aromaticity and decolourisation reductions and increasing leachate biodegradability. The optimal iron concentration for the leachate studied was 60 mg L-1 Fe+2, with H2O2 consumption of 310.6 mM and approximately 110 kJ L-1 of accumulated energy. However, it was not efficient in the removal the ester DEHP, one of most important phthalates, which is considered an endocrine disruptor. The UV/H2O2 and TiO2/UV processes using solar energy were slower than the photo-Fenton process and low COD removals were achieved, which indicated low mineralization of the organic compounds present in the leachate.
76

Otimização da remoção biológica de nitrogênio de efluente de abate e industrialização de aves usando reator em bateladas sequenciais

Mees, Juliana Bortoli Rodrigues 01 February 2010 (has links)
Made available in DSpace on 2017-07-10T19:24:42Z (GMT). No. of bitstreams: 1 Juliana Bortoli Rodrigues Mees.pdf: 1255432 bytes, checksum: bf00dbf45cce28fdbe504091e6363048 (MD5) Previous issue date: 2010-02-01 / Agro-industries stand out as large polluters in Brazil, particularly because of the large amounts of waste rich in organic substances, nutrients (especially nitrogen and phosphorus), solids, oils and greases. In this category, slaughterhouses and bird cold storage processing plants are known for their high pollution potential. The removal of nitrogen from wastewater is usually accomplished using biological conventional processes, by nitrification plus denitrification, involving aerobic and anaerobic phases that are generally carried out in separate reactors or by different aeration intervals. The sequencing batch reactor (SBR) uses multiple steps in the same reactor, which include filling, reaction, settling, withdrawal and idling. This study aimed to investigate how carbon:nitrogen ratios (COD/NO2 --N+NO3 --N) 3, 6 and 9, adjusted by manipueira (wastewater from cassava industry) and cycle time (CT) of 8,12 and 16 hours affects the nitrogen and organic matter removal from poultry wastewater, operating a sequencing batch reactor containing suspended biomass, in two different conditions: condition I, with the reaction step consisted by aerobic/anoxic phases and condition II, anoxic I/aerobic/anoxic II phases. It was also intended to optimize and validate the process of nitrogen removal in this type of effluent, to evaluate the reactor stability using Shewhart control charts for individual measures, and to study the kinetics behavior of organic matter (COD) and nitrogen (NH4 +-N, NO2 --N and NO3 --N) degradation. The conditions I and II were evaluated through factorial planning (32) and, in order to optimize the conditions obtained with the initial factorial design, it was used a central composite rotational design (CCRD) with four assays in levels -1 and +1, four assays on the axial points levels (-1.414 and +1.414) and five replicates at the central point (0). The nitrification process performance was evaluated by the efficiency of ammonia nitrogen removal (%), the pre-denitrification and denitrification processes by the efficiencies of nitrite and nitrate removal (%) and the whole process by total inorganic nitrogen removal (%). During the nitrification and denitrification processes, parameters like temperature, pH, alkalinity, redox potential, salinity and conductivity were monitored. The highest removal percentages of total inorganic nitrogen were obtained, for conditions I and II, at the cycle time range between 12 and 16 hours and the C/N ratio of 3 to 6, which showed average efficiencies of 80.76 and 85.57% in condition I, and 90.99 and 91.09% in condition II, respectively. Although the condition II obtained a higher removal percentage of total inorganic nitrogen, only condition I presented a regression statistically significant and predictive, with Fcal/Ftab values higher than 4 for all steps involved in nitrogen removal. Optimizing the condition I, the highest percentages of nitrogen removal were achieved with the cycle time of 16 hours and C/N ratio of 6, validated experimentally, achieving an overall removal of inorganic nitrogen of 85.83±0.87 %. Evaluating the reactor stability, the results of the 20 trials carried out with optimum conditions showed a total inorganic nitrogen average removal of 84.32±1.59% (CV=1.89%) and organic matter removal of 53.65±8.48% (CV=15.81%), considering the complete process (nitrification plus denitrification), being the process under statistical control. The evaluation of the kinetic behavior of nitrogen conversion indicated a possible reduction in the cycle time of the anoxic phase, since percentages of NO2 --N and NO3 -N removal higher than 90% were obtained in just one hour of denitrification. / As agroindústrias destacam-se como grandes poluidoras, devido, especialmente, às elevadas vazões com que geram seus efluentes ricos em carga orgânica, nutrientes (principalmente nitrogênio e fósforo), sólidos, óleos e graxas. Neste setor enquadram-se os abatedouros e frigoríficos de aves. A remoção de nitrogênio das águas residuárias é geralmente realizada por processos biológicos convencionais, que contemplam a nitrificação seguida da desnitrificação, envolvendo fases aeróbias e anaeróbias, separadas em diferentes reatores ou por diferentes intervalos de aeração. Os reatores em bateladas sequenciais (RBS) utilizam múltiplas etapas no mesmo reator, que incluem enchimento, reação, sedimentação, descarte e repouso. Esta pesquisa teve por objetivo investigar os efeitos da relação carbono:nitrogênio (DQO/N-NO2 -+N-NO3 -); 3, 6 e 9, ajustada pela adição de manipueira e do tempo de ciclo (TC); 8, 12 e 16 horas, na remoção de nitrogênio e matéria orgânica de efluente avícola, operando um RBS, em escala de bancada, com biomassa em suspensão em duas condições distintas, condição I com a etapa de reação composta pelas fases aeróbia/anóxica e condição II anóxica I/aeróbia/anóxica II. Objetivouse também, otimizar e validar o processo de remoção de nitrogênio, avaliar a estabilidade do reator através de gráficos de controle Shewhart para medidas individuais e, efetuar o estudo do comportamento cinético de degradação da matéria orgânica (DQO) e nitrogenada (N-NH4 +, N-NO2 - e N-NO3 -). Para avaliação das condições I e II elaborou-se um planejamento fatorial completo (32) e para otimização das condições obtidas com o planejamento fatorial inicial, utilizou-se um delineamento composto central rotacional (DCCR), com quatro ensaios nos níveis -1 e +1, quatro ensaios nos níveis dos pontos axiais (-1,414 e +1,414) e cinco repetições no ponto central (0). Avaliou-se o desempenho da nitrificação através da eficiência de remoção do nitrogênio amoniacal (%), o desempenho da pré-desnitrificação e desnitrificação através da eficiência de remoção de nitrito e nitrato (%) e a eficiência do processo completo pela remoção de nitrogênio inorgânico total (%), além do monitoramento de parâmetros, como a temperatura, pH, alcalinidade, potencial redox, salinidade e condutividade elétrica. Os maiores percentuais de remoção de nitrogênio inorgânico total foram obtidos, para ambas as condições I e II, usando as faixas de TC de 12 a 16 horas e relação C/N de 3 a 6, com valores médios de eficiências de 80,76 e 85,57% na condição I e, 90,99 e 91,09% na condição II, respectivamente. Apesar da condição II ter apresentado um percentual de remoção de nitrogênio inorgânico total superior, apenas a condição I apresentou uma regressão estatisticamente significativa e preditiva, com valores de Fcal/Ftab superiores a 4, para todas as etapas envolvidas na remoção de nitrogênio. Otimizando-se a condição I, os maiores percentuais de remoção de nitrogênio foram alcançados com o tempo de ciclo de 16h e a relação C/N de 6, validados experimentalmente, alcançando uma remoção global de nitrogênio inorgânico de 85,83±0,87%. Na avaliação da estabilidade do reator, os resultados dos 20 ensaios realizados com a condição ótima apontaram valores médios de remoção de nitrogênio inorgânico total de 84,32±1,59% (CV=1,89%) e, de matéria orgânica de 53,65±8,48% (CV= 15,81%), no processo completo (nitrificaçãodesnitrificação), estando o processo sob controle estatístico. A avaliação do comportamento cinético de conversão do nitrogênio indicou uma possível redução no tempo de ciclo da fase anóxica, uma vez que foram alcançadas remoções de N-NO2 -e N-NO3 - superiores a 90%, em apenas uma hora de desnitrificação.
77

Efeito da aeração e do tempo de ciclo na remoção biológica de nitrogênio de efluente da indústria avícola / Effect of aeration and cycle time in biological nitrogen removal of wastewater from poultry slaughterhouse

Lopes, Carla Limberger 01 July 2011 (has links)
Made available in DSpace on 2017-07-10T19:24:51Z (GMT). No. of bitstreams: 1 Carla Limberger Lopes_protegido.pdf: 1510356 bytes, checksum: 558cae02592904f9e836e71f9aa4036f (MD5) Previous issue date: 2011-07-01 / This study aimed to evaluate the influence of air flow (0.25, 0.50 and 0.75 L.min-1.Lreator-1) and cycle time (11.35 h, 15.15 h and 18.25 h) in the performance of a sequencing batch reactor (SBR) to promote nitrification and denitrification of wastewater from slaughterhouse's poultry and refrigerator. The operation included the steps of feeding, aerobic and anoxic reaction, sedimentation, discharge and rest. SBR was operated on a laboratory scale with a working volume of 4 L, keeping 25% of biomass retained in the reactor as an inoculum for the next batch. The "manipueira" was added as a carbon source at the beginning of anoxic phase in order to keep the C: N ratio between 5 and 6. During this process, parameters monitored included: pH, alkalinity, dissolved oxygen and temperature. It was developed a factorial design (22) with five repetitions at the central point to check the influence of the response variable removal of total inorganic nitrogen (NH4+-N + NO2--N + NO3--N) in the whole process (%). Data were analyzed with 95% confidence, and experimentally, a higher removal of total inorganic nitrogen (85.75%) on average was observed when using air flow of 0.50 L.min-1.Lreator-1 in time cycle of 15.15 h. However, there was no statistically significant factor for the air flow, and during the progress of study, this variable was kept stable at 0.25 L.min-1.Lreator-1 while the cycle time was gradually increased until efficiency in the removal of constant nitrogen could be observed, which occurred at time 15.1 h with 92.78% in removal efficiency of total inorganic nitrogen. / Esta pesquisa teve por objetivo avaliar a influência da vazão de ar (0,25, 0,50 e 0,75 L.min-1.Lreator-1) e do tempo de ciclo (11,35 h, 15,15 h e 18,25 h) no desempenho de um reator em bateladas sequenciais (RBS), em promover a nitrificação e a desnitrificação de água residuária de abatedouro e frigorífico de aves. A operação contemplou as etapas de alimentação, reação aerada e anóxica, sedimentação, descarte e repouso. O RBS foi operado em escala de laboratório com volume útil de 4 L, mantendo-se 25% da biomassa no reator, como inóculo para a próxima batelada. A manipueira foi adicionada como fonte de carbono no início da fase anóxica, de modo a manter a relação C:N entre 5 e 6. Durante o processo foram monitorados os parâmetros pH, alcalinidade, oxigênio dissolvido e temperatura. Elaborou-se um planejamento fatorial (22) com cinco repetições no ponto central para verificar a influência dos fatores na variável resposta remoção de nitrogênio inorgânico total (N-NH4++N-NO2-+N-NO3-) no processo completo (%). Os dados foram analisados com 95% de confiança e, experimentalmente, a maior remoção de nitrogênio inorgânico total (85,75%) em média foi observada quando se utilizou vazão ar de 0,50 L.min-1.Lreator-1, no tempo de ciclo de 15,15 h. Entretanto, não foi verificada significância estatística para o fator vazão de ar e, na continuidade do estudo, esta variável foi mantida estável em 0,25 L.min-1.Lreator-1, enquanto o tempo de ciclo foi gradativamente elevado até ser observada eficiência de remoção de nitrogênio constante, o que foi verificado a partir do tempo de 15,1 h com 92,78% na eficiência de remoção de nitrogênio inorgânico total.
78

Biofiltro aerado submerso aplicado ao pós-tratamento de efluente de reator UASB, sob condições hidráulicas desfavoráveis: estudo em escala real / Submerged aerated biofilter used for post-treatment of the effluent of an UASB reactor, under unfavorable hydraulic conditions: full-scale study

Thais Gorga de Godoy 14 September 2007 (has links)
Esta pesquisa avaliou a eficiência do biofiltro aerado submerso empregado no pós-tratamento do efluente do reator anaeróbio de manta de lodo (UASB), em escala real, localizado na ETE Água Vermelha em São Carlos, SP, sob condições hidráulicas desfavoráveis. Estudou-se a remoção de matéria orgânica e de sólidos, a possibilidade de remoção de nitrogênio e fósforo e também as características da biomassa aderida ao meio suporte. O estudo foi desenvolvido em duas fases, uma sem a adição de inóculo (fase I) e outra com inoculação (fase II). Na fase I foi aplicada vazão de 380 m³/dia, cargas orgânicas volumétricas (COV) de 3kgDQO/m³.dia com carga hidráulica (CH) de 8 m³/m².dia e tempo de detenção hidráulica (TDH) de 170 minutos. Nesta fase o biofiltro alcançou eficiências médias de 40% na remoção de matéria orgânica (DQO) e de 35% para os SST. Na segunda fase foram aplicadas vazões de 500 m³/dia, COV de 4 kg DQO/ m³.dia com CH de 11 m³/ m².dia e TDH de 130 minutos. O BAS apresentou eficiências médias de remoção de DQO, \'COT IND.F\' e SST de 36%, 60% e 30%, respectivamente, para a fase II. A conversão de nitrito a nitrato foi considerada desprezível, podendo ser atribuída ao alto valor de DQO afluente ao BAS, à ocorrência de nitrificação e desnitrificação no mesmo biofilme e à distribuição ineficiente de ar no interior do reator. O biofiltro não apresentou bons resultados quanto à remoção de fósforo durante a pesquisa. O estudo permitiu concluir que o BAS apresentou um desempenho satisfatório como unidade de pós-tratamento de reator UASB na fase de partida, mesmo sendo submetido a altas cargas hidráulicas e orgânicas. Constatou-se, portanto, que o emprego do biofiltro aerado submerso apresenta-se como uma alternativa vantajosa para o pós-tratamento do efluente de reatores anaeróbios, produzindo um efluente de excelente qualidade. / This research evaluated the efficiency of a full scale submerged aerated biofilter (SAB) used for post-treatment of the effluent of an upflow anaerobic sludge blanket (UASB) reactor, located in the wastewater treatment plant Água Vermelha (São Carlos, SP, Brazil), under unfavorable hydraulic conditions. The removal of organic matter and solids, the possibility of removal of nitrogen and phosphorus and also the characterization of biomass attached to the packing media were studied. This study vas developed in two phases, one without reactor seeding (phase I), and another when the reactor was seeded (phase II). At phase I, a flow rate of 380 m³/d and a volumetric loading rate of 3 kgCOD/m³.d with hydraulic load (HL) of 8 m³/m².d were applied, with 170 minutes of hydraulic retention time (HRT). In this phase the biofilter reached average efficiencies of 40% in organic matter removal (COD) and 35% for TSS. Already in phase II, a flow rate of 500 m³/d, a volumetric loading rate of 4kgCOD/m³.d with HL of 11 m³/ m².dia were applied, with 130 minutes of HRT. The SAB allowed average removal efficiencies of COD, \'TOC IND.F\' and TSS of 36%, 60% and 30%, respectively, for phase II. The conversion of nitrite to nitrate was considered worthless, likely attributed to the high value of affluent COD to the SAB, the occurrence of nitrification and denitrification in the same biofilm and the inefficient air distribution in the interior of the reactor. The biofilter did not present good results in phosphorus removal. This study allowed to conclude that the aerated submerged biological filter presented a satisfactory performance as a post-treatment unit of an UASB reactor during the start-up phase, being submitted to high hydraulic and organic loads. It was found that the employment of the submerged aerated biofilter is an advantageous alternative as anaerobic effluent post-treatment, producing excellent quality effluent.
79

Flotação aplicada ao pós-tratamento do efluente de reator anaeróbio de leito expandido tratando esgoto sanitário / Flotation applied to the post-treatment of effluents from expanded bed anaerobic reactor treating domestic sewage

Rogério Gomes Penetra 23 May 2003 (has links)
Este trabalho apresenta e discute os resultados de um estudo amplo e aprofundado sobre os principais parâmetros operacionais da flotação por ar dissolvido, utilizada no pós-tratamento de efluentes de um reator anaeróbio de leito expandido (RALEx), tratando 10 m3/hora de esgoto sanitário. Foram realizados preliminarmente ensaios utilizando o flotateste, unidade de flotação em escala de laboratório, para identificar as melhores dosagens de coagulante (cloreto férrico), o polímero mais adequado, dentre os 26 testados, e sua respectiva dosagem, o pH de coagulação adequado, o tempo (Tf) e o gradiente de velocidade (Gf) de floculação mais apropriados e a quantidade de ar (S*) requerida. Para obtenção das condições operacionais adequadas para a unidade piloto de flotação, os valores de Tf e de Gf foram variados de zero a 24 minutos e de 40 a 100 s-1, respectivamente. As concentrações de cloreto férrico e de polímero sintético variaram de 15 a 92 mg/L e de 0,25 a 7,0 mg/L, respectivamente. S* variou de 2.85 a 28.5 gramas de ar por metro cúbico de efluente e a taxa de aplicação superficial na unidade de flotação abrangeu de 180 a 250 m3/m2/d. O desempenho da flotação durante a partida do reator anaeróbio também foi investigado. O uso de 50 mg/L de cloreto férrico, de Tf igual a 20 min e Gf de 80 s-1, de S* de 19,7 g de ar por m3 de efluente e taxa de 180 m3/m2/d produziu excelentes resultados nos ensaios com a instalação piloto de flotação, com elevadas remoções de carga de DQO (80,6%), de fósforo total (90,1%) e de sólidos suspensos totais (92,1%) e com turbidez entre 1,6 e 15,4 uT e residuais de ferro de 0,5 mg/L, com remoção estimada, na forma de lodo, de 77 gramas de SST por m3 de efluente tratado. Nestas mesmas condições, no sistema RALEx+FAD, foram observadas remoções globais de 91,6% de carga de DQO, de 90,1% de carga de fósforo e de 96,6% de carga de SST. O emprego da flotação por ar dissolvido (FAD) mostrou-se alternativa bastante atraente para o pós-tratamento de efluentes de reatores anaeróbios. Se a coagulação estiver bem ajustada, o sistema composto de reator anaeróbio seguido de unidade de flotação consegue alcançar excelente remoção de matéria orgânica, redução significativa da concentração de fósforo e de sólidos suspensos, além de precipitação dos sulfetos dissolvidos, gerados no reator anaeróbio. Bons resultados foram alcançados mesmo quando o reator RALEx produziu efluentes de baixa qualidade durante seu período de partida. Nesse período, o sistema de flotação atuou como barreira eficaz, evitando a emissão de efluente de baixa qualidade do sistema. / This research work presents ad discusses the results of a wide and deep study on the main operational parameters of DAF while used for the post-treatment of effluents from a pilot expanded-bed anaerobic (RALEx) reactor. The system received 10 m3 per hour of domestic sewage. Bench-scale assays in flota-test units were first carried out to achieve the best dosage of coagulants (ferric chloride), the best polymer and respective dosages, the adjusted pH for coagulation, the flocculation time (Tf), the proper velocity gradient (Gf) and the amont of air (S*) required. In order to obtain the proper operational conditions in the pilot DAF plant, Tf and Gf were made to vary from zero to 24 minutes and from 40 to 100 s-1, respectively. The chemicals ferric chloride and synthetic polymer concentrations ranged from 15 to 92 mg/L and 0.25 to 7.0 mg/L, repectively. S* varied from 2.85 to 28.5 grams of air per cubic meter of wastewater and the applied flotation rates ranged from 180 to 250 m3.m-2.d-1. DAF performance was also investigated during RALEx start-up period. At the DAF operational conditions of 50 mgFeCl3.l-1, Tf of 15 min, Gf of 80 s-1, S* of 19.7 g of air per m3 of wastewater and the applied loading rate of 180 m3.m-2.d-1, the removal efficiencies attained 80.6% for COD, 90.1% for phosphorus, 92.1% for suspended solids, producing effluents with turbidity ranged from 1.6 to 15.4 NTU, residual Fe of 0.5 mg/L, removing 77 grams of SST per cubic meter of wastewater. At the same conditions, the system RALEx-DAF presented global efficiencies of 91.6% for COD, 90.1% for phosphorus and 96.6% for suspended solids. The utilization of dissolved-air flotation (DAF) constitutes an attractive alternative for the post-treatment of anaerobic reactor´s effluents. If coagulation is well adjusted, such system composed of anaerobic reactor followed by DAF can achieve excellent organic matter removal, expressive solids and phosphorus reduction and precipitation of dissolved sulfide generated in the anaerobic unit. Good results were also obtained even when RALEx produced low quality effluents during start-up period. In such period, the DAF unit functioned as an efficient barrier for avoiding the emission of low quality system effluent.
80

Pós-tratamento físico-químico por flotação de efluentes de reatores anaeróbios de manta de lodo (UASB) / Physical-chemical post-treatment by flotation of effluents from upflow anaerobic sludge blanket (UASB)

Rogério Gomes Penetra 29 May 1998 (has links)
O emprego da flotação por ar dissolvido (FAD) para o pós-tratamento de efluentes de reatores anaeróbios aparenta ser atraente considerando algumas características desse processo físico-químico. A FAD é reconhecidamente um processo de alta taxa, particularmente eficiente na remoção de material particulado em suspensão e de flocos produzidos pela coagulação química de águas residuárias. Além disso, há produção de lodo espesso e provavelmente arraste de parcela de gases e de compostos voláteis, presentes nos efluentes anaeróbios. Entretanto, a concepção de sistemas de FAD deve ser precedida por ensaios em unidades de flotação em escala de laboratório, permitindo a determinação dos principais parâmetros do processo. Neste trabalho, são apresentados e discutidos os resultados obtidos em laboratório e em instalação piloto de flotação com escoamento contínuo recebendo efluente de reator anaeróbio de manta de lodo (UASB), com 18 m3 de volume, tratando esgoto sanitário. Os ensaios em unidade em escala de laboratório foram realizados utilizando diferentes dosagens de cloreto férrico (entre 30 e 110 mg/L) ou de polímero catiônico (entre 1,0 e 16,0 mg/L), atuando como coagulantes. Além disso, foram estudadas as condições de floculação (tempo de 15 e de 25 min, e gradiente médio de velocidade de floculação entre 30 e 100 s-1) e diferentes valores de quantidade de ar fornecido ao processo (S*, entre 4,7 e 28,5 g de ar por m3 de efluente). Com a instalação piloto de FAD foram realizados apenas ensaios preliminares variando-se a taxa de aplicação superficial (140 e 210 m3/m2/d) para diferentes valores de S* (14,8 a 29,5 g de ar por m3 de efluente). Com o emprego de dosagem de 65 mg/L de cloreto férrico, de tempo de 15 min e gradiente médio de velocidade de floculação de 80 s-1 e de 19 g de ar por m3 de efluente, foram observados excelentes resultados em laboratório, com elevadas remoções de DQO (89%), de fosfato total (96%), de sólidos suspensos totais (96%), de turbidez (98%), de cor aparente (91%), de sulfetos (não detectado) e NTK (47%). Considerando o sistema UASB e FAD, nos testes em laboratório, foram observadas remoções globais de 97,7% de DQO, de 98,0% de fosfato total, de 98,9% de SST, de 99,5% de turbidez, de 97,8% de cor aparente e de 59,0% de NTK. Nos ensaios com a instalação piloto de FAD, o sistema apresentou remoções de 93,6% de DQO, de 87,1% de SST, de 90% de sulfetos e de 30% de NTK. / The utilization of dissolved-air flotation (DAF) for the post-treatment of effluents from anaerobic reactors seems to be attractive considering some characteristics features of such a physical-chemical process. DAF is known to be a high-rate process particularly efficient for the removal of suspended particles and flocs produced by the chemical coagulation of wastewaters. Moreover, it produces a thick sludge and probably promotes the stripping of gases and volatile compounds present in anaerobic effluents. However, the design of DAF systems has to be preceeded by assays in lab-scale units permiting to establish the main process parameters. The results obtained from a lab-scale unit receiving effluent of a 18 m3 upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage are presented and discussed. The assays were performed firstly in a lab-scale unit, using ferric chloride (from 30 to 110 mg/L) or cationic polymer (from 1.0 to 16.0 mg/L) as coagulant under different concentrations. In order to obtain proper conditions for flocculation time (t) was fixed at 15 and 25 min and velocity gradient (G) was ranged form 30 to 100 s-1. The required quantity of air (S*) was ranged from 4.7 to 28.5 g of air per m3 of wastewater. Using a FAD pilot plant, only preliminary assays were performed, using two surface load rate values (140 e 210 m3/m2/d) and different S* values (from 14.8 to 29.5 g of air per m3 of wastewater). Using a lab-scale unit, 65 mg/L FeCl3, 15 min for t, 80 s-1 for G and 19.0 g of air per m3 of wastewater for S*, the removal efficiencies obtained were 89% for COD, 96% for total phosphate, 96% for suspended solids, 98% for turbidity, 91% for apparent color, 47% for TKN and sulphites were not detected in final effluent. For the UASB-DAF systems, still in labscale unit, global efficiencies were 97.7% for COD, 98.0% for total phosphate, 98.9% for suspended solids, 99.5% for turbidity, 97.8% for apparent color and 59.0% for TKN. Using DAF pilot plant, system global efficiencies were 93.6% for COD, 87.1% for suspended solids, 90% for sulphites and 30% for TKN.

Page generated in 0.0784 seconds