• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 23
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 72
  • 72
  • 26
  • 25
  • 21
  • 12
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Differential capacity of stainless steel in potassium chloride solutions during potentiostatic and galvanostatic polarization

Fiorino, M. Elaine Curley-, January 1975 (has links)
Thesis--University of Florida. / Description based on print version record. Typescript. Vita. Includes bibliographical references (leaves 179-186).
22

I. The electrolysis of potassium chloride.

Lukens, Hiram Stanhope. January 1913 (has links)
Thesis (PH. D.)--University of Pennsylvania, 1913.
23

Cellular mechanism and regulation of KCl transport across an insect epithelium

Hanrahan, John William January 1982 (has links)
The cellular mechanism and regulation of KC1 reabsorption across the rectum of the desert locust Schistocerca gregaria has been studied using tracer fluxes, ion-sensitive microelectrodes, and electrophysiological techniques. Serosal addition of 1 mM cAMP stimulates transepithelial short- circuit current (I[sub=SC]) and net Cl absorption (J[sub=net;sup=Cl] ) 10-fold, increases transepithelial potential (V[sub=t]) 4-fold, and reduces transepithelial resistance (R[sub=T]) by 40-65%. The properties of locust Cl transport are not consistent with NaCl cotransport models proposed in other epithelia: i) Cl is absorbed from nominally Na-free saline, ii) there is no correlation between trace amounts of Na contamination and the rate of Cl transport, iii) exposure to cAMP increases ³⁶Cl influx across the apical border into rectal tissue without affecting ²²Na influx, iv) Cl-dependent I[sub=SC] is not inhibited by 1 mM ouabain (2 h) or 1 mN furosemide (1 h), v) J[sub=net;sub=Cl] is not affected when the apical Na electrochemical gradient is reduced by 85%, and vi) there is no relationship between Na and Cl net electrochemical gradients across the apical membrane. Cl/HCO₃ exchange is also unlikely since i) Cl-transport is electrogenic, ii) J[sub=net;sub=Cl] is insensitive to CO₂⁻ and HCO₃⁻ removal, and iii) Cl-dependent I[sub=SC] is not inhibited by 1 mM SITS or 1 mM acetazolamide after 1 h exposure. The cAMP-stimulated system is Cl-selective: Cl >> Br >> I,F,SCN,P0₄,SO₄.C₂H₃O₂,urate. The halide sequence suggests a site having high field strength. Cl-dependent I[sub=SC] is inhibited by low mucosal pH and high osmotic pressure. J[sub=net;sub=Cl] obeys Michaelis-Menten-type kinetics. Mucosal K increases both the K[sub=m] and V[sub=max] of transepithelial Cl absorption (K[sub=a] = 5.3 mM K). The active step in J[sub=net;sub=Cl] is at the apical membrane because net entry of Cl occurs against a large, unfavourable electrochemical gradient. Serosal cAMP and mucosal K directly stimulate the active step since both of these agents cause simultaneous increases in J[sub=net;sub=Cl] and the electrochemical potential opposing CI entry. Passive K transport in the mucosa-to-serosa direction is favoured across apical and basal membranes. Most K absorption (~84%) is electrically coupled to active CI transport under open-circuit conditions, however a small active component is apparent during exposure to cAMP. The response of V[sub=T] to transepithelial salt gradients depends strongly on the direction of the gradients, suggesting that locust rectum is a "tight" epithelium. Intracellular current and fluorescent dye injections reveal strong coupling between rectal cells. Flat-sheet cable analysis indicates that locust rectum becomes "tighter" during cAMP exposure, when transcellular conductance increases from 60 to 95% of the total tissue conductance. cAMP increases apical membrane K conductance and basal membrane CI conductance. K permeability is inhibited by high (physiological) K and osmotic concentrations. The driving force of CI transport is calculated by two independent methods and the results are interpreted in terms of an equivalent electrical circuit model for KCl reabsorption across locust rectum. / Science, Faculty of / Zoology, Department of / Graduate
24

Dinâmica do entupimento de tubos gotejadores sob aplicação de cloreto de potássio (branco e vermelho) via diferentes qualidades de água / Clogging dynamics of driplines under the application of potassium chloride (white and red) for different water qualities

Ribeiro, Pabblo Atahualpa de Aguiar 31 October 2008 (has links)
Neste trabalho buscou-se avaliar a suscetibilidade dos diferentes modelos de tubos gotejadores ao processo de entupimento quando expostos ao uso de cloreto de potássio (branco e vermelho), aplicados via diferentes qualidades de água. O experimento foi realizado em três fases, por um período de doze meses, analisando o desempenho de 22 modelos de gotejadores (autocompensante e convencionais), com quatro tratamentos e dez repetições, sendo cada repetição representada por um gotejador. Na primeira fase, foram aplicados os seguintes tratamentos: (T1) água com fitoplâncton (lago) e cloreto de potássio branco; (T2) água com fitoplâncton (lago) e cloreto de potássio vermelho; (T3) água potável (laboratório) e cloreto de potássio branco; (T4) água potável (laboratório) e cloreto de potássio vermelho. Na segunda fase foram adicionadas partículas sólidas (solo) às soluções dos tratamentos 1 (T1-Lg/B) e 2 (T2-Lg/V), mantendo a mesma solução do tratamento 3 (T3-Lb/B) e adicionado sulfato de ferro à solução do tratamento 4 (T4-Lb/V). Na terceira fase acrescentou-se hidróxido de ferro às soluções referentes a T1 (T1+So) e T2 (T2+So), mais uma aplicação de uma solução concentrada diretamente nas linhas (tubos gotejadores) sem passar pelo sistema de filtragem, sendo os tratamentos: (T1) Água do lago, cloreto de potássio branco, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para baixo. (T2) água do lago, cloreto de potássio vermelho, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para cima. (T3) água do lago , cloreto de potássio branco, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para cima. (T4) água do lago, cloreto de potássio vermelho, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para baixo. Os modelos de tubos gotejadores analisados apresentaram desempenhos variáveis, tanto na suscetibilidade ao entupimento quanto no coeficiente de variação de vazão, sugerindo que a arquitetura interna dos gotejadores, foi o fator determinante na caracterização do processo de entupimento. Não foi observada diferença significativa da dinâmica de entupimento com relação à aplicação dos cloretos de potássio branco e vermelho na ausência ou presença de fitoplâncton, mostrando que é possível fazer uso do cloreto de potássio vermelho em fertirrigação, tomando o cuidado de verificar a ausência do elemento ferro no adubo (análise de laboratório). A adição de partículas sólidas e do sulfato de ferro aos tratamentos da primeira fase, passando pelo sistema de filtragem, não potencializou mudanças significativas do cenário de suscetibilidade ao entupimento, nas condições de irrigação da segunda fase. A entrada de partículas sólidas e hidróxido de ferro no sistema sem passar pelo sistema de filtragem (fase 3) e o posicionamento do orifício dos gotejadores para baixo intensificaram o processo de entupimento, onde os modelos convencionais foram os mais sensíveis e alguns modelos autocompensantes foram mais tolerantes a presença destes elementos na água de irrigação. O modelo C3 foi o que apresentou melhor desempenho entre os modelos convencionais nas três fases estudadas, sendo que os modelos A2 e A3 destacaram-se entre os modelos autocompensantes, com uma boa recuperação da vazão ao final dos ensaios. / This work aims to evaluate the susceptibility of several dripline models against clogging process when exposed to potassium chloride (white and red), applied through different water qualities (fertirrigation). The experiment was accomplished in three phases, during a period of twelve months, analyzing the performance of 22 drip models (compensating and conventional), with four treatments and ten repetitions, being each repetition a dripper. In the first phase, it was applied the following treatments: (T1) water with fitoplancton (lake) and white potassium chloride; (T2) water with fitoplancton (lake) and red potassium chloride; (T3) potable water (laboratory) and white potassium chloride; (T4) potable water (laboratory) and red potassium chloride. In the second phase, solid particles were added to the solutions of previous treatments 1 (T1-Lg/B) and 2 (T2-Lg/V), maintaining the same solution for treatment 3 (T3-Lb/B) and added iron sulfate to the solution of treatment 4 (T4-Lb/V). In the third phase iron hydroxide was added to the solutions of T1 (T1+So) and T2 (T2+So) treatments, one more application of a concentrated solution directly in drip lines without passing through the filtration system, resulting the following treatments: (T1) water with fitoplancton, white potassium chloride, solid particles and iron hydroxide, with dripper facing down. (T2) water with fitoplancton, red potassium chloride, solid particles and iron hydroxide, with drippers facing up, (T3) water with fitoplancton , white potassium chloride, solid particles and iron hydroxide, with drippers facing up, (T4) water with fitoplancton, red potassium chloride, solid particles and hydroxide of iron, with drippers facing down. Driplines presented a variable performance, regarding the original flow rate levels and variation coefficient, suggesting that internal architecture of emitters, it is a major factor related to clogging resistance to treatments imposed. Statistical differences were not observed for clogging dynamics under the application of white or red potassium chloride, under different water quality conditions, showing that it is possible to use the red potassium chloride for fertirrigation without problems. It is recommended to certify the absence of iron element in the fertilizer based on laboratory analysis. The addition of solid particles and iron sulfate to first phase treatments, going through the filtration system, did not increase the clogging rate or emitters (second phase). The application of solid particles and iron hydroxide in the system without passing through the filtration system (phase 3) and the positioning of drippers facing down, intensified the clogging process. Conventional models were more sensitive and compensating models were more tolerant of this water quality conditions. Models C3 performance better among the conventional models in all phases studied. Models A2 and A3 stood out among compensating models, presenting a good recovery flow rate at the end of the experiment.
25

Estudo de banhos ácidos para substituição de banho alcalino cianídrico na eletrodeposição de zinco sobre pregos / Study of acid baths to replace alcaline cianidric bath used in nail zinc electrodeposition

Martins, Douglas Fróes January 2009 (has links)
O objetivo deste trabalho é determinar um processo com qualidade suficiente para produzir revestimentos de zinco a partir de banho ácido à base de cloreto de potássio, por meio de comparação de resultados. O estudo foi realizado comparando dois tipos de banhos disponíveis no mercado, através da caracterização das amostras produzidas em um protótipo da linha de galvanização, projetada para simular o processo industrial. Neste trabalho, foram avaliados parâmetros operacionais e a influência dos aditivos e formulação básica. Na avaliação da qualidade do depósito, além da determinação da espessura de camada, foram avaliadas sua uniformidade através do ensaio de Preece e a morfologia por microscopia eletrônica de varredura. O desempenho em corrosão foi comparado em ensaio de corrosão acelerada em câmara úmida e espectroscopia de impedância eletroquímica. A influência dos aditivos na polarização dos banhos foi avaliada no ensaio de voltametria. As análises permitiram determinar o banho com melhor e mais estável resultado no produto, conhecer a influência das condições operacionais e dos aditivos no depósito, além do melhor desempenho em corrosão. / The goal of this study is to determine a process with sufficient quality to produce zinc coatings from acid bath of potassium chloride, by comparison of results. This study was conducted comparing two types of baths available in the market through the characterization of the samples produced in a prototype in-line galvanizing, designed to simulate the industrial process. In this work, were assessed operational parameters and the additives and basic formulation influence. In the assessment of deposit quality, in addition to determining the layer thickness, its uniformity was evaluated by Preece test and morphology by Scanning Electronic Microscopy. The performance in corrosion was compared by accelerated corrosion test in a moist chamber and Electrochemical Impedance Spectroscopy. The additives influence in the baths polarization was evaluated in the Voltammetry test. The analysis allowed to determine the bath with better and more stable results in the product, knowing the influence of operating conditions and additives on the deposit, in addition to better performance in corrosion.
26

Estudo de banhos ácidos para substituição de banho alcalino cianídrico na eletrodeposição de zinco sobre pregos / Study of acid baths to replace alcaline cianidric bath used in nail zinc electrodeposition

Martins, Douglas Fróes January 2009 (has links)
O objetivo deste trabalho é determinar um processo com qualidade suficiente para produzir revestimentos de zinco a partir de banho ácido à base de cloreto de potássio, por meio de comparação de resultados. O estudo foi realizado comparando dois tipos de banhos disponíveis no mercado, através da caracterização das amostras produzidas em um protótipo da linha de galvanização, projetada para simular o processo industrial. Neste trabalho, foram avaliados parâmetros operacionais e a influência dos aditivos e formulação básica. Na avaliação da qualidade do depósito, além da determinação da espessura de camada, foram avaliadas sua uniformidade através do ensaio de Preece e a morfologia por microscopia eletrônica de varredura. O desempenho em corrosão foi comparado em ensaio de corrosão acelerada em câmara úmida e espectroscopia de impedância eletroquímica. A influência dos aditivos na polarização dos banhos foi avaliada no ensaio de voltametria. As análises permitiram determinar o banho com melhor e mais estável resultado no produto, conhecer a influência das condições operacionais e dos aditivos no depósito, além do melhor desempenho em corrosão. / The goal of this study is to determine a process with sufficient quality to produce zinc coatings from acid bath of potassium chloride, by comparison of results. This study was conducted comparing two types of baths available in the market through the characterization of the samples produced in a prototype in-line galvanizing, designed to simulate the industrial process. In this work, were assessed operational parameters and the additives and basic formulation influence. In the assessment of deposit quality, in addition to determining the layer thickness, its uniformity was evaluated by Preece test and morphology by Scanning Electronic Microscopy. The performance in corrosion was compared by accelerated corrosion test in a moist chamber and Electrochemical Impedance Spectroscopy. The additives influence in the baths polarization was evaluated in the Voltammetry test. The analysis allowed to determine the bath with better and more stable results in the product, knowing the influence of operating conditions and additives on the deposit, in addition to better performance in corrosion.
27

Estudo de banhos ácidos para substituição de banho alcalino cianídrico na eletrodeposição de zinco sobre pregos / Study of acid baths to replace alcaline cianidric bath used in nail zinc electrodeposition

Martins, Douglas Fróes January 2009 (has links)
O objetivo deste trabalho é determinar um processo com qualidade suficiente para produzir revestimentos de zinco a partir de banho ácido à base de cloreto de potássio, por meio de comparação de resultados. O estudo foi realizado comparando dois tipos de banhos disponíveis no mercado, através da caracterização das amostras produzidas em um protótipo da linha de galvanização, projetada para simular o processo industrial. Neste trabalho, foram avaliados parâmetros operacionais e a influência dos aditivos e formulação básica. Na avaliação da qualidade do depósito, além da determinação da espessura de camada, foram avaliadas sua uniformidade através do ensaio de Preece e a morfologia por microscopia eletrônica de varredura. O desempenho em corrosão foi comparado em ensaio de corrosão acelerada em câmara úmida e espectroscopia de impedância eletroquímica. A influência dos aditivos na polarização dos banhos foi avaliada no ensaio de voltametria. As análises permitiram determinar o banho com melhor e mais estável resultado no produto, conhecer a influência das condições operacionais e dos aditivos no depósito, além do melhor desempenho em corrosão. / The goal of this study is to determine a process with sufficient quality to produce zinc coatings from acid bath of potassium chloride, by comparison of results. This study was conducted comparing two types of baths available in the market through the characterization of the samples produced in a prototype in-line galvanizing, designed to simulate the industrial process. In this work, were assessed operational parameters and the additives and basic formulation influence. In the assessment of deposit quality, in addition to determining the layer thickness, its uniformity was evaluated by Preece test and morphology by Scanning Electronic Microscopy. The performance in corrosion was compared by accelerated corrosion test in a moist chamber and Electrochemical Impedance Spectroscopy. The additives influence in the baths polarization was evaluated in the Voltammetry test. The analysis allowed to determine the bath with better and more stable results in the product, knowing the influence of operating conditions and additives on the deposit, in addition to better performance in corrosion.
28

Dinâmica do entupimento de tubos gotejadores sob aplicação de cloreto de potássio (branco e vermelho) via diferentes qualidades de água / Clogging dynamics of driplines under the application of potassium chloride (white and red) for different water qualities

Pabblo Atahualpa de Aguiar Ribeiro 31 October 2008 (has links)
Neste trabalho buscou-se avaliar a suscetibilidade dos diferentes modelos de tubos gotejadores ao processo de entupimento quando expostos ao uso de cloreto de potássio (branco e vermelho), aplicados via diferentes qualidades de água. O experimento foi realizado em três fases, por um período de doze meses, analisando o desempenho de 22 modelos de gotejadores (autocompensante e convencionais), com quatro tratamentos e dez repetições, sendo cada repetição representada por um gotejador. Na primeira fase, foram aplicados os seguintes tratamentos: (T1) água com fitoplâncton (lago) e cloreto de potássio branco; (T2) água com fitoplâncton (lago) e cloreto de potássio vermelho; (T3) água potável (laboratório) e cloreto de potássio branco; (T4) água potável (laboratório) e cloreto de potássio vermelho. Na segunda fase foram adicionadas partículas sólidas (solo) às soluções dos tratamentos 1 (T1-Lg/B) e 2 (T2-Lg/V), mantendo a mesma solução do tratamento 3 (T3-Lb/B) e adicionado sulfato de ferro à solução do tratamento 4 (T4-Lb/V). Na terceira fase acrescentou-se hidróxido de ferro às soluções referentes a T1 (T1+So) e T2 (T2+So), mais uma aplicação de uma solução concentrada diretamente nas linhas (tubos gotejadores) sem passar pelo sistema de filtragem, sendo os tratamentos: (T1) Água do lago, cloreto de potássio branco, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para baixo. (T2) água do lago, cloreto de potássio vermelho, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para cima. (T3) água do lago , cloreto de potássio branco, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para cima. (T4) água do lago, cloreto de potássio vermelho, partículas sólidas e hidróxido de ferro, com o orifício do gotejador posicionado para baixo. Os modelos de tubos gotejadores analisados apresentaram desempenhos variáveis, tanto na suscetibilidade ao entupimento quanto no coeficiente de variação de vazão, sugerindo que a arquitetura interna dos gotejadores, foi o fator determinante na caracterização do processo de entupimento. Não foi observada diferença significativa da dinâmica de entupimento com relação à aplicação dos cloretos de potássio branco e vermelho na ausência ou presença de fitoplâncton, mostrando que é possível fazer uso do cloreto de potássio vermelho em fertirrigação, tomando o cuidado de verificar a ausência do elemento ferro no adubo (análise de laboratório). A adição de partículas sólidas e do sulfato de ferro aos tratamentos da primeira fase, passando pelo sistema de filtragem, não potencializou mudanças significativas do cenário de suscetibilidade ao entupimento, nas condições de irrigação da segunda fase. A entrada de partículas sólidas e hidróxido de ferro no sistema sem passar pelo sistema de filtragem (fase 3) e o posicionamento do orifício dos gotejadores para baixo intensificaram o processo de entupimento, onde os modelos convencionais foram os mais sensíveis e alguns modelos autocompensantes foram mais tolerantes a presença destes elementos na água de irrigação. O modelo C3 foi o que apresentou melhor desempenho entre os modelos convencionais nas três fases estudadas, sendo que os modelos A2 e A3 destacaram-se entre os modelos autocompensantes, com uma boa recuperação da vazão ao final dos ensaios. / This work aims to evaluate the susceptibility of several dripline models against clogging process when exposed to potassium chloride (white and red), applied through different water qualities (fertirrigation). The experiment was accomplished in three phases, during a period of twelve months, analyzing the performance of 22 drip models (compensating and conventional), with four treatments and ten repetitions, being each repetition a dripper. In the first phase, it was applied the following treatments: (T1) water with fitoplancton (lake) and white potassium chloride; (T2) water with fitoplancton (lake) and red potassium chloride; (T3) potable water (laboratory) and white potassium chloride; (T4) potable water (laboratory) and red potassium chloride. In the second phase, solid particles were added to the solutions of previous treatments 1 (T1-Lg/B) and 2 (T2-Lg/V), maintaining the same solution for treatment 3 (T3-Lb/B) and added iron sulfate to the solution of treatment 4 (T4-Lb/V). In the third phase iron hydroxide was added to the solutions of T1 (T1+So) and T2 (T2+So) treatments, one more application of a concentrated solution directly in drip lines without passing through the filtration system, resulting the following treatments: (T1) water with fitoplancton, white potassium chloride, solid particles and iron hydroxide, with dripper facing down. (T2) water with fitoplancton, red potassium chloride, solid particles and iron hydroxide, with drippers facing up, (T3) water with fitoplancton , white potassium chloride, solid particles and iron hydroxide, with drippers facing up, (T4) water with fitoplancton, red potassium chloride, solid particles and hydroxide of iron, with drippers facing down. Driplines presented a variable performance, regarding the original flow rate levels and variation coefficient, suggesting that internal architecture of emitters, it is a major factor related to clogging resistance to treatments imposed. Statistical differences were not observed for clogging dynamics under the application of white or red potassium chloride, under different water quality conditions, showing that it is possible to use the red potassium chloride for fertirrigation without problems. It is recommended to certify the absence of iron element in the fertilizer based on laboratory analysis. The addition of solid particles and iron sulfate to first phase treatments, going through the filtration system, did not increase the clogging rate or emitters (second phase). The application of solid particles and iron hydroxide in the system without passing through the filtration system (phase 3) and the positioning of drippers facing down, intensified the clogging process. Conventional models were more sensitive and compensating models were more tolerant of this water quality conditions. Models C3 performance better among the conventional models in all phases studied. Models A2 and A3 stood out among compensating models, presenting a good recovery flow rate at the end of the experiment.
29

Pore migration in potassium chloride due to a temperature gradient

Lemaire, Paul Joseph January 1980 (has links)
Thesis (Ph.D.)--Massachusetts Institute of Technology, Dept. of Materials Science and Engineering, 1980. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND SCIENCE. / Vita. / Bibligraphy: leaves 222-228. / by Paul Joseph Lemaire. / Ph.D.
30

Grain boundary mobility of KCl.

Yan, Man Fei January 1976 (has links)
Thesis (Sc. D.)--Massachusetts Institute of Technology, Dept. of Materials Science and Engineering, 1976. / Vita. / Bibliography: leaves 231-251. / Sc.D.

Page generated in 0.0706 seconds