• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analys av fördelningssystem för bostadshus

Larsson, Johan January 2012 (has links)
The purpose of this project is to analyze earthing systems for houses. By practical measurements and theoretical analyzes consequences of possible faults, that can occur within the facility and in the low-voltage distribution network, is illustrated.   The reason for this project is that nowadays one has to arrange with a main equipotential bonding system for buildings. Apart from that, if necessary, bathrooms must be provided with a supplementary equipotential bonding system. The practical measurements verify that potential differences in facilities may be due to voltage drops in the PEN conductor between the origin of the electrical installation and the power transformer. Based on the theoretical analyzes of possible faults, it is considered that the requirement for  supplementary equipotential bonding systems for bathrooms in most cases can be questioned, when basic insulation, fault protection, residual current devise and main equipotential bonding system already provides an adequate level of protection. A PEN conductor loss may result in a situation where metallic parts attached to the equipotential bonding system starts working as earth electrodes. Equipotential bonding system may also increase the incidence of stray currents. If TN-C-S systems is provided with a local connection to earth a redundant system against PEN conductor loss is obtained. That is not the case for neutral conductor loss in TN-S systems with a local connection to earth. If district heating pipes is supplied with insulated flanges it prevents stray currents and foreign potential to be spread in the district heating network.
2

Elmiljö och potentialutjämning

Mahmoud, Diyari January 2014 (has links)
Potentialskillnader mellan elektriskt utsatta delar och andra åtkomliga ledande delar i byggnaden eller anläggningar kan orsaka livsfarliga elektriska urladdningar (strömgenomgångar) vid beröring. Potentialskillnader orsakar även problem för elektriska apparater att fungera tillfredsställande i sin omgivning. Syftet med studien var att undersöka och identifiera uppkomsten till potentialskillnader samt de olika tolkningskonflikter som finns vid förbyggandet av problemen. Dagens elmiljöproblem beror till stor del på den snabba teknikutvecklingen av elektroniken vi använder. För att lösa en stor del ut detta problem utför man potentialutjämning. Resultatet av denna studie visar att skyddsutjämning ska utföras i alla anläggningar. Det skyddar mot elchock i byggnader och industriella anläggningar. Funktionsutjämning upprätthåller utrustningens funktionssäkerhet i industriella anläggningar och är inte ett krav. Den skiljer sig beroende på nivå av känslig miljö. Denna studie utfördes som examensarbete på Kungliga Tekniska Högskolan för Ramböll Sverige AB. Tolkningarna har gjorts utifrån Elinstallationsreglerna, SEK Handbok 413 samt SEK Handbok 449.

Page generated in 0.117 seconds