Spelling suggestions: "subject:"power supplied""
41 |
A new UPS topology and deadbeat control techniques for improved utility interface compatibilityKamran, Farrukh 12 1900 (has links)
No description available.
|
42 |
Analysis and design of switching DC/DC converters /Plesnik, Martin, January 1900 (has links)
Thesis (M.App.Sc.) - Carleton University, 2002. / Includes bibliographical references (p. 175-182). Also available in electronic format on the Internet.
|
43 |
A base control Doherty power amplifier design for improved efficiency in GSM handsets /Ferwalt, Darren W. January 1900 (has links)
Thesis (M.S.)--Oregon State University, 2004. / Printout. Includes bibliographical references (leaves 73-75). Also available on the World Wide Web.
|
44 |
Signal and power integrity co-simulation using the multi-layer finite difference methodBharath, Krishna. January 2009 (has links)
Thesis (M. S.)--Electrical and Computer Engineering, Georgia Institute of Technology, 2009. / Committee Chair: Madhavan Swaminathan; Committee Member: Andrew F. Peterson; Committee Member: David C. Keezer; Committee Member: Saibal Mukhopadyay; Committee Member: Suresh Sitaraman.
|
45 |
Fuse holder damage investigationWacharasindhu, Tongtawee. January 2006 (has links)
Thesis (M.S.) University of Missouri-Columbia, 2006. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file (viewed on August 29, 2007) Includes bibliographical references.
|
46 |
Analise da confiabilidade do sistema de suprimento de energia eletrica de emergencia de um reator nuclear de pequeno porteBONFIETTI, GERSON 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:03Z (GMT). No. of bitstreams: 1
09246.pdf: 5265828 bytes, checksum: 4d1524b4005b3c1696584a11c7c97252 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
47 |
Síntese de controladores ressonantes baseado em dados aplicado a fontes ininterruptas de energiaSchildt, Alessandro Nakoneczny January 2014 (has links)
Este trabalho trata da utilização de um método de sintonia de controladores baseado nos dados obtidos da planta. A proposta é a sintonia de controladores ressonantes para aplicação em inversores de frequência presentes em fontes ininterruptas de energia, com o intuito de seguimento de referência senoidal de tensão. Dentro deste contexto, será usado o algoritmo Virtual Reference Feedback Tuning, o qual é um método de identificação de controladores baseado em dados que não é iterativo e não necessita do modelo do sistema para identificar o controlador. A partir dos dados obtidos da planta e também da definição de um modelo de referência pelo projetista, o método estima os parâmetros de uma estrutura fixada previamente para o controlador através da minimização de uma função custo definida pelo erro entre a saída desejada e a saída real. Além disso, uma realimentação de corrente é necessária na malha de controle, onde seu ganho proporcional é definido por experimento empírico. Para demonstrar a utilização do método são apresentados resultados simulados e práticos de uma fonte ininterrupta de energia com potência de 5 kV A utilizando cargas lineares e não-lineares. É avaliado o desempenho do ponto de vista da qualidade do sinal de saída real obtido com controladores sintonizados a partir de diferentes modelos de referência, além do uso de sinais de excitação diversos para o algoritmo V RFT. Os resultados experimentais são obtidos em um inversor de frequência monofásico com uma plataforma em tempo real baseada na placa de aquisição de dados dSPACE DS1104. Os resultados mostram que, em relação as normas internacionais, o sistema de controle proposto possui bom comportamento para seguimento de referência, operando à vazio ou utilizando carga linear. / This work discusses about controller tuning methods based on plant data. The proposal is to tune resonant controllers for application to the frequency inverters found in uninterruptible power supplies, with the goal of following sinusoidal reference signals. Within this context, the Virtual Reference Feedback Tuning algorithm is used, which is a data-driven controller identification method that is not iterative and does not require a system model to identify the controller. Data obtained from the plant and also the definition of a reference model by the designer, are used by the method to estimate the parameters of a previously fixed controller structure through the minimization of a cost function, which is defined by the error between desired and actual outputs. Moreover, a current feedback is required in the control loop where the proportional gain is defined by empirical experiment. To demonstrate the method’s application, simulated and practical results of an uninterruptible power supply with capacity of the 5 kV A will be presented employing linear and nonlinear loads. Evaluates the performance in terms of system’s actual output quality, obtained with controllers tuned with different reference models. Distinct excitation signals are also used to feed the VRFT algorithm. The experimental results achieved from use of an single-phase inverter and a real-time platform based on data acquisition board dSPACE DS1104. The results show that, with respect to international standards, the proposed control system has good performance for tracking reference, operating at empty or using linear load.
|
48 |
Studium rovnovážné magnetické konfigurace v zařízeních typu tokamak / Study of Equilibrium Magnetic Configuration in Tokamak Type DevicesHavlíček, Josef January 2015 (has links)
This thesis presents the magnetic fields of the COMPASS tokamak and work done during the COMPASS reinstallation in the Czech Republic. The geometry, vacuum magnetic fields and Power Supplies for the poloidal field coils circuits are described in the technical part of the thesis. The design of Power Supplies filters and improvements in the controller algorithm are also introduced. The MHD equilibrium reconstruction code EFIT++ and implementation of the induced currents model are described in the physical part of the thesis. The EFIT++ code was adapted for COMPASS. The utilization of the EFIT++ code for the COMPASS operation is shown. The global power balance in the non-stationary phases of the tokamak discharge is explained and examples are shown. The attached articles describe Power Supplies and tokamak feedback system developed for the COMPASS plasma control. Powered by TCPDF (www.tcpdf.org)
|
49 |
Síntese de controladores ressonantes baseado em dados aplicado a fontes ininterruptas de energiaSchildt, Alessandro Nakoneczny January 2014 (has links)
Este trabalho trata da utilização de um método de sintonia de controladores baseado nos dados obtidos da planta. A proposta é a sintonia de controladores ressonantes para aplicação em inversores de frequência presentes em fontes ininterruptas de energia, com o intuito de seguimento de referência senoidal de tensão. Dentro deste contexto, será usado o algoritmo Virtual Reference Feedback Tuning, o qual é um método de identificação de controladores baseado em dados que não é iterativo e não necessita do modelo do sistema para identificar o controlador. A partir dos dados obtidos da planta e também da definição de um modelo de referência pelo projetista, o método estima os parâmetros de uma estrutura fixada previamente para o controlador através da minimização de uma função custo definida pelo erro entre a saída desejada e a saída real. Além disso, uma realimentação de corrente é necessária na malha de controle, onde seu ganho proporcional é definido por experimento empírico. Para demonstrar a utilização do método são apresentados resultados simulados e práticos de uma fonte ininterrupta de energia com potência de 5 kV A utilizando cargas lineares e não-lineares. É avaliado o desempenho do ponto de vista da qualidade do sinal de saída real obtido com controladores sintonizados a partir de diferentes modelos de referência, além do uso de sinais de excitação diversos para o algoritmo V RFT. Os resultados experimentais são obtidos em um inversor de frequência monofásico com uma plataforma em tempo real baseada na placa de aquisição de dados dSPACE DS1104. Os resultados mostram que, em relação as normas internacionais, o sistema de controle proposto possui bom comportamento para seguimento de referência, operando à vazio ou utilizando carga linear. / This work discusses about controller tuning methods based on plant data. The proposal is to tune resonant controllers for application to the frequency inverters found in uninterruptible power supplies, with the goal of following sinusoidal reference signals. Within this context, the Virtual Reference Feedback Tuning algorithm is used, which is a data-driven controller identification method that is not iterative and does not require a system model to identify the controller. Data obtained from the plant and also the definition of a reference model by the designer, are used by the method to estimate the parameters of a previously fixed controller structure through the minimization of a cost function, which is defined by the error between desired and actual outputs. Moreover, a current feedback is required in the control loop where the proportional gain is defined by empirical experiment. To demonstrate the method’s application, simulated and practical results of an uninterruptible power supply with capacity of the 5 kV A will be presented employing linear and nonlinear loads. Evaluates the performance in terms of system’s actual output quality, obtained with controllers tuned with different reference models. Distinct excitation signals are also used to feed the VRFT algorithm. The experimental results achieved from use of an single-phase inverter and a real-time platform based on data acquisition board dSPACE DS1104. The results show that, with respect to international standards, the proposed control system has good performance for tracking reference, operating at empty or using linear load.
|
50 |
Calculo das probabilidades de falha de suprimento de energia eletrica dos barramentos de classe IE da usina de Angra 1BORBA, P.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:58Z (GMT). No. of bitstreams: 1
00048.pdf: 1060879 bytes, checksum: fa889f74fac825b31f349ea5fafec184 (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
|
Page generated in 0.0604 seconds