• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 612
  • 473
  • 88
  • 26
  • 26
  • 26
  • 26
  • 26
  • 24
  • 19
  • 16
  • 13
  • 8
  • 8
  • 6
  • Tagged with
  • 1499
  • 1499
  • 827
  • 450
  • 267
  • 246
  • 244
  • 223
  • 209
  • 208
  • 190
  • 185
  • 183
  • 175
  • 134
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Optimizing performance in photovoltaic devices based on conjugated poly(phenylene vinylenes)

Warren, Jeremy. January 2006 (has links)
Dissertation (Ph. D.)--University of Akron, Dept. of Polymer Science, 2006. / "May, 2006." Title from electronic dissertation title page (viewed 10/11/2006) Advisor, Frank W. Harris; Committee members, Stephen Z. D. Cheng, David A. Modarelli, Judit Puskas, William J. Brittain; Department Chair, Mark D. Foster; Dean of the College, Frank N. Kelley; Dean of the Graduate School, George R. Newkome. Includes bibliographical references.
112

Determination and dynamic compensation of fictitious power in electric power systems

Enslin, Johan Heinrich Richter 23 September 2014 (has links)
D.Ing. (Electrical & Electronic Engineering) / Please refer to full text to view abstract
113

On the thermal and electrical properties of low concentrator photovoltaic systems

Gerber, Jacques Dewald January 2012 (has links)
Low concentrator photovoltaic systems are capable of increasing the power produced by conventional silicon photovoltaic cells, thus effectively lowering the cost per kWh. However, power losses associated with resistance and temperature have limited the large scale implementation of this technology. In this study, the optical-,electrical- and thermal sub-systems of a low concentrator photovoltaic system are theoretically and experimentally evaluated with the aim of minimizing the power losses associated with series resistance and temperature. A 7-facet reflector system, with an effective concentration ratio of 4.7, is used to focus irradiance along a string of series connected poly-crystalline photovoltaic cells. I-V characteristics of 4-, 6- and 8-cell photovoltaic receivers are measured under 1-sun and 4.83-sun conditions. Under concentration, the 8-cell photovoltaic receiver produced 23 percent more power than the 4-cell photovoltaic receiver, which suggests that the effect of series resistance can be minimized if smaller, lower current photovoltaic cells are used. A thermal model, which may be used to predict operating temperatures of a low concentrator photovoltaic system, is experimentally evaluated within a thermally insulated enclosure. The temperatures predicted by the thermal model are generally within 5 percent of the experimental temperatures. The high operating temperatures associated with the low concentrator photovoltaic system are significantly reduced by the addition of aluminium heat sink. In addition, the results of a thermal stress test indicated that these high operating temperatures do not degrade the photovoltaic cells used in this study. The results of this study suggest that the power output of low concentrator photovoltaic systems can be maximized by decreasing the size of the photovoltaic cells and including an appropriate heat sink to aid convective cooling.
114

On the optical characterization of photovoltaic devices

Gxasheka, Andile Richman January 2008 (has links)
Semiconductor materials used for making photovoltaic (PV) cells have defects and impurities due to constraints of keeping production costs low. Electrically active defects that are distributed over the bulk material lead to reduced overall performance of a photovoltaic (PV) cell. In this study an adaptable Light Beam Induced Current (LBIC) system was designed in order to characterize the local performance of PV cells. The system uses a laser source and objective lens mounted vertically above the sample on the X-Y stage. Two current pre-amplifiers are used for converting the photo-generated current from the PV cell and the signal from the reflection detector cell into a voltage that can be measured by the data acquisition board. Two configurations for measuring the photo-current maps of either bare cells or encapsulated PV mini-modules can be used. To add flexibility it was envisaged that the system would be built in such a way that it allows easy integration of carrier lifetime mapping capabilities while keeping costs to a minimum. The carrier lifetime measurement technique integrated into the LBIC system is based on the optical Open-Circuit Voltage-Decay (OCVD) method. In a single-crystalline silicon PV cell that was tested, photo-current and opencircuit voltage LBIC scans revealed shunting behaviour due to scratch marks on the front surface. The marks are believed to have been caused by poor handling during manufacturing process. Reduced photo-current due to edge shunting was observed towards the edges of the PV cell. In another sample of single crystalline silicon cell an edge shunt resulted in a 30 percent drop in photo-current measured. LBIC measurements performed on multi-crystalline cells revealed nonuniformities such as enhanced photo-current on one side of grain boundaries. These asymmetric enhancements of local photo-current are attributed to the incline of the grain boundary into the bulk of the material. LBIC results obtained from mini modules showed a high degree of mismatching from cell to cell. It is well known that mismatching can degrade the performance of a PV module with series connected cells. The LBIC measurements presented also illustrated the negative effects of delamination on the photo-current of PV modules. The LBIC measurements performed on mini PV modules highlight some of the benefits of using an LBIC technique as a tool for investigating PV cell’s local photo-current response. The effective lifetime maps obtained highlight the importance of optical OCVD method as a tool that can be used in conjunction with conventional LBIC technique. Effective minority carrier lifetimes around 40 ms were measured on a single crystalline silicon cell of 2.5 x 2.5 cm2. Local features such as cracks and lifetime degrading defects were revealed by LBIC maps and were also confirmed on effective lifetime maps. The results presented demonstrate the importance of using effective carrier lifetime maps to complement photocurrent maps of PV cells and identification of areas where defects are located.
115

Modelling and parameter estimation of unknown large power system dynamics

El-Sharkawi, Mohamed Ali Ahmed Ali January 1977 (has links)
The current practice in modelling unknown large power systems is reviewed in Chapter 1, and the inadequate representation by constant voltage and constant frequency is discussed. To determine the unknown large power system dynamics, estimation must be used. A complete model for estimation, including known and unknown power systems, is derived in Chapter 2 and the mathematical formulation in Chapter 3. Chapter 4 presents the estimation algorithm, data and results. It is found that the estimated unknown system parameter values are unique, independent of various operating conditions. Conclusions are drawn in Chapter 5. / Applied Science, Faculty of / Electrical and Computer Engineering, Department of / Graduate
116

Fast fault detection for power distribution systems

Öhrström, Magnus January 2003 (has links)
The main topic of this licentiate thesis is fast faultdetection. The thesis summaries the work performed in theproject“Fast fault detection for distributionsystems”. In the first chapters of the thesis the term“fast”is used in a general manner. The term is laterdefined based upon considerations and conclusions made in thefirst chapters and then related to a specific time. To be able to understand and appreciate why fast faultdetection is necessary, power system faults and theirconsequences are briefly discussed. The consequences of a faultare dependent of a number of different factors, one of thefactors being the duration of the fault. The importance of the speed of the fault detection dependson the type of equipment used to clear the fault. A circuitbreaker which interrupt currents only when they pass through anatural zero crossing might be less dependent on the speed ofthe fault detection than a fault current limiter which limitsthe fault current before it has reached its first prospectivecurrent peak. In order to be able to detect a fault in a power system, thepower system must be observed, i.e., measurements of relevantquantities must be performed so that the fault detectionequipment can obtain information of the state of the system.The fault detection equipment and some general methods of faultdetection are briefly described. Some algorithms and their possible adaptation to fast faultdetection are described. A common principle of many algorithmsare that they assume that either a signal or the power systemobject can be described by a model. Sampled data values arethen fitted to the model so that an estimate of relevantparameters needed for fault detection is obtained. An algorithmwhich do not fit samples to a model but use instantaneouscurrent values for fault detection is also described andevaluated. Since the exact state of a power system never is known dueto variations in power production and load, a model of thepower system or of the signal can never be perfect, i.e., theestimated parameter can never be truly correct. Furthermore,errors from the data acquisition system contribute to the totalerror of the estimated parameter. Two case studies are used to study the performance of the(modified) algorithms. For those studies it has been shown thatthe algorithms can detect a fault within approximately 1msafter fault inception and that one of the algorithms candiscriminate between a fault and two types of common powersystem transients (capacitor and transformer energization). The second case study introduced a system with two sourceswhich required a directional algorithm to discriminate betweenfaults inside or outside the protection zone. It is concluded that under certain assumptions it ispossible to detect power system faults within approximately 1msand that it is possible to discriminate a power system faultfrom power system transient that regularly occurs within powersystems but which not are faults. / NR 20140805
117

The load flow problem without slack bus /

Low, Sek Luen, 1953- January 1979 (has links)
No description available.
118

Economic dispatch with transmission limits using second derivative information

Bottéro, Marie-Hélène Eliane. January 1980 (has links)
No description available.
119

Analytic approach to economic dispatch

Fahmideh-Vojdani, A. (Alireza) January 1979 (has links)
No description available.
120

The minimum cost optimal power flow problem solved via the restart homotopy continuation method /

Ponrajah, Ranendra Anthony January 1987 (has links)
No description available.

Page generated in 0.1038 seconds