Spectrofluorometric Probe Methods for Examining Preferential Solvation in Binary Mixtures

Wilkins, Denise C. 08 1900 (has links)
Spectrofluorometric probe methods are developed and examined regarding their ability to model preferential solvation around probe molecules in binary solvents. The first method assumes that each fluorophore is solvated by only one type of solvent molecule and that each fluorophore contributes to the emission intensity. Expressions for this model are illustrated using fluorescence behavior of pyrene, benzo[e]pyrene, benzo[ghi]perylene, and coronene dissolved in binary n-heptane + 1,4-dioxane and n-heptane + tetrahydrofuran mixtures. The second method treats the solvational sphere as a binary solvent microsphere, with the fluorophore's energy in both the ground and the excited states mathematically expressed using the "nearly ideal binary solvent" (NIBS) model. Expressions derived from this model are illustrated using fluorescence behavior of 9,9'-bianthracene and 9,9*-bianthracene-10-carboxaldehyde in binary toluene + acetonitrile and dibutyl ether + acetonitrile.
2

Avaliação clínica e microbiológica de diferentes modalidades de terapia periodontal não-cirúrgica em pacientes com periodontite crônica

Silva, Emílio Barbosa e [UNESP] 05 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-05Bitstream added on 2014-06-13T20:45:01Z : No. of bitstreams: 1 silva_eb_dr_arafo.pdf: 2283935 bytes, checksum: a7ddd656bfe4bd69726cb26dbb45597f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar em pacientes portadores de periodontite crônica avançada, os efeitos de diferentes modalidades de tratamento periodontal não-cirúrgico na composição microbiana subgengival e nos parâmetros clínicos de avaliação da doença periodontal em diferentes tempos de análise. Foram avaliados 30 pacientes com idade entre 25 e 68 anos com profundidade à sondagem inicial d 6mm e = 8 mm nos sítios selecionados. Estes pacientes foram divididos em três grupos, cada um contendo 10 pessoas de acordo com o tratamento realizado: Grupo 1 - realização de raspagem e alisamento radiculares supra e subgengivais concomitantemente no mesmo dia; Grupo 2 - realização de raspagem alisamento e polimento supragengival e 7 dias após realização de raspagem e alisamento radiculares subgengival; Grupo 3 - realização de raspagem alisamento e polimento somente supragengival por 30 dias e complementação da raspagem subgengival após este período. Os pacientes foram avaliados antes e após 7, 15, 30 e 60 dias de realizado o procedimento inicial pelos seguintes parâmetros clínicos: profundidade de sondagem, nível de inserção, sangramento à sondagem, presença de placa, inflamação gengival e supuração. Também foram realizadas coletas de amostras de placa subgengival nos mesmos sítios e períodos e analisadas a prevalência e os níveis de 36 espécies bacterianas pela técnica do checkerboard DNA-DNA hybridization. Como resultados deste estudo verificamos que a profundidade de sondagem foi significativamente reduzida pelos tratamentos de raspagem supra e subgengival concomitante e raspagem supra 7 dias prévios a subgengival. O grupo que recebeu somente raspagem supragengival até o 30º dia não apresentou melhora até este período, com uma redução significativa após a complementação da raspagem... . / The purpose of the present investigation was to evaluate the effects of different modalities of non-surgical periodontal treatment in 30 patients with advanced chronic periodontitis. Subjects were monitored clinically and microbiologically prior and 7, 15, 30 and 60 days after this three periodontal treatments: Group 1 - concomitant supra and subgingival scaling and root planning; Group 2 - supragingival scaling 7 days prior to subgingival scaling and root planning; Group 3 - supragingival scaling 30 days prior to subgingival scaling and root planning. Clinical assessment of plaque, redness, suppuration, bleeding on probing, pocket depth and clinical attachment level were made in two anterior teeth per patient. Subgingival plaque samples were taken at the same sites and the presence and levels of 36 subgingival bacteria species were determined using checkerboard DNA-DNA hybridization. The mean levels and % colonized by each species (prevalence) was computed for each subject at each visit. As results of this study was verified that pocket depth was significantly reduced for group 1 and 2. The group that received only supragengival scaling until the 30th day didn't improve until this period, with a significant reduction after the complementation of subgengival scaling and root planning. The clinical attachment level parameter didn't demonstrate significant alteration in none of the three groups along the time. However all the groups showed improvement or stability in this parameter, tends the group 1 presented the best results, followed for the group 2 and 3, respectively. All the groups didn't present differences between the initial period and the times of 30 and 60 days in relation to the other parameters of clinical evaluation, except for the gingival redness that had group 2 with better results, followed for the group 1 and 3... (Complete abstract, click electronic address below).
3

Avaliação clínica e microbiológica de diferentes modalidades de terapia periodontal não-cirúrgica em pacientes com periodontite crônica /

Silva, Emílio Barbosa e. January 2004 (has links)
Orientador: Benedicto Egbert Corrêa de Toledo / Banca: Enilson Antônio Sallum / Banca: Márcio Fernando de Moraes Grisi / Banca: Silvana Regina Perez Orrico / Banca: Valdir Gouvêia Garcia / Resumo: O objetivo deste estudo foi avaliar em pacientes portadores de periodontite crônica avançada, os efeitos de diferentes modalidades de tratamento periodontal não-cirúrgico na composição microbiana subgengival e nos parâmetros clínicos de avaliação da doença periodontal em diferentes tempos de análise. Foram avaliados 30 pacientes com idade entre 25 e 68 anos com profundidade à sondagem inicial d 6mm e = 8 mm nos sítios selecionados. Estes pacientes foram divididos em três grupos, cada um contendo 10 pessoas de acordo com o tratamento realizado: Grupo 1 - realização de raspagem e alisamento radiculares supra e subgengivais concomitantemente no mesmo dia; Grupo 2 - realização de raspagem alisamento e polimento supragengival e 7 dias após realização de raspagem e alisamento radiculares subgengival; Grupo 3 - realização de raspagem alisamento e polimento somente supragengival por 30 dias e complementação da raspagem subgengival após este período. Os pacientes foram avaliados antes e após 7, 15, 30 e 60 dias de realizado o procedimento inicial pelos seguintes parâmetros clínicos: profundidade de sondagem, nível de inserção, sangramento à sondagem, presença de placa, inflamação gengival e supuração. Também foram realizadas coletas de amostras de placa subgengival nos mesmos sítios e períodos e analisadas a prevalência e os níveis de 36 espécies bacterianas pela técnica do "checkerboard DNA-DNA hybridization". Como resultados deste estudo verificamos que a profundidade de sondagem foi significativamente reduzida pelos tratamentos de raspagem supra e subgengival concomitante e raspagem supra 7 dias prévios a subgengival. O grupo que recebeu somente raspagem supragengival até o 30º dia não apresentou melhora até este período, com uma redução significativa após a complementação da raspagem... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of the present investigation was to evaluate the effects of different modalities of non-surgical periodontal treatment in 30 patients with advanced chronic periodontitis. Subjects were monitored clinically and microbiologically prior and 7, 15, 30 and 60 days after this three periodontal treatments: Group 1 - concomitant supra and subgingival scaling and root planning; Group 2 - supragingival scaling 7 days prior to subgingival scaling and root planning; Group 3 - supragingival scaling 30 days prior to subgingival scaling and root planning. Clinical assessment of plaque, redness, suppuration, bleeding on probing, pocket depth and clinical attachment level were made in two anterior teeth per patient. Subgingival plaque samples were taken at the same sites and the presence and levels of 36 subgingival bacteria species were determined using checkerboard DNA-DNA hybridization. The mean levels and % colonized by each species (prevalence) was computed for each subject at each visit. As results of this study was verified that pocket depth was significantly reduced for group 1 and 2. The group that received only supragengival scaling until the 30th day didn't improve until this period, with a significant reduction after the complementation of subgengival scaling and root planning. The clinical attachment level parameter didn't demonstrate significant alteration in none of the three groups along the time. However all the groups showed improvement or stability in this parameter, tends the group 1 presented the best results, followed for the group 2 and 3, respectively. All the groups didn't present differences between the initial period and the times of 30 and 60 days in relation to the other parameters of clinical evaluation, except for the gingival redness that had group 2 with better results, followed for the group 1 and 3... (Complete abstract, click electronic address below). / Doutor
4

Sistema automatizado para a medição de desvios de forma e orientação / Automated system for measuring form and orientation deviations

Sagawa, Juliana Keiko 12 September 2008 (has links)
O modo de produção vigente exige cada vez mais rapidez, precisão e eficiência nos processos. Em resposta a essas tendências, constituem-se desafios à área de Metrologia a obtenção de sistemas de medição e algoritmos de avaliação de erros mais precisos; a avaliação de incertezas com precisão; e a execução de medições com rapidez. Neste trabalho apresenta-se um Sistema Automatizado de medição para avaliação dos desvios de forma e orientação de componentes. O sistema é baseado na utilização de um robô industrial com seis graus de liberdade e sensores de deslocamento do tipo LVDT. O emprego de sistemas como o proposto para a avaliação de desvios geométricos está condicionado à utilização de um modelo matemático de separação de erros, uma vez que a acurácia de posicionamento e a repetibilidade dos robôs disponíveis atualmente não são adequadas à medição de grandezas micrométricas. Além da aplicação do modelo de separação de erros, este trabalho inclui a elaboração modelos e rotinas de processamento de dados para a avaliação de desvios geométricos. Sistemas similares desenvolvidos foram aplicados principalmente à medição de desvios de retilineidade, e em alguns casos, circularidade. Neste trabalho, buscou-se ampliar o escopo de aplicações deste tipo de sistema, de forma a abranger não só a avaliação dos desvios de retilineidade, mas também a avaliação dos desvios de planicidade e perpendicularismo. Além disso, o enfoque da pesquisa foi dirigido à avaliação do desempenho do sistema e do modelo de separação de erros, por meio da realização de testes experimentais com três peças distintas e por meio de análise comparativa com sistemas convencionais de medição. Os resultados obtidos comprovaram a eficiência do sistema proposto, que destacou-se também por apresentar boa repetibilidade. / The current production system demands fast, efficient and precise processes. In order to address these issues, most of the research efforts in the Metrology area have been focused into the development of faster and more accurate measuring systems as well as into the definition of methods to better evaluate uncertainties in measurement. This work presents an automated system for the evaluation of form and orientation deviations of mechanical components. A six-degree-of-freedom industrial robot and LVDT sensors are used to take the measurements. The implementation of the proposed system depends on the application of a mathematical model for error separation since the accuracy of positioning and repeatability presented by the currently available industrial robots are not suitable for measuring micrometric deviations. Besides the application of the error separation model, this work also includes the development of data processing algorithms for the evaluation of geometrical deviations. Few similar systems to the proposed one were developed and applied mainly for straightness and, in some cases, roundness measurements. This work aimed at broadening the range of applications of this kind of measuring systems, making them suitable for the evaluation of flatness and orthogonality deviations. Additionally, the focus of the research was set to the performance evaluation of the system and the error separation model. In order to do that, experimental tests with three different parts were carried out. The values found were compared to the values of the deviations measured with conventional GD&T practice. The obtained results showed the efficiency of the proposed system, which also presented good repeatability.
5

Desenvolvimento de um sistema automatizado e dedicado de medição / Development of an automated and dedicated measuring system

Fabricio Tadeu Paziani 28 September 2005 (has links)
Sistemas dedicados de medição são especialmente recomendados para a inspeção repetida de uma característica mecânica. Entretanto, instrumentos e sistemas de medição apresentam erros que deterioram o resultado da inspeção. Tal circunstância demanda a aplicação de técnicas de separação de erros que viabilizem o desacoplamento dos erros induzidos pelo sistema de medição daqueles apresentados pelas peças medidas. Este trabalho tem por objetivo apresentar um sistema automatizado e dedicado à medição de erros de retilineidade e circularidade em componentes mecânicos. Um robô industrial foi empregado para operar dispositivos de medição específicos para cada tipo de medida. Entretanto, robôs industriais apresentam erros de posicionamento relativamente grandes que impedem a utilização do sistema de coordenadas do equipamento como referência para medições precisas. Para minimizar o efeito dos erros do sistema de medição sobre o valor medido, foram aplicadas técnicas multi-sensoriais de separação de erros. Na medição do erro de retilineidade, uma nova abordagem foi desenvolvida para minimizar a influência do erro de posicionamento axial dos sensores, que constitui a maior fonte de erros no processo de desacoplamento. Foram realizadas simulações computacionais e testes experimentais aplicados à medição do erro de retilineidade e de circularidade de vários artefatos que comprovaram a efetividade da metodologia utilizada. / Dedicated measuring systems are particularly recommended for the repetitive inspection of a mechanical feature. However, measuring instruments and systems present errors that deteriorate the result of the inspection. Such a circumstance demands the application of error separation techniques that perform decoupling of errors induced by the measuring system from part errors. This work aims to present an automated measuring system that is dedicated to the task of inspecting straightness and roundness errors in mechanical components. An industrial robot was employed to operate specific measuring devices for each measurement. However, industrial robots present relatively large positioning errors that prevent the use of their coordinate system as a reference to accurate measurements. In order to minimize the effect of the measuring system on the measured value, multi-probe error separation techniques were employed. On the straightness measurement, a new approach was developed to minimize the influence of the axial positioning error of the sensors, which consist of the major error source on the decoupling process. Computational simulations and experimental straightness and roundness tests were accomplished for various artefacts, which confirmed the effectiveness of the employed methodology.
6

Desenvolvimento de um sistema automatizado e dedicado de medição / Development of an automated and dedicated measuring system

Paziani, Fabricio Tadeu 28 September 2005 (has links)
Sistemas dedicados de medição são especialmente recomendados para a inspeção repetida de uma característica mecânica. Entretanto, instrumentos e sistemas de medição apresentam erros que deterioram o resultado da inspeção. Tal circunstância demanda a aplicação de técnicas de separação de erros que viabilizem o desacoplamento dos erros induzidos pelo sistema de medição daqueles apresentados pelas peças medidas. Este trabalho tem por objetivo apresentar um sistema automatizado e dedicado à medição de erros de retilineidade e circularidade em componentes mecânicos. Um robô industrial foi empregado para operar dispositivos de medição específicos para cada tipo de medida. Entretanto, robôs industriais apresentam erros de posicionamento relativamente grandes que impedem a utilização do sistema de coordenadas do equipamento como referência para medições precisas. Para minimizar o efeito dos erros do sistema de medição sobre o valor medido, foram aplicadas técnicas multi-sensoriais de separação de erros. Na medição do erro de retilineidade, uma nova abordagem foi desenvolvida para minimizar a influência do erro de posicionamento axial dos sensores, que constitui a maior fonte de erros no processo de desacoplamento. Foram realizadas simulações computacionais e testes experimentais aplicados à medição do erro de retilineidade e de circularidade de vários artefatos que comprovaram a efetividade da metodologia utilizada. / Dedicated measuring systems are particularly recommended for the repetitive inspection of a mechanical feature. However, measuring instruments and systems present errors that deteriorate the result of the inspection. Such a circumstance demands the application of error separation techniques that perform decoupling of errors induced by the measuring system from part errors. This work aims to present an automated measuring system that is dedicated to the task of inspecting straightness and roundness errors in mechanical components. An industrial robot was employed to operate specific measuring devices for each measurement. However, industrial robots present relatively large positioning errors that prevent the use of their coordinate system as a reference to accurate measurements. In order to minimize the effect of the measuring system on the measured value, multi-probe error separation techniques were employed. On the straightness measurement, a new approach was developed to minimize the influence of the axial positioning error of the sensors, which consist of the major error source on the decoupling process. Computational simulations and experimental straightness and roundness tests were accomplished for various artefacts, which confirmed the effectiveness of the employed methodology.
7

Sistema automatizado para a medição de desvios de forma e orientação / Automated system for measuring form and orientation deviations

Juliana Keiko Sagawa 12 September 2008 (has links)
O modo de produção vigente exige cada vez mais rapidez, precisão e eficiência nos processos. Em resposta a essas tendências, constituem-se desafios à área de Metrologia a obtenção de sistemas de medição e algoritmos de avaliação de erros mais precisos; a avaliação de incertezas com precisão; e a execução de medições com rapidez. Neste trabalho apresenta-se um Sistema Automatizado de medição para avaliação dos desvios de forma e orientação de componentes. O sistema é baseado na utilização de um robô industrial com seis graus de liberdade e sensores de deslocamento do tipo LVDT. O emprego de sistemas como o proposto para a avaliação de desvios geométricos está condicionado à utilização de um modelo matemático de separação de erros, uma vez que a acurácia de posicionamento e a repetibilidade dos robôs disponíveis atualmente não são adequadas à medição de grandezas micrométricas. Além da aplicação do modelo de separação de erros, este trabalho inclui a elaboração modelos e rotinas de processamento de dados para a avaliação de desvios geométricos. Sistemas similares desenvolvidos foram aplicados principalmente à medição de desvios de retilineidade, e em alguns casos, circularidade. Neste trabalho, buscou-se ampliar o escopo de aplicações deste tipo de sistema, de forma a abranger não só a avaliação dos desvios de retilineidade, mas também a avaliação dos desvios de planicidade e perpendicularismo. Além disso, o enfoque da pesquisa foi dirigido à avaliação do desempenho do sistema e do modelo de separação de erros, por meio da realização de testes experimentais com três peças distintas e por meio de análise comparativa com sistemas convencionais de medição. Os resultados obtidos comprovaram a eficiência do sistema proposto, que destacou-se também por apresentar boa repetibilidade. / The current production system demands fast, efficient and precise processes. In order to address these issues, most of the research efforts in the Metrology area have been focused into the development of faster and more accurate measuring systems as well as into the definition of methods to better evaluate uncertainties in measurement. This work presents an automated system for the evaluation of form and orientation deviations of mechanical components. A six-degree-of-freedom industrial robot and LVDT sensors are used to take the measurements. The implementation of the proposed system depends on the application of a mathematical model for error separation since the accuracy of positioning and repeatability presented by the currently available industrial robots are not suitable for measuring micrometric deviations. Besides the application of the error separation model, this work also includes the development of data processing algorithms for the evaluation of geometrical deviations. Few similar systems to the proposed one were developed and applied mainly for straightness and, in some cases, roundness measurements. This work aimed at broadening the range of applications of this kind of measuring systems, making them suitable for the evaluation of flatness and orthogonality deviations. Additionally, the focus of the research was set to the performance evaluation of the system and the error separation model. In order to do that, experimental tests with three different parts were carried out. The values found were compared to the values of the deviations measured with conventional GD&T practice. The obtained results showed the efficiency of the proposed system, which also presented good repeatability.