11 |
Metodo de coincidencia generalizado para a medida absoluta da atividade de radionuclideos .Aplicacao na determinacao do coeficiente de conversao da transicao de 279KeV do T1 203MOURA, LAIS P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:36Z (GMT). No. of bitstreams: 1
01292.pdf: 4197340 bytes, checksum: e065f97f212a4098373c6cd14232d7c2 (MD5) / Tese (Doutoramento) / IPEN/T / Universidade Estadual de Campinas - UNICAMP/SP
|
12 |
Determinacao de sup210Pb e sup210Po em tabaco de cigarros nacionaisPERES, ANA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:49Z (GMT). No. of bitstreams: 1
06653.pdf: 2692311 bytes, checksum: 9cf9c14400638383aed081e15b1227b7 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
13 |
Quantitative basis for component factors of gas flow proportional counting efficienciesNichols, Michael 21 August 2009 (has links)
Counting efficiencies were determined by empirical measurement and Monte Carlo simulation for carbon-14, strontium-89, strontium-90, and yttrium-90 standards counted by low-background gas flow proportional counter for strontium carbonate precipitates in the range from 3 to 33 mg cm⁻². The maximum beta particle energies range from 0.156 MeV for carbon-14 to 2.28 MeV for yttrium-90. The parameters for estimating the counting efficiency are summarized for sources with areal thickness of 14 mg cm⁻² and over the range in strontium carbonate areal thickness from 0.1 mg cm⁻² to 33 mg
cm⁻². Uncertainty budgets providing estimates of the uncertainty, sources of variability in the calibration process, and the total expanded uncertainty are presented. Information is presented for the Monte Carlo simulation regarding the composition of the detector window, the energy excluded by the amplifier discriminator of the counting system, and the physical density of materials for this analytical process. The histogram normalization routine implemented within MCNP is described and found to bias the probability distribution for beta-particle energy spectra. The difference in the specification of the probability distribution for beta-particle energy spectra in ICRU 56 Appendix D and MCNP requirements are described and a correction for the bias introduced during the normalization process for beta spectra is provided. Counting efficiencies determined by empirical measurement and Monte Carlo simulations agree within the total expanded uncertainties of the measurements and the uncertainties of the Monte Carlo simulations.
|
14 |
Monte Carlo simulation of gas-filled radiation detectorsKundu, Ashoke January 2000 (has links)
No description available.
|
15 |
Desenvolvimento de um sistema de emissao exoeletronica termicamente estimulada para a aplicacao em dosimetriaROCHA, FELICIA DEL G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:30Z (GMT). No. of bitstreams: 1
05225.pdf: 5071584 bytes, checksum: 1e93e518cbd529a7903fc24403a4234d (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
16 |
Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências / Desintegration rate of Tc-99m and In-111 radioactive solutions in coincidence systemsBRITO, ANDREIA B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
17 |
A Influencia do padrao de calibracao e da composicao do residuo de amostras de agua na eficiencia de um contador proporcional para contagem alfa e beta total. Aplicacao no controle radiologico do IPEN-CNEN/SPSANTOS, CECILIA M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:57Z (GMT). No. of bitstreams: 1
08716.pdf: 7231985 bytes, checksum: 03e0ae1f8cfad93fe1403076edaf1b9b (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
18 |
Desenvolvimento de um sistema de emissao exoeletronica termicamente estimulada para a aplicacao em dosimetriaROCHA, FELICIA DEL G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:30Z (GMT). No. of bitstreams: 1
05225.pdf: 5071584 bytes, checksum: 1e93e518cbd529a7903fc24403a4234d (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
19 |
Determinação da taxa de desintegração de Tc-99m e In-111 em sistemas de coincidências / Desintegration rate of Tc-99m and In-111 radioactive solutions in coincidence systemsBRITO, ANDREIA B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:46Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta os métodos de padronização de 111In e 99mTc, em sistemas de coincidências 4πβ-γ. O 111In foi produzido em cíclotron pela reação 111Cd(p, n)111In; decai com uma meia vida de 2,8 dias pelo processo de captura eletrônica populando os níveis excitados do 111Cd, emitindo raios gama de 171 keV e 245 keV. O 99mTc decai com uma meia vida de 6,007 h por transição isomérica do decaimento radioativo do 99Mo . A padronização do 111In foi feita no sistema 4πβ-γ constituído de um detector proporcional em geometria 4π acoplado a dois cristais cintiladores de NaI(Tl) com eletrônica convencional. A radiação gama selecionada para medida em coincidência foi de (171 + 245) keV. A escolha da janela gama foi baseada na análise da previsão da curva de extrapolação obtida na simulação de Monte Carlo. A padronização do 99mTc foi feita num sistema 4πβ-γ usando um contador proporcional de janela fina acoplado a um cristal de cintilação NaI (Tl). A eficiência beta foi variada por discriminação eletrônica, usando sistema de coincidências por software (SCS). A padronização do 99mTc foi feita pela seleção de dois intervalos gama, um no pico de absorção total de 140 keV e outro no pico de absorção total dos raios X de 20 keV. O resultado da atividade experimental de duas soluções de 111In concorda com o resultado obtido pela simulação de Monte Carlo. As atividades experimentais do 99mTc para os dois intervalos gama selecionados estão de acordo dentro da incerteza experimental, indicando que a metodologia adotada é adequada. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
20 |
A Influencia do padrao de calibracao e da composicao do residuo de amostras de agua na eficiencia de um contador proporcional para contagem alfa e beta total. Aplicacao no controle radiologico do IPEN-CNEN/SPSANTOS, CECILIA M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:57Z (GMT). No. of bitstreams: 1
08716.pdf: 7231985 bytes, checksum: 03e0ae1f8cfad93fe1403076edaf1b9b (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
Page generated in 0.1154 seconds