• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 76
  • 6
  • 4
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 287
  • 128
  • 86
  • 85
  • 70
  • 51
  • 37
  • 29
  • 28
  • 28
  • 27
  • 26
  • 23
  • 22
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Collagen and fibrin biopolymer microthreads For bioengineered ligament regeneration

Cornwell, Kevin G. January 2007 (has links)
Dissertation (Ph.D.) -- Worcester Polytechnic Institute. / Keywords: Ligament; ACL; Collagen; Fibrin; Microthread; Fiber; Thread; FGF-2; Fibroblast; Tissue regeneration; Tissue engineering. Includes bibliographical references.
72

Design of a noninvasive system for the evaluation of collagen scaffolds using MRI

Howes, Stuart C. January 2007 (has links)
Thesis (M.S.) -- Worcester Polytechnic Institute. / Keywords: histology; implant; biomaterials; MRI. Includes bibliographical references (p.80-86).
73

Artroplastia total modular híbrida da articulação coxofemoral: estudo experimental em cães

Minto, Bruno Watanabe [UNESP] 29 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-29Bitstream added on 2014-06-13T19:01:31Z : No. of bitstreams: 1 minto_bw_dr_botfmvz.pdf: 1369635 bytes, checksum: 072ba26b6934c744d4aadd30423153ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A artroplastia total da articulação coxofemoral é a técnica cirúrgica mais comumente realizada para o tratamento da displasia coxofemoral canina grave. Diversos modelos e sistemas protéticos são descritos; desde os sistemas cimentados de cabeça femoral fixa que foram amplamente utilizados no passado, até os mais recentes, munidos de sistema osteointegravel e cabeça femoral intercambiável. A presente pesquisa teve como objetivo avaliar a aplicação de uma prótese total modular híbrida da articulação coxofemoral confeccionada no Brasil, em cães sadios, até 360 dias de pós-operatório. Foram utilizados 10 animais da espécie canina esqueleticamente maduros, sem raça definida, machos e fêmeas, com peso variando entre 19 e 27 kg, sem alterações no aparelho locomotor. Constituiu-se um único grupo experimental de animais submetidos ao procedimento de artroplastia total, utilizando-se componente femoral cimentado de cabeça intercambiável e componente acetabular não cimentado. Os cães foram submetidos ao exame clínico e radiográfico às 24 horas, e aos 30, 60, 90, 120, 180 e 360 dias após a cirurgia. A artroplastia total coxofemoral foi exequível. Sete dos 10 animais apresentaram escore excelente na locomoção, no período de avaliação final; dois apresentaram luxação protética com subsequente afrouxamento do componente femoral, sendo tratados por excisão artroplástica; um cão apresentou fratura completa do fêmur no pós-operatório imediato, e foi submetido à remoção dos componentes protéticos e osteossíntese. A artroplastia total modular híbrida da articulação coxofemoral canina proporcionou excelente resultado funcional do membro operado. / Total hip arthroplasty is the most accepted treatment for severe canine hip dysplasia. Several prosthetic devices and systems are available, from the old fixed head cemented prostheses to the modern uncemented modular ones. The aim of this study is to evaluate the surgical procedure and results of hybrid modular total hip prosthesis, developed in Brazil. Ten mature healthy mongrel dogs were used, their weight varied between 19 and 27kg. They did not have any orthopaedic problems. Hybrid modular total hip arthroplasty was performed in all 10 dogs. Cemented modular femoral stems and uncemented porous coated acetabular cups were used. Clinical and radiographic evaluations were performed before surgery and again at 30, 60, 90, 120, 180 and 360 days postoperatively. The technique of total hip arthroplasty was performed without complications or difficulties. Excellent weight bearing was noticed on the operated limb in seven dogs. Luxation followed by loosening, was noticed in two dogs and they were properly treated with an femoral head osteotomy. A femoral fracture occured in one dog, which was properly treated with full implant removal and femoral ostheosynthesis. The canine hybrid modular total hip arthroplasty provided excellent function of the operated limb.
74

Proposta de protocolo clínico para utilização do laser de baixa potência em estomatite protética associada a candidose atrópica

MEZZARANE, LILIAN A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:21Z (GMT). No. of bitstreams: 1 12722.pdf: 558008 bytes, checksum: 01284590d84b5a596a55c0b0b7177695 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
75

Estudo de materiais alternativos para aplicacao em sistemas de proteses odontologicas com conexoes magneticas / Alternative materials study for dental magnetics attachments applications

MARQUES, ROGERIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:32Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
76

Artroplastia total modular híbrida da articulação coxofemoral : estudo experimental em cães /

Minto, Bruno Watanabe. January 2009 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Banca: Luiz Carlos Vulcano / Banca: Paulo Iamaguti / Banca: Gilberto José Cação Pereira / Banca: Fernando De Biasi / Resumo: A artroplastia total da articulação coxofemoral é a técnica cirúrgica mais comumente realizada para o tratamento da displasia coxofemoral canina grave. Diversos modelos e sistemas protéticos são descritos; desde os sistemas cimentados de cabeça femoral fixa que foram amplamente utilizados no passado, até os mais recentes, munidos de sistema osteointegravel e cabeça femoral intercambiável. A presente pesquisa teve como objetivo avaliar a aplicação de uma prótese total modular híbrida da articulação coxofemoral confeccionada no Brasil, em cães sadios, até 360 dias de pós-operatório. Foram utilizados 10 animais da espécie canina esqueleticamente maduros, sem raça definida, machos e fêmeas, com peso variando entre 19 e 27 kg, sem alterações no aparelho locomotor. Constituiu-se um único grupo experimental de animais submetidos ao procedimento de artroplastia total, utilizando-se componente femoral cimentado de cabeça intercambiável e componente acetabular não cimentado. Os cães foram submetidos ao exame clínico e radiográfico às 24 horas, e aos 30, 60, 90, 120, 180 e 360 dias após a cirurgia. A artroplastia total coxofemoral foi exequível. Sete dos 10 animais apresentaram escore excelente na locomoção, no período de avaliação final; dois apresentaram luxação protética com subsequente afrouxamento do componente femoral, sendo tratados por excisão artroplástica; um cão apresentou fratura completa do fêmur no pós-operatório imediato, e foi submetido à remoção dos componentes protéticos e osteossíntese. A artroplastia total modular híbrida da articulação coxofemoral canina proporcionou excelente resultado funcional do membro operado. / Abstract: Total hip arthroplasty is the most accepted treatment for severe canine hip dysplasia. Several prosthetic devices and systems are available, from the old fixed head cemented prostheses to the modern uncemented modular ones. The aim of this study is to evaluate the surgical procedure and results of hybrid modular total hip prosthesis, developed in Brazil. Ten mature healthy mongrel dogs were used, their weight varied between 19 and 27kg. They did not have any orthopaedic problems. Hybrid modular total hip arthroplasty was performed in all 10 dogs. Cemented modular femoral stems and uncemented porous coated acetabular cups were used. Clinical and radiographic evaluations were performed before surgery and again at 30, 60, 90, 120, 180 and 360 days postoperatively. The technique of total hip arthroplasty was performed without complications or difficulties. Excellent weight bearing was noticed on the operated limb in seven dogs. Luxation followed by loosening, was noticed in two dogs and they were properly treated with an femoral head osteotomy. A femoral fracture occured in one dog, which was properly treated with full implant removal and femoral ostheosynthesis. The canine hybrid modular total hip arthroplasty provided excellent function of the operated limb. / Doutor
77

Avaliação "in vitro " da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivos /

Bottino, Marco Antonio. January 1998 (has links)
Resumo: Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study assessed the quality of cervical adaptation in full metal crowns, with a variation in: a) the type of cervical preparation- beveled shoulder, 135-degree preparation, 90-degree shoulder, chamfer and knife edge; b) internal surfaces of the crowns with or without relief; c) the types of luting agents and their commercial brands- Harvard zinc phosphate, Ketac-Cem glass ionomer, Durelon zinc polycarboxylate and Panavia Ex resinous. Initially, machined stainless steel models were made according to each experimental margin design. Stainless steel metal caps were prepared with or without a 30-micrometer spacing of their internal surfaces, kept away 0.5 mm of the cervical end limit; they were precisely fitted, making a set with exact adaptation and seating. The caps were cemented on the specimens by means of different luting agents , handled according to the manufacturer's instructions. Methods were developed to reuse the specimens. Precise measures were obtained by preventing caps from moving during measurements. The conclusions were: a) the best mean of cervical adaptation, similar to each other , was obtained in standard models with preparations : knife edge, 1350 shoulder and chamfer; b) the worst mean of cervical adaptation, similar between them , was obtained in standard models with: straight shoulder and beveled shoulder; c) there was a significant improvement in adaptation when the metal caps were cemented with relief in their internal surface; d) cements presented decreasing cervical adaption, in the following order: Ketac-Cem, Harvard, Durelon and Panavia Ex; and, e) the methodology used allowed work with positive values of cervical adaptation.
78

Efetividade de parafusos com tratamento de superfície na estabilidade de pilares em zircônia após carga cíclica /

Basílio, Mariana de Almeida. January 2011 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Marcelo Mesquita Ferraz / Banca: José Maurício dos Santos Nunes Reis / Resumo: Com o objetivo de prevenir o afrouxamento, parafusos do pilar com lubrificantes sólidos de superfície foram desenvolvidos e introduzidos no mercado. Assim, foi proposto avaliar a efetividade de parafusos de liga de titânio com e sem tratamento de superfície sobre a estabilidade de pilares em zircônia (ZrO2) após carga cíclica, bem como observar alterações estruturais por meio de microscopia eletrônica de varredura (MEV). Para isso, 20 pilares UCLA em ZrO2 foram fixados sobre implantes do tipo hexágono externo com torque de 20 Ncm e divididos em 2 grupos (n=10), conforme o parafuso do pilar: (A) pilar-implante e parafuso de liga de titânio (Ti); (B) pilar-implante e parafuso de liga de titânio com cobertura Diamond Like Carbon (DLC/Ti). O valor do torque reverso (pré-carga) foi mensurado antes e após o carregamento. O teste foi realizado de acordo com a norma ISO 14801. Cargas cíclicas (0,5 x 106; 15 Hz) entre 11 - 211 N foram aplicadas com 30º de inclinação em relação ao longo eixo dos implantes. As médias dos grupos foram calculadas e comparadas utilizando análise de variância de dois fatores e testes F (α=0,05). Os resultados mostraram que antes do carregamento a média do grupo Ti foi significativamente maior que a do grupo DLC/Ti (p=0,021). Após o carregamento ambas as médias 14 diminuíram significativamente, sem diferença significante entre elas (p=0,499). As imagens obtidas na MEV revelaram micro-fraturas na base de assentamento do pilar. Nas condições estudadas, concluiu-se que: (1) os parafusos estudados apresentaram efetividade similar com relação à manutenção da pré-carga; (2) a redução significativa no torque reverso e os danos observados na MEV indicam que o acompanhamento dos pacientes é necessário para assegurar a longevidade das restaurações de ZrO2 implanto-suportadas. / Abstract: In an attempt to prevent screw-loosening problem, abutment screws with surface treatment were developed. Thus, the aim of the current study was to evaluate comparatively the effectiveness of titanium alloy coated screws and noncoated screws on the stability of ZrO2-ceramic abutments after cyclic loading, as soon as observe possible microdamaging in the structure of the components using a scanning electron microscope (SEM). For this, 20 prefabricated ZrO2-ceramic UCLA abutments were tightened to 20 Ncm on their respective external hex implants and divided equally into 2 groups (n=10), according to the type of screws used: (A) implant-abutment and noncoated titanium alloy screw (Ti); (B) implant-abutment and titanium alloy screw with Diamond Like Carbon surface coating (DLC/Ti). The reverse torque value (preload) of the abutment screw was measured before and after loading. The tests were performed according to ISO norm 14801. A cyclic loading (0,5 x 106; 15 Hz) between 11 - 211 N was applied at an angle of 30 degrees to the long axis of the implants. Group means were calculated and compared using ANOVA and F tests (α=0,05). The results showed that before cyclic loading, the mean of Ti group was significantly higher than the DLC/Ti group (p=0,021). After cyclic loading, both means decreased significantly, with no significant differences 16 between them (p=0,499). Under the studied conditions, it can be concluded that: (1) the two abutment screw types presented similar effectiveness in maintaining preload; (2) the significant decrease in reverse torque values and the microdamaging detected at SEM analysis indicate that patient follow-up is needed to ensure the integrity of the ZrO2-ceramic single-implant restorations. / Mestre
79

Efeito de cargas compressivas oblíquas e da simulação de ciclos mastigatório sobre pilares para implantes cone morse / Effects of oblique compressive load and simulated chewing cycles on internal tapered implant-abutment connections

Izabela Cristina Mauricio Moris 15 December 2011 (has links)
A literatura relata que a união osso/implante é extremamente confiável, porém limitações clínicas em relação à prótese ainda ocorrem. Recentemente foi proposto um pilar para implantes cone morse cujo desenho permite a escolha entre coroas cimentadas ou parafusadas, adicionalmente, este pilar também é apresentado em dois tamanhos, o convencional (ø 4,8 mm) e reduzido (ø 3,8 mm). O objetivo deste estudo foi avaliar a resistência à deformação dos pilares protéticos, a resistência de cimentação das coroas e os efeitos da simulação de ciclos mastigatórios sobre: adaptação marginal, perda de torque nos parafusos das coroas e perda de torque dos dois diferentes pilares. Para avaliar a resistência à deformação, 20 implantes/pilares com diâmetro de 4.8 e 3.8 foram submetidos à carga compressiva oblíqua. Para avaliar as outras situações, 40 implantes/pilares foram divididos nos seguintes grupos (N=10): G4.8P- pilar de 4.8 e coroas parafusadas; G4.8C-pilar de 4.8 e coroas cimentadas; G3.8P- pilar de 3.8 e coroas parafusadas; G3.8C- pilar de 3.8 e coroas cimentadas. Todas as coroas foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios e as coroas cimentadas foram submetidas ao teste de resistência à tração previamente ao ensaio. Os conjuntos foram submetidos a 300.000 ciclos de simulação de movimentos mastigatórios. A perda de torque das coroas parafusadas e de todos os pilares foi analisada antes a após o ensaio. Não houve diferenças significantes para a resistência à deformação entre os pilares; para a resistência de cimentação houve diferenças significantes entre os dois pilares (p≤0,05). Para a adaptação marginal houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre os grupos G3.8P (p=0,037) e G3.8C (p≤0,05); para a comparação da adaptação das coroas entre os pilares houve diferenças antes da simulação dos ciclos mastigatórios quando comparado os grupos 3.8C com 3.8P e antes e após da simulação quando comparado os grupos 4.8C com 4.8P, para as demais comparações não houve diferença. Quanto à perda de torque nos parafusos das coroas houve diferenças significantes antes e após a simulação dos ciclos mastigatórios para ambos os pilares, quanto às comparações entre os diferentes grupos antes e após a simulação de ciclos mastigatórios houve diferença apenas após (p=0,008) a simulação. Quanto à perda de torque para os pilares houve diferenças significantes apenas para o grupo 3.8C (p≤0,05) antes e após a simulação dos ciclos mastigatórios. Considerando as limitações deste estudo, conclui-se que em relação à resistência à deformação os pilares apresentaram valores próximos; quanto a retenção das coroas, cimentadas e parafusadas, os pilares de 4.8 foram estatisticamente superiores aos pilares de 3.8; a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das coroas e em relação a perda de torque dos pilares não foram encontradas diferenças estatísticas. / Reports in the literature have stated that the bone/implant interface is extremely reliable. However, clinical limitations in relation to the prosthesis still occur. A Morse taper implant-abutment design that allows choosing between cemented or screwed crowns has been recently proposed. The abutment is presented in two different diameter sizes (conventional (ø 4.8 mm) and narrow (ø 3.8 mm). The aim of this study was to evaluate the resistance to deformation of the implant/abutment interface, the tensile strength of the cemented crowns and the effects of simulated chewing cycles on: marginal fit, crown-screw torque loss and torque loss of the two different abutments. To evaluate the resistance to deformation, 20 abutments with diameter of 4.8 and 3.8 were subjected to compressive oblique load. To evaluate the other situations, 40 implants/abutments were divided into the following groups (N = 10): G4.8P-abutment 4.8 with screwed crowns; G4.8C-abutment 4.8 with cemented crowns; G3.8P abutment 3.8 with screwed crows; G3.8C-abutment 3.8 with cemented crowns. All crowns were evaluated for marginal fit before and after simulation of the chewing cycles. The cemented crowns were subjected to tensile strength test before the simulated chewing cycles. The specimens were subjected to 300,000 cycles that simulated the chewing movements. The torque loss of the screwed crowns and all abutments were analyzed before and after the cycling tests. No significant differences were found for the deformation resistance between the abutments. No significant differences were found in the tensile strength of the cemented crowns between the two abutments (p≤0.05). The marginal fit of the crowns found no significant differences before and after the simulation of the chewing cycles between groups G3.8P (p = 0.037) and G3.8C (p≤0.05). No differences were found in crown misfit between the abutments before simulating the chewing cycles when compared between groups 3.8C 3.8P. No differences were found between groups 4.8C and 4.8P before and after the chewing simulation. Torque loss of the screwed crowns was not significantly different before and after the simulation of the chewing cycles for both abutments. Comparisons between the different groups before and after simulation found significant differences after the simulation of the chewing cycles (p = 0.008). Group 3.8C was the only group that presented significant differences (p≤0.05) before and after the simulation cycles. Within the limitations of this study, it can be concluded that the resistance to deformation between both abutments was similar. Retention of cemented and screwed crowns was statistically higher for the 4.8 abutments when compared to the 3.8 abutments. The simulation of chewing cycles significantly influenced the marginal fit of the crowns. No differences statistically significant in torque loss were found between the two abutments.
80

Efeito da ciclagem mecânica, material e retorque de parafusos, na estabilidade de próteses múltiplas sobre implantes com dois níveis de desajuste / Effect of mechanical cycling, material and retorque screws, in stability of complete implant-suported prosthesis with two fit levels

Farina, Ana Paula 03 January 2011 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T03:20:12Z (GMT). No. of bitstreams: 1 Farina_AnaPaula_D.pdf: 1605705 bytes, checksum: 829e909eecce5995165949e1b708c7d8 (MD5) Previous issue date: 2011 / Resumo: O afrouxamento dos parafusos protéticos é frequentemente encontrado nos exames de rotina e pode causar complicações. Assim, métodos para sua prevenção devem ser desenvolvidos. O objetivo neste estudo foi avaliar a influência do retorque de parafusos protéticos (titânio ou ouro) na estabilidade de próteses totais implantossuportadas com diferentes níveis de adaptação (passiva ou desadaptada), após simulação da função mastigatória por meio de ciclagem mecânica (6 meses, torque de afrouxamento, reaperto dos parafusos + 6 meses de simulação; ou 1 ano de simulação e torque de afrouxamento). No capítulo 1, 10 próteses mandibulares implantossuportadas e 20 modelos foram confeccionados para duas condições de adaptação: passiva (adaptada) e não-passiva (desadaptada). Também foram avaliadas duas técnicas de aperto em função da aplicação de retorque e materiais do parafuso: 1) sem retorque + parafusos de titânio; 2) sem retorque + parafusos de ouro; 3) com retorque + parafusos de titânio; e, 4) com retorque + parafusos de ouro. Para a técnica de aplicação de retorque, os parafusos foram apertados (10 Ncm) e após 10 minutos, reapertados (10 Ncm). O torque de afrouxamento dos parafusos foi mensurado por meio de torquímetro digital de precisão após simulação de 1 ano da função mastigatória. Os dados foram submetidos à análise de variância (ANOVA) em 2 fatores seguido pelo teste complementar de Tukey em (?=0,05). Os fatores adaptação e técnica de aperto (retorque e tipo de parafuso), e a interação entre os fatores foram estatisticamente significantes. O desajuste diminui o torque de afrouxamento. A aplicação do retorque aumentou a estabilidade da conexão dos parafusos, independente da adaptação ou material dos parafusos. No capítulo 2, próteses passivas e não-passivas foram fabricadas de modo semelhante ao capítulo 1. O torque de afrouxamento foi mensurado após 2 condições de simulação de uso clínico: 1) 6 meses / torque de afrouxamento / reaperto / mais 6 meses / torque de afrouxamento; 2) 1 ano de simulação / torque de afrouxamento. Foram utilizados parafusos de titânio e ouro. O teste estatístico foi similar ao capítulo 1. O fator tempo de ciclagem e condição de uso (nível de ajuste e tipo de parafuso), bem como a interação desses fatores influenciaram os valores de torque de afrouxamento (p<0,05). Após 6 meses + 6 meses de simulação de uso clínico, os parafusos de titânio apresentaram maiores valores de torque de afrouxamento quando comparados aos parafusos de ouro, para o mesmo nível de adaptação. Após 1 ano de simulação de uso clínico, ambos materiais dos parafusos em próteses passivas apresentaram valores mais elevados que em próteses não-passivas. Dessa forma podemos concluir que a desadaptação reduz o torque de afrouxamento dos parafusos e que o retorque após 10 minutos consegue estabilizá-los. Parafusos de titânio apresentaram maior estabilidade que parafusos de ouro após 6 meses de simulação devido a sua menor deformação plástica. Quando o tempo de ciclagem foi analisado, parafusos de titânio apresentaram menor estabilidade após 1 ano de simulação devido à perda de torque frente à desadaptação, necessitando acompanhamento mais criterioso para que mantenham sua estabilidade / Abstract: The prosthesis screw loosening is often found at routine examinations and may cause complications. Therefore, methods to prevent them must be developed. The objective of this study was to evaluate the influence of retorque application on joint stability of prosthetic screws (titanium or gold) in implant-supported dentures under different fit levels (passive or misfit), after masticatory function simulated by means of mechanical cycling (6 months, loosening torque, screws retightening and another 6 months of simulation; or 1 year of simulation). In the first chapter, 10 mandibular implant-supported dentures and 20 cast models were fabricated to two fit levels: passive fit and misfit. Two tightening techniques were also evaluated according to the retorque application and screws material: 1) without retorque + titanium screws; 2) without retorque + gold screws; 3) retorque + titanium screws; and 4) retorque + gold screws. The screws were tightened 10 Ncm and retightened to 10 Ncm after 10 min. The screw joint stability was measured after a one-year clinical function simulation using a digital torque meter. Data were analyzed statistically by ANOVA/Tukey's test (?=0.05). The factors of fit level and tightening technique and the interaction between the factors were statistically significant. The misfit decreases the loosening torque. The retorque application increased joint stability independent of fit level or screw material. In the chapter 2, passive and misfit dentures were fabricated as in chapter 1. The loosening torque was measured after two conditions of clinical use simulating: six months / torque loosening / retightening / further six months / loosening torque; and one year of simulation / loosening torque. Titanium and gold screws were used. The statistical analysis was similar to the first chapter. Therefore, the factor cycling time and condition use (fit level and screw type) as well the interaction between the factors influenced the loosening torque values (p<0.05). After six months another six months of masticatory function simulated, the titanium screws showed higher loosening torque than did gold screws for the same fit level. After one year of clinical use simulation, both material screws in passive dentures showed higher loosening torque values than did misfit dentures. Thus we can conclude that the misfit decreases the loosening torque and retorque application increased joint stability. The stability of titanium screws was higher than gold screws after 6 months of simulation, due to its lower plastic deformation. When the cycling time was analyzed, titanium screws were less stable after 1 year of simulation due to loss of torque in misfit presence, requiring more careful monitoring to maintain stability / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.077 seconds